• Title/Summary/Keyword: temperature differential

Search Result 1,546, Processing Time 0.022 seconds

Thermal nonlinear dynamic and stability of carbon nanotube-reinforced composite beams

  • M. Alimoradzadeh;S.D. Akbas
    • Steel and Composite Structures
    • /
    • v.46 no.5
    • /
    • pp.637-647
    • /
    • 2023
  • Nonlinear free vibration and stability responses of a carbon nanotube reinforced composite beam under temperature rising are investigated in this paper. The material of the beam is considered as a polymeric matrix by reinforced the single-walled carbon nanotubes according to different distributions with temperature-dependent physical properties. With using the Hamilton's principle, the governing nonlinear partial differential equation is derived based on the Euler-Bernoulli beam theory. In the nonlinear kinematic assumption, the Von Kármán nonlinearity is used. The Galerkin's decomposition technique is utilized to discretize the governing nonlinear partial differential equation to nonlinear ordinary differential equation and then is solved by using of multiple time scale method. The critical buckling temperatures, the nonlinear natural frequencies and the nonlinear free response of the system is obtained. The effect of different patterns of reinforcement on the critical buckling temperature, nonlinear natural frequency, nonlinear free response and phase plane trajectory of the carbon nanotube reinforced composite beam investigated with temperature-dependent physical property.

Calculation of Outdoor Air Fraction through Economizer Control Types during Intermediate Season

  • Hong, Goopyo;Hong, Jun;Kim, Byungseon Sean
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.13-19
    • /
    • 2016
  • Purpose: In this study, we examined outdoor air fraction using historical data of actual Air Handling Unit (AHU) in the existing building during intermediate season and analyzed optimal outdoor air fraction by control types for economizer. Method: Control types for economizer which was used in analysis are No Economizer(NE), Differential Dry-bulb Temperature(DT), Diffrential Enthalpy(DE), Differential Dry-bulb Temperature+Differential Enthalpy(DTDE), and Differential Enthalpy+Differential Dry-bulb Temperature (DEDT). In addition, the system heating and cooling load were analyzed by calculating the outdoor air fraction through existing AHU operating method and control types for economizer. Result: Optimized outdoor air fraction through control types was the lowest in March and distribution over 50% was shown in May. In case of DE control type, outdoor air fraction was the highest of other control types and the value was average 63% in May. System heating load was shown the lowest value in NE, however, system cooling load was shown 1.7 times higher than DT control type and 5 times higher than DE control type. For system heating load, DT and DTDE is similar during intermediate season. However, system cooling load was shown 3 times higher than DE and DEDT. Accordingly, it was found as the method to save cooling energy most efficiently with DE control considering enthalpy of outdoor air and return air in intermediate season.

Dynamic stability analysis of laminated composite plates in thermal environments

  • Chen, Chun-Sheng;Tsai, Ting-Chiang;Chen, Wei-Ren;Wei, Ching-Long
    • Steel and Composite Structures
    • /
    • v.15 no.1
    • /
    • pp.57-79
    • /
    • 2013
  • This paper studies the dynamic instability of laminated composite plates under thermal and arbitrary in-plane periodic loads using first-order shear deformation plate theory. The governing partial differential equations of motion are established by a perturbation technique. Then, the Galerkin method is applied to reduce the partial differential equations to ordinary differential equations. Based on Bolotin's method, the system equations of Mathieu-type are formulated and used to determine dynamic instability regions of laminated plates in the thermal environment. The effects of temperature, layer number, modulus ratio and load parameters on the dynamic instability of laminated plates are investigated. The results reveal that static and dynamic load, layer number, modulus ratio and uniform temperature rise have a significant influence on the thermal dynamic behavior of laminated plates.

A Study of Temperature Characteristic and Recording Quality Improvement of Blu-ray Laser Diode for Optical Media Recording (광학 디스크 기록을 위한 Blu-ray Laser Diode의 온도특성 및 기록품질 개선에 관한 연구)

  • Lee, Do-Han;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.503-505
    • /
    • 2009
  • In this paper, we research the method for write quality improvement by temperature characteristic of Laser diode for optical recording. Differential Resistance of Blu-ray laser diode is changed by temperature. We analyze the effect of the change of the differential resistance and propose the method for the write quality improvement.

  • PDF

A Study of Rolling Characterization on Mg Alloy Sheet (마그네슘 합금 판재의 압연특성연구)

  • Jeong, Y.G.;Lee, J.B.;Kim, W.J.;Lee, G.A.;Choi, S.;Jeong, H.G.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.53-56
    • /
    • 2006
  • Magnesium alloy AZ31, which processed by conventional rolling or extrusion, has high anisotropy of mechanical properties in its strength and elongation at room temperature. We compared the influence of differential speed rolling with conventional rolling process on microstructure and mechanical properties of commercial AZ31 sheet. Commercial AZ31 alloy sheets were processed with conventional and differential speed rolling with thickness reduction ratio of 30% at a various temperature. The elongation of AZ31 alloy, warm-rolled by differential speed rolling is larger than those rolled by conventional rolling. Besides, grain size and distribution on microstructure of the conventional rolled materials were coarse and inhomogeneous, on the contrary, those of the differential speed rolled were fine and homogeneous.

  • PDF

The Effect of DSC Analysis Condition on the Glass Transition Temperature of curred Epoxy This paper studies on the effect of DSC(Differential Scanning Calorimeter) analysis condition on the glass transition temperature of silica filled epoxy network polymer used for ultra-high voltage apparatus. The effects of temperature scanning rate specimen size and gas flow rate on measured glass transition temperature have been studied in order to select optimum thermal analysis condition. (에폭시 경화물 DSC에 의한 유리전이 온도 측정의 분석조건 의존성)

  • 오무원;권혁삼
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.30-33
    • /
    • 1994
  • This paper studies on the effect of DSC(Differential Scanning Calorimeter) analysis condition on the glass transition temperature of silica filled epoxy network polymer used for ultra-high voltage apparatus. The effects of temperature scanning rate specimen size and gas flow rate on measured glass transition temperature have been studied in order to select optimum thermal analysis condition.

  • PDF

Thermal-flow analysis of a simple LTD (Low-Temperature-Differential) heat engine

  • Kim, Yeongmin;Kim, Won Sik;Jung, Haejun;Chen, Kuan;Chun, Wongee
    • Journal of Energy Engineering
    • /
    • v.26 no.1
    • /
    • pp.9-22
    • /
    • 2017
  • A combined thermal and flow analysis was carried out to study the behavior and performance of a small, commercial LTD (Low-Temperature-Differential) heat engine. Laminar-flow solutions for annulus and channel flows were employed to estimate the viscous drags on the piston and the displacer and the pressure difference across the displacer. Temperature correction factors were introduced to account for the departure from the ideal heat transfer processes. The analysis results indicate that the work required to overcome the viscous drags on engine moving parts and to move the displacer is much smaller than the moving-boundary work produced by the power piston for temperature differentials in the neighborhood of $20^{\circ}C$ and engine speeds below 10 RPS. A comparison with experimental data reveals large degradations from the ideal heat transfer processes. Thus, heat-transfer devices inside the displacer cylinder are recommended.

Development of Environmental Load Calculation Method for Airport Concrete Pavement Design (공항 콘크리트 포장 설계를 위한 환경하중 산정방법 개발)

  • Park, Joo-Young;Hong, Dong-Seong;Kim, Yeon-Tae;Jeong, Jin-Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.729-737
    • /
    • 2013
  • The environmental load of concrete pavement can be categorized by temperature and moisture loads, which mean temperature distribution, and drying shrinkage and creep in the concrete slab. In this study, a method calculating the environmental load essential to mechanistic design of airport concrete pavement was developed. First, target area and design slab thickness were determined. And, the concrete temperature distribution with slab depth was predicted by a pavement temperature prediction program to calculate equivalent linear temperature difference. The concrete drying shrinkage was predicted by improving an existing model to calculate differential shrinkage equivalent linear temperature difference considering regional relative humidity. In addition, the stress relaxation was considered in the drying shrinkage. Eventually, the equivalent linear temperature difference due to temperature and the differential shrinkage equivalent linear temperature difference due to moisture were combined into the total equivalent linear temperature difference as terminal environmental load. The environmental load of eight civilian and two military airports which represent domestic regional weather conditions were calculated and compared by the method developed in this study to show its application.

Experiment and Prediction of Nonlinear Behavior at High Temperatures of Ferroelectric Ceramics Switched by Electric Field at Room Temperature

  • Ji, Dae Won;Kim, Sang-Joo
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.3
    • /
    • pp.235-242
    • /
    • 2017
  • Changes in polarization and thermal expansion coefficients during temperature increase of a poled lead zirconate titanate (PZT) cube specimen switched by an electric field at room temperature are measured. The measured data are analyzed to construct governing differential equations for polarization and strain changes. By solving the differential equations, an experimental formula for the high temperature behavior of ferroelectric materials is obtained. It is found that the predictions by the formula are in good agreement with measures. From the viewpoint of macroscopic remnant state variables, it appears that the processes of electric field-induced switching at different temperatures are identical and independent of temperature between $20^{\circ}C$ and $110^{\circ}C$.

Variation of Flexural Strength of Warm-mix Asphalt Concretes Due to Differential Thermal Contraction at Low Temperatures (저온하에서 시차열 수축에 의한 WMA 콘크리트의 휨강도 변화)

  • Choi, Jung-Soon;Kim, Sung-Un;Kim, Kwang-Woo
    • International Journal of Highway Engineering
    • /
    • v.14 no.4
    • /
    • pp.63-72
    • /
    • 2012
  • PURPOSES : Hot-mix asphalt(HMA) concretes show a trend of strength increase at low temperature due to binder stiffness increase, but strength decrease below a ceratin low temperature. This is due to the differential thermal contraction(DTC) which is induced by a significant difference in coefficients of thermal contraction between aggregate and asphalt which is coated around the aggregate. This DTC damage is well known to occur in HMA concrete, but is not yet investigated in warm-mix asphalt(WMA) concretes. METHODS : To evaluate DTC damage on WMA in this study, the flexural strength($S_f$) of WMA concretes, which were produced at $30{\sim}40^{\circ}C$ lower temperature, was evaluated in comparison with that of HMA at -5, -15 and $-25^{\circ}C$. RESULTS : Most of WMA and HMA mixtures showed flexural strength increase down to $-15^{\circ}C$ and decrease below $-15^{\circ}C$. this type of strength reduction below $-15^{\circ}C$ can e explained as the effect of differential thermal contraction that is a consequence of the large difference in coefficients of thermal contraction between aggregate and asphalt. the property reduction of WMA is similar the result of previous works dealt with HMA mixtures. CONCLUSIONS : Even though there is some differences by materials used, the WMA concretes showed a significantly lower DTC damage than HMA concrete at low temperature at ${\alpha}$=0.05 level.