• 제목/요약/키워드: temperature cycles

검색결과 882건 처리시간 0.029초

유기농업을 위한 잡초방제기술의 현재 미래 (Status and Prospect of Weed Control Technology for Organic Farming)

  • 전용웅
    • 한국유기농업학회지
    • /
    • 제6권2호
    • /
    • pp.127-140
    • /
    • 1998
  • Organic farming excludes any use of the herbicide. The present paper reviews what can be done for effective weed control with existing weed control technology by farmers crop-ping paddy rice, field crops, vegetables, and fruit trees. If condition of the crop-land-al-lows diversified rotational use of the paddy land as paddy and upland field would minimize weed problem. Practising this is limited in acreage due to extremely limited governmental investment to the land for the purpose. Secondly, rotation of crops in the upland field breaking life cycles of various weeds adapted to each crop should reduce the weed problem. This is also limited as only a few crops are making the farmer profitable. In addition climate and tolerance of crops to high and low temperature. Monsoon rains and poor drainage restrict the freedom of choice. For any crop land year-round multiple cropping in denser planting shall lessen the weed problem, this multiple cropping practiced by 1960s has been abandoned due to laborshortage and increased production cost. Deep flooding the rice is impractical at present in Korean. Mulching crop with transparent, black , or combinated polyethylene sheet, hs been in-creasingly used. Progresses in development and use of mulch with allelopathic crop residues. inexpensive paper mulch, allelopathic crop residues, inexpensive paper mulch, allelopathic crop cultivar development, recently developed ex-perimental weeding machinaries, flamers, microbial herbicides, biological control organisms, soil sterilization techniques have been critically reviewed for their adoption into existing in-tegrated weeding system. Unfortunately, information on cost-benifit, and labor-benefit, for the various methods above mentioned are lacking. Urgent need for the research on rational weeding in organic farming, and herbicide low-input farming is emphasized.

  • PDF

졸-겔법으로 성장시킨 바나듐이 도핑된 ${Bi_4}{Ti_3}{O_{12}}$ 박막의 미세구조 및 전기적 특성 (Microstructure and Electrical Properties of Vanadium-doped ${Bi_4}{Ti_3}{O_{12}}$ Thin Films Prepared by Sol-gel Method)

  • 김종국;김상수;최은경;김진흥;송태권;김인성
    • 한국재료학회지
    • /
    • 제11권11호
    • /
    • pp.960-964
    • /
    • 2001
  • $Bi_{3.99}Ti_{2.97}V_{0.03}O_{12}$ (BTV) thin films with 3 mol% vanadium doping were Prepared on $Pt/Ti/SiO_2/Si$ substrate by sol-gel method. X-ray diffraction analysis indicated that single-phase layered perovskite were obtained and preferred orientation was not observed. Under the annealing temperature at $600^{\circ}C$, the surface morphology of the BTV thin films had fine-rounded particles and then changed plate-like at $650^{\circ}C$ and $700^{\circ}C$. The remanent polarization $(2P_r)$ and coercive field $(2E_c)$ of $700^{\circ}C$ annealed BTV thin film were 25 $\mu$C/cm$^2$ and 116 kV/cm, respectively. In addition, BTV thin film showed little polarization fatigue during $10_9$ switching cycles. These improved ferroelectric properties were attributed to the increased rattling space and reduced oxygen vacancies by substitution $Ti^{4+}$ ion (68 pm) with smaller $V^{5+}$ ion (59 pm). The dielectric constant and loss were measured 130 and 0.03 at 10 kHz, respectively.

  • PDF

방사선 중합에 의한 설폰화 POF-g-Styrene 이온교환 섬유의 합성 및 암모니아 흡착 (Synthesis of Sulfonated POF-g-Styrene ion Exchange Fibers by Radiation-Induced Polymerization and Properties of Ammonia Adsorption)

  • 조인희;백기완;이창수;노영창;윤수경;황택성
    • 폴리머
    • /
    • 제31권1호
    • /
    • pp.1-7
    • /
    • 2007
  • 본 연구는 $Co^{60}\;{\gamma}-ray$ 선원을 이용한 그래프트 공중합 방법으로 설폰형 이온교환 섬유를 합성하였다. 공중합체 합성 시 스티렌 단량체의 농도가 50 v/v%에서 그래프트율이 가장 높게 나타났으며, 총 조사선량이 증가할수록 그래프트율은 증가하였다. 그래프트율과 반응온도가 증가함에 따라 설폰화율은 증가하였으며, 반응시간 20분에서 가장 높았다. 이온교환 섬유의 이온교환 용량과 함수율은 설폰화율이 증가함에 따라 모두 증가하였으며, 각각 최대 4.76 meq/g, 23.5%이었다. 암모니아 흡착량은 이온교환 용량 및 암모니아 농도가 증가함에 따라 증가하였으며, 10회 이상 반복 사용하여도 암모니아 흡착량은 변하지 않았다.

미세튜브 열교환기의 장착을 고려한 구조건전성에 관한 연구 (A Study on the Structural Integrity Considering the Installation of a Micro-tube Heat Exchanger)

  • 오세윤;김태진;조종래;정호승
    • 대한기계학회논문집A
    • /
    • 제39권4호
    • /
    • pp.447-451
    • /
    • 2015
  • 본 연구의 목적은 유한요소 해석을 이용하여 항공기 엔진에 장착된 미세 튜브형 열교환기의 작동하중에 대한 특성을 파악하고 구조안전성을 평가하는 것이다. 작동 하중은 열-기계하중이 고려되었다. 항공기 엔진 부품의 특수성으로 인하여 구조적 강성확보뿐만 아니라 고효율, 저중량, 최소체적을 만족하는 형상 설계가 요구 된다. 브레이징한 미세튜브의 기계적물성치 확보를 위해 고온 인장 실험을 수행하였다. Ansys 12.1의 자체 모델러를 이용하여 형상을 모델링하고 유한요소해석을 수행하였다. 열-구조 연성해석을 통하여 튜브를 제외한 모듈형(modular type) 열교환기에 대한 설계방법을 제시하고 구조적 건전성을 평가하였다.

Halogen Light Curing Unit과 Light Emitting Diodes Curing Unit을 이용하여 중합되어진 복합레진의 마멸 특성 비교 (Wear of Resin Composites Polymerized by Conventional Halogen Light Curing and Light Emitting Diodes Curing Units)

  • 이권용;김환;박성호;정일영;전승범
    • Tribology and Lubricants
    • /
    • 제21권6호
    • /
    • pp.268-271
    • /
    • 2005
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15N contact force in a reciprocal sliding motion of sliding distance of 10mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji II LC specimen was the greatest among all resin composites. Dyract AP showed less wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as curing unit for composite resin restorations.

치아 충전용 복합레진의 광중합 광원 종류에 따른 마멸 비교 (Wear Of Dental Restorative Composite Resins Cured by Two Different Light Sources)

  • 김환;이권용;박성호;정일영;전승범
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2004년도 학술대회지
    • /
    • pp.350-354
    • /
    • 2004
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15 N contact force in a reciprocal sliding motion of sliding distance of 10 mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji ?LC specimen was the greatest among all resin composites. Dyract AP showed less wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as curing unit for composite resin restorations.

  • PDF

이방성 전도 필름을 이용한 플립칩 패키지의 열피로 수명 예측 및 강건 설계 (Robust Design and Thermal Fatigue Life Prediction of Anisotropic Conductive Film Flip Chip Package)

  • 남현욱
    • 대한기계학회논문집A
    • /
    • 제28권9호
    • /
    • pp.1408-1414
    • /
    • 2004
  • The use of flip-chip technology has many advantages over other approaches for high-density electronic packaging. ACF (anisotropic conductive film) is one of the major flip-chip technologies, which has short chip-to-chip interconnection length, high productivity, and miniaturization of package. In this study, thermal fatigue lift of ACF bonding flip-chip package has been predicted. Elastic and thermal properties of ACF were measured by using DMA and TMA. Temperature dependent nonlinear hi-thermal analysis was conducted and the result was compared with Moire interferometer experiment. Calculated displacement field was well matched with experimental result. Thermal fatigue analysis was also conducted. The maximum shear strain occurs at the outmost located bump. Shear stress-strain curve was obtained to calculate fatigue life. Fatigue model for electronic adhesives was used to predict thermal fatigue life of ACF bonding flip-chip packaging. DOE (Design of Experiment) technique was used to find important design factors. The results show that PCB CTE (Coefficient of Thermal Expansion) and elastic modulus of ACF material are important material parameters. And as important design parameters, chip width, bump pitch and bump width were chose. 2$^{nd}$ DOE was conducted to obtain RSM equation far the choose 3 design parameter. The coefficient of determination ($R^2$) for the calculated RSM equation is 0.99934. Optimum design is conducted using the RSM equation. MMFD (Modified Method for feasible Direction) algorithm is used to optimum design. The optimum value for chip width, bump pitch and bump width were 7.87mm, 430$\mu$m, and 78$\mu$m, respectively. Approximately, 1400 cycles have been expected under optimum conditions. Reliability analysis was conducted to find out guideline for control range of design parameter. Sigma value was calculated with changing standard deviation of design variable. To acquire 6 sigma level thermal fatigue reliability, the Std. Deviation of design parameter should be controlled within 3% of average value.

Cold Shock Response of Leuconostoc mesenteroides SY1 Isolated from Kimchi

  • KIM JONG HWAN;PARK JAE-YONG;JEONG SEON-JU;CHUN JIYEON;KIM JEONG HWAN
    • Journal of Microbiology and Biotechnology
    • /
    • 제15권4호
    • /
    • pp.831-837
    • /
    • 2005
  • Low-temperature adaptation and cryoprotection were studied in Leuconostoc mesenteroides SYl, a strain isolated from Kimchi. L. mesenteroides SY1 cells grown in exponential growth phase at $30^{\circ}C$ were exposed to $15^{\circ}C,\;10^{\circ}C$, and $5^{\circ}C$ for 2, 4, and 6 h, respectively, and then frozen at $- 70^{\circ}C$ for 24 h. Survival ratio was measured after the cells were thawed. The freezing-thawing cycles were repeated four times. Preadapted cells survived better than non-adapted control cells, and the highest survival ratio ($96\%$) was observed for cells preadapted for 2 h at $5^{\circ}C$, whereas control cells showed only $22\%$. The 2D gel showed that two proteins (spots A and B) were induced in cells preadapted at lower temperatures. Spots A and B have the same molecular weight (7 kDa), but the pI was 4.6 for spot A and 4.3 for spot B. The first 29 and 15 amino acid sequences from spots A and B were determined, and they were identical, except for one amino acid. A csp gene was cloned, and nucleotide sequencing confirmed that the gene encoded spot A cold shock protein.

Cold Adaptation of Lactobacillus paraplantarum C7 Isolated from Kimchi

  • Kim, Su-Jung;Kim, Jong-Hwan;Park, Jae-Yong;Kim, Han-Taek;Jeong, Seon-Ju;Ha, Yeong-Lae;Yun, Han-Dae;Kim, Jeong-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권5호
    • /
    • pp.1071-1074
    • /
    • 2004
  • The effect of preadaptation at low temperature on cryoprotection was studied for Lactobacillus paraplantarum C7, a bacteriocin producer isolated from kimchi. L paraplantarum C7 cells in their log growth phase were incubated at $15^\circ{C}$, $10^\circ{C}$, or $5^\circ{C}$ for 2, 4, and 6 h, respectively, before being frozen at $-70^\circ{C}$. After 24 h of freezing, viable cells were counted after brief thawing. The freezing-thawing cycles were repeated three more times. Cells preadapted at $10^\circ{C}$ or $5^\circ{C}$ before freezing survived better than control cells, but preadaptation at $15^\circ{C}$ did not confer cryoprotection. Chloramphenicol addition did not destroy the cryoprotection, indicating that protein synthesis was not required for the development of cryoprotection. SDS-PAGE showed induction of a 6.5-kDa protein, a major cold-shock protein, in preadapted cells.

ICP-MS를 사용한 구연산비스마스칼륨 (Tripotassium dicitrato bismuthate)의 생체이용률 측정 (Bioavailability of Tripotassium Dicitrato Bismuthate by ICP-MS in Human Volunteers)

  • 권오승;권지영;윤애린;박경수
    • Journal of Pharmaceutical Investigation
    • /
    • 제37권2호
    • /
    • pp.79-84
    • /
    • 2007
  • This study was aimed to establish analytical method of Bi to develop a guideline of the bioequivalence test of tripotassium dicitrato bismuthate (TDB). For this purpose, a simple, specific and sensitive inductively coupled plasma-mass spectrometry (ICP/MS) method were developed and validated in human plasma. Various concentrations of bismuth standard solution (0-25ng/mL) were prepared with distilled water and human blank plasma. To 10mL of the volumetric flasks, 2mL of blank plasma was added with 8ml of distilled water. Bi standard solution was added to prepare the calibration samples and injected into ICP-MS. The plasma samples obtained from volunteers given 3 tablets of bismuth (total 900mg as TDB) were analyzed as described above. As a result, the coefficients of variation were <20% in quantitation limit (0.2 ng/mL) and <15% at the rest of concentrations. The stability test by repeated freezing-thawing cycles showed that the samples were stable only for 24hr. The stability tested for samples with a short-term period of storage at room temperature and pre-treatment prior to the analysis showed very stable over 24hr. In 8 healthy Korean subjects received Denol tablets at the dose of 900mg bismuth, AUC, $C_{max},\;T_{max}$ and half-life $(t_{1/2})$ were determined to be $198.33{\pm}173.78 ng{\cdot}hr/mL,\;64.48{\pm}27.06 ng/mL,\;0.52{\pm}0.21 hr,\;and\;5.15{\pm}2.67 hr$, respectively, from the plasma bismuth concentration-time curves. In conclusion, the method was suitable for the determination of bismuth in human plasma samples and could be applied to bioequivalence test of bismuth tablet.