• Title/Summary/Keyword: temperature control system

Search Result 3,223, Processing Time 0.031 seconds

Human Detection and Fuzzy Temperature Control System for Energy Reduction of Cooling Device in Elevator (승강기용 냉각장치의 에너지 절감을 위한 사람 검출과 퍼지 온도 제어 시스템)

  • Eum, Hyukmin;Jang, Sukyoon;Lee, Heejin;Park, Mignon;Yoon, Changyong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.2
    • /
    • pp.147-154
    • /
    • 2015
  • In this paper, we propose human detection and fuzzy temperature control system for energy reduction of cooling device in elevator. In order to improve problems of existing cooling device using the refrigerant, energy reduction and efficient management are continuously achieved because of operation of thermoelectric cooling device using the human detection and fuzzy temperature control system. The proposed system confirms the number of passengers in elevator and temperature is then controlled by those numbers and an average temperature for the season in fuzzy system. The human detection method scans the number of passengers using a head part as a feature based on bird's-eye view camera in elevator. The fuzzy system determines elevator internal temperature considering atmospheric temperature and the scanned passenger numbers as a look-up table. The proposed system reduces energy of the cooling device through the human detection and temperature control. In experiment, energy reduction is confirmed and the performance of the proposed system is verified.

Control of the Absorption Air Conditioning System by Using Steepest Descent Method (최속 강하법을 이용한 흡수식 냉동공조시스템 제어)

  • Han, Do-Young;Kim, Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.495-501
    • /
    • 2003
  • Control algorithms for the absorption air conditioning system may be developed by using dynamic models of the system. The simplified effective dynamic models, which can predict the dynamic behaviors of the system, may help to develop effective control algorithms for the system. In this study, control algorithms for an absorption air conditioning system were developed by using a dynamic simulation program. A cooling water inlet temperature control algorithm, a chilled water outlet temperature control algorithm, and a supply air temperature control algorithm, were developed and analyzed. The steepest descent method was used as an optimal algorithm. The simulation results showed energy savings and the effective controls of an absorption air conditioning system.

The Optimal Control of an Absorption Air Conditioning System by Using the Steepest Descent Method

  • Han Doyoung;Kim Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.3
    • /
    • pp.123-130
    • /
    • 2004
  • Control algorithms for an absorption air conditioning system may be developed by using dynamic models of the system. The simplified effective dynamic models, which can predict the dynamic behaviors of the system, may help to develop effective control algorithms for the system. In this study, control algorithms for an absorption air conditioning system were developed by using a dynamic simulation program. A cooling water inlet temperature control algorithm, a chilled water outlet temperature control algorithm, and a supply air temperature control algorithm, were developed and analyzed. The steepest descent method was used as an optimal algorithm. Simulation results showed energy savings and the effective controls of an absorption air conditioning system.

Actuator multiple control method for greenhouse environment control system (온실 환경 제어시스템을 위한 액추에이터 복합 제어 방법)

  • Son, Kyo-Hoon;Park, Dae-Heon;Kim, Se-Han;Kim, Jae-Hyung;Jeung, Eun-Tae
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.11 no.2
    • /
    • pp.39-45
    • /
    • 2012
  • In recent years the USN(Ubiquitous Sensor Networks) technology has been applied in the greenhouse in order to control temperature and humidity automatically. In this paper, we proposed a control algorithm using feedback linearization techniques based on a mathematical model for temperature and humidity environment. Especially, Control algorithm is presented to the operation of the ventilator affecting on the temperature and humidity system at the same time. The System has been designed taking into account the disturbance(External temperature, soil temperature, external humidity, solar radiation and wind). In conclusion, I will present a way to control multiple actuator through simulations. The proposed control algorithm is validated using the Matlab/Simulink tools.

  • PDF

A Temperature Management of Mass Concrete for Crack Control in Machine Foundation (기계기초 매스콘크리트의 균열제어를 위한 온도관리)

  • 허택녕;이제방;손영현
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.394-401
    • /
    • 1996
  • This paper persents the crack control of mass concrete in massive machine foundation. The dimension of the machine foundation is 52.6m$\times$14.4m$\times$8.5m. The one distinctive characteristic of mass concrete is thermal behavior. Since the cement-water reaction is exothermic by nature, the temperature rises inside the massive concrete structure. When the heat is not quickly dissipated, it can be quite high. Significant tensile stresses may develop from the volume change associated with the increase of decrease of temperature within the mass concrete structure. To avoid occurrence of harmful cracks due to hydration heat, special attention shall be given to the construction of mass cnocrete structures. The temperature control system of mass concrete is proposed in this paper. This system contains a discussion of materials and concrete mix proportioning, thermal analysis, curing method, temperature control, and measurement of hydration heat. As will be seen throughout the paper, the proposed temperature control system have a great effect on the temperature-related cracks on mass concrete structures.

  • PDF

A Study on the Improvement of Indoor Thermal Performance of Floor Radiant Heating System Considering Valve Operation Characteristics (바닥복사 난방시스템의 밸브구동 특성을 고려한 실내 열환경 성능 개선 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.4
    • /
    • pp.36-45
    • /
    • 2021
  • In this study, to improve the indoor thermal environment of the radiant floor heating system, a study was conducted on the temperature change characteristics and energy consumption according to the change of the indoor air set temperature, the supply hot water temperature and the outdoor temperature. As for the control method, the on/off control and the thermal difference proportional control method proposed through previous studies were applied. In addition, in consideration of field applicability, numerical analysis was performed for the case where the indoor air temperature sensor was affected by the wall temperature. As a result, it was found that the temperature difference proportional control method is more effective for thermal comfort and energy saving than on/off control.

Auto plant control system by using Arduino

  • Chowdhury, Deb
    • Korean Journal of Artificial Intelligence
    • /
    • v.1 no.1
    • /
    • pp.4-6
    • /
    • 2013
  • In the era of information society, IT industry has been developed very much. New technology has made appearance in citizens' lives. IOT (Internet of Things) has grown up the most rapidly in IT industry. Kevin Ashiton, MIT specialist, said, "Loading of FRIS and other sensors shall build Internet of things." Internet of things is said to let things have sensor and communication module and to exchange information and communicate each other. In this study, Internet of things has been applied to flowerpot to build automatic flowerpot control system that turns fan ON and supplies water depending upon temperature and moisture. Users are difficult to cognize temperature and humidity of flower pot correctly. In this study, an experiment obtained correct value of temperature and humidity to build control system. At the performance test of flower pot, commands turned ON depending upon temperature and humidity. Control system should be added to control water supply quantity and time objectively according to servo motor control. Purpose of further study was to control flower pot by remote system in connection with smart phone application. An application control can make not only temperature and humidity statistics but also server depending upon users' needs to turn fan ON and take actions and to control flower pot.

Effects of Control Methods of Outdoor Air Cooling System on Energy Consumption in Building (외기냉방 시스템의 제어방법이 에너지 소비량에 미치는 영향에 관한 연구)

  • Hwang, Jin-Won;Ahn, Byung-Cheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4253-4259
    • /
    • 2015
  • In this study, the effects of various control methods of outdoor air cooling control system on control characteristics and energy consumption in building are researched by simulation. The system analysis modelling is done by using TRNSYS program package, and the control performances with existing outdoor air cooling methods are compared with the control ones without outdoor air cooling. As a result, appropriate operating temperature conditions of outdoor air cooling system according to outdoor temperature changes are required, and the outdoor air/return air dry bulb temperature comparison control method among the control methods shows best responses in energy savings.

Indoor Temperature Control of an Air-Conditioning System Using Model Predictive Control (모델예측제어를 이용한 에어컨 시스템의 실내온도 제어)

  • Jo, Hang-Cheol;Byeon, Gyeong-Seok;Song, Jae-Bok;Jang, Hyo-Hwan;Choe, Yeong-Don
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.467-474
    • /
    • 2001
  • The mathematical model of a air-conditioning system is generally very complex and difficult to apply to controller design. In this paper, simple models applicable to the controller design are obtained by modeling the air-conditioning system by single-input single-output between compressor speed and indoor temperature, and by multi-input single-output between compressor speed, indoor fan speed and indoor temperature. Using these empirical models, model predictive control(MPC) technique was implemented for indoor temperature control of the air-conditioning system. It has been shown from various experiments that the indoor temperature control based on the MPC scheme yields reasonably good tracking performance with smooth changes in plant inputs. this multi-input multi-output MPC approach can be extended to multi air- conditioning systems where the conventional PID control scheme is very difficult to apply.

An Experimental Study on the Control of the Combustion Rate by Temperature Control of Gas Entrained into the Filter in Burner-Type Particulate Trap (버너방식 DPF 시스템에서 가스온도 제어를 통한 입자상물질 연소율제어의 실험적 검증)

  • Park, D. S.;Kim, J. U.;Cho, H.;Kim, E. S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.4
    • /
    • pp.130-141
    • /
    • 1997
  • Work on the reduction of particulate matter(PM) from a diesel vehicl has led to a new trp system and a control method to control the combustion rate of the PM filtrated in the trap, which was named as 'Active Exhaust Feeding Regeneration(AEFR) System' by its operation mechanism. Ceramic cordierite filter is a major component of the trap and susceptible to thermal shock. Therefore the system should be designed to reduce the peak temperature and temperature gradients in the trap ; these have been considered to be the main factors causing thermal shock of the filter during the regeneration. It uses the engine's exhaust gas partially for the regeneration of the ceramic filter. It controlled bypass flow rate of the engine's exhaust gas precisely to control the temperature of the gas entrained into the filter. Gas temperatures were measured inside filter, and the oxygen concentration at the outlet of the filter was also monitored during the regeneration to analyze the combustion process of the PM. The temperature distributions and temperature gradients in the filter during the regeneration varied widely according to the regeneration control schemes. Finally, this system shows relatively low peak temperature and temperature gradients in the filter during its regeneration. It is considered that this system uses a mew method to control the combustion rate of the PM, which is different from the methods used in the previous studies.

  • PDF