듀얼채널을 적용한 반도체공정용 칠러의 실험적 연구 (An Experimental Study on Semiconductor Process Chiller for Dual Channel)

  • 차동안;권오경
    • 설비공학논문집
    • /
    • 제22권11호
    • /
    • pp.760-766
    • /
    • 2010
  • Excessive heat occurs during semiconductor manufacturing process. Thus, precise control of temperature is required to maintain constant chamber-temperature and also wafer-temperature in the chamber. Compared to an industrial chiller, semiconductor chiller's power consumption is very high due to its continuous operation for a year. Considering the high power consumption, it is necessary to develop an energy efficient chiller by optimizing operation control. Therefore, in this study, a semiconductor chiller is experimentally investigated to suggest energy-saving direction by conducting load change, temperature rise and fall and control precision experiments. The experimental study shows the cooling capacity of dual-channel chiller rises over 30% comparing to the conventional chiller. The time and power consumption in the temperature rising experiment are 43 minutes and 8.4 kWh, respectively. The control precision is the same as ${\pm}1^{\circ}C$ at $0^{\circ}C$ in any cases. However, it appears that the dual channel's control precision improves to ${\pm}0.5^{\circ}C$ when the setting temperature is over $30^{\circ}C$.

슬래브축열의 최적제어방책에 관한 연구 -평가요소로 복사열의 고려 유무에 의한 차이- (A Study on the Optimal Control Strategy of Air-Conditioning System with Slab Thermal Storage - The Difference by the Presence of Radiant Heat as a Criterion Factor -)

  • 정재훈;신영기
    • 설비공학논문집
    • /
    • 제18권4호
    • /
    • pp.287-296
    • /
    • 2006
  • In this paper, optimal control strategy of the air-conditioning system with slab thermal storage was investigated based on the optimal control theory. An optimal heat output to the plenum chamber and the air-conditioned room was determined based on two kinds of criterion functions. The first one requires small deviation in room air temperature from a set-point value and low energy consumption. It is shown that the optimized control is to store heat through the whole storage time and to increase storage rate gradually with time. As the second case, a criterion that both a deviation of operative temperature from a set-point temperature and the energy consumption should be minimized was adopted. The room air temperature was a little high and the cooling load during storage time was reduced, compared with the results when a criterion function considering only the room air temperature is used.

무창돈사 내 무창기공형 집열기 제어 시스템 개발을 위한 기초적 연구 (A Fundamental Study for Development of Unglazed Transpired Collector Control System in Windowless Pig House)

  • 문병은;김희태;김종구;유영선;김현태
    • 농업생명과학연구
    • /
    • 제50권2호
    • /
    • pp.175-185
    • /
    • 2016
  • 본 연구에서는 UTC 시스템을 대표적인 농업시설인 돈사에 적용하기에 앞서, UTC 제어 시스템 및 프로그램 개발에 따른 돈사 내 적정 사육 환경 유지 및 난방에너지 저감을 위한 기초자료로 활용하고자, 2동의 실험돈사를 제작, UTC 제어 시스템 적용에 따른 실험돈사 내부 온도 변화 및 에너지를 비교, 분석하였다. 제어 시스템은 T1~T4, 총 4점의 온도를 측정 후 프로그램 내 알고리즘에 의해 O1~O5, 총 5개의 출력 신호를 ON/OFF 방식으로 각각 제어하도록 구성하였다. 온도 설정은 실험돈사 내부 온도 28.0℃, UTC 내부 온도 34.0℃로 설정하였고, 측정된 온도와 비교를 통해 출력 신호를 제어하였다. 3일간, 제어 시스템을 가동한 돈사의 경우 최고 온도는 평균 31.8℃로 측정되었다. 같은 시간, 비교돈사의 최고 온도는 평균 36.6℃로 제어 시스템을 가동한 돈사의 내부 온도가 약 4.8℃ 낮은 것으로 나타났다. 또한 제어 프로그램의 가동에 따라 UTC 플레넘 최고 온도는 평균 50.5℃까지 상승한 것으로 나타났다.

철도차량용 LED전조등의 수명시험용 온도제어부의 성능평가 (Performance Assessment of a Temperature Control Unit used in a Lifecycle Testing System for LED Headlamps on Locomotives)

  • 온정근;정기석;정종덕
    • 한국철도학회논문집
    • /
    • 제19권1호
    • /
    • pp.46-53
    • /
    • 2016
  • LED 광원은 기존 광원에 비해 수명이 길고 에너지 효율이 좋은 것으로 알려져 있다. 최근 철도차량의 고속화에 따른 전방시야 확보와 안전적인 운행을 고려하여 LED광원을 이용한 전조등이 증가하고 있다. 그러나 LED광원의 수명시험 데이터를 근거로 한 제품 수명 평가체계는 구동전류, 온도 및 진동 등 수명-스트레스 인자에 따라 다양한 수명특성을 보인다. LED제품은 주로 온도에 의해 예측된 수명에 미치지 못하는 경우가 일반적이므로 온도제어부의 성능평가는 수명시험 이전에 수행되어야 한다. 본 연구는 철도차량용 LED전조등의 수명시험 장치의 온도제어부 시작품을 제작하고 성능시험 결과를 바탕으로 타당성을 검증한다.

갈륨의 고정점을 이용한 정밀 온도제어 (Precise Temperature Control by Locking on the Fixed point of Gallium)

  • 김태호;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.351-354
    • /
    • 2002
  • The new enhanced method of temperature control need not any reference temperature, the system itself can find the melting temperature of gallium as a reference point by dithering input heat flux. If gallium is in melting state, the latent heat of fusion works, so gallium temperature does not change on dithering input heat flux. Also, the control method can determine the state of gallium; solid, liquid, or melting state by investigating the temperature in gallium. We apply this new temperature stabilization method to stabilize a Fabry-Perot cavity, which serves as a ultimate length measurement technique. We achieved 1 mK-temperature stability and 1.5426 nm/ 95 mm-length stability over 10 hours.

  • PDF

바닥난방 시스템의 열환경 개선을 위한 제어방안 연구 (A Study on Thermal Heating Control Performance of Automatic Thermostatic Valves in Floor Radiant Heating System)

  • 송재엽;안병천;김경철;장사윤
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.973-978
    • /
    • 2009
  • In this study, the thermal environment characteristics of On-Off control and thermal difference proportional control method in floor radiant heating system were researched by computer simulation. For the analysis of unsteady heat transfer phenomena in household, the method of using electrical equivalent R-C circuit is applied, and radiation heat transfer between panel, ceiling and walls in household is calculated by enclosure analysis method. The parametric study on two control methods, conventional on-off control and temperature error based time control(T.E.B.T.C.) method, are performed to compare thermal heating control performances, respectively.

  • PDF

멀티형 냉방시스템의 압축기 제어 (Compressor Control of a Multi-type AIr Conditioning System)

  • 한도영;권형진
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.780-786
    • /
    • 2001
  • For the compressor speed control of a multi-type air conditioning system, a fuzzy control algorithm was developed. The sum of zone temperature errors and its derivative were used as input variables, and the compressor speed was selected as the output variable. To test the effectiveness of the control algorithm, one outdoor environmental chamber and four indoor environmental chambers were used. In the chambers the zone temperature step change test and the indoor unit change over test were performed. Test results showed that, for the control of compressor speed, the fuzzy control algorithm was more effective than the conventional proportional control algorithm for the energy conservation.

  • PDF

자동가스 조절용 DC-MOTOR의 실시간 모니터링 시스템 설계 (Design of the Realtime Monitoring System of DC-MOTOR for Automatic gas Control)

  • 조현섭;민병조;오훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2431-2433
    • /
    • 2001
  • Robust control for DC motor is needed according to the highest precision of industrial automation. It is a quite quality concerning to control temperature of single crystalline growth as it does when you get most of heat treating products. It is also important factor to control temperature when you make the A12O3(single crystalline) used to artificial jewels, glass of watches, heat resistant transparent glasses. Thus, it is a major interest to get the proper temperature in accordance with the time process while you are making mixture of oxygen and hydrogen to have the right temperature. In this paper, we will study of electrical valve positioning system for the gas mixture to improve the quality of products.

  • PDF

ON/OFF 제어방식 오일쿨러의 정밀온도 제어에 관한 연구 (A Study on a Precision Temperature Control for Oil cooler using ON/OFF Control Method)

  • 이상윤
    • 융합신호처리학회논문지
    • /
    • 제14권2호
    • /
    • pp.130-135
    • /
    • 2013
  • 최근 공작기계 분야에서 가공속도와 가공정밀도 같은 시스템 성능이 한층 요구되고 있다. 특히 가공속도가 증가함에 따라 공작기계와 수가공 분야의 공작물 가공 부위에 유해한 열 발생을 초래하게 된다. 이 열은 가공 정밀도를 저하시키는 주된 원인으로 작용한다. 따라서 온도를 제어하는 오일쿨러는 공작기계에서 필수적이다. 일반적으로 두 가지 대표적인 제어기법인 핫가스 바이패스 방식과 압축기 가변속 제어 방식이 오일쿨러에 채택 되었다. 본 논문에서는 오일 출구 온도를 설정값으로 유지하기 위해 압축기의 속도를 제어하였다. 공작기계의 정밀 가공이 요구되는 추세에 맞추어 ${\pm}0.1^{\circ}C$의 고정도 온도 제어가 가능한 오일쿨러가 요구된다. 그러나 정밀 온도제어가 가능한 오일쿨러는 가격이 고가이다. 그러므로 본 논문에서는 on/off(릴레이) 제어방식 대신에 PID 제어기와 위상각 전력제어 방식을 사용하여 정밀 온도제어가 가능한 오일쿨러용 제어기를 제안한다. 제안한 제어기를 제작하고, $23^{\circ}C$, $24^{\circ}C$ 그리고 $25^{\circ}C$에서 실험하였다.

인버터를 통한 냉방제어시스템 (The Cooling control system with inverter)

  • 문준수;우이완;박재홍
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.43-48
    • /
    • 2011
  • Cooling system's operation ratio shall be controlled automatically by the internal external temperature sensors in rolling stock. The Cooling System shall be the automatic operation ratio control system which automatically controlling the rotation speed of condenser, evaporator etc. using temperature detection from outside and inside of cabin. This paper will examine the cooling system that can be provide comfortable cooling service for passenger in summer.