• 제목/요약/키워드: temperature control circuit

검색결과 269건 처리시간 0.026초

전자뜸의 시스템 오류에 의한 열폭주 모델 구현 및 해결 방법에 관한 실험적 연구 (An Experimental Study on the Development and Possible Solution of Thermal Runaway Model of Electronic Moxibustion with System Error)

  • 이병욱;오용택;장한솔;최성경;조효림;성원석;김은정
    • Korean Journal of Acupuncture
    • /
    • 제38권4호
    • /
    • pp.282-289
    • /
    • 2021
  • Objectives : The purpose of this study is to construct a model of the possible thermal runaway of electronic moxibustion and to implement an appropriate risk management method. Methods : To reproduce the system error situation of the electronic moxibustion circuit equipped with microcontroller unit, temperature sensor and heater, a code was set to disable the signal input to temperature sensor and maintain "high" heating signal to heater. The temperature change of electronic moxibustion was compared between 3 types of heater module; module 1 consisting of a combination of heater+0 ohm+0 ohm resistance, module 2 consisting of a combination of heater+Polymeric Positive Temperature Coefficient (PPTC)+0 ohm resistance, and module 3 consisting of a combination of heater+PPTC+10 ohm resistance. The temperature change was measured using a polydimethylsiloxane (PDMS) silicone phantom. After maintaining surface temperature of the phantom at 31~32℃ for 20 seconds, electronic moxibustion was applied. After operating electronic moxibustion, the temperature change was measured for 660 seconds on the surface and 900 seconds at 2 mm depth. Results : Regardless of the module type, the time-dependent change in temperature showed a rapid rise followed by a gentle curve, and a sharp drop in temperature after reaching the maximum temperature about 10 minutes after the switching the moxibustion on. Temperature measured at the depth of 2 mm below the surface increased slower and to a lesser extent. Module 1 reached highest peak temperature with largest change of temperature at both depths followed by module 2, and 3. Conclusions : Through the combination of PPTC+resistance with the heater of electronic moxibustion, it is possible to limit the rise in temperature even with the software error. Thus, this setting can be used as an independent safety measure for the electronic moxibustion control unit.

초음파 펄스 서모그라피를 이용한 세라믹 전열 판의 결함 검출 (Defect Detection of Ceramic Heating Plate Using Ultrasound Pulse Thermography)

  • 조재완;서용칠;정승호;김승호;정현규
    • 한국세라믹학회지
    • /
    • 제43권4호
    • /
    • pp.259-263
    • /
    • 2006
  • The applicability of UPT (Ultrasound Pulse Thermography) for real-time defect detection of the ceramic heating plate is described. The ceramic heating plate with superior insulation and high radiation is used to control the water temperature in underwater environment. The underwater temperature control system can be damaged owing to the short circuit, which resulted from the defect of the ceramic heating plate. A high power ultrasonic energy with pulse duration of 280 ms was injected into the ceramic heating plate in the vertical direction. The ultrasound excited vibration energy sent into the component propagate inside the sample until they were converted to the heat in the vicinity of the defect. Therefore, an injection of the ultrasound pulse wave which results in heat generation, turns the defect into a local thermal wave transmitter. Its local emission is monitored and recorded via the thermal infrared camera at the surface which is processed by image recording system. Measurements were Performed on 4 kinds of samples, composed of 3 intact plates and the defect plate. The observed thermal image revealed two area of crack in the defective ceramic heating plate.

태양열 축열조가 없는 변유량 제어 방식의 지역난방용 태양열시스템 실증시험연구 (The Development of the Climatic Design Tool for Energy Efficient Building Design)

  • 백남춘;신우철;이진국;윤응상;윤석만
    • 한국태양에너지학회 논문집
    • /
    • 제28권5호
    • /
    • pp.21-27
    • /
    • 2008
  • In this study, the design of the solar heating system for district heating as well as it's operating characteristics and the performance analysis was carried out. This solar district heating system was composed of two different types of solar collector circuit, flat plate and vacuum tube solar collector, in a system. This system supply constant temperature of hot water without solar buffer tank. For this, the proportional(variable flow rate) control was used. The experimental facility for this study was used the Bundang district solar heating system which was installed in the end of 2006. The operating characteristics and behaviour of each collector circuits are investigated especially for the system design and control. The yearly solar thermal efficiency is 47.5% on the basis of aperture area and 39.8% on the basis of gross area of collector. As a result this solar heating system without solar buffer tank and with proportional controller was testified a very effective and simplified system for district heating. It varied especially depend on the weather condition like as solar radiation and ambient temperature.

다중 추적식 태양광 발전 감성형 LED 가로등 (Solar Power Emotional LED Lightening Street Lamps with Multiple Control Sun Tracker)

  • 이재민;김용;배철수;권대식
    • 한국산학기술학회논문지
    • /
    • 제12권2호
    • /
    • pp.920-926
    • /
    • 2011
  • 본 논문에서는 신재생에너지 활용을 위한 다중 추적식 태양광 발전 감성형 LED 가로등을 제안한다. 제안하는 가로등 시스템은 다중 추적방식의 태양광 추적기능을 갖추고 있고 감성형 고품위 LED 램프와 제어회로를 사용하여 센서를 통해 입력되는 온도 및 습도를 기반으로 최대의 일조량을 받을 수 있도록 하였다. 신재생에너지 활용의 핵심 요소인 효율적인 축전지 활용을 위해 충방전 컨트롤러를 개발하였고 원격모니터링 기능 및 제어기능도 구현 하였다. 제안하는 가로등 시스템은 기존 기술에 비하여 추적 동작이 우수하고 에너지효율이 향상되었으며 기존에 개발되지 않았던 추적식 태양광 발전 시스템과 감성형 LED를 결합함으로써 차세대 가로등 시스템의 모델로서의 활용될 수 있게 하였다.

패치형 무선 피부 온도 측정 시스템의 설계 및 구현 (Design and implement of patch type wireless skin temperature measuring system)

  • 우상효;박수영;지아 모이 우딘;원철호;이정현;박희준;이정우;홍영진;서진호;염영일;조진호
    • 센서학회지
    • /
    • 제17권5호
    • /
    • pp.350-360
    • /
    • 2008
  • In every large hospital, nurses must perform simple repetitive tasks such as measuring body temperature. Such tedious work reduces nurses' motivation to provide quality medical care, which is an important element of the medical services provided by a hospital. If a device were available to measure body temperature, nurses could focus on the more important aspects of providing quality medical care to the patients. However, body temperature is generally measured from the throat, anus, tympanum or armpit, where it is difficult to affix a patch type device. In addition, general body temperature measuring points shows moving artifact error; therefore, it is not good point to continually measure the temperature. In this paper, a patch type skin temperature measuring system was developed. To appropriately measure the skin temperature, a thermal transducer was implemented with a thin (0.5 mm) temperature sensor. The system is small and thin ($H6.6{\sim}5.3{\times}L35{\times}W24\;mm$), and weighs only 5 g including a battery, case and circuit; therefore, it is small and light enough to function as a patch type device. Moreover, the system worked for 5 days. To investigate differences between the experimental and conventional thermometer, simple clinical experiments were performed with 17 volunteers, and the result showed some correlation between the implemented system and conventional thermometer (Correlation coefficient = 0.647, P<0.1).

로컬 클록 스큐 보상을 위한 낮은 지터 성능의 지연 고정 루프 (A Low Jitter Delay-Locked Loop for Local Clock Skew Compensation)

  • 정채영;이원영
    • 한국전자통신학회논문지
    • /
    • 제14권2호
    • /
    • pp.309-316
    • /
    • 2019
  • 본 논문은 로컬 클록 왜곡을 보상하는 낮은 지터 성능의 지연 고정 루프를 제시한다. 제안된 DLL은 위상 스플리터, 위상 검출기(PD), 차지 펌프, 바이어스 생성기, 전압 제어 지연 라인(Voltage Controlled Delay Line) 및 레벨 변환기로 구성된다. VCDL(: Voltage Controlled Delay Line)은 CML(: Current Mode Logic)을 사용하는 자체 바이어스 지연 셀을 사용하여 온도에 민감하지 않고 잡음을 공급한다. 위상 스플리터는 VCDL의 차동 입력으로 사용되는 두 개의 기준 클록을 생성한다. 제안된 회로의 PD는 CML에 비해 적은 전력을 소비하는 CMOS 로직을 사용하기 때문에 PD는 위상 스플리터의 유일한 단일 클록을 사용한다. 따라서 VCDL의 출력은 로컬 클록 분배 회로뿐만 아니라 PD에 사용되므로 레벨 변환기에 의해 레일-투-레일 신호로 변환된다. 제안된 회로는 $0.13{\mu}m\;CMOS$ 공정으로 설계되었으며, 주파수가 1GHz인 클록이 외부에서 인가된다. 약 19 사이클 후에 제안된 DLL은 잠금이 되며, 클록의 지터는 1.05ps이다.

정전류와 부 열저항 특성을 갖는 AC Direct Driver를 이용한 LED 형광등 개발 (Design of a AC driver with constant current and negative temperature resistance for a LED lamp)

  • 김현조;손경민;김민;김관형;변기식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 춘계학술대회
    • /
    • pp.382-384
    • /
    • 2013
  • LED는 일반 백열등에 비해 훨씬 밝으면서도 저전력이라는 장점을 지니고 있다. 이에 기존 형광등이 지니는 효율적, 환경적 문제점을 개선하기 위해 LED형광등의 개발과 상용화가 이루어 졌다. LED는 형광등과 달리 극성을 지니는 단방향성 소자로 교류전원을 직접 쓸 수 없기 때문에 전원공급장치를 필요로 한다. 이 전원공급장치는 부피가 크고 가격이 비싸기 때문에 유지비용면에서 일반 형광등에 비해 기능성이 떨어진다. 본 연구에서는 이 전원공급장치를 대신하여 간략하게 AC전원을 정류하고, 전압변동에 따른 전류변화로 인한 빛의 밝기가 변하는 현상을 없애기 위해 정전류로 제어할 수 있는 회로를 구성하고 이를 LED모듈과 구분하여 Plug in/out 방식의 교체형 모듈로 구성하여 유지보수에 있어 저렴하고 손쉬운 교체가 가능한 소자개발방법을 제안하고자 한다.

  • PDF

ESS (에너지 저장장치) 배터리 화재사례를 통한 감식기법 및 연소 확산방지에 관한 연구 (A Study on the Identification Technique and Prevention of Combustion Diffusion through ESS (Energy Storage System) Battery Fire Case)

  • 이정일
    • 한국재난정보학회 논문집
    • /
    • 제16권2호
    • /
    • pp.383-391
    • /
    • 2020
  • 연구목적 : 에너지 저장실의 외부 화염에 의한 내부자기 점화 및 점화를 식별하고, 과열로 인한 점화와 외부 열원에 의한 점화의 차이를 분석하는 것이다. 연구방법 : 분리막 녹는점 측정, 배터리 외부 수열 실험, 배터리 과충전 실험, 과충전과 외부수열에 의한 연소 시 전극 판 비교분석, 과충전 연소 특징, 외부수열 화재 연소특징, 3.4(전극판 비교)/ 3.5(과충전)/ 3.6(외부수열) 분석 실험을 하였다. 연구결과: 화재 발생 시까지 센서의 위치에 따른 온도 차이가 극심했음으로 기존처럼 한 모듈 당 온도 센서 두 개로는 측정값이 부족해 온도제어를 통한 화재를 사전에 방지할 수 없다고 판단한다. 결론: 단락이 점화원으로 작용하여 혼합가스에 착화돼 가스폭발이 발생하고, 폭발 압력에 의해 전극이 잘게 파손되며, 가루형태의 리튬산화물이 불꽃반응에 의해 폭죽과 유사한 불꽃이 분출되었다.

관광동굴의 환경친화적 관리 방안에 관한 연구 (Pro-environmental Maintenance and Management of Tour Cave : The Currents, Problems and Alternatives in Korea)

  • 유영준;이경호
    • 동굴
    • /
    • 제59권
    • /
    • pp.21-36
    • /
    • 1999
  • Most scholars calssify caves into natural resource, but caves possess values of natural and human resource, mix up the features of natural resources and human resources. Now, caves are distributed 260 in Korea. Seongryu Cave is showed in 1967 for the first time, till 1997 12 caves is opened to tourist. But since 1996 the 12 show caves of all is not launched the safety and environment-protection check-up adduced reason for IMF. Then caves must maintain environment of the normal temperature, humidity and dark. But the environment of caves are destroyed by tourism development. Thus to maintain environment of caves, it used to consider the counterplan as follows in restraint of the environmental change. Firstly, in case of development work to open caves, it must keep up with the prototype. Secondly, it must establish a freight depositary to prevent the influence of the caves's stain and damage due to tourist's objects. Thirdly, to maintain the normal temperature and humidity, it must install artificial poultice equipment of the inner parts of caves. Fourthly, in order to prevent the occurrence of $CO_2$, it must assessment of the optimum number of the greatest stayer. Fifthly, the control of closure for a given period of time is useful of the restoration to the cave's original state. Sixthly, by means of make narrow entrance, it should not influence the outer's air on the inner parts on caves. Seventhly, to keep the temperature of the inner part of caves, the lightening should be maintained moderately considering the convenience of a tour. Eightly, when water-proof cables for the lightening bulbs are connected each other, silicon tape is suitable and circuit breakers should be installed at the diverging points of the cables. Ninthly, the direction and angle of the lightening must be changed periodically to prevent green-pollution at the lightening spot. Lastly, when facilities and arrangements are equipped, corrosive materials should be excluded if circumstances allow.

  • PDF

Cu2ZnSn(S,Se)4(CZTSSe) 흡수층의 급속 열처리 공정 온도 미세 조절을 통한 특성 향상 (Improvement in Performance of Cu2ZnSn(S,Se)4 Absorber Layer with Fine Temperature Control in Rapid Thermal Annealing System)

  • 김동명;장준성;비제이 가라데;김진혁
    • 한국재료학회지
    • /
    • 제31권11호
    • /
    • pp.619-625
    • /
    • 2021
  • Cu2ZnSn(S,Se)4 (CZTSSe) based thin-film solar cells have attracted growing attention because of their earth-abundant and non-toxic elements. However, because of their large open-circuit voltage (Voc)-deficit, CZTSSe solar cells exhibit poor device performance compared to well-established Cu(In,Ga)(S,Se)2 (CIGS) and CdTe based solar cells. One of the main causes of this large Voc-deficit is poor absorber properties for example, high band tailing properties, defects, secondary phases, carrier recombination, etc. In particular, the fabrication of absorbers using physical methods results in poor surface morphology, such as pin-holes and voids. To overcome this problem and form large and homogeneous CZTSSe grains, CZTSSe based absorber layers are prepared by a sputtering technique with different RTA conditions. The temperature is varied from 510 ℃ to 540 ℃ during the rapid thermal annealing (RTA) process. Further, CZTSSe thin films are examined with X-ray diffraction, X-ray fluorescence, Raman spectroscopy, IPCE, Energy dispersive spectroscopy and Scanning electron microscopy techniques. The present work shows that Cu-based secondary phase formation can be suppressed in the CZTSSe absorber layer at an optimum RTA condition.