• Title/Summary/Keyword: temperature and illumination

Search Result 401, Processing Time 0.035 seconds

A STUDY ON THE ILLUMINATION OF DENTAL CLINIC (치과 진료실의 조명에 관한 실태 조사연구)

  • Choi Jong-In;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.374-382
    • /
    • 2006
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental clinics in order to contribute improvement of operating environment. This study also aimed exploring qualitative and quantitative luminous intensity required for color temperature in dental clinic illumination, which was a critical part of esthetic dentistry. Materials and methods: A total of forty-eight local dental clinics were selected for sampling a) luminous intensity, and b) color temperature. The author measured the luminous intensity and the color temperature with lux meter and color meter respectively between 12pm and 2pm. The dental unit chair placed in the general operation positions were kept the distance 60 cm then all dental units were measured three times and averaged. The author measured the luminous intensity and color temperature with both common dental operating light and then without operating light in different office environments. The study was conducted under three conditions: 1 artificial illumination in clear day light 2. artificial illumination in cloudy day light, and 3. artificial illumination alone. Results : The results obtained were as follows. 1. The average luminous intensity in dental clinic lighting was 425 lux which was not sufficient to produce the optimal shade of the patient's teeth. Furthermore, the average luminous intensity even in full operating lighting was 9532 lux which fell short of the required level of 10,000 lux. 2. The average color temperature of all dental clinics surveyed was 5169 K which met the optimal range. However, only 33.3% fell in the correct region between 5,000-5,500 K as 25% were over 5,500 K and 41.6% were below 5,000 K. As a result, 66.7% were under insufficient color temperature conditions. 3. The dental unit chair placed next to a window, hence exposure to natural lighting, had significantly higher luminous intensity and color temperature compared to the dental unit chair which didn't have a window or natural lighting. 4. The data analysis revealed that only 6.3% of the dental clinic were met the standard of the average luminous intensity and color temperature.

Objective Evaluation of Learning Performance according to the Color Temperature of LED Illumination (LED 조명의 색 온도에 따른 학습 성과의 객관적 평가)

  • Jee, Soon-Duk;Kim, Chae-Bogk
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.2
    • /
    • pp.25-33
    • /
    • 2011
  • This study performs the objective evaluation on simple comparison and calculation works by students under LED illumination conditions according to three types of color temperatures (7000K, 5000K, 3000K) in the classroom, Since the objective of this study is to develop an electric lighting conditions suitable for students in the classroom, the learning performance under three types of LED illumination conditions were analyzed. The 4 kinds of simple tests concerning with learning performance were developed and test results under natural light and LED illumination by 3 types of color temperatures were analyzed. There were differences by t-test in most cases among simple experiment results of different illumination conditions ($p{\leq}.05$). It was confirmed that illumination condition plays an important role when students simply compare words or perform arithmetic calculations. The experimental results of this study might be applied to designing better luminous environment.

  • PDF

Effects of Temperature, Illumination, and Sodium Ascorbate on Browning of Green Tea Infusion

  • Ye, Qian;Chen, Hao;Zhang, Lin Bin;Ye, Jian Hui;Lu, Jian Liang;Liang, Yue Rong
    • Food Science and Biotechnology
    • /
    • v.18 no.4
    • /
    • pp.932-938
    • /
    • 2009
  • Browning of tea infusion is an obstructive factor influencing shelf life of ready-to-drink green tea. Effects of temperature and illumination on the browning of green tea infusion were investigated. It was shown that both elevated temperature and illumination led to the browning of green tea infusion, but temperature had greater effect on infusion color and level of catechins than illumination. The levels of unoxidized catechins such as (-)-epigallocatechin gallate (EGCg), (-)-epigallocatechin (EGC), (-)-epicatechin gallate (ECg), (-)-epicatechin (EC), and total catechins remaining in the tea infusion were significantly correlated to color parameters of the tea infusion. Sodium ascorbate inhibited the infusion browning by suppressing the oxidation of tea catechins and it is considered to be a more suitable preservative for prolonging shelf life of ready-to-drink green tea than ascorbic acid because it has less effect on tea taste. The effects of temperature and illumination on the epimerization of catechins were also discussed.

A Study on the Characteristics and Improvement Plans of Illuminance, Color Temperature, and Luminous Sources of Contemporary Korean Protestant Church - Focusing on the Churches Constructed in Seoul Since 2010 - (한국 현대 개신교 예배공간의 조도, 색온도, 광원 특성 및 개선방안에 관한 연구 - 2010년 이후 건축된 서울 지역 교회를 중심으로 -)

  • Jun, Ye-Jin;CHoi, Sang-Hun
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.4
    • /
    • pp.86-93
    • /
    • 2013
  • Illumination in church building has played an important role in making workship space more suitable for divine service. As time has changed, however, the worship space of Protestantism is no longer somber and reverent, but changing into practical and multipurpose space with bright and colorful image. This study investigates intensity of illumination of worship space during day and night respectively and figures out the change of psychological change of congregation in accordance with brightness and color temperature in worship space in order to find out preference and look into the usage and change of illumination in recent Protestantism in compliance with the needs of the time and influence. Then, result value is to be compared to Korean Standard intensity of illumination. Also, the correlation between intensity of illumination and color temperature by Kruithof's curve theory is used to identify the comfortableness of the worship space during day and nigh. And it is a common task of space designers and pastors to map out the worship space in terms of illumination suitable for its own purpose with even more modern and Korean sensibility and to create spiritual space for worshippers by collecting opinions from congregation, the main user of the space. With appropriate usage of illumination in Protestantism worship space, the atmosphere and purpose of worship can be enhanced.

The Effects of Color Temperature on Video in Broadcasting Lighting (방송조명에서 색온도가 영상에 미치는 영향분석)

  • Kim, Yong-Kyu
    • Journal of Broadcast Engineering
    • /
    • v.16 no.1
    • /
    • pp.73-84
    • /
    • 2011
  • In the 2000s, digital HDTV which is sensitive for color temperature and illumination in videos has witnessed many changes to lighting techniques and the next-generation UHDTV will see its resolution being improved up to as 16 times as that of existing high-definition TV. As a result, visible effects by lighting is expected to work more importantly for viewers. When color temperature conversion filters are used for current broadcasting production, the intensity of illumination and luminance can be lowered as well as people's skin tone can be distorted. For this reason, high-quality images are materialized by analyzing the correlation between color temperature, illumination and luminance.

Subjective Evaluation on the Color Temperatures of LED illumination in the Classroom (학교 교실 LED 조명의 색온도에 대한 주관적 평가)

  • Jee, Soon-Duk;Kim, Chae-Bogk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.30-41
    • /
    • 2011
  • This study performs the subjective evaluations of LED illumination conditions according to three types of color temperatures (7,000[K], 5,000[K], 3,000[K]) after employing LED illumination system in the classroom, Since the objective of this study is to develop an artificial lighting conditions like day light comfortable to students in the classroom, the learning effect based on three types of LED illumination conditions are analyzed. Three factors (learning intention, learning environment, learning motivation) are extracted by ANOVA and there are preference differences of LED illumination conditions between learning intention and learning environment factors. Especially, preference differences of LED illumination conditions are existed about calculation, reading and fatigue reduction. The test results of this study can be applied to obtaining high achievement of learning based on the lighting conditions.

A study of illumination of dental laboratories (치과 기공실의 조명에 관한 실태 조사 연구)

  • Lee, Hyo-Jung;Choi, Jong-In;Kim, Sung-Sook;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.4
    • /
    • pp.289-298
    • /
    • 2014
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental laboratories in order to distinguish colors for esthetic dentistry. Materials and Methods: A total of forty-eight local dental laboratories were selected for sampling a) luminous intensity and b) color temperature. We measured the luminous intensity and the color temperature on a center point of porcelain table with lux meter and color meter respectively. The measurements were performed twice, once on a clear day and on a cloudy day between 12 pm and 2 pm (day light and artificial illumination) and between 7 pm and 10 pm (artificial illumination only). Results: The results obtained were as follows. 1. The average luminous intensity in dental laboratories lighting was 1871 lx, and 67% of dental laboratories had luminous intensity greater than 1600 lx, which was appropriate for operations related to colors, while 33% of dental laboratories had in sufficient lighting for appropriate luminous intensity. 2. The average color temperature in dental laboratories lighting was 6506 K, which was inappropriate for operations related to color. None of the dental laboratories had a color temperature range of 5000 - 5500 K, which is appropriate for operations related to colors. 3. Between daytime and nighttime, also between clear day and cloudy day, the average luminous intensity and color temperature in dental laboratories were not significantly different. Conclusion: Illumination in most dental laboratories selected in this study was inappropriate for operations related to color.

Basic Research on Lighting Design for Learning Effect (학습효과 증진을 위한 조명설계에 대한 기초연구)

  • Lee, Boong-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.518-524
    • /
    • 2020
  • This study conducted basic research on an LED lighting design to improve the learning effect from brain wave analysis. The ideal environments of mathematics, language, and creative region can be different. Inside the space where the lighting environment can be experienced directly, the test subject consisted of common elements. Other lighting was blocked completely in controlled lighting conditions. The brain waves were analyzed according to the change in color temperature and illumination. The analyzer used was fabricated by EMOTIV Company. In the variable RGB LED light, the color of the light was measured, and the brain wave of each subject was determined. LED lights have variable color temperature (3000 [K], 4500 [K]. 250 [lux], 70% -350 [lux], 100% -500 [lux]). As research results, the highest concentration in a mathematics study was in the general condition of a high color temperature, in which the optimal condition was a 6000[K] color temperature and 350[lux] illumination. The optimal condition for a language study was a 4500[K] color temperature and 500[lux] illumination, and that of the creative study was 3000[K] color temperature and 500[lux] illumination. Overall, the possibility of emotional ability and concentrated learning efficiency can be improved by the LED lighting design with the color temperature and illumination.

A study on the spray and flame by optically accessible D.I. diesel engine : analysis by Schlieren method and diffused background illumination method (가시용 직분식 디젤기관의 분무와 화염에 관한 연구)

  • 안수길;이덕보;라진홍
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.3
    • /
    • pp.9-23
    • /
    • 1995
  • To analyze the spray and flame in D.I. diesel engine, the visualizing methods by schlieren photograph and diffused background illumination photograph with high speed camera are applied to optically accessible D.I.diesel engine. Wcaporating spray, spray droplets and brightness flame are taken with high speed camera by visuallizing method in accordance with various suction air temperature and injection time. The spray and flame image on the film was analyzed by image analyzer. The optically accessible D.I. diesel engine had the similar pressure characteristic to the real D.I. diesel engine. Experimental results showed that shadow areas of the evaporating spray were extended at higher suction air temperature, spray droplets had a max. Penetration length and their penetrating patterns were dependent on the surrounding gas temperature, and flame size after ignition was largely governed by the evaporated fuel quantity at ignition point and by the surrounding gas condition due to piston motion.

  • PDF