• Title/Summary/Keyword: telerobotic system

Search Result 15, Processing Time 0.029 seconds

Development of Telerobotic Surgery System with Single-Master Multi-Slave (단일마스터 멀티슬레이브형 텔레로보틱스 수술시스템 개발)

  • Hwang, Gil-Gueng;Jin, Tae-Seok;Hashimoto, Hedeki
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.9
    • /
    • pp.918-925
    • /
    • 2006
  • Medical robotics and computer aided surgery in general, and robotic telesurgery in particular, are promising applications of robotics. In this paper, we shows a novel single-master (PHANTOM based single-master multi-slave telerobotic system) multi-slave system using two parallel mechanism micromanipulators as a slave device. After a general introduction to the systems structure and configuration of telerobotic system, a manipulation control strategy to build the system that human and both manipulators perform the cooperative manipulation, is introduced, followed by its kinematic analysis, mapping method, and experimental results.

Development of Control and HMI for Safe Robot Assisted Minimally Invasive Surgery (최소침습수술용 로봇의 안전성을 위한 제어 및 HMI 개발)

  • Jung, Hoi-Ju;Song, Hyun-Jong;Park, Jang-Woo;Park, Shin-Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.9
    • /
    • pp.1048-1053
    • /
    • 2011
  • Recently, robots have been used in surgical area. Robotic surgery in Minimally Invasive Surgery gives many advantages to surgeons and patients both. This study introduce a robotic assistant to improve the safety of telerobotic Minimally Invasive Surgical procedures. The master-slave system is applied to the telerobotic surgical system with the master arm, which control the system, and slave robot which operates the surgery on the patient body. By using a 3-DOF master arm, the surgeon can control the 6-DOF surgical robot under the constraint of fulcrum point. This paper explains the telerobotic surgical system and confirms the system with the precision of the robot control related to the fulcrum point to enhance the safety.

Comparison of Routh-Hurwitz and Absolute Stability Criteria in Application to Scaled Telerobotics Systems (스케일 텔레 로보틱스 시스템에 적용된 Routh-Hurwitz와 절대 안정도 기준의 비교)

  • Gaponov, Igor;Cho, Hyun Chan;Jeon, Hong-Tae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.171-179
    • /
    • 2013
  • This paper presents a comparative study on application of Routh-Hurwitz and Llewellyn absolute stability criteria to a scaled telerobotic system. The dynamic equations of the telerobotic system are given, and the transfer function of the system is obtained for further stability analysis. The stable margins of controller gains are obtained using both stability analysis methods, and the differences in the results are described and explained. The paper is concluded by a numerical example verifying performed stability analysis.

Telerobotic Microsurigical Robot Design based on the analysis of Microsurgery (미세수술 동작분석을 통한 원격제어 수술로봇 설계)

  • 송세경;권동수
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.4
    • /
    • pp.401-407
    • /
    • 1999
  • A microsurgery telerobotic system has been developed to aid surgeons from physiological tremor, eye stram, hand tremor, contagious and radioactive hazard. This paper identifies four general areas of advanced microsurgery and analyzes the motion, tools, accuracy and applying forces with respect to microsurgery tasks, and proposes the criteria to design the microsurgical robot. The analysis of microsurgery can be helpful to clarify some basic concept and design of surgical robots. Based on this analysis results, we propose an efficient in-parallel-platform manipulator having a special kinematic structure suitable for microsurgery.

  • PDF

Design Features and Control Strategies of a Generic Internet Based Telerobotic System

  • Munasinghe, Sudth R.;Lee, Ju-Jang;Ishida, Yuji;Egashira, Naruto;Namakura, Masatoshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1460-1464
    • /
    • 2003
  • This paper describes the design and implementation techniques of a generic Internet based telerobotic system. The purpose is to make precious technical information and hands-on experience of the authors widely available for the research community. The paper is based on the telerobotics system that the authors recently implemented between KAIST and Saga University, Japan. In its current functionality, two control modes can be exercised; high-level supervisory control, and low-level supervisory control.

  • PDF

Implementation and Control of Generic Internet-Based Telerobotic Systems

  • Sudath R. Munasinghe;Lee, Ju-Jang;Yuji Ishida;Naruto Egashira;Masatoshi Nakamura
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.2
    • /
    • pp.220-227
    • /
    • 2004
  • This paper describes the design and implementation techniques of a generic Internet-based telerobotic system. The purpose is to make available the precious technical information and hands-on experience of the authors for the research community. The paper is based on the telerobotics system that the authors recently implemented between KAIST, Korea and Saga University, Japan. In its current functionality, two control modes: high-level supervisory control and low-level supervisory control are explored demonstrating their merits and demerits.

Internet Teleoperation of a Robot with Streaming Buffer System under Varying Time Delays

  • Park, J.H.;J. Kwon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.82.1-82
    • /
    • 2001
  • It is known that existence of irregular transmission time delay is a major bottleneck for application of advanced robot control schemes to internet telerobotic systems. In the internet teleoperation system, the irregular transmission time delay causes a critical problem, which is unstable and inaccurate. This paper suggests a practical internet teleoperation system with streaming buffer system, which consists of a buffer, a buffer manager, and a control timer. The proposed system converts the irregular transmission time delay to constant. So, the system effectively transmits the control input to a remote site to operate a robot stably and accurately. This feature enables short control input interval. That means the entire system has ...

  • PDF

Telerobot System for Biocell Manipulation (바이오셀 조작을 위한 원격조작 로봇 시스템)

  • Gaponov, Igor;Cho, Hyun-Chan
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.3 no.1
    • /
    • pp.193-199
    • /
    • 2011
  • In this paper, we propose a novel manipulator intended for the needs of telerobotic micromanipulation. We designed an original manipulator capable of performing fine motion with an accuracy greater than $2{\mu}m$, while remaining simple in design and easy in control. Preliminary calculations of manipulator accuracy have been conducted, and the device has been designed and manufactured accordingly. The accuracy of the proposed manipulator has been verified during the series micro-positioning experiments under different types of controllers, and the results proved that the manipulator is suitable for micromanipulation applications as a part of telerobotic system. The proposed manipulator has been compared to existing analogues by several parameters, and both its advantages and disadvantages have been discussed.

  • PDF

Sensory Feedback for High Dissymmetric Master-Slave Dexterity

  • Cotsaftis, Michel;Keskinen, Erno
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.1
    • /
    • pp.38-42
    • /
    • 2002
  • Conditions are discussed for operating a dissymmetric human master-small (or micro) slave system in best (large position gain-small velocity gain) conditions allowing higher operator dexterity when real effects (joint compliance, link flexion delay and transmission distortion) are taken into account. It is shown that position PD feedback law advantage for ideal case no longer holds, and that more complicated feedback law depending on real effects has to be implemented with adapted transmission line. Drawback is slowdown of master slave interaction, suggesting to use more advanced predictive methods for the master and more intelligent control law for the slave.