• Title/Summary/Keyword: technology level evaluation

Search Result 2,011, Processing Time 0.031 seconds

Performance Evaluation of Scheduling Algorithm for VoIP under Data Traffic in LTE Networks (데이터 트래픽 중심의 LTE망에서 VoIP를 위한 스케줄링 알고리즘 성능 분석)

  • Kim, Sung-Ju;Lee, Jae Yong;Kim, Byung Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.20-29
    • /
    • 2014
  • Recently, LTE is preparing to make a new leap forward LTE-A all over the world. As LTE privides high speed service, the role of mobile phones seems to change from voice to data service. According to Cisco, global mobile data traffic will increase nearly 11-fold between 2013 and 2018. Mobile video traffic will reach 75% by 2018 from 66% in 2013 in Korea. However, voice service is still the most important role of mobile phones. Thus, controllability of throughput and low BLER is indispensable for high-quality VoIP service among various type of traffic. Although the maximum AMR-WB, 23.85 Kbps is sufficient to a VoIP call, it is difficult for the LTE which can provide tens to hundreds of MB/s may not keep the certain level VoIP QoS especially in the cell-edge area. This paper proposes a new scheduling algorithm in order to improve VoIP performance after analyzing various scheduling algorithms. The proposal is the technology which applies more priority processing for VoIP than other applications in cell-edge area based on two-tier scheduling algorithm. The simulation result shows the improvement of VoIP performance in the view point of throughput and BLER.

Real-scale Accelerated Testing to Evaluate Long-term Performance for Bridge/Earthwork Transition Structure Reinforced by Geosynthetics and Cement Treated Materials (토목섬유와 시멘트처리채움재로 보강한 교량/토공 접속구조의 장기공용성 평가를 위한 실물가속시험)

  • Lee, Il-Wha;Choi, Won-Il;Cho, Kook-Hwan;Lee, Kang-Myung;Min, Kyung-Chan
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.4
    • /
    • pp.251-259
    • /
    • 2014
  • The transition zone between an earthwork and a bridge effect to the vehicle's running stability because support stiffness of the roadbed is suddenly changed. The design criteria for the transition structure on ballast track were not particular in the past. However with the introduction of concrete track is introduced, it requires there is a higher performance level required because of maintenance and running stability. In this present paper, a transition structure reinforced with geosynthetics is suggested to improve the performance of existing bridge-earthwork transition structures. The suggested transition structure, in which there is reinforcing of the approach block using high-tension geosynthetics, has a structure similar to that of earth reinforced abutments. The utilized backfill materials are cement treated soil and gravel. These materials are used to reduce water intrusion into the approach block and to increase the recycling of surplus earth materials. An experiment was performed under the same conditions in order to allow a comparison of this new structure with the existing transition structure. Evaluation items are elastic displacement, cumulative settlement, and earth pressure. As for the results of the real-scale accelerated testing, the suggested transition structure has excellent performance for the reduction of earth pressure and settlement. Above all, it has high resistance the variation of the water content.

Estimation of PM2.5 Correction Factor for Optical Particle Counter in Ambient Air (대기환경에서 광산란 미세먼지 측정기의 PM2.5 보정계수 산정)

  • Kim, Jong Bum;Kim, Danbi;Noh, Sujin;Yoon, Kwan Hoon;Park, Duckshin;Lee, Jeong Joo;Kim, Jeongho
    • Particle and aerosol research
    • /
    • v.16 no.2
    • /
    • pp.49-59
    • /
    • 2020
  • Various devices have been developed to the measurement of particulate matter pollutants, and Optical Particle Counter (OPC) that can be easily and quickly measured is widely used lately. The measured value by OPC is converted to weight concentration using the correction factor (CF). The calculation of CF is very important to improve the reliability and accuracy of OPC. In this study, the CF calculation study of light scattering laser photometer (model 8533, TSI) was carried out to measure in the atmospheric environment using 2 gravimetric devices and 3 light scattering laser photometer devices. Regression analysis and Tukey tests were used to significance the test of measurement devices. Measurements were carried out twice. There was a comparative analysis of measurement data between light scattering laser photometer and gravimetric devices in 1st measurement, and then the Evaluation of PM2.5 concentration corrected by CF performed in 2nd measurement. As a result of the significance analysis between light scattering laser photometer and gravimetric devices, the correlation between the same method was high, but the correlation between different methods was low. CF was calculated as 0.4258 based on the measurement results, and it is a similar level to previous studies at home and abroad. It is expected that these results can be used as basic data in the future study for air quality measurement research using light scattering laser photometer. Also, in order to improve the accuracy of the measurement techniques and the development of technology in the atmospheric environment, CF calculation research should be conducted continuously.

Properties of Red Wine Fermented Using Freeze-Concentrated Muscat Bailey A Grape Juice (동결농축 Muscat Bailey A 포도 과즙으로 제조한 무가당 적포도주의 품질 특성)

  • Hwang, Sung-Woo;Park, Heui-Dong
    • Food Science and Preservation
    • /
    • v.17 no.6
    • /
    • pp.807-813
    • /
    • 2010
  • Muscat Bailey A grapes, one of the major grape varieties in Korea, contain 18-20% (w/w) sugars, which is less than the amount required to make red wine. In the present study, fermentation of freeze-concentrated Muscat Bailey A grape juice to $24^{\circ}Brix$ was performed using several industrial wine yeasts, including Saccharomyces cerevisiae $OC_2$, S. cerevisiae Fermivin and S. cerevisiae W-3. During fermentation, changes in the levels of soluble solids, alcohols, and yeast viable counts were monitored. Wine quality parameters including organic acid, minor alcohol, sensory score, etc. were also analyzed. Alcohol contents reached maximal levels after 9 days of fermentation, and were 12.6% (v/v) when Fermivin was used and 13% (v/v) when strains $OC_2$ and W-3 were used. No major difference between strains was apparent, except that Fermivin fermentation was somewhat slower in terms of both alcohol production and sugar consumption. Similar levels of soluble solids and total phenols were measured in wines fermented by each of the three strains. The total acid level of W-3 wine was high, whereas the alcohol content of Fermivin wine was low. Although the wines were variable in terms of acetaldehyde and minor alcohol contents, the levels of these materials were much lower than the limits set by the Korean National Tax Service. Upon sensory evaluation, $OC_2$ wine obtained the highest scores in terms of color, flavor, and overall acceptance. However, the best taste score was awarded to the Fermivin wine, which had the same flavor score as $OC_2$ wine but a slightly lower overall acceptance score.

Evaluation of EGR applicability for NOx reduction in lean-burn LPG direct injection engine (초희박 LPG 직접분사식 엔진에서 질소산화물 저감을 위한 배기재순환 적용성 평가)

  • Park, Cheolwoong;Cho, Seehyeon;Kim, Taeyoung;Cho, Gyubaek;Lee, Janghee
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.22-28
    • /
    • 2015
  • In order to keep the competitiveness of LPG fuel for transportation fuel, the difference in fuel consumption with gasoline and cost for an aftertreatment system should be reduced with continuous development of technology for LPG engine. In the present study, spray-guided type direct injection combustion system, whose configuration is composed of direct injector in the vicinity of spark plug, was employed to realize stable lean combustion. A certain level of nitrogen oxides($NO_x$) emits due to a locally rich mixture regions in the stratified mixture. With the application of EGR system for the reduction of $NO_x$, 15% of $NO_x$ reduction was achieved whereas fuel consumption and hydrocarbon emission increased. By the application of EGR, the combustion speed reduced especially appeared at initial flame development period and peak heat release rates and increasing rates for heat release rate decreased as EGR rate increased due to the dilution effect of intake air.

Perceptions of Hospital Health Information Managers Regarding Present on Admission Indicators in Korea: A Qualitative Study (입원 시 상병의 수집 및 활용에 관한 보건의료정보관리사의 관점: 질적 연구)

  • Pyo, Jee-Hee;Choi, Eun-Young;Oh, Hae-Mi;Lee, Won;Kim, Ju-Young;Ock, Min-Su;Kim, So-Yoon;Lee, Sang-Il
    • Quality Improvement in Health Care
    • /
    • v.26 no.1
    • /
    • pp.23-34
    • /
    • 2020
  • Purpose: This qualitative study was conducted to examine the current status and problems concerning the collection of present on admission (POA) indicators and determine how to use these indicators for evaluating the quality of care and degree of patient safety. Methods: A total of 11 health information managers were divided into two groups according to the size of their hospitals. Two focus group discussions (FGDs) were conducted, one for each group, which followed a pre-developed semi-structured guideline. The verbatim transcriptions of the FGDs were analyzed. Results: The majority of participants were concerned about entering POA flags honestly because they did not know how future POA indicators would be used. In particular, for some participants, POA N was a burden that could imply a signal of mismanagement within the medical institution. In addition, the lack of awareness and indifference of physicians regarding POA indicators were some of the difficulties for POA flag entry. Although medical institutions are making efforts to improve the accuracy of POA flagging, many participants mentioned the need to develop real case-oriented POA entry guidelines to improve the accuracy of POA flagging. Conclusion: To increase the validity of POA indicators, it is necessary to increase the level of awareness of POA indicators in physicians and other medical professionals. Furthermore, efforts related to POA indicators by individual medical institutions need to be reflected in the process evaluation.

Evaluation of Silicon Carbide (SiC) for Deep Borehole Disposal Canister (심부시추공 처분용기 재료로서 SiC 세라믹의 적합성 평가)

  • LEE, Minsoo;LEE, Jongyoul;CHOI, Heuijoo;YOO, MalGoBalGaeBitNaLa;JI, Sunghoon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.2
    • /
    • pp.233-242
    • /
    • 2018
  • To overcome the low mechanical strength and corrosion behavior of a carbon steel canister at high temperature condition of a deep borehole, SiC ceramics were studied as an alternative material for the disposal canister. In this paper, a design concept for a SiC canister, along with an outer stainless steel container, was proposed, and its manufacturing feasibility was tested by fabricating several 1/3 scale canisters. The proposed canister can contain one PWR assembly. The outer container was also prepared for the string formation of SiC canisters. Thermal conductivity was measured for the SiC canister. The canister had a good thermal conductivity of above $70W{\cdot}m^{-1}{\cdot}K^{-1}$ at $100^{\circ}C$. The structural stability was checked under KURT environment, and it was found that the SiC ceramics did not exhibit any change for the 3 year corrosion test at $70^{\circ}C$. Therefore, it was concluded that SiC ceramics could be a good alternative to carbon steel in application to deep borehole disposal canisters.

Actual condition on accuracy control of mammography equipment in Kyeongsangbuk-do (경상북도 유방촬영장비의 정도관리에 대한 실태조사)

  • Kim, Sang-Jin;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.29-37
    • /
    • 2006
  • The breast cancer has the highest occurrence rate among the female cancers, and as the living style changes, the occurrence is increasing gradually. For the breast cancer test among women, who comprises up to 50% of the total population, the mammography is mainly used as the screening test, and the accuracy control is the most important aspect of the testing. Therefore this research divided the northern part of Kyeongsangbuk-do into 4 regions and investigated the accordance ratio of examination field and light examination field, the total focus using the optical density and compression rate, and the overall maintenance of mammography within the regions. The equipments of 11 hospitals were investigated, and the 7 hospitals passed the standard level of the accordance ratio of examination field. 6 hospitals passed the standard optical density, and 7 hospitals had the passing performance in the compression rate. Fibers, group of specks, and masses within the Mammographic Accreditation Phantom scored 10, being within the standard range. However, only 3 hospitals were equipped with private development processor and illumination. The result reflects the fact that the image quality of breast is not correctly being maintained. Moreover, only 27.27% satisfied all the three categories of compression fitting, accordance ratio of examination field, and phantom image evaluation at the same time. The accuracy control must be maintained more precisely for the accurate diagnosis of breast cancer.

  • PDF

A New Spray Chrysanthemum Cultivar, 'Blue Hope' with Anemone Type and White Petals for Cut Flower (백색 아네모네형 절화용 스프레이국화 '블루호프' 육성)

  • Hwang, Ju-Chean;Chin, Young-Don;Chung, Yong-Mo;Kim, Su-Kyeong;Ro, Chi-Woong;Jeong, Byoung Ryong
    • Horticultural Science & Technology
    • /
    • v.31 no.1
    • /
    • pp.123-127
    • /
    • 2013
  • A new spray chrysanthemum (Dendranthema grandiflorum) 'Blue Hope' was bred by the Flower Research Institute, Gyeongsangnam-do Agricultural Research & Extension Services in 2009. The cultivar 'Blue Hope' was initially derived from the cross in 2005 between 'Ford', a spray chrysanthemum cultivar, with white anemone type, and 'Chopin', a spray chrysanthemum cultivar with white anemone type. The cultivar has anemone type with white petals. After the evaluation of the characteristics under shade culture in summer and retarding culture in spring and consecutive selection from 2007 to 2009, 'Blue Hope' was selected finality. The natural flowering time of 'Blue Hope' was October 24th, and year-round flowering is possible by shading or lighting treatment. The growth of plant was very vigorous and response time 6.5 weeks. The diameter of flower was 4.9 cm. Number of flowers per stem was 19.1 in autumn. Days to flowering under the short day treatment was about 45 in spring and its vase life was 23.8 days in the autumn season. This cultivar was resistance white rust and consumer's preference of new spray is high level than the control.

Evaluation of the Level of Microbial Contamination in the Manufacturing and Processing Company of Red Pepper Powder (고춧가루 제조.가공업체의 시설 및 공정별 미생물학적 오염도 평가)

  • Woo, Hye-Im;Kim, Jong-Bae;Choi, Ji-Hee;Kim, Eun-Hye;Kim, Dong-Sul;Park, Kun-Sang;Kim, Eun-Jeong;Eun, Jong-Bang;Om, Ae-Son
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.4
    • /
    • pp.427-431
    • /
    • 2012
  • This study was conducted to monitor and evaluate microbial contamination during manufacturing process in 6 red pepper powder factories. Red pepper powder samples were taken from manufacturing facilitates, working area and workers' hands to determine sanitary indicator bacteria (SIB) such as aerobic bacteria and coliform group as well as pathogenic indicator bacteria (PIB) such as Staphylococcus aureus, E.coli, Salmonella spp., Listeria monocytogenes, and Bacillus cereus. The results indicated that SIB in primary materials was detected as low as 3 log units and E.coil and Staphylococcus aureus of PIB were detected. After grinding process, aerobic bacteria, fungi, and coliform group increased 52% and 108%, respectively. In final products, PIB was not detected except for one found Staphylococcus aureus by which workers' hands were contaminated. Moreover, UV detectors in all the manufacturers were not able to reduce bacteria. Thus, this data suggest that a stringent safety management be needed to prevent cross contamination, and also reconsider effectiveness of facility.