• Title/Summary/Keyword: target utilization

Search Result 421, Processing Time 0.023 seconds

Study on target erosion in rocking magnet sputtering system

  • Lee, Do-Sun;Kwon, Ui-Hui;Lee, Won-Jong
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.245-251
    • /
    • 2005
  • A high performance dual rocking magnet sputtering gun has been developed. The rocking magnet sputtering gun introduces full-face erosion by rapidly rocking the magnet in the region where the high plasma density is maintained. The newly developed dual rocking magnet sputtering gun whose target utilization was 77 percent achieved high performance in quality in the view of target utilization and target life-time comparing to the existing magnetron sputtering gun. The PIC-MCC target erosion simulation has been performed simultaneously. Comparing experimental target erosion profiles with simulated target erosion profiles, the simulation could estimate the tendency of the target erosion profiles but could not estimate an exact target erosion profile. If the simulation were improved more precisely, the cost reduction for the development of the multiple rocking magnet sputtering gun would be expected.

RAM Target Value Setting for a Defense System Using Subsystems' Mission Profiles and Utilization Rates: Case Study of System A (부체계의 임무 프로파일 및 운용 비율을 고려한 무기체계의 RAM 목표값 설정: A체계 사례 연구)

  • In-Hwa Bae;Sang-Boo Kim;Jea-Woo You;Woo-Jae Park;Eun-Ji You;Min-Young Lee;Ki-Hoon Song
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.5
    • /
    • pp.885-894
    • /
    • 2023
  • Setting RAM target value for a defense system plays a crucial role in the development and design phases and the production phase as well. It is apparent that the achieved RAM target value can help maximizing the combat capability of a defense system and improving its performance throughout the system's life cycle from acquisition phase to disposal. Usually a defense system operates according to its OMS/MP (Operational Mode Summary / Mission Profile) and it consists of several subsystems which are supposed to be operated at each utilization rate under its operating conditions and the mission profiles assigned. In this study, a method of setting RAM target value is proposed for a defense system that are composed of several independent subsystems considering their utilization rates and the mission profiles assigned. And the case study of applying the proposed method of setting RAM target value to system A is dealt with.

A study on the overload control of the ATM switching system (ATM 교환기 과부하제어 연구)

  • 기장근;최진규;김영선
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.4
    • /
    • pp.952-960
    • /
    • 1996
  • In this paper, a new overload control scheme is proposed for a control system in ATM switching system. The proposed control scheme includes a counter that conunts the number of accepted calls and is decreased at cach D time interval. In overload condition of call processor, the control scheme detects over load condition when the counter value reaches a certain threshold value. Under overload condition, processor utilization is measured and the value of the D is updataed according to the difference between measured processor utilization and target utilization. A new call is accepted accepted only if the value of the counter is less than the threshold value. In overflow condition of cell traffic, accept probability of new call is reduced exponetially according to the elapsed time. The results of simulation show that the proposed overload contorl scheme maintains the target utilization very well under the various processor overload conditions and reduces the cell loss probability under the cell overflow conditions.

  • PDF

Video Quality Control Scheme for Efficient Bandwidth Utilization of HTTP Adaptive Streaming in a Multiple-Clients Environment (다중 클라이언트 환경에서 HTTP 적응적 스트리밍의 효율적인 대역폭 활용을 위한 비디오 품질 조절 기법)

  • Kim, Minsu;Kim, Heekwang;Chung, Kwangsue
    • Journal of KIISE
    • /
    • v.45 no.1
    • /
    • pp.86-93
    • /
    • 2018
  • When multiple clients share bandwidth and receive a streaming service, HTTP Adaptive Streaming has a problem in that the bandwidth is measured inaccurately due to the ON-OFF pattern of the segment request. To solve the problem caused by the ON-OFF pattern, the proposed PANDA (Probe AND Adapt) determines the quality of the segment to be requested while increasing the target bandwidth. However, since the target bandwidth is increased by a fixed amount, there is a problem in low bandwidth utilization and a slow response to changes in bandwidth. In this paper, we propose a video quality control scheme that improves the low bandwidth utilization and slow responsiveness of PANDA. The proposed scheme adjusts the amount of increase in the target bandwidth according to the bandwidth utilization after judging the bandwidth utilization by comparing the segment download time and the request interval. Experimental results show that the proposed scheme can fully utilize the bandwidth and can quickly respond to changes in bandwidth.

A Study on the Performance and Utilization of Results of Self-monitoring of Blood Glucose in Type Ⅱ Diabetes (일 병원 제2형 당뇨병환자의 자가혈당검사 수행 및 활용 실태)

  • Ha, Jung-Mi;Kim, Dong-Hee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.16 no.2
    • /
    • pp.330-338
    • /
    • 2010
  • Purpose: This study was conducted to investigate performance of self-monitoring of blood glucose and the utilization of results for people with type II diabetes. Method: Data was collected from 177 patients with type II diabetes using a questionnaire from August to September, 2009. Result: Most participants performed self-monitoring of blood glucose in the correct way while some misused the lancet or test strips. In the utilization of results for self-monitoring blood glucose data, 62% of participants always recorded the data, 46% always understood the cause for hyperglycemia or hypoglycemia, 25% changed their diet, 23% regulated their exercise-amount, and 11% of participants adjusted the drug dosage. There were significant differences in the performance of self-monitoring of blood glucose and the utilization of results according to the characteristics in the self-monitoring subjects such as awareness of HbA1c, target fasting glucose level, target fasting glucose level 2 hours after meal etc. Conclusion: Systemic self-monitoring of blood glucose education which includes the utilization of self-monitoring of blood glucose needs to be developed for type II diabetic patients.

Lipid A as a Drug Target and Therapeutic Molecule

  • Joo, Sang Hoon
    • Biomolecules & Therapeutics
    • /
    • v.23 no.6
    • /
    • pp.510-516
    • /
    • 2015
  • In this review, lipid A, from its discovery to recent findings, is presented as a drug target and therapeutic molecule. First, the biosynthetic pathway for lipid A, the Raetz pathway, serves as a good drug target for antibiotic development. Several assay methods used to screen for inhibitors of lipid A synthesis will be presented, and some of the promising lead compounds will be described. Second, utilization of lipid A biosynthetic pathways by various bacterial species can generate modified lipid A molecules with therapeutic value.

Emergency Health Care Utilization according to Income class (소득계층에 따른 응급의료이용)

  • Choi, Ryoung;Hwang, Byung-Deog
    • Korea Journal of Hospital Management
    • /
    • v.18 no.4
    • /
    • pp.78-96
    • /
    • 2013
  • The purpose of this study is to analyze the emergency health care utilization using status according to income class. The target was the 2011 data out Korea Health Panel's raw data. 2011 data composed of total 17,035 people from total 5,741 households. This study set total 1,101 adults over full-20-years old having used an emergency health care utilization as its analysis target. In order to find out the number of emergency health care utilization use according to income class and the influential factors on emergency health care utilization cost, this study conducted the multiple regression analysis. And in order to more accurately analyze the emergency health care utilization use status depending on the income class and the features of emergency health care utilization use status, this study developed Models. As the result, this study found following findings. First, as the income class was lower, the gender was male, the age was lower, and the user has spouse, the user was not a business owner or a paid worker, the user is a house owner, the emergency medical facility type was a clinic, the means of transportation was others rather than 119 ambulance, the reason visiting emergency medical facility was belonged to others rather than accidents or poisoning, then the number of emergency was increased. Second, as the user was in higher income class, received the health insurance benefits, the using medical facility was general hospital, used 119 ambulance more often, stay days in emergency was shorter, then health care utilization cost was increased. In this study investigating the data out of Korea Health Panel, it was found that while the number of emergency health care utilization use was increased in the lower income class, but the emergency health care utilization cost was increased for higher income class. It is considered that this finding was caused from the facts that lower income class was more often exposed to dangers for physical health, so the number of emergency health care utilization use was increased, but their health care utilization cost was decreased because of their economic burdens against various examinations and their difficulties to pay such costs, comparing to that of higher income class. Therefore, in order to solve unequal problem of emergency health care utilization use between lower and higher income classs, it is required to set suitable solutions like the disease prevention effort by facilitating national health check-up programs, the enhancement of public health services in quantity and quality, the emergency health care utilization securing policy at using medical facilities, the promotional, educational activities about emergency health care utilization delivery system, the enhanced accessibility of emergency health care utilizations and emergency medical facilities.

  • PDF

Study on Multiple Ground Target Tracking Algorithm Using Geographic Information (지형 정보를 사용한 다중 지상 표적 추적 알고리즘의 연구)

  • Kim, In-Taek;Lee, Eung-Gi
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.2
    • /
    • pp.173-180
    • /
    • 2000
  • During the last decade many researches have been working on multiple target tracking problem in the area of radar application, Various approaches have been proposed to solve the tracking problem and the concept of sensor fusion was established as an effort. In this paper utilization of geographic information for ground target tracking is investigated and performance comparison with the results of applying sensor fusion is described. Geographic information is used in three aspects: association masking target measurement and re-striction of removing true target. Simulation results indicate that using two sensors shows better performance with respect to tracking but a single with geographic information is a winner in reducing the number of false tracks.

  • PDF

Design of Linear Recursive Target State Estimator for Collision Avoidance System (차량 충돌 방지 시스템을 위한 선형 순환 표적 추정기 설계)

  • Han, Seul-Ki;Ra, Won-Sang;Whang, Ick-Ho;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1740-1741
    • /
    • 2011
  • This paper proposes a new linear recursive target state estimator for automotive collision warning system. The target motion is modeled in Cartesian coordinate system while the radar measurements such as range, line-of-sight angle and range rate are obtained in polar coordinate system. To solve the problem by nonlinear relation between these two coordinate system, a practical linear filter design scheme employing the predicted line-of-sight Cartesian coordinate system (PLCCS) is proposed. Especially, PLCCS can effectively incorporate range rate measurements into target tracking system. It is known that the utilization of range rate measurements enables the improvement of target tracking performance. Moreover, PLCCS based target tracking system is implemented by linear recursive filter structure and hence is more suitable scheme for the development of reliable collision warning system. The performance of the proposed method is demonstrated by computer simulations.

  • PDF

An Efficient Explicit Rate Feedback Switch Algorithm for the ABR Flow Control (ABR 흐름 제어를 위한 효율적인 명시율 피드백 스위치 알고리즘)

  • 김병철;김동호;조유제
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.9A
    • /
    • pp.1359-1371
    • /
    • 1999
  • In this paper, we propose an efficient explicit rate (ER) feedback switch algorithm for available bit rate (ABR) flow control. In order to improve the disadvantages of existing ER feedback switch algorithms with congestion avoidance, the proposed scheme adjusts the target utilization dynamically according to the queue length and its growth rate. also, we investigate the performance of the proposed switch algorithm and compare it with ERICA and NIST switches using simulation. Simulation results show that the proposed switch algorithm can control the cell emission rate of a source rapidly according to variations of available link bandwidth by using dynamic adaptation of target utilization. It also exhibits a better performance than the existing ER feedback switches in terms of queue length and link utilization.

  • PDF