• Title/Summary/Keyword: target therapy

Search Result 1,160, Processing Time 0.033 seconds

An Investigation of Glyceollin I's Inhibitory Effect on The Mammalian Adenylyl (글리세올린 I의 아데니닐 고리화 효소 활성 억제 효능과 결합 부위 비교 분석)

  • Kim, Dong-Chan;Kim, Nam Doo;Kim, Sung In;Jang, Chul-Soo;Kweon, Chang Oh;Kim, Byung Weon;Ryu, Jae-Ki;Kim, Hyun-Kyung;Lee, Suk Jun;Lee, Seungho;Kim, Dongjin
    • Journal of Life Science
    • /
    • v.23 no.5
    • /
    • pp.609-615
    • /
    • 2013
  • Glyceollin I has gained attention as a useful therapy for various dermatological diseases. However, the binding property of glyceollin I to the mammalian adenylyl cyclase (hereafter mAC), a critical target enzyme for the down-regulation of skin melanogenesis, has not been fully explored. To clarify the action mechanism between glyceollin I and mAC, we first investigated the molecular docking property of glyceollin I to mAC and compared with that of SQ22,536, a well-known mAC inhibitor, to mAC. Glyceollin I showed superiority by forming three hydrogen bonds with Asp 1018, Trp 1020, and Asn 1025, which exist in the catalytic site of mAC. However, SQ22,536 formed only two hydrogen bonds with Asp 1018 and Asn 1025. Secondly, we confirmed that glyceollin I effectively inhibits the formation of forskolin-induced cAMP and the phosphorylation of PKA from a cell-based assay. Long term treatment with glyceollin I had little effect on the cell viability. The findings of the present study also suggest that glyceollin I may be extended to be used as an effective inhibitor of hyperpigmentation.

Preliminary Results of Stereotactic Radiosurgery Using Stereotactic Body Frame (정위 체부 고정틀을 이용한 체부 방사선수술의 예비적 결과)

  • Ahn Seung Do;Yi Byong Yong;Choi Eun Kyung;Kim Jong Hoo;Nho Young Ju;Shin Kyung Hwan;Kim Kyoung Ju;Chung Won Kyun;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.251-256
    • /
    • 2000
  • Purpose : To evaluate efficacy and complication of stereotactic radiosurgery using stereotactic body frame. Methods and Materials :From December 1997 to June 1999, 11 patients with primary and metastatic tumors were treated with stereotactic radiosurgery using stereotactic body frame(Precision TherapyTu). Three patients were treated with primary hepatoma and seven with metastatic tumor from liver, lung, breast, trachea and one with arteriovenous malformation on neck. We used vacuum pillow for immobilization and made skin marker on sternum and tibia area with chest marker and leg marker. Diaphragm control was used for reducing movement by respiration. CT-simulation and treatment planning were peformed. Set-up error was checked by CT-Simulator before each treatment. Dose were calculated on the 80$\~$90$\%$ isodose of isocenter dose and given consecutive 3 fractions for total dose of 30 Gy (10 Gy/fraction). Results :Median follow-up was 12 months. One patient (9$\%$) showed complete response and four Patients (36$\%$) showed partial response and others showed stable disease. Planning target volumes (PTV) ranged from 3 to 111 cc (mean 18.4 n). Set-up error was within 5 mm in all directions (X, Y, Z axis). There was no complication in all patients. Conclusion :In Primary and metastatic tumors, stereotactic body frame is very safe, accurate and effective treatment modality.

  • PDF

Effect of an Acrylic Plate and SSD on Dose Profile and Depth Dose Distribution of 9 MeV Electron Beams (에너지 저하체로서 아크릴과 SSD 가 9MeV 전자선의 측방 및 깊이선량분포에 미치는 효과)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.65-71
    • /
    • 1998
  • The aims are to evaluate the effects of an 1.0 cm acrylic plate and SSD on the dose profile and depth dose distribution of 9 MeV electron beam and to analyse adequacy for using an acrylic plate to reduce energy of electron beams. An acrylic plate of 1.0 cm thickness was used to reduce energy of 9 MeV electron beam to 7 MeV. The plate was put on an electron applicator at 65.4 cm distance from x-ray target. The size of the applicator was 10${\times}$l0cm at 100 cm SSD. For 100cm, l05cm and 110cm SSD, depth dose on beam axis and dose profiles at d$\_$max/ on two principal axes were measured using a 3D water phantom. From depth dose distributions, d$\_$max/, d$\_$85/, d$\_$50/ and R$\_$p/, surface dose, and mean energy and peak energy at surface were compared. From dose profiles flatness, penumbra width and actual field size were compared. For comparison, 9 MeV electron beams were measured. Surface dose of 7 MeV electron beams was changed from 85.5% to 82.2% increasing SSD from 100 cm to 110 cm, and except for dose buildup region, depth dose distributions were independent of SSD. Flatness of 7 MeV ranged from 4.7% to 10.4% increasing SSD, comparing 1.4% to 3.5% for 9 MeV. Penumbra width of 7 MeV ranged from 1.52 cm to 3.03 cm, comparing 1.14 cm to 1.63 cm for 9 MeV. Actual field size increased from 10.75 cm to 12.85 cm with SSD, comparing 10.32 cm to 11.46 cm for 9 MeV. Virtual SSD's of 7 and 9 MeV were respectively 49.8 cm and 88.5cm. In using energy reducer in electron therapy, depth dose distribution were independent of SSD except for buildup region as well as open field. In case of using energy reducer, increasing SSD made flatness to deteriorate more severely, penumbra width more wide, field size to increase more rapidly and virtual SSD more short comparing with original electron beam. In conclusion, it is desirable to use no energy reducer for electron beam, especially for long SSD.

  • PDF

Evaluation of Setup Uncertainty on the CTV Dose and Setup Margin Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 셋업오차가 임상표적체적에 전달되는 선량과 셋업마진에 대하여 미치는 영향 평가)

  • Cho, Il-Sung;Kwark, Jung-Won;Cho, Byung-Chul;Kim, Jong-Hoon;Ahn, Seung-Do;Park, Sung-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.81-90
    • /
    • 2012
  • The effect of setup uncertainties on CTV dose and the correlation between setup uncertainties and setup margin were evaluated by Monte Carlo based numerical simulation. Patient specific information of IMRT treatment plan for rectal cancer designed on the VARIAN Eclipse planning system was utilized for the Monte Carlo simulation program including the planned dose distribution and tumor volume information of a rectal cancer patient. The simulation program was developed for the purpose of the study on Linux environment using open source packages, GNU C++ and ROOT data analysis framework. All misalignments of patient setup were assumed to follow the central limit theorem. Thus systematic and random errors were generated according to the gaussian statistics with a given standard deviation as simulation input parameter. After the setup error simulations, the change of dose in CTV volume was analyzed with the simulation result. In order to verify the conventional margin recipe, the correlation between setup error and setup margin was compared with the margin formula developed on three dimensional conformal radiation therapy. The simulation was performed total 2,000 times for each simulation input of systematic and random errors independently. The size of standard deviation for generating patient setup errors was changed from 1 mm to 10 mm with 1 mm step. In case for the systematic error the minimum dose on CTV $D_{min}^{stat{\cdot}}$ was decreased from 100.4 to 72.50% and the mean dose $\bar{D}_{syst{\cdot}}$ was decreased from 100.45% to 97.88%. However the standard deviation of dose distribution in CTV volume was increased from 0.02% to 3.33%. The effect of random error gave the same result of a reduction of mean and minimum dose to CTV volume. It was found that the minimum dose on CTV volume $D_{min}^{rand{\cdot}}$ was reduced from 100.45% to 94.80% and the mean dose to CTV $\bar{D}_{rand{\cdot}}$ was decreased from 100.46% to 97.87%. Like systematic error, the standard deviation of CTV dose ${\Delta}D_{rand}$ was increased from 0.01% to 0.63%. After calculating a size of margin for each systematic and random error the "population ratio" was introduced and applied to verify margin recipe. It was found that the conventional margin formula satisfy margin object on IMRT treatment for rectal cancer. It is considered that the developed Monte-carlo based simulation program might be useful to study for patient setup error and dose coverage in CTV volume due to variations of margin size and setup error.

Comparison of Anisotropic Analytic Algorithm Plan and Acuros XB Plan for Lung Stereotactic Ablative Radiotherapy Using Flattening Filter-Free Beams (비편평화여과기 빔을 이용한 폐 정위절제방사선치료를 위한 AAA와 Acuros XB 계산 알고리즘의 치료계획 비교)

  • Chung, Jin-Beom;Eom, Keun-Yong;Kim, In-Ah;Kim, Jae-Sung;Lee, Jeong-Woo;Hong, Semie;Kim, Yon-Lae;Park, Byung-Moon;Kang, Sang-Won;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.210-217
    • /
    • 2014
  • This study investigated the dosimetric effects of different dose calculation algorithm for lung stereotactic ablative radiotherapy (SABR) using flattening filter-free (FFF) beams. A total of 10 patients with lung cancer who were treated with SABR were evaluated. All treatment plans were created using an Acuros XB (AXB) of an Eclipse treatment planning system. An additional plans for comparison of different alagorithm recalcuated with anisotropic analytic algorithm (AAA) algorithm. To address both algorithms, the cumulative dose-volume histogram (DVH) was analyzed for the planning target volume (PTV) and organs at risk (OARs). Technical parameters, such as the computation times and total monitor units (MUs), were also evaluated. A comparison analysis of DVHs from these plans revealed the PTV for AXB estimated a higher maximum dose (5.2%) and lower minimum dose (4.2%) than that of the AAA. The highest dose difference observed 7.06% for the PTV $V_{105%}$. The maximum dose to the lung was also slightly larger in the AXB plans. The percentate volumes of the ipsilateral lung ($V_5$, $V_{10}$, $V_{20}$) receiving 5, 10, and 20 Gy were also larger in AXB plans than for AAA plans. However, these parameters were comparable between both AAA and AXB plans for the contralateral lung. The differences of the maximum dose for the spinal cord and heart were also small. The computation time of AXB plans was 13.7% shorter than that of AAA plans. The average MUs were 3.47% larger for AXB plans than for AAA plans. The results of this study suggest that AXB algorithm can provide advantages such as accurate dose calculations and reduced computation time in lung SABR plan using FFF beams, especially for volumetric modulated arc therapy technique.

A Study on Experimental Construction of Community Garden - A Case Study on Rooftop of SAHA Disabled Welfare House - (커뮤니티 가든 조성을 위한 실험 연구 - 사하 장애인복지관 옥상을 대상으로 -)

  • Kim, Seung-Hwan;Yoon, Sung-Yung;Cha, Min-Jun;Yoo, yeon-seo;Cho, Ji-Young;Kim, Yoon-Sun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.2
    • /
    • pp.24-37
    • /
    • 2012
  • In this study, Community Garden of various national and international practices trends to an advanced research, the concept of community garden participated with a group operation out of initiative to produce safety food while securing space for the community, ensuring the area that has gone through a new form of active secure urban green space plan, urban renewal movement was defined as the mean. Furthermore, for the purpose of improving the poor welfare environment by attempting to experimentally make a community garden of a disabled welfare house rooftop and how to target its planning and construction process, partnership involvement, business processes have been investigated, such as cost sharing. The whole process including a budget for development of this case was conducted by the Busan Green Trust. Standard Chartered (SC) First Bank's 50% fund share by community chest, participation of volunteers, support of Busan City and Saba-gu, outside of that, sharing parts or trial to participate by diverse partnership of enterprise, public corporation and laboratory, these are the key in developing community garden's model. Established community garden places resulted food production to users of welfare center for the disabled, participating urban agricultural experience program, horticultural therapy, complex community chapter and cultural center. Furthermore, we could find the meaning of rooftop community garden in the point that it is a low cost garden by applying movable and unmovable planters. This study is profitable for improving urban environment, ensuring community chapter and urban green areas, regenerating a city to develop experimental community garden model by using a welfare house rooftop.

Long-term Results of Gamma Knife Radiosurgery for Craniopharyngioma (두개인두종의 감마나이프 치료 후 장기 추적 결과)

  • Kim, Yun Sok;Lee, Do Heui;Ra, Dong Suk;Chun, Young Il;Ahn, Jae Sung;Jeon, Sang Ryong;Kim, Jeong Hoon;Roh, Sung Woo;Ra, Young Shin;Kim, Chang Jin;Kwon, Yang;Rhim, Seung Chul;Lee, Jung Kyo;Kwun, Byung Duk
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.289-293
    • /
    • 2001
  • Objectives : The optimal treatment of craniopharyngioma is controversial. Despite recent advances in microsurgical management, complete surgical removal of craniopharyngioma remains very difficult. Radiation added to surgery is effective, but radiation therapy resulted in untoward side effect in young patient. Gamma knife radiosurgery offers the theoretical advantage of a reduced radiation dose to surrounding structures during the treatment of residual or recurrent craniopharyngioma compared with fractionated radiotheraphy. We described retrospective analysis of tumor size and clinical symptoms of patients after gamma knife radiosurgery in residual or recurrent craniopharyngioma were performed. Material and Methods : From September 1990 to January 2000, 18 patients of craniopharyngioma were treated by gamma knife radiosurgery. All patient had undergone surgery, but residual or recurrent tumor was found and all of them treated postoperative gamma knife radiosurgery. The mean age was 19(from 6 to 66) and male to female ratio was 10 to 8 and 8 patients were below 15 years old. In young age group(below age 15), the average volume of the tumor was $2904.8mm^3$ and mean maximal gamma knife dose was 34.9Gy. In old age group(older than 15), the average volume of the tumor was $2590.4mm^3$ and mean maximal gamma knife dose was 45.2Gy. The size of the tumor was average $2730.1mm^3$($88-12000mm^3$), mean average radiation dose was 40.7Gy and the mean prescription dose was 17.6 Gy(4-35Gy) delivered to a median prescription 50.7% isodose. Results : The follow up was from 1 year to 9 years(mean 59.1 months) after gamma knife radiosurgery. The tumor was controlled in 13(72.2%) patients. The tumor decreased in 9 patients and not changed in 4 patients. The tumor size increased in 4(22.2%) patients during follow up period. In two cases the tumor size increased because of its cystic portion was increased, but their solid portion of the tumor was not changed. In another two patients, the solid portion of the tumor was increased. So, one patient underwent reoperation and the other patient underwent operation and repeated gamma knife radiosurgery. The tumor recurred in one case(5.6%) that is a outside of irradiated site. The presenting symptoms were improved in 4 patients(improved visual acuity in 1, controlled increased intracranial presure sign in 3 patients). In one case, visual acuity decreased after gamma knife radiosurgery. The endocrine symptoms were not influenced by gamma knife radiosurgery. Conclusion : Craniopharyngioma can be treated successfully by gamma knife radiosurgery. Causes of the tumor regrowth are inadequate dose planning because of postoperatively poor margination of the tumor, close approximation of optic nerve and residual tumors outside the target lesion. Recurrence can develop 4 years after gamma knife radiosurgery. Volume is important, but the accurate targeting is more important to prevent tumor recurrence. If the tumor definition is not clear during planning gamma knife surgery, long-term image follow up is required.

  • PDF

Comparison of CT based-CTV plan and CT based-ICRU38 plan in Brachytherapy Planning of Uterine Cervix Cancer (자궁경부암 강내조사 시 CT를 이용한 CTV에 근거한 치료계획과 ICRU 38에 근거한 치료계획의 비교)

  • Cho, Jung-Ken;Han, Tae-Jong
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.105-110
    • /
    • 2007
  • Purpose : In spite of recent remarkable improvement of diagnostic imaging modalities such as CT, MRI, and PET and radiation therapy planing systems, ICR plan of uterine cervix cancer, based on recommendation of ICRU38(2D film-based) such as Point A, is still used widely. A 3-dimensional ICR plan based on CT image provides dose-volume histogram(DVH) information of the tumor and normal tissue. In this study, we compared tumor-dose, rectal-dose and bladder-dose through an analysis of DVH between CTV plan and ICRU38 plan based on CT image. Method and Material : We analyzed 11 patients with a cervix cancer who received the ICR of Ir-192 HDR. After 40Gy of external beam radiation therapy, ICR plan was established using PLATO(Nucletron) v.14.2 planing system. CT scan was done to all the patients using CT-simulator(Ultra Z, Philips). We contoured CTV, rectum and bladder on the CT image and established CTV plan which delivers the 100% dose to CTV and ICRU plan which delivers the 100% dose to the point A. Result : The volume$(average{\pm}SD)$ of CTV, rectum and bladder in all of 11 patients is $21.8{\pm}6.6cm^3,\;60.9{\pm}25.0cm^3,\;111.6{\pm}40.1cm^3$ respectively. The volume covered by 100% isodose curve is $126.7{\pm}18.9cm^3$ in ICRU plan and $98.2{\pm}74.5cm^3$ in CTV plan(p=0.0001), respectively. In (On) ICRU planning, $22.0cm^3$ of CTV volume was not covered by 100% isodose curve in one patient whose residual tumor size is greater than 4cm, while more than 100% dose was irradiated unnecessarily to the normal organ of $62.2{\pm}4.8cm^3$ other than the tumor in the remaining 10 patients with a residual tumor less than 4cm in size. Bladder dose recommended by ICRU 38 was $90.1{\pm}21.3%$ and $68.7{\pm}26.6%$ in ICRU plan and in CTV plan respectively(p=0.001) while rectal dose recommended by ICRU 38 was $86.4{\pm}18.3%$ and $76.9{\pm}15.6%$ in ICRU plan and in CTV plan, respectively(p=0.08). Bladder and rectum maximum dose was $137.2{\pm}50.1%,\;101.1{\pm}41.8%$ in ICRU plan and $107.6{\pm}47.9%,\;86.9{\pm}30.8%$ in CTV plan, respectively. Therefore, the radiation dose to normal organ was lower in CTV plan than in ICRU plan. But the normal tissue dose was remarkably higher than a recommended dose in CTV plan in one patient whose residual tumor size was greater than 4cm. The volume of rectum receiving more than 80% isodose (V80rec) was $1.8{\pm}2.4cm^3$ in ICRU plan and $0.7{\pm}1.0cm^3$ in CTV plan(p=0.02). The volume of bladder receiving more than 80% isodose(V80bla) was $12.2{\pm}8.9cm^3$ in ICRU plan and $3.5{\pm}4.1cm^3$ in CTV plan(p=0.005). According to these parameters, CTV plan could also save more normal tissue compared to ICRU38 plan. Conclusion : An unnecessary excessive radiation dose is irradiated to normal tissues within 100% isodose area in the traditional ICRU plan in case of a small size of cervix cancer, but if we use CTV plan based on CT image, the normal tissue dose could be reduced remarkably without a compromise of tumor dose. However, in a large tumor case, we need more research on an effective 3D-planing to reduce the normal tissue dose.

Rectal Bleeding and Its Management after Irradiation for Cervix Cancer (자궁경부암 환자에서 방사선치료 후에 발생한 직장출혈과 치료)

  • Chun Mison;Kang Seunghee;Kil Hoon-Jong;Oh Young-Taek;Sohn Jeong-Hye;Jung Hye-Young;Ryu Hee Suk;Lee Kwang-Jae
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.343-352
    • /
    • 2002
  • Purpose : Radiotherapy is the main treatment modality for uterine cervix cancer. Since the rectum is in the radiation target volume, rectal bleeding is a common late side effect. This study evaluates the risk factors of radiation induced rectal bleeding and discusses its optimal management. Materials and Methods : total of 213 patients who completed external beam radiation therapy (EBRT) and intracavitary radiation (ICR) between September 1994 and December 1999 were included in this study. No patient had undergone concurrent chemo-radiotherapy. Ninety patients received radiotherapy according to a modified hyperfractionated schedule. A midline block was placed at a pelvic dose of between 30.6 Gy to 39.6 Gy. The total parametrial dose from the EBRT was 51 to 59 Gy depending on the extent of their disease. The Point A dose from the HDR brachytherapy was 28 Gy to 30 Gy $(4\;Gy\times7,\;or\;5\;Gy\times6)$. The rectal point dose was calculated either by the ICRU 38 guideline, or by anterior rectal wall point seen on radiographs, with barium contrast. Rectal bleeding was scored by the LENT/SOMA criteria. For the management of rectal bleeding, we opted for observation, sucralfate enema or coagulation based on the frequency or amount of bleeding. The median follow-up period was 39 months $(12\~86\;months)$. Results : The incidence of rectal bleeding was $12.7\%$ (27/213); graded as 1 in 9 patients, grade 2 in 16 and grade 3 in 2. The overall moderate and severe rectal complication rate was $8.5\%$. Most complications $(92.6\%)$ developed within 2 years following completion of radiotherapy (median 16 months). No patient progressed to rectal fistula or obstruction during the follow-up period. In the univariate analysis, three factors correlated with a high incidence of bleeding an icruCRBED greater than 100 Gy $(19.7\%\;vs.\;4.2\%)$, an EBRT dose to the parametrium over 55 Gy $(22.1\%\;vs.\;5.1\%)$ and higher stages of III and IV $(31.8\%\;vs.\;10.5\%)$. In the multivariate analysis, the icruCRBED was the only significant factor (p>0.0432). The total parametrial dose from the EBRT had borderline significance (p=0.0546). Grade 1 bleeding was controlled without further management (3 patients), or with sucralfate enema 1 to 2 months after treatment. For grade 2 bleeding, sucralfate enema for 1 to 2 months reduced the frequency or amount of bleeding but for residual bleeding, additional coagulation was peformed, where immediate cessation of bleeding was achieved (symptom duration of 3 to 10 months). Grade 3 bleeding lasted for 1 year even with multiple transfusions and coagulations. Conclusion : Moderate and several rectal bleeding occurred in $8.5\%$ of patients, which is comparable with other reports. The most significant risk factor for rectal bleeding was the accumulated dose to the rectum (icruCRBED), which corrected with consideration to biological equivalence. Prompt management of rectal bleeding, with a combination of sucralfate enema and coagulation, reduced the duration of the symptom, and minimized the anxiety/discomfort of patients.

A Phase I/II Trial of $DCVac/IR^{(R)}$ Dendritic Cell Immunotherapy Combined with Irradiation in Cases of Refractory Colorectal Cancer with Multiple Liver Metastases (기존의 치료에 반응하지 않는 다발성 간전이 대장암 환자에서 방사선조사와 병합한 수지상세포 면역치료의 1, 2상 임상시험)

  • Choi, Young-Min;Lee, Hyung-Sik;Kwon, Hyuk-Chan;Han, Sang-Young;Choi, Jong-Cheol;Chung, Ju-Seop;Kim, Chang-Won;Kim, Dong-Won;Kang, Chi-Duk
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.104-112
    • /
    • 2008
  • Purpose: To assess the toxicity and tumor response induced by $DCVac/IR^{(R)}$ dendritic cell(DC) immunotherapy combined with irradiation for refractory colorectal cancer patients with multiple liver metastases. Materials and Methods: Between May 2004 and November 2006, applicants from a pool of refractory colorectal cancer patients with multiple liver metastases were enrolled. The patients were registered after having signed the informed consent form, which had been approved by the Institutional Review Board from the Dong-A University and Busan National University Hospital. DCs were obtained from peripheral blood of each patient, and then cultured in vitro. A total of $6{\times}10^6$ DCs were packed into a vial($DCVac/IR^{(R)}$, 0.5 ml) at the convenience of each patient's schedule. On the day before and on the day of each vaccination, each patient received a 4 Gy radiation dose to the target tumor. On the day of vaccination, the indicated dose of autologous DCs was injected into the irradiated tumor using ultrasound-guided needle injection procedures. A total of four vaccinations were scheduled at three 2-week intervals and one 4 week interval at the Dong-A University and Busan National University Hospital. If the tumor status was deemed to be stable or responding to therapy, an additional vaccination dose or two was approved at 4 week intervals beyond the fourth immunization. A tolerance test for DCs was conducted by injecting a range of doses($3{\times}10^6\;to\;12{\times}10^6$ DCs) after the 3rd injection. Moreover, the maximal tolerable dose was applied to additional patients. Treatment safety was evaluated in all patients who had at least one injection. Treatment feasibility was evaluated by the 10th week by assessing the response of patients having at least 4 injections. For systemic toxicities, the evaluation was performed using the National Cancer Institute Common Toxicity Criteria, whereas adverse effects were recorded using common WHO toxicity criteria. Results: Of the 24 registered patients, 22 received the DCs injections. Moreover, of the 14 patients that applied for the tolerance test, only 11 patients completed it because 3 patients withdrew their testing agreement. A grade 3 or more side effect, which was possibly related to the DC injection, did not occur in additional patients. The $12{\times}10^6$ DC injection was identified as the maximum tolerable dose, and was then injected in an additional 8 patients. Patients tolerated the injection fairly well, with no fatal side effects. In order to assess the feasibility of DC immunotherapy, the response was evaluated in other hepatic lesions outside of the targeted hepatic lesion. The response evaluation was performed in 15 of the 17 patients who received at least 4 injections. Stable and progressive disease was found in 4 and 11 patients, respectively. Conclusion: The DC-based immunotherapy and radiotherapy is theoretically synergistic for the local control and systemic control. The $DCVac/IR^{(R)}$ immunotherapy combined with irradiation was tolerable and safe in the evaluated cases of refractory colorectal cancer with multiple liver metastases. Future work should include well designed a phase II clinical trials.