• Title/Summary/Keyword: target rotation time

Search Result 70, Processing Time 0.023 seconds

Analysis of Movement Time and Trunk Motions According to Target Distances and Use of Sound and Affected Side During Upper Limb Reaching Task in Patients With Hemiplegia (편마비 환자의 팔 뻗기 과제 수행 시 목표거리와 건·환측 사용에 따른 운동시간과 체간의 움직임 분석)

  • Kim, Ki-Song;Yoo, Hwan-Suk;Jung, Doh-Heon;Jeon, Hye-Seon
    • Physical Therapy Korea
    • /
    • v.17 no.1
    • /
    • pp.36-42
    • /
    • 2010
  • The aim of this study was to investigate effects of reaching distance on movement time and trunk kinematics in hemiplegic patients. Eight hemiplegic patients participated in this study. The independent variables were side (sound side vs. affected side) and target distance (70%, 90%, 110%, and 130% of upper limb). The dependent variables were movement time measured by pressure switch and trunk kinematics measured by motion analysis device. Two-way analysis of variance with repeated measures was used with Bonferroni post-hoc test. (1) There were significant main effects in side and reaching distance for movement time (p=.01, p=.02). Post-hoc test revealed that there was a significant difference between 110% and 130% of reaching distance (p=.01). (2) There was a significant main effect in side and reaching distance for trunk flexion (p=.01, p=.00). Post-hoc test revealed that there were significant differences in all pair-wise reaching distance comparison. (3) There was a significant side by target distance interaction for trunk rotation (p=.04). There was a significant main effect in target distance (p=.00). Post-hoc test revealed that there were significant differences between 70% and 110%, 70% and 130%, 90% and 110%, 90% and 130% of target distance. It was known that trunk flexion is used more than trunk rotation during reaching task in hemiplegic patients from the findings of this study. It is also recommended that reaching training is performed with limiting trunk movement within 90% of target distance whereas reaching training is performed incorporating with trunk movement beyond 90% of target distance in patients with hemiplegia.

The Effect of Context on Mental Rotation (맥락 정보가 심적 회전에 미치는 영향)

  • Jung, Il-Yung;Lee, Chang-Hyun;Lee, Mi-Sun;Chong, Sang-Chul
    • Korean Journal of Cognitive Science
    • /
    • v.20 no.4
    • /
    • pp.555-571
    • /
    • 2009
  • This study investigated whether contexts could influence the speed of mental rotation. Experiment 1 investigated whether the angle of neighboring letters influenced the recognition of the target letter. Reaction time of target recognition increased linearly, as angular differences between the angle of the target letter and that of neighboring letters increased. Moreover, this trend was more pronounced when the target and neighboring letters made a word as compared to when they did not. Experiment 2 examined the effects of practice difficulty on mental rotation. Reaction time again increased linearly with the degree of angular rotation. However, there were no significant differences between the easy and the difficult conditions. These results suggest that contextual information is important in mental rotation.

  • PDF

Practicability Assessment of Spherical Mechanical Check Device(SMCD) (Mechanical Check용 Spherical device의 제작 및 특성 평가)

  • Lee, Byung-Koo;Yang, Dae-Sik;Kweon, Young-Ho;Ko, Shin-Gwan;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.153-159
    • /
    • 2007
  • Digital medical image commenced with an introduction of PACS has become more popular today in the radiation diagnosis and radiation treatment and made great progress, in particular, for medical testing field, whereas it has made slow progress for radiation treatment field. In order to accommodate the current trend of digital from analog, a spherical mechanical check device(SMCD) that is the form of spherical differing from the existing form of flat or cube has been designed and tested its practicability to replace the part in mechanical check with digital image from QA operation. If the distance maintains constance between source(target) and image detector with constant distance to the center of spherical mechanical check device(SMCD), the size will be shown as a constant image at all times regardless of its direction exposed. For the test, two accurate hemispheres are made and put together which results in a sphere of the equilateral circle. It enables a variety of implementation of the existing mechanical check using digital image as follows: congruity level of radiation field and light field, size accuracy of radiation field and collimation field, gantry rotation isocenter check, collimation rotation isocenter check, room laser accuracy check, collimation rotation angle check, couch rotation angle check, and more. In addition, it has proved its practicability in checking isocenter congruity level as real time at the time of simultaneous rotation between gantry and couch that is applied to the non-coplanar field, which had been hard to apply as a device formed of existing flat or cube.

  • PDF

Development of Target-Controlled Infusion system in Plasma Concentration. PART2: Design and Evaluation (혈중 목표 농도 자동 조절기(TCI) 개발 PART2: 시스템 구현 및 평가)

  • 안재목
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.45-53
    • /
    • 2003
  • Based on the 4-compartmental pharmacokinetic model developed in PART1, target-controlled infusion(TCI) pump system was designed and evaluated. The TCI system consists of digital board including microcontroller and digital signal process(DSP), analog board, motor-driven actuator, user friendly interface, power management and controller. It provides two modes according to the drugs: plasma target concentration and effect target concentration. Anaesthetist controls the depth of anaesthesia for patients by adjusting the required concentration to maintain both plasma and effect site in drug concentration. The data estimated in DSP include infusion rate, initial load dose, and rotation number of motor encoder. During TCI operation, plasma concentration. effect site concentration, awaken concentration, context-sensitive decrement time and system error information are displayed in real time. Li-ion battery guarantees above 2 hours without power line failure. For high reliability of the system, two microprocessors were used to perform independent functions for both pharmacokinetic algorithm and motor control strategy.

Adaptive Filtering Processing for Target Signature Enhancement in Monostatic Borehole Radar Data

  • Hyun, Seung-Yeup;Kim, Se-Yun
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.2
    • /
    • pp.79-81
    • /
    • 2014
  • In B-scan data measured by a pulse-type monostatic borehole radar, target signatures are seriously obscured by two clutters that differ in orientation and intensity. The primary clutter appears as a nearly constant time delay, which is caused by internal ringing between antenna and transceiver in the radar system. The secondary clutter occurs as an oblique time delay due to the guided borehole wave along the logging cable of the radar antenna. This issue led us to perform adaptive filtering processing for orientation-based clutter removal. This letter describes adaptive filtering processing consisting of a combination of edge detection, data rotation, and eigenimage filtering. We show that the hyperbolic signatures of a dormant air-filled tunnel target can be more distinctly enhanced by applying the proposed approach to the B-scan data, which are measured in a well-suited test site for underground tunnel detection.

Design of Target Tracking System using Kalman Filtering (칼만필터링을 사용한 목표물 추적시스템의 설계)

  • 김종화;이만형
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.9
    • /
    • pp.636-645
    • /
    • 1988
  • A new filter algorithm is suggested improving structurally the conventional extended Kalman filter of which the performance is dependent on the selection of the reference axes, by use of line-of-sight axes and gain rotation technique. The implementation method using microcomputer which implements tracking Kalman filter is introduced in terms of hardware and software. Then, through the simulation the performance of suggested filter is compared with that of conventional extended Kalman filter and the possibility of the real time tracking of moving target is investigated.

  • PDF

Surf points based Moving Target Detection and Long-term Tracking in Aerial Videos

  • Zhu, Juan-juan;Sun, Wei;Guo, Bao-long;Li, Cheng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.11
    • /
    • pp.5624-5638
    • /
    • 2016
  • A novel method based on Surf points is proposed to detect and lock-track single ground target in aerial videos. Videos captured by moving cameras contain complex motions, which bring difficulty in moving object detection. Our approach contains three parts: moving target template detection, search area estimation and target tracking. Global motion estimation and compensation are first made by grids-sampling Surf points selecting and matching. And then, the single ground target is detected by joint spatial-temporal information processing. The temporal process is made by calculating difference between compensated reference and current image and the spatial process is implementing morphological operations and adaptive binarization. The second part improves KALMAN filter with surf points scale information to predict target position and search area adaptively. Lastly, the local Surf points of target template are matched in this search region to realize target tracking. The long-term tracking is updated following target scaling, occlusion and large deformation. Experimental results show that the algorithm can correctly detect small moving target in dynamic scenes with complex motions. It is robust to vehicle dithering and target scale changing, rotation, especially partial occlusion or temporal complete occlusion. Comparing with traditional algorithms, our method enables real time operation, processing $520{\times}390$ frames at around 15fps.

A Method of ISAR Geometric Calibration for Point Target Using Impulse-Radio UWB (임펄스 초광대역 레이다를 이용한 점표적의 ISAR 기하 보정 방법)

  • Yu, Jiwoong;Nikitin, Konstantin;Paek, Inchan;Jang, Jong Hun;Ka, Min-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.4
    • /
    • pp.397-403
    • /
    • 2015
  • In this paper, a method of ISAR geometric calibration is represented by using impulse-radio UWB radar. The ir-UWB is good for using a signal processing in time domain, so, it does not occur a multi-path or coupling problem. If a signal that between antennas and target is assumed a plane wave, a center of rotation in ISAR geometry model can be estimated by using point target. Before image is reconstructed with sinogram, the center of rotation can be calculated by using least square fitting. This method can be obtained a more contrast image, and a maximum value of entropy of image. The method, that estimates a center of rotation in received data, will be used a initial setup of instruments or a periodic compensation to reconstruct image. It would be useful in medical, security and surveillance imaging equipments that have a fixed geometry.

Sub-surface imaging and vector precision from high resolution down-hole TEM logging

  • Chull, James;Massie, Duncan
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.09a
    • /
    • pp.11-18
    • /
    • 2005
  • Filament inversion routines are highly effective for target definition whenever total-field DHTEM vectors can be obtained using three-component logging tools. However most cross-hole components contain significant noise related to sensor design and errors in observation of probe rotation. Standard stacking methods can be used to improve data quality but additional statistical methods based on cross-correlation and spatial averaging of orthogonal components may be required to ensure a consistent vector migration path. Apart from assisting with spatial averaging, multiple filaments generated for successive time-windows can provide additional imaging information relating to target geometry and current migration. New digital receiver systems provide additional time-windows to provide better tracking options necessary for high-resolution imaging of this type.

  • PDF

Use of Flattening Filter Free Photon Beams for Off-axis Targets in Conformal Arc Stereotactic Body Radiation Therapy

  • Smith, Ashley;Kim, Siyong;Serago, Christopher;Hintenlang, Kathleen;Ko, Stephen;Vallow, Laura;Peterson, Jennifer;Hintenlang, David;Heckman, Michael;Buskirk, Steven
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.288-297
    • /
    • 2014
  • Dynamic conformal arc therapy (DCAT) and flattening-filter-free (FFF) beams are commonly adopted for efficient conformal dose delivery in stereotactic body radiation therapy (SBRT). Off-axis geometry (OAG) may be necessary to obtain full gantry rotation without collision, which has been shown to be beneficial for peripheral targets using flattened beams. In this study dose distributions in OAG using FFF were evaluated and the effect of mechanical rotation induced uncertainty was investigated. For the lateral target, OAG evaluation, sphere targets (2, 4, and 6 cm diameter) were placed at three locations (central axis, 3 cm off-axis, and 6 cm off-axis) in a representative patient CT set. For each target, DCAT plans under the same objective were obtained for 6X, 6FFF, 10X, and 10FFF. The parameters used to evaluate the quality of the plans were homogeneity index (HI), conformality indices (CI), and beam on time (BOT). Next, the mechanical rotation induced uncertainty was evaluated using five SBRT patient plans that were randomly selected from a group of patients with laterally located tumors. For each of the five cases, a plan was generated using OAG and CAG with the same prescription and coverage. Each was replanned to account for one degree collimator/couch rotation errors during delivery. Prescription isodose coverage, CI, and lung dose were evaluated. HI and CI values for the lateral target, OAG evaluation were similar for flattened and unflattened beams; however, 6FFF provided slightly better values than 10FFF in OAG. For all plans the HI and CI were acceptable with the maximum difference between flattened and unflattend beams being 0.1. FFF beams showed better conformality than flattened beams for low doses and small targets. Variation due to rotational error for isodose coverage, CI, and lung dose was generally smaller for CAG compared to OAG, with some of these comparisons reaching statistical significance. However, the variations in dose distributions for either treatment technique were small and may not be clinically significant. FFF beams showed acceptable dose distributions in OAG. Although 10FFF provides more dramatic BOT reduction, it generally provides less favorable dosimetric indices compared to 6FFF in OAG. Mechanical uncertainty in collimator and couch rotation had an increased effect for OAG compared to CAG; however, the variations in dose distributions for either treatment technique were minimal.