• Title/Summary/Keyword: target mean resistance

Search Result 18, Processing Time 0.027 seconds

Estimation of load and resistance factors based on the fourth moment method

  • Lu, Zhao-Hui;Zhao, Yan-Gang;Ang, Alfredo H.S.
    • Structural Engineering and Mechanics
    • /
    • v.36 no.1
    • /
    • pp.19-36
    • /
    • 2010
  • The load and resistance factors are generally obtained using the First Order Reliability Method (FORM), in which the design point should be determined and derivative-based iterations have to be used. In this paper, a simple method for estimating the load and resistance factors using the first four moments of the basic random variables is proposed and a simple formula for the target mean resistance is also proposed to avoid iteration computation. Unlike the currently used method, the load and resistance factors can be determined using the proposed method even when the probability density functions (PDFs) of the basic random variables are not available. Moreover, the proposed method does not need either the iterative computation of derivatives or any design points. Thus, the present method provides a more convenient and effective way to estimate the load and resistance factors in practical engineering. Numerical examples are presented to demonstrate the advantages of the proposed fourth moment method for determining the load and resistance factors.

Center Pillar Design for High Bending Collapse Performance (굽힘 붕괴 성능 향상을 위한 센터 필라 설계)

  • Kang, Sungjong;Park, Myeongjae
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.4
    • /
    • pp.128-134
    • /
    • 2013
  • High bending collapse performance (maximum resistance force and mean resistance force) of body center pillar is an important design target for vehicle safety against side impact. In this study, effect of the upper section shape and the thickness of outer reinforcement on bending collapse performance was investigated for the center pillar of a large passenger car. First, through bending collapse analyses using simple models with uniform section, an optimized center pillar upper section was chosen. Next, bending collapse performance for various models of the actual center pillar with changing the thickness of outer reinforcement were analyzed. The finally designed model showed distinctive enhancement in bending collapse performance nearly without weight increase.

The invariant design of planar magnetron sputtering TFT-LCD

  • Yoo, W.J.;Demaray, E.;Hosokawa;Pethe, R.
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.3 no.2
    • /
    • pp.101-106
    • /
    • 1999
  • The main consideration factor to design a magnetron of the sputtering system for TFT-LCD metallization is high sheet resistance (Rs) uniformity which is provided by the high target erosion and high current efficiency. The present study has developed a rectangular magnetron for TFT-LCD to bve considered full target erosion and high film uniformity. After an aluminum-2 at.% and alloy target was installed in a magnetron source and the film was deposited on the glass of 600${\times}$720 mm, the Rs uniformity of the deposited film was measured as functions of the magnet tilt and magnet scanning configuration. And the target erosion profile was observed with the target voltage. When sputtered at 4mtorr and 10kW, the magnet tilt for the high Rs uniformity of 8.38% was 7mm. The plasma voltage at the dwell home and end for full-face target erosion, when scanned the magnetron was 120% compared to the mean voltage of the other area.

  • PDF

Proposal of Return Period and Basic Wind Speed Map to Estimate Wind Loads for Strength Design in Korea (강도설계용 풍하중 평가를 위한 재현기간과 기본풍속지도의 제안)

  • Ha, Young-Cheol
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.2
    • /
    • pp.29-40
    • /
    • 2018
  • Strength design wind loads for the wind resistance design of structures shall be evaluated by the product of wind loads calculated based on the basic wind speed with 100 years return period and the wind load factor 1.3 specified in the provisions of load combinations in Korean Building Code (KBC) 2016. It may be sure that the wind load factor 1.3 in KBC(2016) had not been determined by probabilistic method or empirical method using meteorological wind speed data in Korea. In this paper, wind load factors were evaluated by probabilistic method and empirical method. The annual maximum 10 minutes mean wind speed data at 69 meteorological stations during past 40 years from 1973 to 2012 were selected for this evaluation. From the comparison of the results of those two method, it can be found that the mean values of wind load factors calculated both probability based method and empirical based method were similar at all meteorological stations. When target level of reliability index is set up 2.5, the mean value of wind load factors for all regions should be presented about 1.35. When target level of reliability index is set up 3.0, wind load factor should be presented about 1.46. By using the relationship between importance factor(conversion factor for return period) and wind load factor, the return periods for strength design were estimated and expected wind speeds of all regions accounting for strength design were proposed. It can be found that return period to estimate wind loads for strength design should be 500 years and 800 years in according to target level of reliability index 2.5 and 3.0, respectively. The 500 years basic wind speed map for strength design was suggested and it can be used with a wind load factor 1.0.

The Comparison of Aerodynamic Measures in Korean Stop Consonants based on Phonation Types (한국어 파열음의 발성 유형에 따른 공기역학 측정치 비교)

  • Choi, Seong Hee;Choi, Chul-Hee
    • Phonetics and Speech Sciences
    • /
    • v.6 no.4
    • /
    • pp.195-203
    • /
    • 2014
  • The aim of this study was to investigate the effects of phonation types ([+/- aspirated], [+/- fortis]) on aerodynamic measures with Korean bilabial stops. Sixty-three healthy young adults (30 males, 33 females) participated to evaluate the VOEF (Voicing Efficiency) tasks with bilabial stop consonants /$p^h$/, /p/, /p'/ using Phonatory Aerodynamic System (PAS) Model 6600 (Kay PENTAX Corp, Lincoln Park, NJ). All VOEF measures were significantly influenced by phonation types except RANP(pitch range)(p <.01). For sound pressure, maximum SPL, mean SPL, and Mean SPL during Voicing have been shown to be significantly greatest in fortis stop /p'/ than aspirated /$p^h$/ and lenis stop /p/ (p<.001). On the other hand, mean pitch after lenis stop was significantly lower than after aspirated and fortis stops (p<.001). Peak expiratory airflow, Target airflow, and FVC (Expiratory volume) were significantly lowest in fortis stop /p'/ which might be associated with higher aerodynamic resistance while peak air pressure and mean peak air pressure during closure were significantly lower in lenis stop /p/. Additionally, AEFF (Aerodynamic efficiency) was significantly higher in fortis stop /p'/ than lenis stop /p/ as well as aspirated stop /$p^h$/ (p<.001). Thus, sound pressure, airflow parameters, and aerodynamic resistance made crucial roles in distinguishing fortis /p'/ from lenis stop /p/ and aspirated. Additionally, pitch and subglottal air pressure parameters were important aerodynamic characteristics in distinguishing lenis /p/ from fortis /p'/ and aspirated /$p^h$/. Therefore, accurate aspirated /p/ stop consonant should be elicited when collecting the airflow, intraoral pressure related data with patients with voice disorders in order to enhance the reliability and relevance or validity of aerodynamic measures using PAS.

Resistance of Plants to Herbicide (제초제(除草劑)에 대한 식물(植物)의 저항성(抵抗性))

  • Kim, Kil-Ung
    • Korean Journal of Weed Science
    • /
    • v.4 no.1
    • /
    • pp.96-106
    • /
    • 1984
  • Changes in weed floras and development of plant resistance to herbicides seemed to be closely related with increased and repeated use of herbicides. Herbicide use increased from 5% of the total consumption of pesticide in 1950 to 45% in 1976 in world basis. About 200 herbicides have been introduced to agriculture so as to control about 206 weed species which have been recorded important to human beings. In Korea, there was about 351 times in increased use of herbicides from 1966 to 1982. Interspecific selection by herbicide is mainly responsible for changes in weed floras and resulted in varying tolerance or susceptibility to herbicides, together with the changes of agricultural practices. The present trend toward continuous cereal cultivation throughout world will lead to type of changes in weed floras favorable to therophyte which can survive under unfavorable conditions as seeds rather than the types of geophyte which can survive unfavorable seasons as buds placed below soil surface. However, geophyte such as Sagitaria pygmaea, and Scirpus jurtcoides, and Cyperus rotundus and Cynodon dactylon in temperate warm climate become severe paddy weeds, presumably because of the removal of annual weeds by herbicides. Since differential tolerance to 2,4-D was firstly reported in Agrostis stolofera, about 30 species of weeds in 18 genera are presently known to have developed resistance to triazine herbicides. Resistance of weed biotypes to triazine herbicide is not mainly due to limited absorption and translocation or to the difference in metabolism, but is the result of biochemical changes at the site of metabolic activity, such as a loss of herbicide affinity for triazine binding site in the photosystem II complex of the chloroplast membrane. Genetical study showed that plastid resistance to triazine was wholly inherited through cytoplasmic DNA in the case of Brassica campestris. Plant tissue culture method can be utilized as an alternate mean of herbicide screening and development of resistance variants to herbicides as suggested by Chaleff and Parsons. In this purpose, one should be certain that the primary target process is operational in cell culture. Further, there are a variety of obstacles in doing this type of research, particularly development of resistance source and it's regeneration because cultured cells and whole plants represent different developmental state.

  • PDF

Development of Vancomycin Initial Dosage Guidelines to Achieve New Target Ranges (Vancomycin 초기 투여 용량 개선 방안)

  • Yoo, Jae-Young;Kim, Jung-Hyun;Lee, Yong-Won;Kim, Eun-Yeong;Sohn, Kie-Ho
    • Korean Journal of Clinical Pharmacy
    • /
    • v.20 no.3
    • /
    • pp.221-228
    • /
    • 2010
  • In 2009, American Journal of Health-System Pharmacy (AJHP) recommended that targeting vancomycin trough concentrations of 10 mg/L or more because of therapeutic failure and potential risk of developing vancomycin resistance. Therefore, new dosage guidelines that could achieve to these higher target were needed. The aims of this study were to develop dosage guidelines targeting new vancomycin trough concentration and to evaluate the performance of these new guidelines. All data analysis were performed using NONMEM(R). Population pharmacokinetic model was first developed from vancomycin dosage and concentration data collected retrospectively during routine therapeutic drug monitoring in 441 patients, then new vancomycin dosage guidelines were developed by using the model to predict vancomycin trough and peak concentrations in a simulated dataset. The estimates, such as, vancomycin concentration trough level, time to achieve target level, mean error were performed to evaluate and compare difference between conventional dosage and new dosage guidelines. The proposed dosage guidelines were predicted to achieve 43.5% of vancomycin trough level within 10~20 mg/L, which is significantly higher than current guidelines (26.3%). Time to achieve target trough level was 19.4 hours in new guidelines comparing to 93.1 hours in the conventional dosage. Thus, new vancomycin dosage guidelines have been developed to achieve new target trough concentrations earlier and more consistently than conventional guidelines.

A Study on Reliability of Current Ultimate Strength Design for Reinforced Concrete (현행(現行) 철근(鐵筋)콘크리트 극한강(極限强) 설계법(設計法)의 신뢰성(信賴性)에 관(關)한 연구(硏究))

  • Lee, Bong Hak
    • Journal of Industrial Technology
    • /
    • v.2
    • /
    • pp.3-11
    • /
    • 1982
  • Reliability analysis methods have been employed in this study to determine the safety index ${\beta}$ for flexure associated with reinforced concrete designs that are in accordance with current USD code of Korea. In reliability analysis, the mean first-order second-moment methods are employed. The following specific conclusions can be drawn from this study; 1) Levels of safety for reinforced concrete design, measured by ${\beta}$, vary from 2.8 to 3.8 in flexure depending on the limit state, the ratio of live load to dead load and the uncertainties. 2) Target reliability ${\beta}$ associated with reinforced concrete beams in flexure is assumed to be 3.5~4.0 in Korea. 3) Load factors and resistance factors in flexure associated with the current provisions contained in USD code generally seem to be too high. The writer concluded the factors as following; ${\phi}=0.8,\;{\gamma}_D=1.1\;{\gamma}_L=1.75$.

  • PDF

Room Temperature Fabrication of Organic Flexible Displays using Amorphous IZO Anode Film (비정질 IZO 애노드 박막을 이용한 유기물 플렉서블 디스플레이의 상온 제작)

  • Moon, Jong-Min;Bae, Jung-Hyeok;Jeong, Soon-Wook;Park, No-Jin;Kang, Jae-Wook;Kim, Han-Ki
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.7
    • /
    • pp.687-694
    • /
    • 2006
  • We report on the fabrication of organic-based flexible displays using an amorphous IZO anode grown at room temperature. The IZO anode films were grown by a conventional DC reactive sputtering on the polycarbonate (PC) substrate at room temperature using a synthesized IZO target in a $Ar/O_2$ ambient. Both x-ray diffraction (XRD) and high resolution electron microscope (HREM) examination results show that the IZO anode film grown at room temperature Is complete amorphous structure due to low substrate temperature. A sheet resistance of $35.6\Omega/\Box$, average transmittance above 90 % in visible range, and root mean spare roughness of $6\sim10.5\AA$ were obtained even in the IZO anode film grown on PC substrate at room temperature. It is shown that the $Ir(ppy)_3$ doped flexible organic light emitting diode (OLED) fabricated on the IZO anode exhibit comparable current-voltage-luminance characteristics as well as external quantum efficiency and power efficiency to OLED fabricated on conventional ITO/Glass substrate. These findings indicate that the IZO anode film grown on PC substrate is a promising anode materials for the fabrication of organic based flexible displays.

Investigation of Soil and Groundwater Contaminated by Gasoline and Lubricants Around a Railroad Station in S City, Korea

  • Lee, Hwan;Lee, Yoonjin
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.6
    • /
    • pp.529-540
    • /
    • 2012
  • Objective: This research was performed to evaluate the state of oil pollution in an area surrounding a railway station that has over 100 years of business history as a railway station in S City, Korea. The amount of polluted soil was estimated, and the target area for remediation was assessed in this study to restore the oil-polluted area. Methods: To accomplish this aim, five observation wells were installed for the sampling of groundwater, and soil was sampled at 33 points. Electric resistance studies and a trench investigation were undertaken to understand the geological conditions of the site, and the groundwater movement in this area was simulated by MODFLOW. Physiochemical analyses were conducted to determine the quality of the groundwater and the current state of oil pollution influenced by that of the soil. Results: The mean level of total petroleum hydrocarbons (TPHs) in this area was 1,059 mg/kg, and the area for remediation was determined to be 7,610 mg/kg. Levels of benzene, toluene, ethylbenzene, and xylene (BTEX) were determined to be under the legal standard. Conclusion: In terms of depth, the biggest area polluted by TPH found was between 0 and 1 m from ground level, and the affected area was 5,900 $m^3$. TPHs were not detected in groundwater. Diesel and lubricating oil were the main causes of TPH pollution at this railway station.