• Title/Summary/Keyword: tapered implant

Search Result 57, Processing Time 0.017 seconds

Comparison of the effects of two different styles of orally prescribing prednisolone on postoperative sequelae of surgical extraction of an impacted mandibular third molar: a single-blind randomized study

  • Mohammed Mousa H. Bakri;Faisal Hussain Alabdali;Rashed Hussain Mahzari;Thamer Jabril Rajhi;Norah Mohammed Gohal;Rehab Abdu Sufyani;Asma Ali Hezam;Ahtesham Ahmed Qurishi;Hamed Mousa Bakri;Fareedi Mukram Ali
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.50 no.1
    • /
    • pp.27-34
    • /
    • 2024
  • Objectives: Surgical intervention for removal of an impacted third molar can lead to significant pain and swelling. Corticosteroids show promise for mitigating postoperative sequelae across various surgical contexts. The use of corticosteroids following minor oral surgery, though controversial, has already been proven effective. However, little research has explored peroral prescription of corticosteroids despite its convenience for outpatients and for non-surgeons like implantologists and periodontists and others who don't have access to needle injections. The aim of this study was to address a void in the literature by comparing the effects of two styles of preoral administration of prednisolone after surgical removal of the mandibular third molar and to determine which style minimizes postoperative sequelae. Materials and Methods: A randomized, split-mouth clinical study was conducted to investigate the efficacy of two different styles of preoral prednisolone in mitigating postoperative sequelae following surgical extraction of impacted mandibular third molars. Fifteen participants were enrolled in the study. Random selection was used to determine the prescription style for the right and left mandibular arch. Group A included those who received a single dose of prednisolone 25 mg, while group B received prednisolone 5 mg postoperatively for a period of three days (5 mg three times/day on the first postoperative day, 5 mg twice/day on the second postoperative day; 5 mg once/day on the third postoperative day). Results: There was a significant difference in the distance between the corner of the mouth and tragus, which decreased with the time interval with respect to group B when compared to group A. Conclusion: The present study showed that a three-day tapered dose of prednisolone postoperatively was more effective in reducing post-extraction sequelae than a single-dose regimen.

EFFECTS OF THE ER,CR:YSGG LASER ON BONE BED PREPARATION WITH VARIOUS LASER TIPS

  • Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Hong, Seong-Doo;Lee, Shin-Jae;Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.255-260
    • /
    • 2008
  • STATEMENT OF PROBLEM: Preparation of implant beds with lasers is considered a safe and reliable method, but the accuracy of this technique has not been examined. PURPOSE: The purpose of this study was to evaluate the accuracy and effectiveness of implant bed preparation using an Er,Cr:YSGG laser. MATERIAL AND METHODS: An Er,Cr:YSGG laser was applied to pig rib bone. The laser was employed at a 5.75 W power setting, 30 Hz/sec pulse repetition, and 70 ${\mu}s$ pulse duration with 50 % water and 60% air spray. According to laser tips the groups were divided as follows; Group 1: paralleled - shaped sapphire tip (0.6 mm${\Phi}$), Group 2: paralleled - shaped zirconia tip (0.6 mm${\Phi}$), Group 3: tapered sapphire tip (0.4 mm${\Phi}$). The Er,Cr:YSGG laser tip was separated by 1 mm from the bone and applied for 15 seconds in a non-contact mode. After the application, the bone was sectioned for specimens. Histologic measurements were determined by computerized morphometry. The length of the prepared bone surface was measured and the width of the entrance was measured. The results were analyzed with one-way ANOVA (P<0.05). RESULTS: The prepared length of group 3 was longer than that of group 2. The prepared bone width was larger than the width of the laser tip in every group. Additional bone removal was observed adjacent to the prepared area and displayed an irregular surface. CONCLUSION & DISCUSSION: Different cutting effects were observed according to the laser tip, emphasizing the importance of proper tip selection in the clinical setting. This preliminary study supported the existence of hydrokinetic effects.

Regenerative Effects of Alloplastic Grafts in Rat Periodontal Fenestration Defects (백서 치조골 천공결손부에서의 합성골 이식재의 재생효과)

  • Gang, Yun-Kyung;Park, Joon_Bong;Kwon, Young-Hyuk;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.2
    • /
    • pp.317-332
    • /
    • 2001
  • The purpose of this study was to investigate effects of the natural coral(NC) and the hydroxyapatite/calcium sulfate hemihydrate(HA/CS) on an early stages of wound healing in the rat periodontal fenestration defects. In this experiment, twelve male rats(Mean : 520g in BW) aged 8 to 9 months were used. Experimental periodontal fenestration defects were surgically created with tapered fissure bur at the buccal surface of the left mandibular 1st, 2nd molars. The buccal aspects of molar roots were carefully denuded of their periodontal ligament through a bony window created in the left mandibles of rats under general anesthesia. Each experimental periodontal fenestration defect was grafted with natural coral and HA/CS, randomly. An area without bone graft was assigned for negative control group. At 10,35 days, rats were serially sacrificed via intracardiac perfusion with 2.5% glutaraldehyde and specimens were processed with Hematoxylin-Eosin stain for light microscopic evaluation. The results of this study were as follows : 1. The defect areas were filled with dense connective tissues at 10 days in control group. But in the test(NC, HA/CS)groups, the connective tissues around graft materials were formed more loosely and the response of inflammation by graft materials itself was not found. 2. The defect areas were filled with new osteoid tissues and new cementum was not formed on the cut root surface at 35 days in the control group. 3. New osteoid tissue formation was more prominent at 35 days in control than test groups. 4. The NC and HA/CS particles were encapsulated by loose connective tissues at 10 days and by dense connective tissues at 35 days, respectively. 5. In the test groups, resorption of graft particles was not found through the experimental time. From the above results, natural coral and hydroxyapatite/calcium sulfate hemihydrate may be biocompatible and osteoconductive and have a weak adverse reaction to the periodontal tissues.

  • PDF

Evaluation of Insertion of torque and Pull-out strength of mini-screws according to different thickness of artificial cortical bone (다양한 교정용 미니 스크류의 인공 피질골 두께에 따른 삽입 토오크와 Pull-out 강도 비교)

  • Song, Young-Youn;Cha, Jung-Yul;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.37 no.1 s.120
    • /
    • pp.5-15
    • /
    • 2007
  • Objective: The purpose of this study was to evaluate the mechanical performance of mini-screws during insertion into artificial bone with use of the driving torque tester (Biomaterials Korea, Seoul, Korea), as well as testing of Pull-out Strength (POS). Methods: Experimental bone blocks with different cortical bone thickness were used as specimens. Three modules of commercially available drill-free type mini-screws (Type A; pure cylindrical type, Biomaterials Korea, Seoul, Korea, Type B; partially cylindrical type, Jeil Medical, Seoul, Korea, Type C; combination type of cylindrical and tapered portions, Ortholution, Seoul, Korea), were used. Results: Difference in the cortical bone thickness had little effect on the maximum insertion torque (MIT) in Type A mini-screws. But in Type B and C, MIT increased as the cortical bone thickness Increased. MIT of Type C was highest in all situations, then Type B and Type A in order. Type C showed lower POS than Type A or B in all situations. There were statistically significant correlations between cortical bone thickness and MIT, and POS for each type of the mini-screws. Conclusion: Since different screw designs showed different insertion torques with increases in cortical bone thickness, the best suitable screw design should be selected according to the different cortical thicknesses at the implant sites.

Healing Effects of Demineralized Freeze - Dried Bone Allograft and Deproteinized Bovine Bone Mineral on Periodontal Fenestration Defect in Rats (탈회 동결 건조골과 탈단백 우골의 백서 치조골 천공결손에 대한 치유 효과)

  • Shin, Joong-Ho;Kwon, Young-Hyuk;Park, Jun-Bong;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.1
    • /
    • pp.73-91
    • /
    • 2001
  • The present study was performed to compare effects of demineralized freeze-dried bone allograft(DFDBA) with deproteinized bovine bone mineral(DBBM) on periodontal fenestration defect in rats. Twelve adult male rats weighing 500 to 540 grams were used in this study. Periodontal fenestration defects were surgically created with tapered fissure bur(${\Phi}1mm$) at the left side of buccal surface of the mandible. The defect size was from anterior border of the first molar to anterior of the ascending ramus mesiodistally and from just below the alveolar crest to apically 1.5-2mm area apicocoronally with 2mm in depth. Rats were divided into control group, test group I and II. Four defects were assigned to the test group I grafted with DBBM and other 4 defects were assigned to the test group II grafted with DFDBA. The rest of defects were the negative control group. At 10 days and 35 days after surgery, 12 rats were sacrificed through intracardiac perfusion and specimens were obtained prepared with Hematoxylin-Eosin stain for light microscopic evaluation. The results of this study were as follows : 1. In the control group, new bone, osteoid, dense connective tissue were observed in the defects at 10 days. new bone formation was not found but loose connective tissue was formed in the defect and fibrous encapsulation of graft materials was shown in two test groups at 10 days. 2. In all groups, new bone formation was shown in the defect at 35 days. And in the control group, bone formation increased at 35 days than at 10 days. 3. In the test group I and II at 35 days, graft materials were combined with new bone and joined host bone. There was very close contact between new bone, graft materials, and host bone with no gaps. 4. In the test group I and II, new bone formation was similar to that in the control group but not exeeded. In conclusion, in the test group I new bone formation was similar to that in the test group II at 35 days, but there was infiltration of inflammatory cells at 10 days. DFDBA and DBBM were considered as the biocompatible graft materials and effective in the regeneration of new bone.

  • PDF

Mechanical analysis of the taper shape and length of orthodontic mini-implant for initial stability (교정용 미니임플랜트의 초기 안정성에 대한 원추형태와 길이에 관한 기계역학적 분석)

  • Kim, Jong-Wan;Cho, Il-Sik;Lee, Shin-Jae;Kim, Tae-Woo;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.36 no.1 s.114
    • /
    • pp.55-62
    • /
    • 2006
  • Orthodontic mini-implants, despite its usefulness as anchorage, have some limits such as loosening. Therefore, various shapes and lengths have been studied. The aim of this study is to analyze the shape and length of mini-implants mechanically. The shapes of mini-implants (1.6 mm, Dual Top, Jeil Medical Co., Seoul, Korea) were cylindrical and taper. The lengths of mini-implants were 6 mm and 8 mm. The tested groups were 5 groups (cylindrical 6 mm, cylindrical 8 mm, taper 6 mm, taper 8 mm and taper 8 mm modified whose thread is reduced from the middle to upper part). All were inserted and removed on the polyurethane foam with the torque measured. During insertion and removal, the taper shape needed higher torque than the cylindrical shape, and the 8 mm length than the 6 mm length (p<0.001). The taper 6mm group showed superior insertion torque (p<0.001) and similar removal torque to the cylindrical 8 mm group. The taper 8 mm modified group with gradually reduced threads, showed continuous high removal torque after the peak. The initial mechanical stability can be provided by the tapered shape and also, affected by length and thread design.

Comparison of palatal bone thickness between 3D model and lateral cephalometric radiograph (성인 구개부 측모두부계측방사선 사진과 3D model의 골두께 비교)

  • Jang, Min-Guk;Lee, Jin-Woo;Cha, Kyung-Suk;Chung, Dong-Hwa;Lee, Sang-Min
    • The korean journal of orthodontics
    • /
    • v.41 no.5
    • /
    • pp.312-323
    • /
    • 2011
  • Objective: This study compared the bone thickness of the palate between lateral cephalogram and 3D model measurements. Methods: The subjects consisted of 30 adults (15 men,15 women) with a normal skeletal pattern and occlusion. The CT images were transformed to a 3D model, and were compared with the cephalometric image. Descriptive statistics for each variable were calculated. Results: In the 3D CT model, the mid-palatal area was the thickest part. It became thinner as the palate tapered laterally. In the male group, the thinnest portion was positioned 6 mm away from the mid-palate, while in the female group the thinnest portion was 8mm away from the mid-palate. Correlation analysis between the lateral cephalometric and 3D CT model revealed a significant correlation except in the mid palatal area and the area 2 mm lateral to the mid-palate in men, whereas there was a significant relationship in every area in the women. In both men and women, the highest correlation appeared in the area 8 mm lateral to the mid palate. Conclusions: Using regression analysis, an actual prediction of the bone thickness between the measured bone thickness of the lateral cephalometric radiograph and 3D model was made. This will provide useful information for mini-implant length selection when inserting into the palate.