테이프 배열이 3본-도체의 교류손실 특성에 미치는 영향 (Influence of tape′s arrangements on AC Loss Characteristics in a 3-conductor)

  • 조영호;허대행;류경우;최병주;황시돌
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.260-262
    • /
    • 2003
  • AC loss is an important issue in the design of high-T$_{c}$, superconducting power cables which consist of a number of Bi-2223 tapes wound on a cylindrical former. In this paper, the ac loss characteristics in the 3-conductor have investigated experimentally. The loss test results indicate that the ac loss is not related to the arrangement of Bi-2223 tapes, contact position and applied frequency. The measured losses in face-to-face arrangement are larger than those in edge-to-edge arrangement. The measured losses in the 3-conductor also agree well with the sum of the transport losses measured in each Bi-2223 tape.e.

  • PDF

선회충돌제트에 의한 배열 칩의 열전달 특성에 관한 실험적 연구 (An Experimental Study on Heat Transfer Characteristics of Arrangement Chips by Swirl Jet Impingement)

  • 최재욱;전영우;정인기;박시우
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권4호
    • /
    • pp.624-631
    • /
    • 2004
  • The experimental study on heat transfer characteristics of protruding heated block array as conducted to investigate and to compare the performance of impinging single circular jet in fully developed tube with a twisted tape as a swirl generator. The effects of jet Reynolds number(Re=8700, 13800, 20000. 26500), dimensionless jet-to-block distance(H/d=1. 3, 5. 7) and swirl number(S=0.11, 0.23, 0.30) of the swirl jet on the average Nusselt number for each block and all blocks have been examined. Measurements of heat transfer rate on block surfaces were used naphthalene sublimation technique. Mean velocity and turbulence intensity of the jet along the axis were measured. Potential core length of the jet was 5 times of nozzle diameter because it was fully developed and initially turbulent. With the twisted tape in the nozzle, heat transfer coefficients were higher than those without the twisted tape. which are mainly caused with increasing the jet Reynolds number and swirl number.

인접 교류전류가 Bi-2223테이프의 통전손실에 미치는 영향 (Effect of the Neighboring Tape′s AC Currents on Transport Current Loss of a Bi-2223 Tape)

  • 류경우;최병주
    • 한국전기전자재료학회논문지
    • /
    • 제14권3호
    • /
    • pp.251-256
    • /
    • 2001
  • Bi-2223 tapes have been developed for low-field power applications at liquid nitrogen temperature. When the Bi-2223 tapes are used in an application such as a power transmission cable or a power transformer, they are supplied with an AC transport current simultaneously. AC loss taking into account such real applications is a crucial issue for power applications fo the Bi-2223 tapes to be feasible. In this paper, the transport losses for different AC current levels and arrangements of the neighboring tapes have been measured in a 1./5 m long Bi-2223 tape. The significant increase of the transport losses due to neighboring tape's AC currents is observed. An increase of the transport losses caused by a decrease of the Bi-2223 tape's critical current is a minor effect. The measured trasprot losses could not be explained by a dynamic resistance loss based on DC voltage-current characteristics in combination with the neighboring tape's AC currents.The trasport losses do not depend on the frequency of the neighboring tape's AC currents but is arrangements in the range of small current especially.

  • PDF

장척 Bi-2223/AgMgNi 테이프의 자기자계손실 특성 (Self-field Loss Characteristics of a long Bi-2223/AgMgNi Tape)

  • 류경우;박권배;차귀수;최경달;이지광;한송엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권4호
    • /
    • pp.240-245
    • /
    • 2000
  • The self-field losses in a long multifilamentary Bi-2223/AgMgNi tape with varying transport current, voltage tap configurations, frequency and tape arrangements were investigated. Experimental results show that the measured losses are strongly dependent on voltage gap configurations but independent on tape arrangements. All voltage taps except the center tap are found to agree well with those predicted by Norris for an elliptical conductor. The self-field losses are purely hysteretic in nature in the range of applied frequencies for the transport currents below the critical current.

  • PDF

해석적인 방법과 수치적인 방법에 의한 고온초전도테이프의 결합손실 계산 (Calculation of Coupling Loss in a HTS Tape by using Analytic Method and Numerical Method)

  • 심정욱;이희준;차귀수;이지광;한송엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권6호
    • /
    • pp.309-315
    • /
    • 1999
  • Coupling loss is generated by the time-varying external magnetic field in the normal matrix of the multi-filamentary HTS tape. This paper calculates the coupling loss in the HTS tape. Analytic calculation of the coupling loss cannot consider the effect of the different shapes and the arrangement of the filaments. Numerical calculation by using finite element method and analytic calculation of the coupling loss have been done in this paper and results of two calculations have been compared. Transverse magnetic field and longitudinal magnetic field were considered as the external field.

  • PDF

자장방향이 적층 Bi-2223도체의 자화손실에 미치는 영향 (Effect of Field Orientation on Magnetization Loss in a Stacked Bi-2223 Conductor)

  • 류경우;김현준
    • 한국전기전자재료학회논문지
    • /
    • 제16권1호
    • /
    • pp.77-82
    • /
    • 2003
  • The ac loss is an important issue in the design of high-Tc superconducting power devices such as transformers and cables. In these devices many Bi-2223 tapes are closely stacked together and exposed to alternating magnetic fields that can have different orientations with respect to a tape. In such arrangement the magnetization loss is influenced by the screening current induced in adjacent tapes and thus different from that in a single tape. This stacking effect was experimentally investigated by measuring the magnetization loss in a stack, which consists of a number of tapes. First the magnetization loss in the single tape was measured in order to confirm the reliability of the loss data measured in the stack. The results for the single tape coincide well will the loss characteristics described in other previous works. For the stack In parallel and longitudinal magnetic fields the measured loss is Independent of both the number of tapes and stacking type. The longitudinal magnetization loss Is well explained rather by the slab model for decoupled filaments. For the tall stack in perpendicular field the measured loss at low fields is greatly decreased, compared to the loss of the single tape. However the loss at high fields is unaffected. These loss behaviors in the tall stack are well described by the slab model for full coupling.

HTS 선재에 따른 초전도 핵융합 마그넷용 고온초전도 전류도입선의 개념설계 (Conceptual Design of High-Tc Superconducting Current leads for Superconducting Nuclear Fusion Magnets with respect to various HTS tapes)

  • 장재영;장기성;김영재;최석진;조현철;주승열;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권1호
    • /
    • pp.32-36
    • /
    • 2010
  • Superconducting current leads are indispensible for reducing power loss when subjecting current into superconducting magnets. HTS(High-Tc superconducting) current leads are divided into two types; one is bulk type and the other is tape type. In this paper, conceptual design on the HTS current leads which adopts tape type for nuclear fusion magnets is carried out using magnetic field analysis and thermal analysis. When large current flows through superconducting current leads, strong self magnetic field is generated and applied to the superconducting tapes. This phenomenon leads to the critical current decrease of the superconducting tape. Therefore, we analyzed magnetic field distribution of current leads and found the proper arrangement with respect to the various HTS tapes. In addition to the magnetic field analysis, heat leak through the current leads was also calculated to know which HTS tape is superior than others in thermal aspect. Magnetical field analysis and calculation of heat leak are performed to design 2 kA class HTS current leads.

고온초전도 BSCC02223 장선재 제조를 위한 압출공정의 최적화 (Optimization of extrusion process for long-length multi-filaments of BSCCO 2223 superconductor tape)

  • 조기현;최종웅;유재무;고재웅;김해두
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.230-235
    • /
    • 2000
  • The extrusion process for long-length multi-filaments of BSCCO 2223 superconductor tape has been investigated with aids of Finite Element Method and experimental inspection. Since the arrangement of filaments in matrix material has characteristic of rotational symmetry, a 2-dimensional commercial FEM package, DEFORM-2D, was adopted to simulate extrusion process with different variables such as hardness of sheath material, lengths of each filament and arrangement. From the FEM analysis, since the inner filaments move faster than the outer one, distribution of filaments is needed to be optimized. In the case of pure Ag matrix, undesirable non-uniform distribution of filament was obtained due to low hardness of sheath material. Dummy sample(brass (sheath) and talc powder(filament)), however, which has relatively high hardness of sheath material, had been produced with desirable results. Therefore, it is necessary to optimize hardness of sheath material, extrusion temperature and billet design.

  • PDF

단면이 원형인 토로이드 권선의 자속밀도 계산 (Magnetic Field Calculation of Toroidal Winding with Circular Section)

  • 이상진
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권1호
    • /
    • pp.28-31
    • /
    • 2010
  • A magnetic field calculation method for toroidal type winding which has circular section was developed. At first, the equation for magnetic field by single filament coil was extended using numerical integration to estimate the entire interesting region of solenoid, especially winding region itself. And then, the magnetic field by toroidal arrangement of solenoids was computed with a coordinate transformation of vector fields. The superconducting magnet with toroidal arrangement can be made up of several tens of solenoid type double pancake windings for some applications such as superconducting magnetic energy storage system(SMES). In this system, the field calculation on the high-Tc superconducting(HTS) tape itself is very important because the entire system can be reached to a fault by magnetic stress of conductor or the critical current of superconducting tape can be dramatically reduced under its self field condition. To make matters worse, 3-dimensional analysis is indispensable for this type of magnet and the most of commercial programs with finite element method can be taken too much time for analysis and design. In this paper, a magnetic field calculation method for toroidal type winding with circular section was induced.

고온초전도 변압기의 교호 배치 권선과 동심형 배치 권선의 비교 (Comparison of Reciprocal and Concentric Winding Arrangement of HTS Transformer)

  • Kim, Sung-Hoon;Kim, Woo-Seok;Lee, Sang-Jin;Park, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won;Han, Jin-Ho;Hahn, Song-yop;Park, Chan-Bae
    • Progress in Superconductivity
    • /
    • 제5권1호
    • /
    • pp.61-64
    • /
    • 2003
  • In HTS transformer with double pancake windings, the perpendicular component of leakage magnetic flux density ($B_{r}$ ) applied to HTS tapes of double pancake windings of HTS transformer acts as a cause to decrease the critical current in HTS tape. So, in this paper, HTS transformer with reciprocal arrangement winding is designed. And in order to investigate the$ B_{r}$ applied to HTS windings, the 2-D non-linear electromagnetic analysis of HTS transformer is performed by using the OPERA 2D. The maximum $B_{r}$ applied to winding of HTS transformer is 0.112 T and the characteristics of HTS transformer were also obtained. But in this type of winding arrangement, reciprocal arrangement, the generated ac-loss to the HTS windings is very high because of the applied $B_{r}$ to HTS windings. Therefore, in order to reduce the generated ac-loss to the HTS windings, the new design of HTS transformer with concentric winding arrangement is presented in this paper and the 2-D non-linear electromagnetic analysis and the ac-loss for HTS transformer with the concentric winding arrangement is also carried out.