• 제목/요약/키워드: tape

검색결과 1,905건 처리시간 0.031초

LCD Driver IC Assembly Technologies & Status

  • Shen, Geng-shin
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2002년도 International Symposium
    • /
    • pp.21-30
    • /
    • 2002
  • According the difference of flex substrate, (reel tape), there are three kind assembly types of LCD driver IC is COG, TCP and COF, respectively. The TCP is the maturest in these types for stability of raw material supply and other specification. And TCP is the major assembly type of LCD driver IC and the huge demand from Taiwan's large TFT LCD panel house since this spring. But due to its package structure and the raw material applied in this package, there is some limitation in fine pitch application of this package type, (TCP). So, COF will be very potential in compact and portable application comparison with TCP in the future. There are three kinds assembly methods in COF, one is ACF by using the anisotropic conductive film to connect the copper lead of tape and gold bump of IC, another is eutectic bonding by using the thermo-pressure to joint the copper lead of tape and gold bump of IC, and last is NCP by using non-conductive paste to adhere the copper lead of tape and gold bump of IC. To have a global realization, this paper will briefly review the status of Taiwan's large TFT panel house, the internal driver IC design house, and the back-end assembly house in the beginning. The different material property of raw material, PI tape is also compared in the paper. The more detail of three kinds of COF assembly method will be described and compared in this paper.

  • PDF

줄자 및 사진촬영 측정을 이용한 어깨뼈 벌림 측정에 대한 신뢰도 연구 (A Reliability Study of Tape and Photography Measurement Techniques for Scapular Position)

  • 김문환;윤성준;하성민
    • 한국전문물리치료학회지
    • /
    • 제20권3호
    • /
    • pp.74-80
    • /
    • 2013
  • The purpose of this study was to determine the reliability of distance measurements from the medial border of the scapula to the spinous process of the thoracic vertebrae when obtained using tape and photography measurements. The study included 20 healthy subjects (10 males, 10 females); for a total of 40 scapula measurements. The distance measurements made using tape or photography methods were conducted with the subject in a standing position. Repeated tape and photography measurements were conducted in two sessions on different days by two examiners to assess the inter-rater and intra-rater reliability of the two methods. The reliability of scapular distance measured using tape and photography methods was tested using intraclass correlation coefficients (ICC(3,1)) and the standard error of measurement (SEM). The inter-rater reliability of the tape measurement method was excellent (ICC=.77) and the intra-rater reliability was fair to good (ICC=.74). The inter-rater and intra-rater reliabilities of the photography measurement method were excellent (ICC=.76 and .76 respectively). Our results suggest that photography measurement is an objective and qualitative measurement tool for scapular distance measurements.

꼬임식 테이프가 설치된 사각 덕트에서 스월유동이 미치는 열전달과 마찰계수 (Effects of Swirl Flow Generated by Twisted Tape on Heat Transfer and Friction Factor in a Square Duct)

  • 강호근;아리바시아크리시나 부트라;안수환
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.117-120
    • /
    • 2008
  • Numerical simulations and experiment of a hydrodynamic and thermally developed turbulent flow through square ducts (3.0 ${\times}$ 3.0 cm) with twisted tape inserts and with twisted tape inserts plus interrupted ribs are conducted to investigate regionally averaged heat transfer and friction factors. Turbulent swirl flows having Reynolds numbers ranging from 8,900 to 29,000, a rib height-to-channel hydraulic diameter(e/D$_h$) of 0.067, and a length-to-hydraulic diameter(L/D$_h$) of 30, are considered. The square ribs are arranged to follow the trace of the twisted tape and along the flow direction defined as axial interrupted ribs. The twisted tape has 0.1 mm thick carbon steel sheet with diameter of 2.8 cm, length of 90 cm, and 2.5 turns. Each wall is composed of isolated aluminum sections, and two cases of surface heating are set. The results show that uneven surface heating enhances the heat transfer coefficient over uniform heating conditions, and square ducts with twisted tape inserts plus interrupted ribs produces the best overall transfer performance.

  • PDF

캠-슬라이더 메커니즘 테이프 피더의 성능평가에 관한 연구 (A Study on the Performance Analysis for a Tape Feeder with Cam-slider Mechanism)

  • 전병철;조명우;문찬영;이수진;최진화
    • 한국정밀공학회지
    • /
    • 제23권5호
    • /
    • pp.177-183
    • /
    • 2006
  • A tape feeder is an important feeding device to supply micro-chips such as 1005 and 0603 components to PCB in SMT process. Traditionally, tape feeding methods using sprocket wheel mechanism has been used for the pickup system of chip-mounters. However, there is growing needs for new feeding mechanism with high accuracy and confidence as electric components are getting much smaller. Thus, recently, a tape feeder using cam-slider mechanism is developed to meet such requirements. The major advantages of developed system are; significantly reduced indexing and backlash errors, slim and compact design, and improved repetitive capacity compared to existing system. In this paper, the performance evaluation criteria for the developed tape feeder are suggested. Stability against induced vibration, positioning accuracy, cycle time, durability and supply error rate are estimated using developed self testers. As a result, the excellence of developed tape feeding mechanism is validated using the effective rating methods.

원관내의 이상선회유동 특성에 관한 연구 (The study on the Two-Phase Swirl Flow Characteristics in Cylindrical Pipe)

  • 차경옥;김재근
    • 한국자동차공학회논문집
    • /
    • 제4권1호
    • /
    • pp.187-197
    • /
    • 1996
  • Many investigations have been made to determine the pressure drop and heat transfer characteristics for single phase flow in tape generated swirl flow. But few studies have been carried out to investigate the heat transfer in two component, two phase swirl flow with non-boiling. An experimental study has been conducted to determine the effects of tape twist ratios on two phase convective heat transfer coefficients, pressure drop, and void fraction distribution in a non-boiling, air-water, two phase flow. The flow conditions were both swirl and non swirl flows. The internal diameter of the test section is 42.5mm. The tape twist ratios of pitch to diameter ratio varied from 4.0 to 10.6. The heating conditions were isothermal and nonisothermal. The flow patterns identified with experiments were bubbly, bubbly-slug, slug, and slug-annular flow in up-flow. This study has concluded that no significant difference in void fraction distribution were observed both isothermal and nonisothermal conditions, the pressure drop for two phase flow with twisted tape swirler increase as the tape twist ratio decrease, and that values of two phase heat transfer coefficient increase when the tape twist ratio decreases.

  • PDF

ANALYSIS OF ADHESIVE TAPE ACTIVATION DURING REACTOR FLUX MEASUREMENTS

  • Bignell, Lindsey Jordan;Smith, Michael Leslie;Alexiev, Dimitri;Hashemi-Nezhad, Seyed Reza
    • Nuclear Engineering and Technology
    • /
    • 제40권1호
    • /
    • pp.93-98
    • /
    • 2008
  • Several adhesive tapes have been studied in terms of their suitability for securing gold wires into positions for neutron flux measurements in the reactor core and irradiation facilities surrounding the core of the Open Pool Australian Light water (OPAL) reactor. Gamma ray spectrometry has been performed on each irradiated tape in order to identify and quantify activated components. Numerous metallic impurities have been identified in all tapes. Calculations relating to both the effective neutron shielding properties of the tapes and the error in measurement of the $^{198}Au$ activity caused by superfluous activity due to residual tape have been made. The most important identified effects were the prolonged cooling times required before safe enough levels of radioactivity to allow handling were reached, and extra activity caused by residual tape when measured with an ionisation chamber. Knowledge of the most suitable tape can allow a minimal contribution due to these effects, and the use of gamma spectrometry in preference to ionisation chamber measurements of the flux wires is shown to make all systematic errors due to the tape completely negligible.

목 폄 시 탄력성 테이프의 신장력 차이가 전방머리자세 증후군의 근수축 개시시간에 미치는 영향 (The Effect of Different Elastic Tape Expansibilities on the Onset Time of Muscle Contraction during Neck Extension for Forward Head Posture Syndrome)

  • 윤정규
    • PNF and Movement
    • /
    • 제20권3호
    • /
    • pp.331-340
    • /
    • 2022
  • Purpose: Thisstudy aimed to identify the effect of varying the expansibility of elastic tape on the onset time of muscle contraction during neck extension for forward head posture syndrome. Methods: Forty-five young adults with forward head posture syndrome volunteered to participate and were randomly assigned to one of three groups according to the expansibility of the elastic tape (25%, 50%, 75%). The onset time of muscle contraction for the neck extensor during neck extension was measured using an electromyographic system (Free EMG, BTS, Italy). Multivariate analysis of variance was employed to determine the effect of different expansibilities of elastic tape on the onset time of muscle contraction during neck extension for forward head posture syndrome. When there was a statistically significant difference by MANOVA, Scheffe was used as a post-hoc test. The level of significance was set at α=0.05. Results: In the comparison of the onset time of muscle contraction of varying elastic tape expansibilities and measurement times, there was a significant difference between the groups (Lt. UT, Lt. SCM, Rt. SCM) (p < 0.05), but there was no significant difference in the interaction between the measurement time and the group, between the measurement time (p > 0.05). Conclusion: In the neck extension, 75% of the tape extensibility in the Lt. UT and both SCM shortened the muscle contraction onset time.

크랙에 의한 Bi-2223/Ag 테이프의 임계전류 변화 (The change of critical current with crack formation in a Bi-2223/Ag tape)

  • 박을주;설승윤
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.249-252
    • /
    • 2002
  • The change of critical current with a crack formation in a Bi-2223/Ag tape was studied by experimental and numerical analyses. Critical current of Bi-2223/Ag tape was measured with a continuous DC-power supply. The current-voltage relation of a Bi-2223/Ag tape is measured by the four point method. Numerical method is used to solve two dimensional heat conduction equation. By comparing the experimental and numerical results, the validity of numerical method is verified.

  • PDF

이중절연 자기융착테이프 제조기술 (Manufacturing technology of two-layer self bonding insulating tape)

  • 조용석;이철호;심대섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.890-893
    • /
    • 2001
  • Two-layer self bonding insulating tape consists of butyl rubber(IIR ; Isobutylene-isoprene rubber) adhesive layer and polyethylene protective film. Butyl rubber have inherent characteristics such as resistance to corrosion and water, low temperature flexibility, excellent electrical insulating properties also resistance to environmental effect such as ozone and ultraviolet. Polyethylene film was used for the purpose of good insulating properties and resistance to ozone and ultraviolet. The tape was manufactured using extrusion and calender method.

  • PDF

Bi-2223테이프의 사고전류 특성 (Fault Current Characteristics of a Bi-2223 Tape)

  • 류경우;차귀수
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.65-67
    • /
    • 2001
  • Temperature and resistance of a Bi-2223 tape for fault currents up to 10 $I_{c}$ were measured in two types of samples taking into account real applications. The results indicate that the Bi-2223 tape is safe from burn-out for fault currents with a few cycles up to 10 I$_{c}$. For fault currents of over an order of magnitude higher than the nominal current, the temperature of the Bi-2223 tape depends strongly on fault durations.s.

  • PDF