• Title/Summary/Keyword: tanks

Search Result 1,340, Processing Time 0.029 seconds

Comparative Analysis of the Storm Sewer Expansion Methodology and Underground Rainwater Storage Tanks for Urban Flood Control (기존 도시의 홍수저감을 위한 우수관거 배수용량 증대 및 지하 빗물저류조 설치효과 비교 분석)

  • Lee, Ho Yeol;Seo, Gyu Tae;Lee, Taek Soon
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.6
    • /
    • pp.754-761
    • /
    • 2013
  • Urban floods are usually caused by the lack of drainage capacity. Hence, sewer capacity expansion methodology by replacing small pipes with bigger ones is primarily applied as a flood control measure. However, this approach is often unreasonable because of the costs and time involved. Thus, the installation of underground rainwater storage tanks with the two advantages of flood control and water conservation is proposed. This study compared the effectiveness of flood control by both the sewer expansion methodology and rainwater storage tanks using the Storm Water Management Model. Three cases were simulated in this study. The first case analyzed flood reduction by the storm sewer expansion methodology. The simulation results indicate that the overflow volume from manholes was reduced by 49% with this methodology. The second case analyzed flood reduction by installation of rainwater storage tanks. The simulation results indicate that the overflow volume was reduced by 62%. However, these two cases could not prevent urban floods completely. Hence, the third case analyzed the joint application of the storm sewer expansion methodology and rainwater storage tanks. In this simulation, flooding did not occur. Consequently, the results of this study clearly show that underground rainwater storage tanks are more effective for flood control than capacity expansion of storm sewer. Furthermore, the joint application of these two flood control measures is more effective than their separate application.

Resin Optimization for Manufacturing CFRP Hydrant Tanks for Fire Trucks (소방차용 CFRP 소화전 탱크제조를 위한 수지 최적화 연구)

  • Huh, Mong Young;Choi, Moon Woo;Yun, Seok Il
    • Composites Research
    • /
    • v.35 no.4
    • /
    • pp.255-260
    • /
    • 2022
  • Lightweight hydrant tanks increase the amount of water that can be carried by fire trucks, resulting in longer water spray times during the initial firefighting process, which can minimize human and property damages. In this study, the applicability of carbon-fiber-reinforced polymer (CFRP) composites as a material for lightweight hydrant tanks was investigated. In particular, the resin for manufacturing CFRP hydrant tanks must meet various requirements, such as excellent mechanical properties, formability, and dimensional stability. In order to identify a resin that satisfies these conditions, five commercially available resins, including epoxy(KFR-120V), unsaturated polyesters(G-650, HG-3689BT, LSP8020), vinyl ester(KRF-1031) were selected as candidates, and their characteristics were analyzed to investigate the suitability for manufacturing a CFRP hydrant tank. Based on the analyses, KRF-1031 exhibited the most suitable properties for hydrant tanks. Particularly, CFRP with KRF-1031 exhibited successful results for thermal stability and elution tests.

Occurrence of Culex pipiens (Diptera, Culicidae) and Effect of Vent Net Sets for Mosquito Control at Septic Tanks in South-eastern Area of the Korean Peninsula (한반도 동남부 지역 정화조 내의 빨간집모기군(群)(Culex pipiens complex) 발생과 정화조 환기통의 방충망 설치에 의한 방제효과)

  • Lee Dong-Kyu
    • Korean journal of applied entomology
    • /
    • v.45 no.1 s.142
    • /
    • pp.51-57
    • /
    • 2006
  • Culex pipiens complex larvae were found at the septic tanks in Busan and Ulsan cities located in South-eastern area of Korean peninsula. The larvae were collected in 25, 35 and 75 septic tanks out of 3,527, 622 and 1,111 septic tanks which the breeding rates were averages of 0.7%, 5.6% and 6.8% in Busan from January to May, 2003; Busan from February to March, 2004; and Ulsan from January to April, 2005, respectively. The average numbers of the mosquitoes in the tanks were 38.8, 14.9 and 13.7 larvae/dip with a 355-ml dipper. The larval densities were from 25.4 larvae/dip in January to 43.7 larvae/dip in April. 2003 which were not significantly different between them. It was the first report to find mosquito breeding at septic tink in Republic of Korea. Culex pipiens larvae were found in 6 out of 379 septic tanks at complex buildings (over $2,000m^2$ in size) in Ulsan from June to September, 2005, having an average of 1.6% for mosquito breeding rate. The mosquito larvae were collected in 8 and 530 septic tanks out of 210 and 3,729 septic tanks at large (over 300 homes) and small apartments (below 300 homes) with 3.8% and 14.2% of the average breeding rates, respectively At the septic tanks of private houses for below 50 persons, 708 out of 7,178 septic tan had Cx. pipiens larvae and pupae with 9.9% of the average breeding rate. Total average of the mosquito breeding rate was 10.9% of the investigated septic tanks of residential buildings in Ulsan. The number of mosquito larvae in the septic tanks were 15 to 75 larvae/dip. The bent net sets of septic tanks prevented from mosquito breeding to the rate of 93.1%.

REARING OF THE LARVAL PRAWN, PENAEUS JAPONICUS BATE (보리새우 Penaeus japonicus Bate의 유생사육에 관하여)

  • PYEN Choong-Kyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.2 no.1
    • /
    • pp.87-91
    • /
    • 1969
  • Experiments on the rearing of larvae of the prawn, Penaeus japonicus Bate, have been con-ducted by using a large tank A ($3.4\times1.9\times1.0m$) and two small tanks B and C ($1.45\times0.85\times1.0$). 1) Between spawning and the first zoeal stages, no significant elapsed time difference was noticed among the rearing tanks. At about $23^{\circ}C$ of water temperature nearly all of the larvae in the tanks metamorphosed into the first zoeal stage in about 36-48 hours. However the period of time which elapsed between the spawning and post-larval stage showed some differences bet-ween the tanks, i.e., 19-20 days in tank A and 15-17 days in tanks B and C, respectively 2) No difference in body length of the larvae has been observed among the three tanks. 3) The post-larva passed through several molts, one every four or five days, before reaching the young prawn about 36-40 days after spawning. 4) Throughout the zoeal stages the highest mortality was found at the time of molting between the first and second zoeal stages showing about $51.39\%$ in tank A, $50.70\%\;and\;31.91\%$ in tanks B and C, respectively. 5) Total mortality during the duration of the larval stages was around $75\%$ in all the rearing tanks.

  • PDF

A study on the safety improvement of above ground membrane LNG storage tank (상지상식 멤브레인 액화천연가스 저장탱크의 안전성 향상 방안)

  • Lee, Seung Rim;Kim, Han Sang
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.339-345
    • /
    • 2012
  • RMembrane LNG storage tanks have been recently investigated to replace full-containment LNG storage tanks because of safety and cost aspects. Quantitative Risk Analysis (QRA) and Finite Element Method (FEM) were used to evaluate safety of membrane LNG storage tanks. In this study, structural safety evaluation results via FEM analysis showed that both membrane type and full-containment type cryogenic LNG storage tanks with 140,000 $m^3$ capacity were equivalently safe in terms of strength safety and leakage safety of a storage tank system. Also, Fault Tree Analysis (FTA) was used to improve the safety of membrane LNG storage tanks and membrane LNG tanks were modified by adding three safety equipments: impact absorber structure for the low part of the membrane, the secondary barrier to diminish the thermal stress of the corner part of the outer tank, and a pump catcher in case of falling of a pump. Consequently, the safety of the modified membrane LNG storage tanks were proved to be equivalent to that of full-containment LNG storage tanks.

An Experimental Study on the Estimation of Chloride Diffusion Coefficient of LNG Storage Tanks (LNG 저장탱크 염해 확산 계수 산출을 위한 실험적 고찰)

  • Lee, Seung-Rim;Hwang, Seung-Hyun
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.119-123
    • /
    • 2012
  • Although LNG storage tanks are very delicate with chloride attack owing to its operating inshore location, specific integrity management system for chloride attack has not been studied so far. As the design warranty life time, about 25 years, has come, to prevent paying huge amount of construction cost and required resources for new alternative storage tanks and manage the life time of operating storage tanks, the basic data of chloride attack is necessary. This study intended to build up basic data for following detailed study to develop technologies for life time management of LNG storage tanks, NT Build 492 method in North Europe was used to test chloride diffusion coefficient for the newly-constructing concrete outer tank. Results of these tests lead us to the conclusion that 90 days diffusion coefficients show 46% of 28 days' due to a large quantity of fly ash mixing and much similar to estimation from concrete process table. It seems resonable to conclude that 90 days specimens are recommended estimating the chloride diffusion coefficient for LNG storage tanks to enhance the reliabilities.

Effect of Different Substrates in the Rearing Tank on Growth and Body Composition of Juvenile Sea cucumber Apostichopus japonicus (사육수조 내 사육기질이 어린 해삼의 성장 및 체조성에 미치는 영향)

  • Seo, Joo-Young;Kim, Dong-Gyu;Kim, Guen-Up;Cho, Sung-Su;Park, Heum-Gi;Lee, Sang-Min
    • Journal of Aquaculture
    • /
    • v.22 no.1
    • /
    • pp.118-121
    • /
    • 2009
  • This experiment was conducted to evaluate the effects of different substrates in rearing tank on growth and body composition of juvenile sea cucumber Apostichophus japonicus. Sea cucumber (average weight 3.6) were randomly distributed at a density of 10 juvenile per tank into nine tanks providing three different substrates including free-substrates, sand and wave-shaped plastic sheet as (shelter). Juveniles were fed with a commercial feed once in every 2 days for 8 weeks. At the end of the experiment, survival of sea cucumber was not affected by the presence of substrates (P>0.05). Weight gain and specific growth rate of sea cucumber reared in the tanks with sand were significantly higher than those of sea cucumber reared in the tanks with shelter and without substrate (P<0.05). Crude protein and crude lipid of whole body in sea cucumber reared in free-substrate tanks were significantly higher than those of juvenile reared in the tanks with other substrates (P<0.05). Higher ash content was obtained in sea cucumber reared in the tanks with sand compared to that of juvenile reared in the tanks with other substrates (P<0.05). The results of this study suggest that growth and proximate composition of whole body of sea cucumber was significantly affected by substrates. Among materials tested, sand may be a proper substrate for sea cucumber culture.

Analytical study of failure damage to 270,000-kL LNG storage tank under blast loading

  • Lee, Sang Won;Choi, Seung Jai;Kim, Jang-Ho Jay
    • Computers and Concrete
    • /
    • v.17 no.2
    • /
    • pp.201-214
    • /
    • 2016
  • The outer tank of a liquefied natural gas (LNG) storage tank is a longitudinally and meridianally pre-stressed concrete (PSC) wall structure. Because of the current trend of constructing larger LNG storage tanks, the pre-stressing forces required to increase wall strength must be significantly increased. Because of the increase in tank sizes and pre-stressing forces, an extreme loading scenario such as a bomb blast or an airplane crash needs to be investigated. Therefore, in this study, the blast resistance performance of LNG storage tanks was analyzed by conducting a blast simulation to investigate the safety of larger LNG storage tanks. Test data validation for a blast simulation of reinforced concrete panels was performed using a specific FEM code, LS-DYNA, prior to a full-scale blast simulation of the outer tank of a 270,000-kL LNG storage tank. Another objective of this study was to evaluate the safety and serviceability of an LNG storage tank with respect to varying amounts of explosive charge. The results of this study can be used as basic data for the design and safety evaluation of PSC LNG storage tanks.

Mathematical Model Simulations Assessing the Effects of Temperature on Residual Chlorine Concentrations in Water Storage Tanks (온도 변화에 따른 수돗물 저장 저수조 내 잔류염소에 관한 수학적 모형 시뮬레이션)

  • Noh, Yoorae;Park, Joonhong
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.2
    • /
    • pp.187-196
    • /
    • 2017
  • To ensure hygienic safety of drinking water in a water storage tank, the concentrations of residual chlorine should be above a certain regulation level. In this study, we conducted model simulations to investigate the effects of temperature on residual chlorine in water storage tank conditions typically used in Seoul. For this, values of model parameters (decomposition rate constant, sorption coefficient, and evaporation mass transfer coefficient) were experimentally determined from laboratory experiments. The model simulations under continuous flow conditions showed that the residual chlorine concentrations were satisfied the water quality standard level (0.1 mg/L) at all the temperature conditions ($5^{\circ}C$, $10^{\circ}C$, $15^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$). Meanwhile, when the tanks had a no flow condition (i.e., no tap-water influent due to a sudden shut-down), the concentrations became lower than the regulatory level after certain periods. The findings from this modeling works simulating Seoul's water storage tanks suggested disappearance rate of residual chlorine could be reduced through the tanks design optimization with maintenance of low water temperature, minimization of air flow and volume, suppression of dispersion and the use of wall materials with low sorption ability.

A Comparative Study on the Earthquake Resistant Design Criteria for Cylindrical, Liquid-Storage Tanks (원통형 액체저장탱크 내진설계기준의 비교연구)

  • 국승규
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.2
    • /
    • pp.69-75
    • /
    • 1998
  • Because the collapse of liquid-storage tank structures under earthquakes brings out substantially more damages by indirect effects(continuous losses of economy and environmental disruption due to the spillage of toxic contents or pollutants) than direct economic losses of tanks and contents, it is an urgent matter to provide earthquake resistant design criteria in order to minimize such direct/indirect damages. In this paper, as fundamental works to prepare earthquake resistant design criteria for cylindrical liquid-storage tanks, analysis methods given in the Recommendations of New Zealand and Austria are reviewed and the applicabilities and problems of the two methods are set forth by comparison of the analysis results with a numerical example.

  • PDF