• 제목/요약/키워드: tanks

검색결과 1,340건 처리시간 0.032초

석유류 저장 탱크에서의 액면 및 유츌화재에 대한 복사열의 실험적 연구 (Experimental Study of Radiation Heat Flux for the Pool and Spill Fire in Petroleum Storage Tanks)

  • 김홍;박형주
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.88-93
    • /
    • 2004
  • This experimental study was carried out to evaluate effect of the radiation heat flux for the pool and spill fire in petroleum storage tanks, which were made form steel. Each of them had the capacity of 250, 2500 and 25000 liter, respectively. The effects of the radiation heat flux are as follows; 1) The intensity of radiation heat flux from a flame decreased exponentially with increasing distance from outside wall of tanks, and increased significantly with surface area of tank and dyke. 2) In the case of 25000L tank, the radiation heat flux was about max. 98.9kW/$m^2$ in 1m from wall of tank. 3) The distance, that was able to ignite wood or plastics by radiation heat flux of approximately 12.5kW/$m^2$, was about 3.14m from wall of 25000L tank.

Fluid effect on the modal characteristics of a square tank

  • Jhung, Myung Jo;Kang, Sung-Sik
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1117-1131
    • /
    • 2019
  • Tanks are used extensively in many engineering areas for spent fuel pool structures at nuclear power plants or for water storage tanks in bulk carriers. To ensure the structural integrity of such tanks when under dynamic loads, modal characteristics such as natural frequencies, participation factors and mode shapes should be known. Investigated in this study are the modal characteristics of a square tank by the finite element method. This approach can be used with subsequent dynamic analyses such as a response spectrum analysis or a harmonic analysis. Finite element models are prepared to determine the natural frequencies and mode shapes, which are easy to find the modal characteristics of a fluid-filled square tank. The effects of the fluid contained in the tank and the boundary conditions at top and bottom ends on the modal characteristics are assessed by several finite element analyses.

강재 액체저장탱크의 내진설계를 위한 설계기준 분석 (Comparison of Design Standards for Seismic Design of Steel Liquid Storage Tanks)

  • 배두병;박장호;오창국
    • 한국강구조학회 논문집
    • /
    • 제28권3호
    • /
    • pp.195-202
    • /
    • 2016
  • 본 논문은 강재 액체저장탱크의 내진설계를 위하여 이용되고 있는 Eurocode 8, API 650, NZSEE 등의 해외 설계기준들의 설계방법들을 비교, 분석함으로써, 강재 액체저장탱크의 내진설계를 위한 국내 설계기준을 수립하기 위하여 필요한 주요 사항들에 대한 자료를 제공하고자 하였다. 각 설계기준에서는 강재 액체저장탱크의 내진설계를 위하여 충격성분과 대류성분을 이용한 단순화된 형태의 역학적 모델을 제시하고 있다. Eurocode 8, API 650 등의 설계기준에서는 두 개의 질량을 가지는 역학적 모델을, NZSEE에서는 세 개의 질량을 가지는 역학적 모델을 사용하고 있다. 또한 Eurocode 8, NZSEE은 강도설계법을 사용하고 있으며, API 650은 허용응력설계법을 사용하고 있어 하중 등에 대한 직접적인 비교는 적절하지 않아 역학적 모델에 대한 주요 인자들을 위주로 비교, 검토하였다. 역학적 모델은 설계기준에 따라 차이는 있으나 충격성분 및 대류성분의 질량 및 진동수 등은 유사하게 나타났다. 강재 액체저장탱크에 대한 국내 내진설계기준은 허용응력설계법보다는 하중저항계수설계법을 사용하고, 국내의 실정에 맞는 하중 및 저항 특성을 고려하여 강재 액체저장탱크의 신뢰도 수준을 일정하게 유지하는 것이 필요할 것으로 판단된다.

An Approach to Double Hoist Scheduling in the Chemical Processes

  • Lim, Joon-Mook;Hwang, Hark
    • 한국경영과학회지
    • /
    • 제18권2호
    • /
    • pp.131-145
    • /
    • 1993
  • This paper deals with scheduling problem of the chemical process system where aircraft parts go through a given sequence of tanks filled with chemical solutions. The system has two hoists which move carriers holding the parts between tanks. A mixed integer programming model is developed from which a maximum throughput schedule can be found for the hoist movements. To show the validity of the model, a real world problem is solved and the results are compared with those with an existing approach.

  • PDF

전차 시뮬레이션 모델 개발 (Development of Tank Simulation Model)

  • 최상영;김의환
    • 한국국방경영분석학회지
    • /
    • 제28권2호
    • /
    • pp.125-136
    • /
    • 2002
  • This paper is aimed to develop Tank Simulation Model. The model simulates Tank-to-Tank engagement and Tank-to-Helicopter engagement by considering Korean battlefield environment. The simulated entities are command tanks, fight tanks, scout helicopters, attack helicopters, anti-tank guided missiles, and decoys. In this paper, we explain the model operational concept, model development and finally we will show some illustrative examples.

Nonlinear sloshing in rectangular tanks under forced excitation

  • Zhao, Dongya;Hu, Zhiqiang;Chen, Gang;Lim, Serena;Wang, Shuqi
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제10권5호
    • /
    • pp.545-565
    • /
    • 2018
  • A numerical code is developed based on potential flow theory to investigate nonlinear sloshing in rectangular Liquefied Natural Gas (LNG) tanks under forced excitation. Using this code, internal free-surface elevation and sloshing loads on liquid tanks can be obtained both in time domain and frequency domain. In the mathematical model, acceleration potential is solved in the calculation of pressure on tanks and the artificial damping model is adopted to account for energy dissipation during sloshing. The Boundary Element Method (BEM) is used to solve boundary value problems of both velocity potential and acceleration potential. Numerical calculation results are compared with published results to determine the efficiency and accuracy of the numerical code. Sloshing properties in partially filled rectangular and membrane tank under translational and rotational excitations are investigated. It is found that sloshing under horizontal and rotational excitations share similar properties. The first resonant mode and excitation frequency are the dominant response frequencies. Resonant sloshing will be excited when vertical excitation lies in the instability region. For liquid tank under rotational excitation, sloshing responses including amplitude and phase are sensitive to the location of the center of rotation. Moreover, experimental tests were conducted to analyze viscous effects on sloshing and to validate the feasibility of artificial damping models. The results show that the artificial damping model with modifying wall boundary conditions has better applicability in simulating sloshing under different fill levels and excitations.

필라멘트 와인딩된 복합재료 압력탱크에 삽입된 광섬유 브래그 격자 센서의 생존율 향상 (The Improvement of Survivability of Fiber Brags Grating Sensors Embedded into Filament Wound Pressure Tanks)

  • 강동훈;박상욱;박상오;김천곤
    • Composites Research
    • /
    • 제18권5호
    • /
    • pp.1-8
    • /
    • 2005
  • 여러 복합재료 제작기법 중에서 필라멘트 와인딩 제작 기법은 압력탱크, 파이프 등과 같은 실린더 형태의 축대칭 구조물의 제작에 가장 효율적인 방법이다. 또한, 필라멘트 와인딩으로 제작된 복합재료 압력탱크는 운용 중 큰 내압을 받게 되며 복잡한 손상 메커니즘과 파손 모드를 가지고 있다. 그러므로, 필라멘트 와인딩으로 제작된 복합재료 압력탱크는 탱크의 제작 과정과 제작 후 전 과정 동안의 탱크에 대한 건전성 모니터링이 필요하며 이를 위해 탱크의 제작 시부터 탱크 내부의 여러 지점에 센서가 삽입 적용되어야 한다. 여러 센서 중에서 광섬유 센서는 복합재료 내부에 삽입이용이한 센서이며 특히, 광섬유 브래그 격자 센서(fiber Bragg grating Sensors, FBG센서)는 다중화(multiplexing)가 용이한 것을 큰 장점으로 가장 많이 채택되고 있다. 하지만, FBG 센서를 필라멘트 와인딩된 복합재료 압력탱크에 성공적으로 삽입 적용하기 위해서는 극심한 탱크의 삽입 환경에 대한 센서의 삽입 기법의 개발이 선행되어야 한다. 본 연구에서는 필라멘트 와인딩된 복합재료 압력탱크의 제작 시 FBG 센서를 탱크 내부에 다중화하여 삽입적용하기 위한 기법에 대하여 연구하였다.

지역난방용 축열조의 단열재 손상과 외각부식 개선방안 (Prevention of Insulation Damage Layer and Shell Corrosion in Thermal Storage Tanks for District Heating)

  • 방용운;유호선
    • 플랜트 저널
    • /
    • 제10권4호
    • /
    • pp.35-41
    • /
    • 2014
  • 축열조는 집단에너지를 공급하는 지역의 고도와 열부하에 따라 높이와 용량이 결정된다. 이는 축열조의 수두를 이용하여 열배관망에 압력을 가하고 배관망내의 비등을 방지하며 온도변화에 따라 체적이 팽창하면 이를 흡수하고 수축 시에는 부족한 중온수를 배관망에 공급하는 기능을 해야 하기 때문이다. 또한, 축열조의 역할은 주로 열수요량의 변화가 심한 계절별 주간 야간 시간대에 적절한 용량을 갖추고 잉여 열량을 저장한 후 필요한 시간대에 지역난방 열원으로 이용하면 열생산 설비의 운전 조건에 영향을 받지 않으면서 독자적으로 지역난방 열수요를 공급할 수 있는 장점이 있다. 본 연구는 지역난방에 건설되어 운영 중인 축열조 27기 중 폴리우레탄 폼의 단열 재료로 시공된 18기의 축열조에 대하여 단열재의 재질과 축열조의 운전방법에 따른 단열재의 손상원인에 대한 고찰과 단열재 손상이 축열조 부식에 어떠한 영향을 미치는지 고찰하였다.

  • PDF

저수조의 효율적 관리를 위한 수질실태에 관한 연구 (A Study on the Water Quality for Efficient Management in the Water Tanks)

  • 박현건;류승철;전수임
    • 한국환경과학회지
    • /
    • 제18권12호
    • /
    • pp.1339-1347
    • /
    • 2009
  • This study tried to investigate and analyze the actual state such as the regional, classified, and material characteristics of the water quality in order to research the several factors by which the filtrated water of the total 250 cases can be polluted in the water tank. The 215 points (86%) clean the water tanks twice a year regularly and J-city has done the best job of cleaning the water tanks. The fifty points (20%) of the total 250 investigation points examine the water quality of the water tanks every year, however, the 175 investigation points (70%) do not execute the inspection of water quality. In the case of the regional characteristics in the water quality, the 23 points (46%) in H-county, the 17 points (34%) in S-county, and the 16 points (32%) in G-city are incongruent in the standard, and the incongruity ratio of the water quality in J-city is the lowest. The result of the classified incongruity shows that total coliforms were found at the 61 investigation points, mesophilic bacteria were found at the 27 points, and turbidity was found at the 12 points. In the case of the material incongruity, concrete was found at the 63 investigation points as the most distinguished factor, and FRP (fiberglass reinforced plastic) at the 23 points, SMC (sheet molding compound) at the 12 points, and stainless steel was found at the 2 points.