• Title/Summary/Keyword: tank diameter

Search Result 235, Processing Time 0.028 seconds

Protein Removal by a Foam Fractionator in Simulated Seawater Aquaculture System

  • Peng, Lei;Oh, Sung-Yong;Jo, Jae-Yoon
    • Ocean and Polar Research
    • /
    • 제25권3호
    • /
    • pp.269-275
    • /
    • 2003
  • Effects of different operating factors including superficial air velocity (SAV), hydraulic residence time (HRT), protein concentration, and foam overflow height on protein removal by a foam fractionator in simulated seawater aquaculture system were investigated. This experiment was conducted on batch and consecutive modes at different combinations of the affecting factors. The foam fractionator had a diameter of 20cm and a height of 120cm and the experiment was conducted with synthetic wastewater. In 5 consecutive trials, protein concentrations in culture tank water decreased faster when the foam fractionator was operated at higher SAVs and lower HRTs. In batch trials, protein removal rates increased with an increase in SAV but decreased with an increase in URT. Higher protein concentrations in the bulk solution resulted in higher protein removal rates. Protein concentrations in the collected foam condensates increased but the foam overflow rates decreased with the increase of foam overflow heights. The results of this experiment indicate that foam fractionation would be an effective way for protein removal in seawater aquaculture systems and the performance of the foam fractionator depends largely on the operating parameters, especially SAV.

해산 자치어의 먹이생물로써 섬모충 Euplotes sp.의 평가 (Evaluation of Ciliate Euplotes sp. as a Live Food for Marine Fish Larvae)

  • 유진형;허성범
    • 한국수산과학회지
    • /
    • 제35권5호
    • /
    • pp.542-544
    • /
    • 2002
  • This study was carried out to evaluate the ciliates Euplotes sp. as a live food for marine fish larvae. The ciliates and the rotifers Brachionus plicatilis, which were cultured with the baker's yeast Saccharomyces cerevisiae and the $\omega$-yeast emulsified with cuttle fish liver oil, were supplied to the larvae of flounder Paralichthys olivaceus and grouper Epinephelus akaara. Considering the size difference between the ciliates 68 $\cdot$ 7 $\mu$n and the rotifers 160 $\cdot$ 20 $\mu$n, the rotifers and ciliates were supplied to the larvae tank with the density of 2 inds./mL and 20 inds./mL, respectively. The survival rate and growth in length of the flounder larvae fed on rotifer were significantly higher than those on Euplotes sp.. In grouper larvae which have a small mouth diameter, even the survival rate of the larvae fed on the ciliates was better than that on the rotifers, it was very low less than $20\%$. Therefore, Euplotes sp. seem to be incongruent as a live food for marine fish larvae.

$PE-N_2O$ 추진제를 이용한 소형 하이브리드 로켓 모터 개발 (Development of Small-scale Hybrid Rocket Motor using $PE-N_2O$ Propellants)

  • 조승현;박구정;조정태;김종찬;윤창진;김진곤;문희장
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.370-373
    • /
    • 2007
  • 산화제 탱크와 연소실이 결합된 기존의 구조에서 산화제 탱크가 연소실에서 분리 가능한 구조의 하이브리드 모터를 개발하였다. 초기 개발된 모터는 설계 추력의 30% 정도에 불과한 성능을 보였으며, 이는 산화제 유량이 원활히 공급되지 못했기 때문인 것으로 판단되었다. 이러한 판단 하에, 경험적으로 인젝터 오리피스 면적을 증가시켜가며, 산화제 유량이 설계 유량에 근접하도록 개선하였다. 개선된 모터는 설계치의 약 60% 정도인 18kgf까지 성능이 향상되었으며, 이로부터 개발된 모터가 사운딩 로켓 모터의 임무 수행에 적절한 추력 대 중량비의 범위 내에 있음을 확인하였다.

  • PDF

Thermal and Absorbing Performance in a Vertical Absorber

  • Cho, Keum-Nam;Kim, Jung-Kuk
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.51-59
    • /
    • 2000
  • The purpose of the present study is to investigate the absorbing characteristics in a vertical falling film type absorber using LiBr-H$H_2O$ solution as working fluids with the concentration of 60 wt%. The experimental apparatus consists of an absorber with the diameter of 17.2 mm and the length of 1150 mm, a generator, an evaporator (condenser), a weak solution tank and a sampling trap device and so on. The parameters were the solution temperatures of 45 and 50$^{\circ}$C, coolant temperatures of 30 and 35$^{\circ}$C, and the film Reynolds numbers from 50 to 150. The pressure drop in the absorber increased as the solution and coolant temperatures decreased. The pressure drop in the absorber increased up to the film Reynolds number of 90, however, decreased at the film Reynolds number above 90. The maximum absorption mass flux was observed at the film Reynolds number of 90. Absorption mass fluxes increased as the coolant temperature decreased. Accordingly, absorption mass fluxes and heat transfer coefficients under the subcooled condition increased more than those under the superheated condition. It is claimed that heat transfer coefficients are deeply affected by the solution temperature more than the coolant temperature within the experimental range.

  • PDF

하나로 원형 조사공의 안내관 유동특성 (Flow Characteristics for Guide Tube of Circular Irradiation Hole in HANARO)

  • 박용철;우종섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1835-1840
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth, open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. The HANARO is composed of inlet plenum, grid plate, core channel with flow tubes and chimney. The reactor core channel is located at about twelve meters (12 m) depth of the reactor pool and cooled by the upward flow that the coolant enters the lower inlet of the plenum,. rises up through the grid plate and the core channel and comes out from the outlet of chimney. A guide tube is extended from the reactor core to the top of the reactor chimney for easily un/loading a target under the reactor normal operation. But active coolant through the core can be quickly raised up to the top of the chimney through the guide tube by a jet flow. This paper describes an analytical analysis that is the study of the flow behavior through the guide tube under reactor normal operation and unloading the target. As results, it was conformed through the analysis results that the guide jet is suppressed under the top of the chimney after modifying the orifice diameter of 37.5 mm to 31 mm.

  • PDF

이산화탄소 하이드레이트 슬러리의 생성 및 수송기술개발 (Development of Formation and Transportation Techniques for CO2-Hydrate Slurry)

  • ;윤린
    • 설비공학논문집
    • /
    • 제29권7호
    • /
    • pp.341-349
    • /
    • 2017
  • Formation and transportation of $CO_2$-hydrate slurry was conducted by circulating saturated water with $CO_2$ through a double-tube type heat exchanger which was cooled down by brine. The inner diameter and circulation length of the heat exchanger were 1 inch and 20 m, respectively. Water in tank was supersaturated by injected $CO_2$ and the operation pressure was maintained at 3,000 to 4,000 kPa with fluid-temperature of less than $9^{\circ}C$. $CO_2$ hydrate mass fraction was calculated based on density of $CO_2$-hydrate slurry mixture. Results showed that the $CO_2$-hydrate slurry could be circulated without blockage for 1 hr. Circulation status of the $CO_2$-hydrate slurry was also visualized.

수직형 흡수기내 열 및 물질 전달 특성 (Heat and mass transfer characteristics in a vertical absorber)

  • 서정훈;조금남;최기봉
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.835-845
    • /
    • 1999
  • The objective of the present study was to investigate heat and mass transfer characteristics in a vertical falling film type absorber using LiBr-$H_2O$ solution with 6owt%. The experimental apparatus consisted of an absorber with inner diameter of 17.2 mm and length of 1150mm, a generator, an evaporator/condenser, a solution tank, a sampling trap etc. The parameters were solution temperature of 45 and $50^{\circ}C$, coolant temperature of 30 and $35^{\circ}C$, and film Reynolds numbers from 50 to 150. Pressure drop in the absorber increased as solution and coolant temperatures decreased. Pressure drop in the absorber increased up to the film Reynolds number of 90, and then decreased at the further increase of the Reynolds number above 90. The maximum absorption mass flux observed at the film Reynolds number of 90. Absorption mass flukes increased as coolant temperature decreased. Absorption mass fluxes and heat transfer coefficients under subcooled condition were larger than those under superheated condition. Heat transfer coefficients were affected by solution temperature more than coolant temperature. The maximum absorption effectiveness under the subcooled condition was 23% for coolant temperature of $30^{\circ}C$ and 31% for coolant temperature of $35^{\circ}C$ under the present experimental conditions.

  • PDF

미세기포를 이용한 오염 호소수의 정화에 관한 연구 (Study on the Treatment of Contaminated Lake Water Using Micro Air Bubbles)

  • 김준영;박창원;이종경;장인성
    • 한국환경과학회지
    • /
    • 제16권6호
    • /
    • pp.699-706
    • /
    • 2007
  • Many lakes or irrigative reservoirs in Korea are rapidly contaminated due to the ever increasing pollutants. Although lots of treatment processes have been recommended and practiced, economical and technical improvement is currently needed. In this study, contaminated irrigation reservoir was treated using the proposed process which is consisted of fine air bubbles, coagulation and flotation. Fine bubbles, approximate diameter of 3 to $10{\mu}m$, were generated using cavitation in the pressurized tank and polyaluminum chloride was used as coagulants. This fine bubbles, coagulation and flotation effectively controlled the low density algae, for example, Chlorophyll-a was removed more than 97 %. Removal efficiency of COD, SS, T-N and T-P were 80.7%, 94.3%, 64.1 % and 92.4%, respectively. Pollutants released from the sediments was removed more than 80% of organics and 60-70 % of nutrients. Consequently, fine bubbles coagulation and flotation process could be effectively used as an alternative treatment method for the purpose of control of lake water quality.

수적을 이용한 순수확산화염의 소화에 관한 실험적 연구 (An Experimental Study of Extinguishiment of Purely Buoyant Diffusion Flame Using Water Drops)

  • 장용재;김명배;김진국
    • 연구논문집
    • /
    • 통권24호
    • /
    • pp.41-48
    • /
    • 1994
  • This experimental study deals with the extinguishiment characteristics of an oil pool flame using the water spray. The water through the six different atomizers is ejected over the freely burning pool flame in the quiescent surrounding air. Injection direction is vertical to the surface of oil in a small tank with a diameter of 100mm and a height of 10mm. In order to estimate quantitatively the extinction, the burning rate as well as the effective water flux are measured. The effective water flux is the amount of the water which reach the pool from the nozzle. The burning rate with the water spray increases until the injection pressure increases to reach some value, which gives the maximum burning rate, while the effective water flux without the flame decreases or does not change according to increasing of the injection pressure. This maximum burning rate is greater than 2.5 times of burning rate of the fire without the water spray. As a matter of the extinguishiment, it is found that the water drops of which size is too small can not extinguish the fire because too small drops does not reach the fuel surface.

  • PDF

Prediction and improvement of the solid particles transfer rate for the bulk handing system design of offshore drilling vessels

  • Ryu, Mincheol;Jeon, Dong Soo;Kim, Yooil
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제7권6호
    • /
    • pp.964-978
    • /
    • 2015
  • Numerous experiments with a scaled pilot facility were carried out to compare the relative bulk transfer performance of three special devices for applications to drilling systems. The pipe diameter for bulk transportation was 3 in., which corresponds to around half of the actual system dimensions. Two different pressures, 3 and 4 bar, were considered to check the relative performance under different pressure conditions at a bulk storage tank. And to make a practical estimation method of the bulk transfer rate at the early design stages of the bulk handling system, a series of experiments were conducted for real scaled bulk handing systems of two drilling vessels. The pressure drops at each pipe element as well as the bulk transfer rates were measured under different operating conditions. Using the measured results, the friction factor for each pipe element was calculated and a procedure for transfer rate estimation was developed. Compared to the measured transfer rate results for other drilling vessels, the estimated transfer rates were within a maximum 15% error bound.