Initial Characteristics of Generator Stator Insulations (발전기 고정자 권선 절연재료의 초기특성)

  • Lee, Young-Jun;Kim, Hee-Dong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2110-2113
    • /
    • 1999
  • This paper describes the initial characteristics of turbine generators at the Taean thermal power plant #4 and Wolsong nuclear power plant #2. The turbine generators had been in service for two years. The insulation diagnostic tests included measurements of insulation resistance, polarization index, ac current, dissipation factor($tan{\delta}$) and partial discharges (PD). The values of ac current and tan a were measured by Schering bridge. PD measurements were conducted using digital PD detector. The variation of $tan{\delta}$ and PD was confirmed in two generator stator insulations.

  • PDF

The Dielectric Analysis of Insulators for Home Appliances (가전설비용 절연재의 유전열 분석)

  • Jung, Jin-Soo;Jung, Jong-Wook;Yi, Gun-Ho;Bae, Seok-Myung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.206-207
    • /
    • 2006
  • This paper describes the dielectric analysis of several insulators for home appliances. The dielectric characteristics of ABS(acrylonitrile butadiene styrene) were tested in relative permittivity, dielectric loss($tan{\delta}$) and specific resistance and compared with those of the other 4 insulators of PE(polyethylene) series. As a result, the relative permittivity of only the ABS slightly decreased with temperature. In the case of the tan6, the ABS showed higher dielectric loss than the other insulators but more excellent thermal performance. In addition, its changing pattern in specific resistance was very similar to that in $tan{\delta}$.

  • PDF

Electrical Properties of Improved Elastomer Epoxy Resin (탄성형 에폭시의 전기적 특성평가)

  • Park, S.H.;Park, J.Y.;Lee, K.W.;Kang, S.H.;Lee, G.W.;Park, D.H.;Lim, K.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.53-56
    • /
    • 2003
  • In this paper we investigated electrical properties for epoxy resin with improved mechanical property, elastomer epoxy. Investigated electrical properties are permittivity, tan $\delta$ and breakdown voltage strength(BDV). Permittivity and tan $\delta$ have dependancy on additive Quantity in general purpose epoxy resin. In particularly, those have very high values at low frequency and high temperature according to increasing component of elastomer. In case of BDV test, those materials have only a little difference due to increasing elastomer components. But in case of high quantities of elastomer, BDV has a difference. These results are represented that elastomer epoxy resin despite superior mechanical property needs many carefully thought as application electrical insulation.

  • PDF

Analysis of Diagnosis and Very Low Frequency Experiment to Detect of Fault on 22.9kV Class Cable (22.9kV급 케이블 결함 검출을 위한 초저주파 실험 및 현장 진단 분석)

  • Kim, Young-Seok;Kim, Taek-Hee;Kim, Chong-Min;Shong, Kil-Mok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1780-1785
    • /
    • 2016
  • This paper presents few case studies of state diagnosis of XLPE cables using very low frequency techniques. The power cables of 22.9kV which have installation fault were assessed using VLF technique in addition to other techniques like insulation resistance and DC voltage withstand test. From the experimental results, The dielectric loss($tan{\delta}$) values of degradation of the cable(joint, knife, needle) at $U_0$ were 5.839, 5.526 and 6.251, respectively and all values were "further study advised". VLF PD measurement was also found defective portion. These method was effective in defect to fault in the degradation of the cable. However, the breakdown did not occur in the degradation of the cable because of properties of XLPE insulation. Few case studies of using VLF $tan{\delta}$ diagnosis for fault are measured and analyzed. The $tan{\delta}$ values at $U_0$ were "further study advised" or "action required".

A Study on the Deterioration Diagnosis Device of Pole Transformer using FFT (FFT를 이용한 주상 변압기의 열화 진단 장치에 관한 연구)

  • 윤용한;김영춘;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.97-106
    • /
    • 2000
  • This paper proposes on-line based a deterioration diagnosis device for diagnosis pole transformers using tan$\delta$ and FFT(fast Fourier transform). We measured tan$\delta$ and temperature to diagnose pole transformer insulating oil, diagnostic results are processed by FFT. For measuring convenience, we use R/F(radio frequency) wireless data communication module operating by secondary voltage of pole transformer. We have voltage variation test and oil temperature variation test to prove usability of proposed diagnosis device. The result of this paper shows that the proposed device can be used as deterioration diagnosis device of pole transformers.

  • PDF

The Dielectric Properties of OPP film due to Irradiation Aging (방사선 열화에 따른 이축연신 폴리프로필렌 필름의 유전특성)

  • 오세원;조경순;김용주;김왕곤;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1993.11a
    • /
    • pp.80-84
    • /
    • 1993
  • In this research, we studied the variation of the dielectric loss absorption of the dielectric loss absorption of the sample according with the change to $\^$60/Co-${\gamma}$-ray irradiation dose of the influence of temperature and applied voltage. In order to investigate the effect of irradiation oriented polypropylene film, we have observed dissipation factor within the temperature range of 30∼130 [$^{\circ}C$] and voltage range of 100∼250$^{\circ}C$ [V]. As for the dependency of temperature by dissipation factor, the ${\alpha}$-peak which appears at high temperature increases accordingly to the increasement of irradiation dose which is contributed by the crystal region and moves towards the high temperature. The ${\beta}$-peak which appears at low temperature is origined from dipoles and molecular motions in the amorphous region. As for the dependency of voltage by tan$\delta$, at low temperature the peak of the tan$\delta$, at low temperature the peak of the tan$\delta$ shifts accordingly to the increasement of irradiation dose towards the high temperature region.

  • PDF

Electrical Characteristics of Insulation Paper for Distribution Transformers (배전변압기용 절연지의 전기적 특성)

  • Jung, J.W.;Song, I.K.;Lee, B.S.;Han, J.H.;Kweon, D.J.;Kim, C.Y.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.1-5
    • /
    • 2001
  • This paper describes the electrical characteristics of Nomex paper employed as an insulating material of distribution transformers. The relative permittivities(dielectric constants) and $tan{\delta}$(dielectric dissipation factors) were measured as a dielectric characteristic and the partial discharge inception voltages(PDIVs) and breakdown voltages were also measured as an electrical strength characteristic of Nomex paper. As a result, the permittivity and $tan{\delta}$ of Nomex paper showed temperature and frequency dependency. Especially, the permittivity of 0.18mm Nomex paper was 2.4 according to the ASTM condition. And the PDIVs and breakdown voltages were, almost linearly increased with the thickness of Nomex paper and its electrical strength was better than conventional kraft paper.

  • PDF

Cure Behavior, Compression Set and Dynamic Mechanical Properties of EPDM/NBR Blend Vulcanizates (EPDM/NBR 블렌드 가황체의 가교 거동, 영구 압축 줄음율 및 동적 기계적 성질)

  • 박찬영
    • Polymer(Korea)
    • /
    • v.25 no.2
    • /
    • pp.233-239
    • /
    • 2001
  • The ethylene propylene diene terpolymer (EPDM) blends with acrylonitrile butadiene rubber (NBR) were prepared by mechanical mixing method. Mooney viscosity, cure behaviors, compression set and dynamic mechanical properties were subsequently examined. Dynamic characteristics of the entire blends determined from a Rheovibron generally showed two glass transitions (T'$_{g}$s), -43$^{\circ}C$ and -4$^{\circ}C$ for NBR and EPDM, respectively. The tan $\delta$ peak monotonically shifted toward the higher temperature with increasing NBR content. It was also found that the optimum cure time was significantly decreased with loading of NBR.

  • PDF

Effects of Ceramics on Dielectric Properties of Polystyrene / Ceramics Composites at Microwave Frequencies

  • Jeon, Chang-Jun;Kim, Eung-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.3
    • /
    • pp.257-262
    • /
    • 2011
  • Dependencies of dielectric properties on $MgTa_2O_6$, $MgNb_2O_6$, and $MgWO_4$ (Mg-based ceramics) fillers of the polystyrene (PS) matrix composites were investigated as a function of frequency. With increasing frequency from 1 GHz to 7.3 GHz, the dielectric constant (K) of the composites was not changed significantly, while the dielectric loss (tan${\delta}$) of the composites was slightly decreased. The K, tan${\delta}$, and temperature coefficient of resonant frequency (TCF) of the composites were dependent on the type and amount of ceramics at 11 GHz. Also, several theoretical models have been employed to predict the effective dielectric constant of the composites and the results were compared with experimental data. Typically, a K value of 6.67, tan${\delta}$ of $0.56{\times}10^{-3}$, and TCF of -4.99 $ppm/^{\circ}C$ were obtained for the PS composites with 0.4 volume fraction of $MgNb_2O_6$ at 11 GHz.

Effects of Environmental Factors such as Temperature and Ozone Concentration on the Properties of BR/Crystalline Rubber Blend (BR고무/결정성고무 블렌드의 물성에 미치는 온도 및 오존농도 등의 환경인자의 영향)

  • Park, Chan-Young;Lee, Won-Kee;Min, Seong-Kee
    • Elastomers and Composites
    • /
    • v.45 no.1
    • /
    • pp.44-50
    • /
    • 2010
  • The butadiene rubber(BR) blends with chloroprene rubber(CR) were prepared by mechanical mixing method. Cure characteristics, mechanical properties, ozone resistance properties and dynamic mechanical properties were subsequently examined. The properties of ozone resistance of pure BR was significantly improved through blending with 50 wt% CR. Dynamic characteristics determined from a Rheovibron generally showed two glass transition($T_g$) for the entire blends, $tan{\delta}$ peak monotonically shifted toward the higher temperature with the increasing content of CR. Optimum cure time of compound was significantly lengthened with loading of CR.