• Title/Summary/Keyword: tan$\delta$

검색결과 521건 처리시간 0.028초

고압전동기 고정자 권선에서 비파괴와 파괴시험의 비교 (Comparison of Nondestructive and Destructive Tests in High Voltage Motor Stator Windings)

  • 주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2097-2100
    • /
    • 1999
  • Nondestructive and destructive tests were performed the stator windings of three high voltage motors prior to the rewind. Nondestructive tests included ac current increase rate($\Delta$I), dissipation factor(${\Delta}tan{\delta}$), and maximum partial discharge(Qm) The destructive tests included breakdown at three phases with ac voltage. Flashover occurred between the connected winding of endwinding and the stator flame. In two cases creeping discharge occurred between the individual phase windings and the wedges In the stator ends. The results of destructive tests could rarely be determined the breakdown voltage.

  • PDF

아크릴로니트릴이 극성기로 도입된 유화중합 SBR/실리카 컴파운드의 기계적 물성 (Mechanical Properties of Acrylonitrile Functionalized Emulsion SBR/silica Compounds)

  • 김동원;서병호;김희정;백현종;강종원;김원호
    • Elastomers and Composites
    • /
    • 제47권1호
    • /
    • pp.54-64
    • /
    • 2012
  • 본 연구에서는 polar 한 silica 와 non-polar 한 고무사이의 친화력을 증대시키기 위하여 SBR 분자 주쇄에 acrylonitrile 을 도입시킨 acrylonitirle functionalized emulsion SBR 의 물성에 관하여 연구하였다. Acrylonitrile의 nitrile group 은 silica 표면의 silanol group 과 H-bond 를 형성할 수 있음으로 polar 한 silica 표면에 흡착되는 가교촉진제를 줄이고 가황반응을 촉진시키는 것으로 판단된다. SBR 및 AN-SBR 에 PEG 를 적용한 컴파운드의 경우 PEG 와 silica 표면의 silanol group 과의 상용성이 높아 가교촉진제가 polar 한 silica 표면에 흡착됨을 줄여 가교시간이 단축된 것으로 판단된다. 기계적 물성에서 AN-SBR 컴파운드는 SBR 1721 컴파운드 대비 100%, 300%에서 높은 모듈러스 값을 나타내었다. 이러한 결과는 AN-SBR 의 높은 분자량 및 nitrile group 의 도입에 따른 가교도의 상승에 의한 결과로 판단된다. 동적점탄특성 결과에서 AN-SBR 컴파운드는 SBR 1721 컴파운드 대비 $60^{\circ}C$ 에서 낮은 tan ${\delta}$ 값을 나타내었으며, 이는 nitrile group 과 silica 사이의 친화력에 따른 filler-rubber interaction의 향상에 의해 반복변형에 의한 energy dissipation 이 낮은 것으로 판단된다.

EEA/Acetylene Black 복합체의 유전특성과 점탄성에 관한 연구 (A Study on the Dielectric Properties and Viscoelasticity of EEA/Acetylene Black Composites)

  • 이경용;양종석;최용성;남종철;성백룡;박동하;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.138-139
    • /
    • 2005
  • To measure electrical properties and viscoelasticity of semiconducting materials in power cable, we have investigated dielectric properties and modulus of EEA/acetylene black composite showed by changing the content of acetylene black. The permittivity from experimental result was increased, while tan6 was decreased by an increment of the content of acetylene black. The modulus of specimens was increased according to a increment of a acetylene black content. And modulus was rapidly decreased at the glass transition temperature. The tan$\delta$ of specimens was decreased according to a increment of a acetylene black content.

  • PDF

열 열화에 의한 폴리에틸렌 테레프탈레이트 필름의 전기 특성에 관한 연구 (A Study on Electricity Properties of Polyethylene Terephthalate Film due to Thermally Degradation)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제30권11호
    • /
    • pp.693-698
    • /
    • 2017
  • In this study, the thermal degradation properties of polyethylene terephthalate film has been examined by the capacitance, Tan ${\delta}$, thermography, FTIR, and SEM results at temperatures of $90{\sim}170^{\circ}C$ and frequencies of 0.3~3,000 kHz. It was found that the capacitance decreased with increasing thermal imaging temperature, probably caused by weakening of chemical bond with increasing temperature. Tan ${\delta}$ decreased upon increasing temperature from $90^{\circ}C$ to $170^{\circ}C$, probably due to the molecular motion of COOH radical or OH radical. The FT-IR measurement reveals that no structural change of the material occurs upon thermal radiation. The SEM measurement shows that the material is stabilized by thermal decomposition with increasing temperature; however, excessive thermal degradation obstructs the stabilization of the material.

첨가제에 의한 전력 cable용 XLPE의 전기적 특성에 관한 연구 (A Study on electrical Characteristics of XLPE by additives)

  • 김규식;손원근;임기조;박수길
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2000년도 추계학술대회논문집
    • /
    • pp.61-64
    • /
    • 2000
  • Three kinds of treeing inhibitors are added to investigate the effect on electrical properties of XLPE. The treeing inhibitors are barbituric acid, 4- (4-Nitrophenylazo) resorcinol and 4- (4-Nitrophenylazo) naphthol. Added amount of each treeing inhibitors varied form 0phr to 2.0phr. In order to know the changes of electrical properties, break down strength, tan$\delta$, and $\varepsilon$$_{r}$ were measured. Experimental results showed that electrical properties of each sample was slightly changed by amount of additives.s.

  • PDF

$ITO/Alq_3/Al$ 구조 유기 발광 소자의 유전분극 현상의 연구 (A Study on the Dielectric Polarization of $ITO/Alq_3/Al$ Structure Organic Light-emitting Diodes)

  • 오용철;신철기;김충혁
    • 전기학회논문지
    • /
    • 제57권1호
    • /
    • pp.73-77
    • /
    • 2008
  • We have investigated dielectric polarization in organic light-emitting diodes using 8-hydroxyquinoline aluminum($Alq_3$) as an electron transport and emissive material. We analyzed the dielectric polarization of organic light-emitting diodes using characteristics of impedance and equivalent circuit of $ITO/Alq_3/Al$. Impedance characteristics was measured complex impedance Z and phase ${\theta}$ in the frequency range of $1{\times}40Hz\;to\;1{\times}10^8Hz$. We obtained complex electrical conductivity, dielectric constant, and loss tangent(tan${\delta}$) of the device at room temperature. And, we obtained the equivalent circuit of $ITO/Alq_3/Al$ through analyzing dielectric constant and dielectric loss tangent. From these analyses, we could interpret a conduction mechanism and dielectric polarization.

절연유의 열열화에 따른 Tan $\delta$와 수분의 변화에 의한 변압기의 예방진단 연구 (Study on Diagnosis for Transformers by Tan $\delta$ and Moisture of Insulation Oil According to Thermal Aging)

  • 황보승;한민구;곽희로;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.241-245
    • /
    • 1988
  • This paper reports the experiments regarding to diagnosis techniques for power transformers by measuring dissipation factor and moisture contents of mineral oils. Thermal aging environments of mineral oils were varied by the specially designed systems. Thermal aging of elevated temperature of $90^{\circ}C$ was performed for about 240 and 460 hours, respectively. Dissipation factor, permittivity, and water content were measured. Our test samples were not exposed to air. Dissipation factor increased while permittivity did not change. The level of dissipation factor determining the insulating quality of mineral oil was compared with the previous results of resistivity and several correction factor.

  • PDF

Radiation Effects on ${\gamma}$-Ray Irradiated Ethylene Propylene Rubber using Dielectric Analysis

  • Kim, Ki-Yup;Ryu, Boo-Hyung;Lee, Chung;Lim, Kee-Joe
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권2호
    • /
    • pp.48-54
    • /
    • 2003
  • To evaluate the radiation degradation of ethylene propylene rubber (EPR), radiation effects on EPR were investigated by using dielectric analysis and thermal-gravimetric analysis. Permittivity, loss factor, tan$\delta$, and thermal decomposition temperature were observed for ${\gamma}$-ray irradiated EPR. As the radiation dose was increased, the peak temperature of the loss factor and tans of EPR were increased and loss factor and tan$\delta$ at peak temperature were decreased. Activation energies were calculated using loss factor and thermal decomposition for ${\gamma}$-ray irradiated EPR as well. The trends of both calculated activation energies showed the same tendencies as radiation dose was increased.

상유전 $ZrTiO_4$박막의 유전특성 분석에 관한 연구 (Dielectric Properties Analysis in Paraelectric $ZrTiO_4$Thin Films)

  • 허진희;김경해;이준신
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.547-549
    • /
    • 2001
  • The dielectric constants and dielectric losses of ZrTiO$_4$thin films deposited by DC magnetron reactive sputtering were investigated. The paraelectric properties were measured in the 100kHz range. As the deposition temperature increased (up to 67$0^{\circ}C$), the dielectric losses (tan$\delta$) decreased (down to 0.017$\pm$0.007), while the dielectric constants ($\varepsilon$) were in the range of 35$\pm$7. Post annealing at 80$0^{\circ}C$ in oxygen for 2h reduced tan$\delta$ down to 0.005$\pm$0.001, higher than those of well-sintered bulk ZrTiO$_4$.

  • PDF

배전용 변압기의 진단을 위한 위상 검출 장치의 개발 (Development of Phase Sensitive Detector for Diagnosis of Distribution Transformers)

  • 김영춘;최도혁;윤용한;민경래;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.547-549
    • /
    • 2000
  • This paper develops phase sensitive detector for diagnosis of distribution transformers. And to detect the $tan{\delta}$ more effectively, this paper used phase sensitive detector. The sensor in oil which could be placed inside of the distribution transformer can measures the $tan{\delta}$ in oil. This could be the important factor and information, and it could be used for the basic information for a precise diagnosis. Establishment of the proposed system helps to build the confidence in monitoring of the oil-filled transformers.

  • PDF