• Title/Summary/Keyword: tack test

Search Result 166, Processing Time 0.024 seconds

Technical-note : Real-time Evaluation System for Quantitative Dynamic Fitting during Pedaling (단신 : 페달링 시 정량적인 동적 피팅을 위한 실시간 평가 시스템)

  • Lee, Joo-Hack;Kang, Dong-Won;Bae, Jae-Hyuk;Shin, Yoon-Ho;Choi, Jin-Seung;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.2
    • /
    • pp.181-187
    • /
    • 2014
  • In this study, a real-time evaluation system for quantitative dynamic fitting during pedaling was developed. The system is consisted of LED markers, a digital camera connected to a computer and a marker detecting program. LED markers are attached to hip, knee, ankle joint and fifth metatarsal in the sagittal plane. Playstation3 eye which is selected as a main digital camera in this paper has many merits for using motion capture, such as high FPS (Frame per second) about 180FPS, $320{\times}240$ resolution, and low-cost with easy to use. The maker detecting program was made by using Labview2010 with Vision builder. The program was made up of three parts, image acquisition & processing, marker detection & joint angle calculation, and output section. The digital camera's image was acquired in 95FPS, and the program was set-up to measure the lower-joint angle in real-time, providing the user as a graph, and allowing to save it as a test file. The system was verified by pedalling at three saddle heights (knee angle: 25, 35, $45^{\circ}$) and three cadences (30, 60, 90 rpm) at each saddle heights by using Holmes method, a method of measuring lower limbs angle, to determine the saddle height. The result has shown low average error and strong correlation of the system, respectively, $1.18{\pm}0.44^{\circ}$, $0.99{\pm}0.01^{\circ}$. There was little error due to the changes in the saddle height but absolute error occurred by cadence. Considering the average error is approximately $1^{\circ}$, it is a suitable system for quantitative dynamic fitting evaluation. It is necessary to decrease error by using two digital camera with frontal and sagittal plane in future study.

Scalable RDFS Reasoning Using the Graph Structure of In-Memory based Parallel Computing (인메모리 기반 병렬 컴퓨팅 그래프 구조를 이용한 대용량 RDFS 추론)

  • Jeon, MyungJoong;So, ChiSeoung;Jagvaral, Batselem;Kim, KangPil;Kim, Jin;Hong, JinYoung;Park, YoungTack
    • Journal of KIISE
    • /
    • v.42 no.8
    • /
    • pp.998-1009
    • /
    • 2015
  • In recent years, there has been a growing interest in RDFS Inference to build a rich knowledge base. However, it is difficult to improve the inference performance with large data by using a single machine. Therefore, researchers are investigating the development of a RDFS inference engine for a distributed computing environment. However, the existing inference engines cannot process data in real-time, are difficult to implement, and are vulnerable to repetitive tasks. In order to overcome these problems, we propose a method to construct an in-memory distributed inference engine that uses a parallel graph structure. In general, the ontology based on a triple structure possesses a graph structure. Thus, it is intuitive to design a graph structure-based inference engine. Moreover, the RDFS inference rule can be implemented by utilizing the operator of the graph structure, and we can thus design the inference engine according to the graph structure, and not the structure of the data table. In this study, we evaluate the proposed inference engine by using the LUBM1000 and LUBM3000 data to test the speed of the inference. The results of our experiment indicate that the proposed in-memory distributed inference engine achieved a performance of about 10 times faster than an in-storage inference engine.

A Study for Perception of Hair Damage Using Friction Coefficient of Human Hair (모발의 마찰계수를 통한 모발 손상 인식 연구)

  • Lim, Byung Tack;Seo, Hong An;Song, Sang-Hun;Son, Seong Kil;Kang, Nae-Gyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.46 no.3
    • /
    • pp.295-305
    • /
    • 2020
  • Treatment for beauty using oxidizing agents damages hair with inducing structural alteration in cuticle layer, degradation of protein, and loss of lipid. This study connects a frictional coefficient upon the damaged hair by an instrumental test to the texture test by human being, and considered a moisture as a factor of the damage. A friction coefficient has been measured upon the hair with successive treatment of dye, perm, and bleach. The friction coefficient from the hair dye-treated three times was defined with 0.60, where 58% of answerer indicated an initial damage point as the hairs of iteration of dye-treatment increased. Even bleach treated three times results in 0.84 of friction coefficient corresponding to 88% of answerer attributed the hair to an initially damaged hair. In order to figure out a lipid loss in hair for human being to respond damage, a friction coefficient of the hair was controlled by removing 18-methyleicosanoic acid (18-MEA). The initial damage has been recognized by 0.60 of the friction coefficient for the 68% of answerer. Since moisture is the largest portion of the components in hair, moisture analysis has been performed to study a relationship between texture of damage and the friction coefficient from an instrumental evaluation. As an iteration of dye increases, the hair became hydrophilic with smaller contact angle. It is found that a damaged hair by dyeing possessed more than 0.42% of moisture compared to a healthy hair. Finally, it is elucidated that an increase of moisture in hair induced higher adhesive force corresponding to the friction coefficient, and the friction coefficient above 0.6 is attributed to the preception of hair damage.

Self Production of Radioisotope and Radiopharmaceuticals Divider (방사성동위원소 및 방사성의약품 분주장치의 자체제작)

  • Hong, Sung-Tack;Park, Kwang-Seo;Kim, Seok-Ki;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.177-180
    • /
    • 2010
  • Purpose: As PET test came to be covered by the pay system of medical insurance (July 1, 2006) and the needs for it becoming increased for laboratory purpose, it became necessary to purchase expensive medical equipments to solve those problems. However, as most of equipments that are operated by cyclotron are very expensive as to amount from tens of millions up to hundreds of millions of won, it is difficult to purchase those equipments from the point of medical organizations. It may be possible to self manufacture those equipments with least costs if their parts functions that meets the operators demands. The Nuclear Medicine department of National Cancer Center (NCC) is trying to manufacture and use equipments that can be made with least costs, including introducing 2 medical equipments that can improves the operator's works. Materials and Methods: Example 1: Self production of radioisotope($^{18}F$) divider was fabricated. The NCC's Nuclear Medicine department acquired one acrylic panel, seven 3-way valve, tubing etc. that can be found in the market to make the main body of divider in cooperation with biomedical engineering, and placed them inside hot cell, and installed switching box outside of hot cell to make it possible to control them from outside. This main body of divider were placed in radioisotope transfer line that are manufactured in the cyclotron. Example 2: Self production of $^{18}F$-FDG automated divider was fabricated. The NCC's Nuclear Medicine department used cavro pump syringe that consists the main body of divider in cooperation with biomedical engineering, biomedical engineering developed programs that divides a certain amount. $^{18}F$-FDG automated divider is placed inside hot cell, and cable chords were used in the equipment, and then it was connected to PC outside hot cell to make it possible to control the $^{18}F$-FDG automated divider. Results: From the NCC's Nuclear Medicine department tests that were carried out from March, 2007 until now, we found out that radioisotope can be sent to radiopharmaceuticals composite module we want, and from the tests that are carried out at NCC's Nuclear Medicine department using $^{18}F$-FDG automated divider since August, 2009 it was possible to distribute radiopharmaceuticals into vial intended. Conclusion: Through the two examples above, we found out that costs can be reduced by self manufacturing expensive equipments from NCC's cyclotron room with least costs. Also, it decreased radiation exposure dose on workers, and set up problem solving processes in cooperation with lots of parties related.

  • PDF

The Role of Initial Relative Renal Function in Unilateral Hydronephrosis (일측 폐색성 및 역류성 수신증에서 술전 상대적 신기능의 의미)

  • Han Sang-Won;Kang Seon-Jung;Kwon Min-Jung;Kim Dae-Joong;Choi Seung-Kang;Lee Tack
    • Childhood Kidney Diseases
    • /
    • v.3 no.2
    • /
    • pp.203-208
    • /
    • 1999
  • Purpose: The information on the change of the relative renal function after operation is essential to set the initial treatment plan in unilateral hydronephrosis. So we analyzed the preoperative and postoperative relative renal function, and observed the functional changes by operation and reliability of the various factors in those changes. Materials and Methods: A retrospective trial was done of 81 patients, 35 ureteropelvic junction(UPJ) obstruction and 46 vesicoureteral reflux(VUR), among 393 patients undergoing operations at our institution from March. 1992 to February. 1997. The patients who had infravesical abnormalities, abnormal contralateral kidney and insufficient research data were excluded. We determined the relative renal functions using DTPA and MAG3 scan in UPJ obstruction and DMSA scan in VUR. The mean observation period after operation was 2.01(0.25-4) years. Results: A. UPJ Obstruction 1. The relative renal function was improved significantly after operation(P=0.0007). 2. The kidneys which have preoperative functions between 20% and 40% improved significantly in relative renal function comparing to the kidneys of the other functions(P=0.0046). B. VUR 1. The renal functions didn't improve significantly after operation(P>0.05). 2. There was no significant factor affecting the prognosis in renal functions. Conclusions: 1. The kidneys with UPJ Obstruction show the difference in functional improvement after operation according to the degree of the preoperative renal function, but more investigations about the exact value are needed. 2. In VUR there was no difference between preoperative and postoperative functions, the theoretical basis on objectives of the operation could be the symptoms or factors except the operation.

  • PDF

A Small Outbreak of Measles in 2013: In a Single Hospital in Northern Gyeonggi-do (2013년 경기 북부 한 병원에서 확인된 소규모 홍역 유행)

  • Kim, Min Jae;Kim, So Hyun;Kim, Sung Un;Jang, Mi Jin;Lee, Hyun Seung;Kim, Young Hoon;Han, Ji Whan;Kim, Jin Tack;Jang, Pil Sang
    • Pediatric Infection and Vaccine
    • /
    • v.22 no.2
    • /
    • pp.63-68
    • /
    • 2015
  • Purpose: This study analyzed a small outbreak of measles at a single hospital located in northern Gyeonggi-do in 2013. Methods: We reviewed the medical records of measles patients at The Catholic University of Korea Uijeongbu St. Mary's Hospital from August to October, 2013. Results: Fifteen children were confirmed to have measles by RT-PCR and serum IgM test; 1 neonate, 11 infants, and 3 toddlers. None of the patients had received Measles-Mumps-Rubella vaccination. All patients showed B3 type in viral genotyping. Nine children (60%) had been exposed to measles during treatment for other diseases in the pediatric ward. Incubation period was between 8 and 15 days. Fever started at a median 10 days after exposure and persisted for a median of 8 days. Rash showed at a median 13 days after exposure. Respiratory complications were observed in 40% of patients. Diarrhea developed in 53% of patients. Conclusion: Although measles has been well-controlled due to the high rate of vaccination coverage, it is possible to have an outbreak at any given time, especially in infants. We must learn from this outbreak, and remain fully aware of the possibility of reemergence and provide proper management, including vaccination or immune globulin administration, to infants exposed to measles. Reevaluation of serum IgG titer of neonates, infants, and pregnant women may be the first step to prevent further outbreaks.