• Title/Summary/Keyword: tPA

Search Result 462, Processing Time 0.027 seconds

Analysis of Plasminogen Activators Activity and Three Dimensional (3D) Culture of Endometrial Cells in Pigs (돼지 자궁내막 세포의 3차원 배양과 Plasminogen Activator 활성화 분석)

  • Cha, Hye-Jin;Lee, Sang-Hee;Cheong, Hee-Tae;Yang, Boo-Keun;Park, Choon-Keun
    • Journal of Embryo Transfer
    • /
    • v.28 no.3
    • /
    • pp.273-280
    • /
    • 2013
  • The aim of this study was to establish a three dimensional (3D) culture system of endometrial cells and to examine the plasminogen activators (PAs) activity in porcine uterine. The 3D culture system in porcine endometrial cells was composed to mixture 3D gel, stromal cells and epithelial cells. The 3D culture system was used to identify normal structure search as uterine tissue and PAs expression in this study. In results, porcine endometrium epithelial cells forming a top monolayer and endometrium stromal cells developed as fibroblast-like within 3D matrix scaffold. Expression of urokinase-type PA (uPA) and tissue-type PA (tPA) were observed during the 3D culture using immunofluorescence. PA activity in 3D-cultured endometrial cells was no significant difference between the tissue type, but 2D culture system were significantly lower than in 3D-cultured endometrial cells (P<0.05). Therefore, basic system and functional aspect of 3D culture could be established with similar system of endometrium tissue. We suggest that this study was assumed applicable as baseline data to investigate mechanism between porcine uterus cells in vitro.

NASAL DEVIATION IN PATIENTS WITH MANDIBULO-FACIAL ASYMMETRY (안모 비대칭환자의 두부정중선에 대한 비부의 편위)

  • Park, Ji-Hwa;Son, Seong-Il;Jang, Hyun-Jung;Kwon, Tae-Geon;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.2
    • /
    • pp.151-159
    • /
    • 2005
  • The purpose of this study was to evaluate the nasal deviation in mandibular prognathism with mandibulo-facial asymmetry. There were 40 patients whose mandibular prognathism with/without facial asymmetry were treated with orthognathic surgery from March 2002 to October 2003. The Group A(n=20) had a mandibulo-facial asymmetry over 6mm menton deviation in cephalogram PA and the Group B(n=20) had a mandibular prognathism. The preoperative frontal photograph, cephalogram PA and three dimensionalcomputed tomography(divided in hard tissuse image and soft tissue image) of two group was evaluated NDA(nasal deviation angle) and MDA(mandibular deviation angle). The NDA was statistical difference between asymmetry Group A and symmetry Group B(p<0.01), and was deviated in affected side of asymmetry. The MDA were also statistical difference between Group A and Group B(p<0.01), however the measurements of MDA between the frontal photograph, 3D-CT and cephalogram PA were similar to each others. The low correlation of NDA between frontal photograph and cephalogram PA in Group A and B demonstrate that we couldn't assess nasal deviation in cephalogram PA. It could be concluded that patients with mandibulo-facial asymmetry have a nasal deviation and clinician must remember this fact when they assess and treat patients.

Effects of Solder Particle Size on Rheology and Printing Properties of Solder Paste (미세피치 접합용 솔더 페이스트의 솔더 분말 크기에 따른 레올로지 및 인쇄 특성 평가)

  • Jun, So-Yeon;Lee, Tae-Young;Park, So-Jeong;Lee, Jonghun;Yoo, Sehoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.2
    • /
    • pp.91-97
    • /
    • 2022
  • The wettability and rheological properties of solder paste with the size of the solder powder were evaluated. To formulate the solder paste, three types of solder powder were used: T4 (20~28 ㎛), T5 (15~25 ㎛), and T6 (5~15 ㎛). The viscosities of the T4, T5, and T6 solder pastes at 10 RPM were 155, 263, and 418 Pa·s, respectively. After 7 days, the viscosity of the T4 solder paste slightly increased by 2.6% and that of T5 was increased by 20.6%. The viscosity of the T6 solder paste after 7 days could not be measured due to high viscosity. The viscosity variation with solder particle size also affected on the printability of the solder. In the case of the T4 solder paste, printability, slump, bridging, and soldering properties were excellent. On the other hand, T5 showed slight dewetting and solder ball defects. Especially, T6, which the smallest powder size, showed poor printability and dewetting at the edge of solder.

Synthesis and Characterization of Polymer and Polymer Complex with Some Transition Metal Ions (몇 개의 전이금속 이온과 고분자와 고분자 Complex의 합성과 특성연구)

  • Badr, S.K.;Mohamed, T.Y.
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.1
    • /
    • pp.43-48
    • /
    • 2010
  • Polyamide derived from azo compound of o-amino phenol coupled with acetyl acetone, maleic anhydride acid and p-phenylene diamine were prepared. The prepared polyamide (PA) was refluxed with metal salts of transition metal ions include, $Co^{+2},\;Cr^{+2},\;Ni^{+2},\;Cu^{+2},\;Zn^{+2},\;Cd^{+2}$ and $Fe^{+3}$ in dimethyl formamide (DMF) in different molar ratios. These complexes were characterized and identified by elemental and thermal analysis, IR, 1H NMR spectra. The data showed that PA ligand coordinates with metal ions in abidentate manner through donating N=N and O-H groups. The metal ions are surrounded by coordinated water molecules and anions to establish the geometrical structure of the complexes. The thermal analysis degradation at different temperatures explained the weight loss of hydrated water and the decompositions of complexes until a constant weight loss of metal oxides is obtained.

Changes in Arterial Oxygen Tension($PaO_2$) and Cardiac Arrhvthmias after Endotracheal Suction (기관내 흡인 실시 후의 동맥혈 산소 분압 변화와 심부정맥 발현에 관한 연구)

  • Kim, Sun-Wha;Shin, Jung-Sook;Choi, Young-Hee
    • The Korean Nurse
    • /
    • v.33 no.4
    • /
    • pp.62-85
    • /
    • 1994
  • The data were analyzed by using an S. P. S. S. computerized program for mean, standard deviation, percentage and paired t-test. The results of this study were as follows: 1. The increase in $PaO_2$ after hyperoxygenation and hyperinflation was highly statistically significant(p=0.041), and the increase in $PaO_2$ immediately after suctioning was not significant (p=0.752). The time of lowest $PaO_2$ was 30 seconds after the endotracheal suction. 2. The occurrance of cardiac arrhythmia after the endotracheal suction included sinus tachycardia, sinus arrhythmia, sinus bradycardia, premature atrial contraction (PAC), and premature ventricular contraction (PVC). The most frequent cardiac arrhythmia was sinus tachycardia (a subjects). Sinus arrhythmia was observed in 5 subjects and continued till 10 minutes after suctioning in two of these. Sinus bradycardia occurred in only 3 subjects and among them, 1 subjects shows sinus arrythmia till 10 minutes after suctioning along. PAC was observed in only one subject and continued till five minutes after suctining along with sinus arrhythmia. PVC was observed in three subjects: it lasted for only 30 seconds after suctioning in two subjects. but continued for 10 minutes after suctioning in the third. 6 subjects manifested two kinds of Cardiac arrhythmia Three of them showed sinus tachycardia with PVC, another 2 showed sinus bradycardia with sinus arrhythmia, and the other subject showed sinus arrhythmia with PAC. 3. The increases in heart rate during the endotracheal suction immediately after and at 30 seconds after suctioning were statistically significant (p=0.005). The increase in heart rate at one minute after suctioning was also significant (p=0.023). The increase in heart rate continued until 10 minutes after the endotracheal suction, but was not statistically significant In this study, endotracheal suctioning with hyperoxygenation and hyperinflation was effective in preventing a decrease in $PaO_2$ after suctioning, but not in preventing cardiac arrhythmias. Nurses should be aware of the complications of endotracheal suctioning and do effective hyperoxygenation and hyperinflation before and after suctioning. Further research is needed to develop a efficient endotracheal suction method which will minimize complications. This study needs to be replicated with different population of patients intubatted or having a tracheostomy, specifically, patients who cardiac or pulmonary desease. The data were analyzed by using an S. P. S. S. computerized program for mean, standard deviation, percentage and paired t-test. The results of this study were as follows: 1. The increase in $PaO_2$ after hyperoxygenation and hyperinflation was highly statistically significant(p=0.041), and the increase in $PaO_2$ immediately after suctioning was not significant (p=0.752). The time of lowest $PaO_2$ was 30 seconds after the endotracheal suction. 2. The occurrance of cardiac arrhythmia after the endotracheal suction included sinus tachycardia, sinus arrhythmia, sinus bradycardia, premature atrial contraction (PAC), and premature ventricular contraction (PVC). The most frequent cardiac arrhythmia was sinus tachycardia (a subjects). Sinus arrhythmia was observed in 5 subjects and continued till 10 minutes after suctioning in two of these. Sinus bradycardia occurred in only 3 subjects and among them, 1 subjects shows sinus arrythmia till 10 minutes after suctioning along. PAC was observed in only one subject and continued till five minutes after suctining along with sinus arrhythmia. PVC was observed in three subjects: it lasted for only 30 seconds after suctioning in two subjects. but continued for 10 minutes after suctioning in the third. 6 subjects manifested two kinds of Cardiac arrhythmia Three of them showed sinus tachycardia with PVC, another 2 showed sinus bradycardia with sinus arrhythmia, and the other subject showed sinus arrhythmia with PAC. 3. The increases in heart rate during the endotracheal suction immediately after and at 30 seconds after suctioning were statistically significant (p=0.005). The increase in heart rate at one minute after suctioning was also significant (p=0.023). The increase in heart rate continued until 10 minutes after the endotracheal suction, but was not statistically significant In this study, endotracheal suctioning with hyperoxygenation and hyperinflation was effective in preventing a decrease in $PaO_2$ after suctioning, but not in preventing cardiac arrhythmias. Nurses should be aware of the complications of endotracheal suctioning and do effective hyperoxygenation and hyperinflation before and after suctioning. Further research is needed to develop a efficient endotracheal suction method which will minimize complications. This study needs to be replicated with different population of patients intubatted or having a tracheostomy, specifically, patients who cardiac or pulmonary desease.

  • PDF

A Study on the Pulmonary Hemodynamic Changes before and after PEEP in ARDS (호흡부전증에세 호기말 양압호흡법 치료 전후의 폐혈류역학적 변화에 관한 연구)

  • Chung, June-Key;Shin, Seong-Hae;Khang, Shin-Kwang;Park, Sung-Ki;Lee, Myung-Chul;Cho, Bo-Youn;Koh, Chang-Soon;Kim, Yong-Lack;Kim, Kwang-Woo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.18 no.1
    • /
    • pp.45-53
    • /
    • 1984
  • The purpose of this study is to observe the changes of pulmonary capillary permeability and various hemodynamic parameters before and after Positive End-Expiratory Pressure(PEEP) in Adult Respiratory Distress Syndrome (ARDS). Using a canine oleic acid induced ARDS model, we measured the pulmonary capillary permeability with a slope of lung: heart radioactivity ratio, hemodynamic parameters with Swan-Ganz catheter and blood gas tensions. 1) In normal and ARDS dogs, the PEEP didn't significantly influence the slope of lung: heart radioactivity ratio. But in ARDS group the slope index was increased compaired with that of control group (p<0.05). 2) Also in ARDS group, $PaO_2$ was significantly decreased, and $PaCO_2,\;PvCO_2$, MPAP, $AaDO_2$, Qs/Qt were significantly increased compared with those of control group (p<0.05). 3) In normal dogs, the PEEP didn't influence blood pH or gas tension, $AaDO_2$, Qs/Qt, or hemodynamics. 4) In ARDS dogs, however, the PEEP significantly increased $PaO_2$ and decreased $AaDO_2$, Qs/Qt (p<0.05).

  • PDF

A Case of Neonatal Onset Propionic Acidemia with Mild Clinical Presentations (경한 임상 경과를 보인 신생아 시기의 프로피온산혈증 1례)

  • Kim, Kyung-Ran;Kim, Jinsup;Huh, Rim;Park, Hyung-Doo;Cho, Sung Yoon;Jin, Dong-Kyu
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.16 no.1
    • /
    • pp.47-51
    • /
    • 2016
  • Propionic acidemia (PA) is an autosomal recessively inherited disorder of the organic acid metabolism. It is caused by a deficiency of propionyl-CoA carboxylase (PCC). PCC is a heteropolymeric enzyme composed of ${\alpha}$- and ${\beta}$-subunits. The clinical symptoms of PA are heterogeneous and present vomiting, dehydration, hypotonia, and lethargy, and it can result in death. The typical presentations of neonatal onset PA are life-threatening metabolic acidosis and hyperammonemia. Here, we described a case of neonatal onset PA with mild clinical presentations. She was born to a healthy mother without complications. No significant illness was observed until nine days after birth. She started exhibiting poor oral feeding, vomiting, lethargy, and hypotonia at ten days old. Her laboratory results showed mild hyperammonemia and acidosis. The initial diagnosis was neonatal sepsis and she was treated with antibiotics. However, her clinical symptoms didn't improve. So we considered a metabolic disease. She was given nothing by mouth and intravenous hydration and nutrition support was performed. Propionylglycine and 3-hydroxypropionic acid were showed high concentrations in urine by gas chromatograph mass spectrometry (GC-MS). C3 level of acylcarnitine analysis elevated 10.4 uM/L (range, 0.200-5.00) in plasma. We took gene analysis for PA to be based on the symptoms and laboratory results. We detected PCCB gene mutation and diagnosed PA. She survived without severe neurologic defects and complications and was hospitalized only three times with upper respiratory tract infections for 7 years. We report a case of a ten days old neonate with PA presenting without severe metabolic acidosis and hyperammonemia who was effectively treated with early aggressive care and conventional methods.

  • PDF

A Comparative Study of Patient Dose and Image Quality according to the Presence or Absence of Grid During Chest PA Radiography using an Auto Exposure Control System (자동 노출 조절장치를 사용한 흉부 후·전 방향 방사선 검사 시 격자 유·무에 따른 환자 선량과 영상품질 비교 연구)

  • So-min Lee;Han-yong Kim;Dong-hwan Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.573-579
    • /
    • 2023
  • This study compares dose difference between the presence or absence of grid in Chest PA radiography using auto exposure control and compares image quality among presence, absence or virtual grid, and proposes a new clinically useful grid combination for chest radiography. The human body phantom was placed Chest PA position and the dosimeter was placed at T6. The same irradiation conditions and field size were applied. 30 images were obtained in the state in which grid was applied and in the state in which grid was not applied, and an additional 30 images in which the virtual grid was applied to the image without the grid were obtained. Radiation dose was presented to entrance surface dose. The image quality was analyzed by comparing the signal-to-noise and contrast-to-noise ratio. ESD decreased by 48% when the grid was not used, compared to when the grid was used. SNR and CNR increased by 32% and 30% compared to grid use when grid was not used, respectively. In the case of using the virtual grid, it increased by 18% and 16% respectively, compared to the case of using the grid. As a result of this study, it is believed that when using a virtual grid instead of a grid, the quality of the image can be maintained while reducing the patient dose.