• Title/Summary/Keyword: t/D ratio

Search Result 1,166, Processing Time 0.033 seconds

Shear behavior of the hollow-core partially-encased composite beams

  • Ye, Yanxia;Yao, Yifan;Zhang, Wei;Gao, Yue
    • Steel and Composite Structures
    • /
    • v.44 no.6
    • /
    • pp.883-898
    • /
    • 2022
  • A hollow-core partially-encased composite beam, named HPEC beam, is investigated in this paper. HPEC beam comprises I-beam, longitudinal reinforcement, stirrup, foam formwork, and cementitious grout. The foam formwork is located on both sides of the web, and cementitious grout is cast within the steel flange. To investigate the shear performance of HPEC beams, static loading tests of six HPEC beams and three control beams were conducted. The shear span ratio and the number of studs on the shear behavior of the HPECspecimens were studied. The failure mechanism was studied by analyzing the curves of shear force versus both deflection and strain. Based on the shear span ratio (𝜆), two typical shear failure modes were observed: shear compression failure when 1.6 ≤ 𝜆 ≤ 2; and diagonal compression failure when 𝜆 ≤ 1.15. Shear studs welded on the flange can significantly increase the shear capacity and integrity of HPEC beams. Flange welded shear studs are suggested. Based on the deformation coordination theory and superposition method, combined with the simplified modified compression field model and the Truss-arch model, Modified Deformation Coordination Truss-arch (M.D.C.T.) model was proposed. Compared with the shear capacity from YB9038-2006 and JGJ138-2016, the calculation results from M.D.C.T. model could provide reasonable predictions.

Nitrogen Removal in the Multi-stage Bed Attached Growth Process of $A^2/O$ System with Interanal Recycle Ratio (다단층 부착성장 공법($A^2/O$향)에서 순환비에 따른 질소제거)

  • 최규철;윤용수;정일현
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.95-102
    • /
    • 1997
  • The process which can stabilize water quality of treatment and improve nitrogen removal rate under the condition of high organic loading was developed by charging fibrous HBC media to single sludge nitrification-denitrification process. This process was operated easier, minimized the treatment cost, and shortened the retention time. To improve T-N removal rate, a part of nitrifing liquid at aerobic zone was recycled to anoxic zone by approximate internal recycle ratio. The experimental results are as follows ; T-N removal efficiency in the organic volumetric loading 0.14-0.19 kg/COD/m$^{3}$·d was obtained asmaxium of 85% at internal recycle ratio 2.5 and in more ratio than this it was decreased. Organic removal efficiency was about 91% under the overall experimental conditions and not influenced by recycle ratio.

  • PDF

Design of Downlink Channel for Transportable KOMPSAT Ground Station Using Sub-Carrier Signal (부 반송파를 사용하는 이동형 다목적실용위성 관제국에 대한 하향 링크 채널 설계)

  • Ahn, Sang-Il;Park, Dong-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.3
    • /
    • pp.313-321
    • /
    • 2009
  • This paper describes the downlink design of a transportable small-sized KOMPSAT ground station using sub-carrier signal. Based on the analysis of the transmission modes of satellite real-time telemetry and range measurement signals, the downlink channel design of KOMPSAT ground station using sub-carrier signal was processed. By considering the threshold signal-to-noise ratio of real-time 2 kbps telemetry signal and the required signal-to-noise ratio for satellite range measurement, the small-sized KOMPSAT downlink channel with G/T value of 6.5 dB/K was designed. The real G/T of implemented ground station was proven to be 6.62 dB/K when measured using the Sun. Moreover, through interface test with KOMPSAT, the ground station has shown the required link performance for real-time telemetry acquisition using sub-carrier and was consequently evaluated to be adequate for a transportable small-sized KOMPSAT ground station.

The Prediction of the Hydrodynamic Coefficients of Added Mass for Ship in Shallow Waters (천수역 선체 부가질양에 대한 추정 근사식에 관한 연구)

  • 이윤석;김순갑;조익순
    • Journal of the Korean Institute of Navigation
    • /
    • v.24 no.3
    • /
    • pp.123-132
    • /
    • 2000
  • In order to improve the ship maneuverability, It is important to estimate precisely the hydrodynamic coefficients of added mass forces acting on a ship especially in shallow waters, and simple methods for predicting such hydrodynamic forces Is also very desirable. In the previous paper using 3-Dimension potential flow theory, it has been demonstrated that potential calculation is available to estimate added mass coefficients. The present work is aimed at the suggestion of the simplified formulas for predicting the translation and lateral motion of added mass coefficients in shallow water. So, 3-D potential flow theory is also used to calculate the added mass coefficients in deep and shallow waters for Series 60 model which has 5 different kinds of block coefficients (0.6-0.8), SR196 model and T/S HANNARA. After some series computation, simplified formulas for Predicting the added mass force in shallow waters is suggested based on the computation results of Series 60 model. The formulas consist of the combination of principal dimensions and the water depth; d/B, Cb, d/H. The predicted results are compared with the Computation results for SR196 model and T/S HANNARA. The precision of predicted results by simplified formulas are good enough for the practical use. (d/B : draft-Breadth ratio, d/H draft-Water depth ratio, Cb : Block coefficients).

  • PDF

Fabrication and measurement of a Weathercock-Shaped Microstrip patch Antenna with T-Slot for 5.25-GHz Band Wireless LAN (5.25GHz 무선 LAN을 위한 T-Slot Weathercock-Shaped 마이크로스트립 패치 안테나 설계 및 제작)

  • Choi Sun-Ho;Jeong Gyey-Teak;Lee Hwa-Choon;Kwak Kyung-Sup
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.12A
    • /
    • pp.1183-1187
    • /
    • 2005
  • In this paper, a weathercock-shaped microstrip patch antenna for application in 5.25GHz band wireless LAN is designed and fabricated. To obtain sufficient bandwidth in VSWR<2, the T-slot is inserted on the patch, the coaxial probe source is used. The measured result of fabricated antenna obtained 350MHz or about $7.62\%$ bandwidth in VSWR<2 referenced to the center frequency, the gain of 5.25${\~}$6.70dBi. The experimental 3-dB beam width is shown to be broad across the pass band in azimuth and elevation at $80.32^{\circ}$ and $83.88^{\circ}$, in several.

A Comparative of the Harmany of Tone on Tone Coloration according to Transformation of Color Area-Ratio in Shirt and Necktie (셔츠와 넥타이의 톤 온 톤 배색 면적비 변화에 따른 조화감 비교)

  • Lim, Ji-Young
    • Fashion & Textile Research Journal
    • /
    • v.9 no.2
    • /
    • pp.138-144
    • /
    • 2007
  • The purpose of this research was to compare the harmony of tone on tone coloration according to transformation of color area-ratio in shirt and necktie. The respondents were asked to evaluate 48 stimuli of the shirt and necktie with the coloration of the shirt/necktie, the necktie/shirt was separately compounded to be 4 tones such as vivid, light, dull, dark. The subjects were 288 female undergraduate students. The data was analyzed by using SPSS program. Analysis methods were ANOVA, LSD test and t-test. The results of each can be summerized as follows. As to the red, combination of v-lt made a difference in the harmony of coloration according to the transformation of color area-ratio. As to the blue, combination of v-lt, v-dk, lt-d made a difference in the harmony of coloration according to the transformation of color area-ratio. As to the purple, v-lt, v-d was evaluated as harmonized coloration regardless of area-ratio by both male and female students. As to the green, v-lt, lt-d was evaluated as harmonized coloration regardless of area-ratio by both male and female students.

A Study on Shear Capacity of High Strength Lightweight Reinforced Concrete T-Beams (고강도 경량콘크리트를 사용한 철근콘크리트 T 형보의 전단성능)

  • 김진수;김원호;박성무
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.220-225
    • /
    • 1993
  • This paper is an experimental study on shear capacity of the high strength lightweight reinforced concrete beams with shear-depth ratio between 1.5 and 2.5. Thirteen T & rectangular beams were tested to determine their diagonal cracking and ultimate shear capacity. The major variables are shear span-depth ratio (a/d=1.5, 2.0, 2.5), concrete compressive strength(f'c=210, 24., 270㎏/㎠) and tensile steel ratio( =0.6, 1.2%). Based on results obtained from experiment of high strength lightweight reinforced concrete Beam & normal concrete, the following conclusions were drawn. (1) The shear capacity of high-strength lightweight concrete is less 15% than that of normal concrete under same condition. (2) As the results of Comparing this experimental datas with other various formulas. It is regarded that ACI 318-89 shear strength formula related tensile strength is proper to design formula of shear strength of high-strength lightweight reinforced concrete using lightweight concrete.

  • PDF

The Effects of Changing of Hydraulic Retention Time and Charging Media on the Removal of Nitrogen and Phosphorus in the Up-flow Anaerobic/Anoxic Reactor and Water-mill for Sewage Treatment (상향류식 혐기성조, 무산소조 및 수차호기조를 이용한 하수처리시 수리학적 체류시간의 변화와 메디아 충진이 질소 및 인 제거에 미치는 영향)

  • Shin, Myoung-Chul;Lee, Young-Shin
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.1
    • /
    • pp.64-70
    • /
    • 2009
  • The aims of this study is to examine the effects of the changes in HRT(Hydraulic Retention Time) and media charge in a water-mill, among other operation factors, on the nitrogen and phosphorus removal in order to use up-flow anaerobic reactors, anoxic reactors and water-mill aerobic reactors for sewage treatment. The extension of HRT improved the nitrogen removal efficiency, however the removal pattern was constant regardless of HRT. The removal of phosphorus was constant (80%-90%) regardless of the change in HRT. The removal rate with change in influx load varied such that at the OLR (Organic Load Rate) of 1-3 kg/d, the T-N removal efficiency was 80.7%-88.9% and the T-P removal efficiency was 82.9%-89.3% while at the NLR (Nitrogen Loading Rate) of 0.108-0.156 kg/d the removal efficiencies were 80.7-88.9% (T-N) and 82.9-89.3% (T-P). The analyses of the nitrogen and phosphorous removal characteristics with the C/N and C/P ratio showed that the mean T-N removal rate was 88% at the C/N ratio of 1.2-2.6, and that the mean T-P removal rate was 86% at the C/P ratio of 7.2-14.1. Also, the analysis of nitrogen and phosphorous removal characteristics were analyzed in relation to media charge. The comparison between with and without media charge in the water-mill showed that while the nitrogen removal efficiencies were 86-94% and 85-89% respectively, the difference of phosphorous removal efficiencies were between the two conditions was not significant, thus it suggested that the media charge has less effect on the removal efficiency of phosphorous compared to that of nitrogen.

Flow Characteristics of T-junction Pipe (T-합류관의 유동특성)

  • Kim, M.K.;Bae, D.S.;Kwon, O.B.;Yang, J.K.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.528-533
    • /
    • 2005
  • This paper presents the study of flows at T-junction pipe with orifices. Experiments were carried out for several flow rates, orifice sizes, and pressure differences. Numerical simulations were also done to get more data for the wide range of flow rates. Experimental results and numerical ones are in a good agreement. Due to the effect of T-junction part, the flow rates at the lateral pipe are greater than those at straight pipe for the same pressure differences. When orifices were added, the effects of T-junction part on the ratio of flow rates and the ratio of loss coefficients reduced.

  • PDF