• Title/Summary/Keyword: system upgrade

Search Result 520, Processing Time 0.034 seconds

Retrofit of Analog Boiler Control Systems with Digital Control Systems in a Thermal Power Plant

  • Park, Doo-Yong;Byun, Seung-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1304-1308
    • /
    • 2005
  • This paper presents the case that the existing analog control systems were retrofitted with digital DCS(Distributed Control System)s for boiler unit in thermal power plant. Replacement of existing worn-out or obsolete analog control systems has been considered. Replacement of existing analog control systems with another analog control systems has lots of difficulties in maintaining the systems due to being out of stock. Due to those difficulties, existing analog control systems have been retrofitted with digital DCSs in many industrial sites. KEPRI(Korea Electric Power Research Institute) accomplished the project that retrofitted analog control systems with the developed DCSs for boiler unit in middle-scale coal-fired thermal power plant. The benefits of an upgrade to digital control include a increase of reliability due to system redundancy, ease of modifying the control logic and the parameters of function block, ease of maintenance due to available spare parts, improvement of information display, ease of modifying MMI(Man Machine Interface) displays, a increase in system availability, and improvement of control performance. This paper describes how to use the parameters of existing analog controllers, the implementation of digital PID controller, control system configuration for boiler unit in thermal power plant, some boiler control loops, control result during commissioning, and the comparison of boiler characteristic test data after retrofitting with the existing test data.

  • PDF

The Characteristics and Prospects of Hybrid Propulsion Systems for Unmanned Aerial Vehicle (무인기용 하이브리드 추진시스템의 특성 및 발전전망)

  • Park, Tosoon;Song, Jaeho;Kwon, Sejin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.554-559
    • /
    • 2017
  • Recently, the global attention is focused on the development of the renewal aero-propulsion systems proved in the air pollution, the noise, the great operational cost, safety and risks. Especially, various study are conducting for the development of the advanced high power to weight ratio aircraft through the significant reduction of fuel consumption and upgrade of the propulsion efficiency, using the alternative propulsion system developments such as hydrogen and solar power system. The hybrid propulsion system can be the representative propulsion system which get the power sources by combining the merits of two or more power sources. In this study, the advancement trends, characteristics, design method which can be applied to the renewal future UAV development.

  • PDF

A Qualitative Study on Steering of Education Accreditation: With Case Study on Korean Medicine Education (학문분야별 평가인증제 운영에 관한 질적 사례 연구: 한의학을 중심으로)

  • Seo, Dongin;Shin, Sangwoo
    • The Journal of Korean Medicine
    • /
    • v.40 no.3
    • /
    • pp.21-34
    • /
    • 2019
  • Objectives: The purpose of this article is to develop steering of program accreditation system in Korean Medicine Education through meta-evaluation. For this study, the subjects of our research were categorized as the accreditation criteria and system, results and effects, tasks for improvement on Korean Medicine Education. Methods: We conducted Focus Group Interview on 102 full-time professors with experience of participating on accreditation of Korean Medicine Education from 12 college of Korean Medicine Education and we analyzed it by thematic analysis. Results: The accreditation criteria and program evaluation system of Korean Medicine were listed as 'Confusion about the goals of program evaluation', 'High hurdles on accreditation', 'obsession to success cases', 'Small college complaints about applying the same criteria', 'Dilemma of quantitative and qualitative evaluation'. The results and effects of program evaluation in Korean Medicine Education were listed as 'Establishment of base infrastructure for basic medical education', 'Benchmarking and exchanging opinions through evaluation certification', 'Resistance to documents and document-based evaluation', and 'Double-sided of evaluation certification'. As for the tasks for further improvement, the following list is suggested. 'Actively promote evaluation certification', 'Simplification and standardization of forms', 'Requesting for activating about Evaluation committee', 'Need for consulting before regular evaluation'. Conclusion: It is necessary to upgrade the accreditation system and make efforts to improve the issues discovered for better Korean Medicine Education.

Suggestion of Efficient High Dose Spent Filter Handling and Compaction Equipment

  • Lee, Kyungho;Chung, Sewon;Park, Seonghee;Kim, HuiGyeong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.2
    • /
    • pp.243-253
    • /
    • 2022
  • Spent filters with a high radiation dose rate of 2 mSv·hr-1 or more are not easily managed. So far, the Korean policy for spent filter disposal is to store them temporarily at nuclear power plants until the waste filters can be easily managed. Nuclear power plant decommissioning in Korea is starting with Kori unit 1. Volume reduction of waste generated during decommissioning can reduce the cost and optimize the space usage at disposal site. Therefore, efficient volume reduction is a very important factor during the decommissioning process. A conceptual method, based on the experiences of developing 200 and 800 ton compactors at Orion EnC, has been developed considering worker exposure with the followings a crusher (upgrade of compaction efficiency), an automatic dose measuring system with a NaI(Tl) detector, a shield box, an inner drum to prepare for easy handling of drums and packaging, a 30 ton compactor, and an automatic robot system. This system achieves a volume reduction ratio of up to 85.7%; hence, the system can reduce the disposal cost and waste volume. It can be applied to other types of wastes that are not easily managed due to high dose rates and remote control operation necessity.

Upgrade of gamma electron vertex imaging system for high-performance range verification in pencil beam scanning proton therapy

  • Kim, Sung Hun;Jeong, Jong Hwi;Ku, Youngmo;Jung, Jaerin;Cho, Sungkoo;Jo, Kwanghyun;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • v.54 no.3
    • /
    • pp.1016-1023
    • /
    • 2022
  • In proton therapy, a highly conformal proton dose can be delivered to the tumor by means of the steep distal dose penumbra at the end of the beam range. The proton beam range, however, is highly sensitive to range uncertainty, which makes accurately locating the proton range in the patient difficult. In-vivo range verification is a method to manage range uncertainty, one of the promising techniques being prompt gamma imaging (PGI). In earlier studies, we proposed gamma electron vertex imaging (GEVI), and constructed a proof-of-principle system. The system successfully demonstrated the GEVI imaging principle for therapeutic proton pencil beams without scanning, but showed some limitations under clinical conditions, particularly for pencil beam scanning proton therapy. In the present study, we upgraded the GEVI system in several aspects and tested the performance improvements such as for range-shift verification in the context of line scanning proton treatment. Specifically, the system showed better performance in obtaining accurate prompt gamma (PG) distributions in the clinical environment. Furthermore, high shift-detection sensitivity and accuracy were shown under various range-shift conditions using line scanning proton beams.

Reliability Study for Upgrade of Diagnosis System of Oriental Medicine DSOM(r) S.1.1 (한방진단설문지 DSOM (r) S.1.1의 Upgrade를 위한 신뢰도 연구)

  • Lee, In-Seon;Kim, Jong-Won;Chi, Gyoo-Yong;Lee, Yong-Tae;Kim, Kyu-Kon
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.26 no.1
    • /
    • pp.88-97
    • /
    • 2012
  • DSOM(Diagnosis System of Oriental Medicine), questionnaire for oriental medical(medicine) diagnosis is an online survey system containing 152 questions for female, 149 questions for male that asking the basic symtoms of 16 pathogenic factors(病機). The result of DSOM denotes reliability according to the level of major symptoms of each pathogenic factor. Standard level of reliability is equal to all 16 pathogenic factor basically except phlegm(痰). In case of phlegm(痰) we give different weight depending on whether the factor includes gray color under the orbit(痰飮氣) or not. To examine reliability of DSOM, statistical analysis has been done to the data of felmale 10101, male 1564 except for bad responses and stored between 1st April 2000 to 3rd June 2011. Based on the study, the conclusions were as follows. Reliability of DSOM. For female, all pathogenic factors showed over 85% confidence level except for phlegm 82.6%. For male, all pathogenic factors showed more than 90% confidence level except two factors, phlegm(痰) indicates 87.% and damp(濕) indicates 89.8%. HH rates among pathogenic factors were more than 50 points. For female, HH rates of other 14 pathogenic factors were all over 80% except for heat(熱) 78.2% and insufficiency of Yang(陽虛) 75.3%. For male HH rates of all pathogenic factors were more than 80% except HH rates of heat 78.2% and damp 77.8%. Research based on a degree of satisfaction of reliability derived from pathogenic factors with scores of HH results in for all 16 pathogenic factors showed over 85% of relatively high level of satisfaction for both sexes whose reliability standard come under 5~4 points. Comparing appearance frequency of pathogenic factors for both sexes. Male only displays higer than female in heat(熱). Whereas female were higher than male for other 15 pathogenic factors and the difference was biggest in heart(心) and least in insufficiency of Yin(陰虛). Comparing appearance frequency order of pathogenic factors for both sexes. Female outdistanced male in blood stasis(血瘀) coldness(寒) blood-deficiency(血虛) phlegm(痰), while male outdistance female in heat(熱) insufficiency of Yin(陰虛) deficiency of qi(氣虛). Male had lower average of each pathogenic factors than female except heat(熱) as well as deficiency of qi(氣虛).

Web-enabled Healthcare System for Hypertension : Hyperlink-based Inference Approach

  • Song Yong Uk;Chae Young Moon;Ho Seung Hee;Cho Kyoung Won
    • Proceedings of the Korea Association of Information Systems Conference
    • /
    • 2003.05a
    • /
    • pp.271-285
    • /
    • 2003
  • In the conduct of this study, a web-enabled healthcare system for the management of hypertension was implemented through a hyperlink-based inference approach. The hyperlink-based inference platform implemented using the hypertext capacity of HTML which ensured accessibility, multimedia facilities, fast response, stability, ease of use and upgrade, and platform independency of expert systems. Many HTML documents, which are hyperlinked to each other based on expert rules, were uploaded beforehand to perform the hyperlink-based inference. The HTML documents were uploaded and maintained automatically by our proprietary tool called the Web-Based inference System (WeBIS) that supports a graphical user interface (GUI) for the input and edit of decision graphs. Nevertheless, the editing task of the decision graph using the GUI tool is a time consuming and tedious chore when the knowledge engineer must perform it manually. Accordingly, this research implemented an automatic generator of the decision graph for the management of hypertension. As a result, this research suggests a methodology for the development of Web-enabled healthcare systems using the hyperlink-based inference approach and, as an example, implements a Web-enabled healthcare system for hypertension, a platform which peformed especially well in the areas of speed and stability.

  • PDF

A Development of Automation System of Auto-Recognition for Device Modules using Micro-Processing Unit (MPU를 이용한 디바이스 모듈 자동 인식 자동화 시스템의 개발)

  • Lin, Chi-Ho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.5 no.3 s.11
    • /
    • pp.24-28
    • /
    • 2006
  • This paper proposed design and implementation of automation system that recognize device module boards automatically that are connected on main control board. The system of this paper is divided to main board and device module boards, and the main board is designed a board by slot structure. The slot structure is possible a extension for upgrade and addition of board ability. Besides, it is easier a establishment and disjointing because it recognizes automatically a device board. The proposed system in this paper compares with K10S1 PLC. The result shows an advantage of extensibility and ability, and it is reduced expense and period for development.

  • PDF

A Study on an Algorithm for Eliminating False Feature Points (의사 특징점 제거 알고리즘 관한 연구)

  • Jeong, Yang-Gwon;Choe, Jae-Ho
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.4
    • /
    • pp.899-907
    • /
    • 1996
  • In this paper, we proposed an algorithm to eliminate false feature points to upgrade the system ability using the cross number method. By using the proposal algorithm, it was able to extract feature points exactly and increase the recognition rates.In the experiment, we used3 groups : the uncut-partially noised, and uncut completely noised fingerprint to verify our proposal. We then compared the results of the proposed system with those of another system in which false feature points were not eliminated. We have obtained good recognition rates of 97.7%, 97.7%, and95.0% in the cut, uncut-partially noised, and the uncut-completely noised fingerprints. However, the other system received the results of the cut 60%, the uncut-partially noised 35%, and the uncut-completely noised 50% respectively. As a result, we belive that the fingerprint may be recognized after adapting the proposal algorithm.

  • PDF

A Robot Controller Development of a Large-scale System for Shipbuilding

  • Kim, Soo-Ho;Kang, Gye-Hyung;Park, Ju-Yi;Chu, Gil-Whoan;Kim, Jin-Wook;Kim, Ji-Yun;Kim, Sung-Kwun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.472-475
    • /
    • 2005
  • This paper present a robot controller developed for shipbuilding yard. Since shipbuilding process handles large work pieces and has dusty and noisy environment, the developed controller has separated architecture into main control part and servo control part. Main control part is located in control room while servo control part is located near robot with work pieces. Commutation between two parts is done through SynqNet and RS485. Air purging system is adapted to servo control part for better reliability. We aimed open architecture in both hardware and software architecture. For open hardware architecture, we employed Compact PCI (cPCI) because it is widely used bus system and very reliable. Since lots of commercial boards are available with cPCI interface, upgrade and reconfiguration is easy. For open software architecture, Windows XP�� Embedded is selected as operating system (OS), because it is very popular OS and most hardware vender supports device driver for the windows XP.

  • PDF