• Title/Summary/Keyword: system uncertainty

Search Result 2,446, Processing Time 0.028 seconds

A Study on the Quality Control and Operating System of Standard Reference Data(SRD) (참조표준데이터 품질관리 및 운영체계에 관한 연구)

  • Chae Kyun-shik;Lee Eung-Bong
    • Journal of Korean Library and Information Science Society
    • /
    • v.36 no.2
    • /
    • pp.283-305
    • /
    • 2005
  • Data produced during scientific and technical activities usually have value as standard reference data (SRD) which is a well-documented numeric value assessed for reliability and accuracy. The main criteria in the evaluation for SRD is how well their production is documented including a sample preparation, measurement method, data processing and so on, other than reference data. SRD is represented as a certified numeric value with uncertainty. In this study, the SRD in the area of material properties was introduced to provide understanding of SRD and its evaluation method. Also the national SRD system was studied. The national SRD system is composed of the center for the SRD, the data centers, and the committee. The role and task of those components were studied. The legislational and systematic supports for the system were proposed in this study.

  • PDF

The Control of Spring-Mass-Damper Convergence System using H Controller and μ-Synthesis Controller (H 제어와 μ-합성 제어를 이용한 스프링-질량-감쇠 융합시스템 제어)

  • Jung, Sunghun
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.5
    • /
    • pp.1-11
    • /
    • 2017
  • With a given spring-mass-damper system, $H_{\infty}$ and ${\mu}$-synthesis control methods are used to build system controllers which minimize vibrations at two major natural frequencies in two cases; without uncertainty; with 20% uncertainty. In order to check the stability and performance of two controllers, those are examined using GM and PM values. The signal strength of output responses is compared using the concept of central numerical differentiation and then results are quantified using the RMS method. Lastly, 40 random samples of $H_{\infty}$ and ${\mu}$-synthesis controllers are obtained for three different $W_{per\;f1}$ weighting functions and drawn in the time domain in order to compare the stability. Overall, ${\mu}$-synthesis controller manages the vibrations much better than $H_{\infty}$ controller according to the robust stability and performance values obtained by simulating random samples of 40 plant models.

Implementation on the Portable Blood Gas Analyzer and Performance Estimation/A Study on the Hydrometer Calibration System using Image Processing (영상처리 기법을 이용한 부액계 자동 교정 시스템 구현)

  • Lee, Yong-Jae;Chang, Kyung-Ho;Oh, Chae-Youn;Jung, Sang-Duk
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.258-264
    • /
    • 2003
  • The present paper studies how to calibrate hydrometer using image process. The method aligns particular scales of hydrometer selected for calibrating the hydrometer with the horizontal plane of the reference liquid automatically without man's operation. Major parts composing the system are CCD camera, frame grabber, stepping motor and image process program. The image process program is composed of a part that locates the meniscus and aligns it with a scale and a part that controls the step motor. To verify the performance of the developed method, this study compares the meniscus and scale observed directly with the naked eye with the result of calibration by the manual calibration method. The differences between the corrections were less than $0.004\;kg/m^3$ with uncertainty of $0.06\;kg/m^3$. These showed that the calibration results of the developed hydrometer calibration using image process nearly equal to manual method.

Improvement and Evaluation of Emission Formulas in UM-CMAQ-Pollen Model (UM-CMAQ-Pollen 모델의 참나무 꽃가루 배출량 산정식 개선과 예측성능 평가)

  • Kim, Tae-Hee;Seo, Yun Am;Kim, Kyu Rang;Cho, Changbum;Han, Mae Ja
    • Atmosphere
    • /
    • v.29 no.1
    • /
    • pp.1-12
    • /
    • 2019
  • For the allergy patient who needs to know the situation about the extent of pollen risk, the National Institute of Meteorological Sciences developed a pollen forecasting system based on the Community Multiscale Air Quality Modeling (CMAQ). In the old system, pollen emission from the oak was estimated just based on the airborne concentration and meteorology factors, resulted in high uncertainty. For improving the quality of current pollen forecasting system, therefore the estimation of pollen emission is now corrected based on the observation of pollen emission at the oak forest to better reflect the real emission pattern. In this study, the performance of the previous (NIMS2014) and current (NIMS2016) model system was compared using observed oak pollen concentration. Daily pollen concentrations and emissions were simulated in pollen season 2016 and accuracy of onset and end of pollen season were evaluated. In the NIMS2014 model, pollen season was longer than actual pollen season; The simulated pollen season started 6 days earlier and finished 13.25 days later than the actual pollen season. The NIMS2016 model, however, the simulated pollen season started only 1.83 days later, and finished 0.25 days later than the actual pollen season, showing the improvement to predict the temporal range of pollen events. Also, the NIMS2016 model shows better performance for the prediction of pollen concentration, while there is a still large uncertainty to capture the maximum pollen concentration at the target site. Continuous efforts to correct these problems will be required in the future.

The development of EASI-based multi-path analysis code for nuclear security system with variability extension

  • Andiwijayakusuma, Dinan;Setiadipura, Topan;Purqon, Acep;Su'ud, Zaki
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3604-3613
    • /
    • 2022
  • The Physical Protection System (PPS) plays an important role and must effectively deal with various adversary attacks in nuclear security. In specific single adversary path scenarios, we can calculate the PPS effectiveness by EASI (Estimated Adversary Sequence Interruption) through Probability of Interruption (PI) calculation. EASI uses a single value of the probability of detection (PD) and the probability of alarm communications (PC) in the PPS. In this study, we develop a multi-path analysis code based on EASI to evaluate the effectiveness of PPS. Our quantification method for PI considers the variability and uncertainty of PD and PC value by Monte Carlo simulation. We converted the 2-D scheme of the nuclear facility into an Adversary Sequence Diagram (ASD). We used ASD to find the adversary path with the lowest probability of interruption as the most vulnerable paths (MVP). We examined a hypothetical facility (Hypothetical National Nuclear Research Facility - HNNRF) to confirm our code compared with EASI. The results show that implementing the variability extension can estimate the PI value and its associated uncertainty. The multi-path analysis code allows the analyst to make it easier to assess PPS with more extensive facilities with more complex adversary paths. However, the variability of the PD value in each protection element allows a significant decrease in the PI value. The possibility of this decrease needs to be an important concern for PPS designers to determine the PD value correctly or set a higher standard for PPS performance that remains reliable.

Development of Laser Power Meter Calibration System with 12-diode Laser Sources (12개 다이오드 레이저를 활용하는 레이저 복사출력계 교정시스템 개발)

  • Kanghee Lee;Jae-Keun Yoo;In-Ho Bae;Seongchong Park;Dong-Hoon Lee
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.2
    • /
    • pp.61-70
    • /
    • 2024
  • We demonstrate a laser power meter calibration system based on 12-diode laser sources coupled to single-mode fibres in a wavelength range from 400 to 1,600 nm. In our system, three laser power controllers ensure that the output power uncertainty of all laser sources is less than 0.1% (k=2). In addition, all laser beams are adjusted to have similar beam sizes of approximately 2 mm (1/e2-width) at the measurement position to minimise unmeasured laser power on a detector. As a reference detector, we use an integrating sphere combined with silicon and indium gallium arsenide photodiodes to minimise the non-uniformity and non-linearity of responsivity. The minimum uncertainty of the calibration system is estimated to be 1.1% (k=2) for most laser wavelengths.

Performance Uncertainty Estimation of a Nonlinear Vibration System Based on a Sampling Method (샘플 추출방법에 근거한 비선형 진동계의 성능 불확실성 예측)

  • Choi, Chan-Kyu;Yoo, Hong-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.113-118
    • /
    • 2009
  • A designer regards the vibration system as a linear system. However, in real world, nonlinearity of a vibration system should exist caused by various factors like manufacturing conditions or uncertain material properties. So, properties of a spring and a damper which are consisting the vibration system have statistical distribution. Therefore, a designer needs to analyze the statistical nonlinearity in a vibration system. In this paper, $1^{st}$ Taylor series expansion method and univariate dimension reduction method apply to a performance measure of nonlinear vibration system, and compare each result. And then, merits and demerits of each method are discussed. For apply more actual problem, a performance measure population is estimated based on design variable samples like properties of spring or damper.

  • PDF

Assessing the Impact of Digital Procurement via Mobile Phone on the Agribusiness of Rural Bangladesh: A Decision-analytic Approach

  • Alam, Md. Mahbubul;Wagner, Christian
    • Agribusiness and Information Management
    • /
    • v.5 no.1
    • /
    • pp.31-41
    • /
    • 2013
  • The research assesses the impact of a digital procurement (e-purjee) system for sugarcane growers in Bangladesh. The system itself is simple, transmitting purchase orders to local farmers via SMS text notification. It replaces a traditional paper-based system fraught with low reliability and delivery delays. Applying expected value theory, and using decision tree representations to depict growers' decision-making complexity in an information-asymmetric environment, we compute outcomes for the strategies and sub-strategies of ICT vs. traditional paper-based order management from the sugarcane growers' perspective. The study results show that the digital procurement system outperforms the paper-based system by tangibly reducing growers' economic losses. The digital system also appears to benefit growers non-monetarily, because of reduced uncertainty and a higher level of perceived fairness. Sugarcane growers appear to value the non-monetary benefits even higher than the economic advantages of the e-purjee system.

  • PDF

Robust Control of Pneumatic Cylinder Driving System using Sliding Mode Controller (슬라이딩모드 제어기를 이용한 공기압 실린더 구동장치의 강인제어)

  • Jang, Ji-Seong;Han, Seung-Hun
    • Journal of Power System Engineering
    • /
    • v.21 no.6
    • /
    • pp.101-109
    • /
    • 2017
  • The pneumatic driving system has advantages such as high output power per weight and low heat generation rate. However, it is difficult to control the position because of its strong non-linearity such as large friction forces compared to driving force, and heat transfer characteristics that change during operation. Therefore, in order to achieve the control objectives, a robust controller should be designed considering modeling error and model uncertainty. In this paper, a sliding mode controller is designed to improve the position control performance of pneumatic cylinder driving system. Experimental results show that the designed controller achieves the designed control objectives even if the model of the cylinder driving system, such as the initial pressure inside the cylinder and the initial position of the piston is changed.

Design of the Calibration System for Determining the Sensitivity of Ultrasonic Transducer (초음파 변환기의 감도 교정 시스템 구성)

  • 사공성대;조문재;최봉열
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.2
    • /
    • pp.200-207
    • /
    • 1999
  • In this paper, a precise sensitivity measurement system of ultrasonic transducer in the frequency range from 1 MHz to 15 MHz, which can implement the reciprocity principle is constructed. All of the elements of this system such as the ultrasonic preamplifier, ultrasonic absorber, water tank, water degassing system, and four-axes translator and reflector are constructed. For the performance evaluation of the calibration system, a standard hydrophone precisely calibrated from PTB(Physikalisch Technische Bundesanstalt) in Germany are used. And the system parameters which affected the evaluation of the measurement accuracy and the reproducibility in various measuring conditions are considered. The measurement uncertainty of the calibration system is estimated within $\pm$ 2.0㏈.

  • PDF