A Study on Improvement of Operation Characteristics and Inspection Method of Standby Power Supply such as Emergency Induction Light using Li-ion Capacitor (리튬이온커패시터를 활용한 비상유도등 예비전원장치의 동작 특성 및 점검방법 개선에 관한 연구)

  • Jung, Jun-Chea
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.392-401
    • /
    • 2020
  • Purpose: This study analyzes the operating characteristics of a lithium ion capacitor that can be used as a standby power supply in an emergency, and determines whether the standby power supply is abnormal even by measuring the voltage using a linear proportionality characteristic during charging and discharging. The aim is to provide an experimental basis that can be done. Method: As a method for this study, first, analyze the operation principle and characteristics of the existing backup power supply and lithium ion capacitor, and then measure the voltage of the lithium ion capacitor according to the configuration and system block diagram of the induction lamp used in the experiment. We proceed with the test of the measured value of discharge power for each voltage band to check the amount of power held by the battery and the operation test experiment using induction lamps. Results: Just by checking the charging voltage using the linear proportional characteristics of lithium ion capacitors, it provides a basis for accurately inferring the effective operating time of induction lamp lamps. Conclusion: In the event of a disaster, the lithium ion capacitor is used as a spare power supply for emergency induction lamps to prevent complete discharge of emergency induction lamps, to prevent the problem of performing normal operation of the standby power supply, and to use only a simple voltage measurement to reserve power. It was intended to suggest many uses for evacuation equipment application in the future by making it possible to check whether the device is abnormal.

Development of Ultrasonic Sensor for Engine Condition Diagnosis of EDG (비상디젤발전기 엔진 상태진단 초음파 탐촉자 개발)

  • Lee, Sang-Guk;Choi, Kwang-Hee
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.31-35
    • /
    • 2013
  • The emergency AC power supply system of the nuclear power plant is designed to supply the power to the nuclear power plant at the emergency operating condition. The safety function of the diesel generator at the nuclear power plant is to supply AC electric power to the safety system whenever the preferred AC power supply is unavailable. The reliable operation of onsite standby diesel generator should be ensured by a condition monitoring system designed to maintain, monitor and forecast the reliability level of diesel generator. The purpose of this paper is to improve the existing ultrasonic sensor used for condition diagnosis of engine fuel pump and cylinder head for the accurate diagnosis in actual engine condition of emergency diesel generator(EDG). As a result of this study, we could design and develop much more reliable ultrasonic sensor than existing ones.

Design Optimization of Silicon-based Junctionless Fin-type Field-Effect Transistors for Low Standby Power Technology

  • Seo, Jae Hwa;Yuan, Heng;Kang, In Man
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1497-1502
    • /
    • 2013
  • Recently, the junctionless (JL) transistors realized by a single-type doping process have attracted attention instead of the conventional metal-oxide-semiconductor field-effect transistors (MOSFET). The JL transistor can overcome MOSFET's problems such as the thermal budget and short-channel effect. Thus, the JL transistor is considered as great alternative device for a next generation low standby power silicon system. In this paper, the JL FinFET was simulated with a three dimensional (3D) technology computer-aided design (TCAD) simulator and optimized for DC characteristics according to device dimension and doping concentration. The design variables were the fin width ($W_{fin}$), fin height ($H_{fin}$), and doping concentration ($D_{ch}$). After the optimization of DC characteristics, RF characteristics of JL FinFET were also extracted.

A complex hazards detection system based on Eco-sensors pack

  • Jang, Jaechun;Kim, Eunhee;Lim, Changmok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.10
    • /
    • pp.107-112
    • /
    • 2015
  • There are numerous hazards and toxins have been produced in many forms along with life and working environments. Nevertheless, to remove theses hazards and toxins, there are many counteracting goods manufactured, but the result is limited in specific categories. Also it costs a lot of energy waste. In this paper, we propose a model that reduce wasting energy for detecting and getting rid of the harms. It adds a multi hazards auto-detection model for user friendly include the disable. It will be controlled the minimal sensed level of the harms by individuals through the proposed model. It can conduct detecting and eliminating the harms via eco-sensors pack which is adapted in different environments. As a result, the model works to produce only essential energy to clear the hazard and toxins as soon as the harms are generated and it leads to standby power.

Design and Implementation of a Wireless Sensor Network Protocol for a Smart Power Outlet System (스마트 아웃렛 시스템을 위한 무선 센서네트워크 프로토콜 설계 및 구현)

  • Chung, Han-Su;Moon, Jung-Ho;Park, Sung-Wook;Lee, Hyung-Bong;Park, Lae-Jeong;Chung, Tae-Yun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.7 no.6
    • /
    • pp.291-300
    • /
    • 2012
  • This paper deals with the design and implementation of wireless sensor network protocol for smart power outlet system capable of fire detection, power monitoring, standby power cutoff, and home automation. The proposed protocol integrates both the CSMA and the TDMA protocols for low power consumption and good scalability. A prototype smart power outlet system employing the proposed protocol and a simple home automation network including the power outlet system have been implemented for evaluating the feasibility of the proposed protocol The result shows that the proposed protocol allows the power outlet system to be scalable with high power efficiency.

A New Agent Based Fault Tolerant IED System and Its Reliability Analysis (새로운 에이젼트 기반의 결함극복 IED시스템 및 신뢰성 분석)

  • Fan, Weizhong;Lee, Dong-Wook;Lee, Seun-Jae;Lim, Sung-Il;Han, Seung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1371-1373
    • /
    • 2005
  • Nowadays, Intelligent Electronic Devices(IED) are widely used in power system. In order to improve the selectivity, sensitivity, and reliability of the power system composed by IEDs, A new fault tolerant IED system based on agent technique is presented in this paper. in the presented system, different with existing IED systems, the redundancies are drawn out from IED devices, and compose a standby backup system. And those redundancies are not specified to a particular type of IEDs. By using the agent technique, redundancies can download agents to modify their functions to fit different types of IEDs. As a conclusion, the reliability of the presented system is estimated in this paper.

  • PDF

Implementation of Inductive Wireless Power Transfer System based on LLC Converter without Wireless Communication between Tx and Rx (Tx-Rx간 무선통신이 필요 없는 LLC 컨버터 기반 유도형 무선전력전송 시스템 구현)

  • Kim, Moon-Young;Choi, Shin-Wook;Kang, Jeong-il;Han, Jonghee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.5
    • /
    • pp.311-318
    • /
    • 2019
  • In general wireless power transfer systems (WPTSs), power transfer is controlled by the wireless communication between a transmitter (Tx) and a receiver (Rx). However, WPTS is difficult to apply in electronic products that do not have batteries, such as TVs. A WPTS with resonators based on a transformer of LLC series resonant converter is proposed in this study to eliminate wireless communication units between a Tx and an Rx. The proposed system operates at the boundary of the resonance frequency, and the required power can be stably supplied to authorized devices even though some misalignment occurs. Moreover, standby power standards for the electronic product can be satisfied.

Buck converter with new driving circuit in TV poer system (TV 전원장치에서 새로운 구동 회로에 의한 buck converter)

  • 정진국
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.3
    • /
    • pp.56-61
    • /
    • 1996
  • In this paper, new buck converter of a TV power system is presented. First, we devised a revised driving circuit for an emitter-coupled type buck converter, by which it is possible to reduce the material cost of transformers and voltage stress of power device. Secondly, we adopted a hybrid oscillation technique. When TV system is in off-stage, initial standby power which is necessary for remote controllable TV system is supplied by self-oscillating mode. Main power which is necessry in TV system bing on state is provided by an externally triggered oscillating mode. The switching frequency is synchronized to the oscillating frequency of horizontal deflection in TV, by which we can reduce picture noises and the size of power transformer. Thirdly, a simple error amplifier is inserted to the feed-back loop to keep the output voltage constant which means pulse width modulatio mode is added in driving part of power device. Finally, we showed by experiments that our proposed converter performs well enough to be close to the theoretically predicted values.

  • PDF

A Study on Smart Home Power-Control System with Power-Saving Green Adapter (전력절감 그린어뎁터를 이용한 스마트홈 전력 통제시스템)

  • Yoo, Seung-Jae;Park, Hee-Dong;Kim, Song-Gang
    • Convergence Security Journal
    • /
    • v.13 no.4
    • /
    • pp.85-92
    • /
    • 2013
  • Today we have an obligation to pass the beautiful earth and enrich people's lives to next generations. According to the keynote, governments have a lot of resources to support the smart grid policies. Also the demand of the implementation of smart home applied the concept of smart grid is increasing rapidly. But the construction of smart home is centered on a new public housing except the pre-existing house which is counted for most of more than 90% of total. In this study, we suggest the implementation solution to make smart-homelike for the pre-existing houses without additional wiring or construction. We develop the technology reducing the unnecessary standby power 800mW to 20mW drastically. If we apply this technology, by the power off of main IC the actual power depends on the consumption of minimal devise located on the AC input side. Then the standby power becomes approximately 20mW(110ac).

Effect of test-caused degradation on the unavailability of standby safety components

  • S. Parsaei;A. Pirouzmand;M.R. Nematollahi;A. Ahmadi;K. Hadad
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.526-535
    • /
    • 2024
  • This paper proposes a safety-critical standby component unavailability model that contains aging effects caused by the elapsed time from installation, component degradation due to surveillance tests, and imperfect maintenance actions. An application of the model to a Motor-Operated Valve and a Motor-Driven Pump involved in the HPIS of a VVER/1000-V446 nuclear power plant is demonstrated and compared with other existing models at component and system levels. In addition, the effects of different unavailability models are reflected in the NPP's risk criterion, i.e., core damage frequency, over five maintenance periods. The results show that, compared with other models that do not simultaneously consider the full effects of degradation and maintenance impacts, the proposed model realistically evaluates the unavailabilities of the safety-related components and the involved systems as a plant age function. Therefore, it can effectively reflect the age-dependent CDF impact of a given testing and maintenance policy in a specified time horizon.