• Title/Summary/Keyword: system separation method

Search Result 742, Processing Time 0.031 seconds

Determination of Residual Erythromycin Antibiotic in Fishery Products by Liquid Chromatography-electrospray Ionization Mass Spectrometry (LC-MS/MS를 이용한 어류 및 갑각류의 잔류 Erythromycin 항생제 분석)

  • Jo, Mi-Ra;Mok, Jong-Soo;Lee, Doo-Seog;Kim, Min-Jung;Kim, Poong-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.42 no.1
    • /
    • pp.15-19
    • /
    • 2009
  • A simple and sensitive method for erythromycin quantification by liquid chromatography electrospray mass spectrometry (LC-MS/MS) in fishery products was developed. Samples were extracted by liquid-liquid extraction using 70% acetonitrile. Lipids were removed by acetonitrile saturated hexane. LC separation was performed on a Shiseido UG C-18 column ($150\;mm{\times}2.0\;mm$ internal diameter.) with a gradient system of 0.2% acetic acid-acetonitrile containing 0.2% acetic acid as a mobile phase at flow rate of 0.2 mL/min. The mass spectrometer was operated in selected reaction monitoring with positive electro-spray interface. Transitions were monitored a m/z $734{\to}577$ and $734{\to}158$, with m/z $734{\to}577$ chosen for quantification. Recovery of erythromycin from fish and shrimp fortified at the 10 ng/mL, 50 ng/mL and 100 ng/mL were 91.6-109.4%, 84.4-111.2% and 98.8-109.6% with high precision, respectively. Limits of quantification and limits of detection of erythromycin in both fish and shrimp were 10.0 ng/mL and 1.0 ng/mL, respectively. This analysis method for erythromycin has been proposed for registration in the Korean Official Methods of Food Analysis and has been utilized for fishery products analysis by the Korea Food and Drug Adminstration and the National Fisheries Products Quality Inspection Service.

A Study on Thermo-Bed Design Development of HPT System (HPT 방식의 온열침대 디자인 개발에 관한 연구)

  • Lee, Bong-Kyu
    • Journal of the Korea Furniture Society
    • /
    • v.22 no.1
    • /
    • pp.72-81
    • /
    • 2011
  • These days, beds have been developed not as furniture to sleep in but Healthcare Furniture. The function of heating, non-electronic-waves and far-infrared rays have been added. Also, eco-friendly materials such as stone, mud, rubber and wood are combined to them together with the radiation-heating method using heat conduction through electronic coil and hot water circulation. Modern people suffer from stress and fatigue. The hot issue is "health." Focused on the health, the development of design for beds considering the influence electronic waves, anions, deep sleep and the density of toxic materials have on human bodies has become urgent. In this study, the trend, specification and efficiency of the functional health-related electronic coil technology are analyzed. Through the analysis, the environmental standards are set. According to them, technology, eco-friendly materials and additional functions for the development of the design are considered. Also, the government is promoting the IEC international standardization for the Korean traditional floor heating style beds. In preparation for that, we adopted new HPT method technology. It enables non-electronic-waves, low electricity and stable temperature maintenance control for the warm top and the cool bottom. Also, the head boards and the frames of the beds can be separated. Through this separation, the beds can be easily moved or installed. Eco-friendly materials such as Hinoki cypress wood and red clay and the existing tables function are combined to the head boards so they can be used as drawers and display shelves. If they are used as separate items, they can be used as covers. This is how we suggest the design for the heating beds.

  • PDF

Rapid Isolation of Cyanidin 3-Glucoside and Peonidin 3-Glucoside from Black Rice (Oryza sativa) Using High-Performance Countercurrent Chromatography and Reversed-Phase Column Chromatography

  • Jeon, Heejin;Choi, Janggyoo;Choi, Soo-Jung;Lee, Chang Uk;Yoon, Shin Hee;Kim, Jinwoong;Yoon, Kee Dong
    • Natural Product Sciences
    • /
    • v.21 no.1
    • /
    • pp.30-33
    • /
    • 2015
  • Anthocyanins are water soluble plant pigments which are responsible for the blue, red, pink, violet colors in several plant organs such as flowers, fruits, leaves and roots. In recent years, anthocyanin-rich foods have been favored as dietary supplements and health care products due to diverse biological activities of anthocyanins including antioxidant, anti-allergic, anti-diabetic, anti-microbial, anti-cancer and preventing cardiovascular disease. High-performance countercurrent chromatography (HPCCC) coupled with reversed-phase medium pressure liquid chromatography (RP MPLC) method was applied for the rapid and efficient isolation of cyanidin 3-glucoside (C3G) and peonidin 3-glucoside (P3G) from black rice (Oryza sativa L., Poaceae). The crude black rice extract (500 mg) was subjected to HPCCC using two-phase solvent system composed of tert-butyl methyl ether/n-butanol/ acetonitrile/0.01% trifluoroacetic acid (TBME/B/A/0.01% TFA, 1 : 3 : 1 : 5, v/v, flow rate - 4.5 mL/min, reversed phase mode) to give enriched anthocyanin extract (37.4 mg), and enriched anthocyanin extract was sequentially chromatographed on RP-MPLC to yield C3G (16.5 mg) and P3G (8.7 mg). The recovery rate and purity of isolated C3G were 76.0% and 98.2%, respectively, and those of P3G were 58.3% and 96.3%, respectively. The present study indicates that HPCCC coupled with RP-MPLC method is more rapid and efficient than multi-step conventional column chromatography for the separation of anthocyanins.

Simultaneous Quantification of Three Marker Compounds in Samultang by HPLC/DAD (HPLC-DAD를 이용한 사물탕 중 3종 성분의 동시분석법 확립)

  • Won, Jin-Bae;Ma, Jin-Yeul;Lee, Jae-Hoon;Ma, Choong-Je
    • Korean Journal of Pharmacognosy
    • /
    • v.40 no.4
    • /
    • pp.298-302
    • /
    • 2009
  • Samultang is one of traditional medicine composed of Paeonia lactiflora, Angelica gigas, Rehmannia glutinosa and Cnidium officinale. To develop simultaneous determination of paeoniflorin, decursin and 5-HMF in Samultang, a high performance liquid chromatography with diode array detector was used. To separate three marker components, Dionex $C_{18}$ column (5 ${\mu}m$, 120 ${\AA}$, 4.6 mm${\times}$150 mm) was used with a gradient elution system of water and methanol. UV wavelength of detector set at 230 nm and 280 nm. This method was validated by linearity, precision test and recovery test. Calibration curves of three standard components were showed good linear regression ($R^2$>0.9973). LOD and LOQ ranged from 0.08 ${\mu}g$/ml to 0.38 ${\mu}g$/ml and 0.25 ${\mu}g$/ml to 1.16 ${\mu}g$/ml, respectively. The relative standard deviations (RSDs) of data of the inter-day and intra-day experiments were less than 0.54% and 0.89%, respectively. The measured results of recovery test were varied from 93.36 to 107.79 with RSD values 0.01~1.45%. The established method was applied for separation of bio-conversion Samultang sample and compared with control sample.

Fluorescence Immunoassy of HDL and LDL Using Protein A LB Film

  • Choi, Jeong-Woo;Park, Jun-Hyo;Lee, Woo-Chang;Oh, Byung-Keun;Min, Jun-Hong;Lee, Won-Hong
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.6
    • /
    • pp.979-985
    • /
    • 2001
  • A fluorometric detection technique for HDL (High Density Lipoprotein) and LDL (Low Density Lipoprotein) was developed for application in a fiber-optic immunosensor using a protein A Langmuir-Blodgget (LB) film. For the fluorescence immunoassay, antibodies specific to HDL or LDL were imobilied on the protein A LB film, and a fluorescence amplification method was developed to overcome their weak fluorescence. The deposition of protein A using the LB technique was monitored using a surface pressure-are $({\pi}-A)$ curve, and the antibody immobilization of the protein A LB film was experimentally verified. The immobilized antibody was used to separate only HDL and LDL from a sample, then the fluorescence of he separated HDL or LDL was amplified. The amount of LDL or HDL was measured using the developed fiber optic fluorescence detection system. The optical properties resulting from the reaction of HDL or LDL with o-phtaldialdehyde, detection range, response time, and stability of the immunoassay were all investigated. The respective detection ranges for HDL and LDL were sufficient to diagnose the risk of coronary heart disease. The amplification step increased the sensitivity, while selective separation using the immobilized antibody led to linearity in the sensor signal. The regeneration of the antibody-immobilized substrate could produce a stable and reproducible immunosensor.

  • PDF

A study on the lip shape recognition algorithm using 3-D Model (3차원 모델을 이용한 입모양 인식 알고리즘에 관한 연구)

  • 김동수;남기환;한준희;배철수;나상동
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1998.11a
    • /
    • pp.181-185
    • /
    • 1998
  • Recently, research and developmental direction of communication system is concurrent adopting voice data and face image in speaking to provide more higher recognition rate then in the case of only voice data. Therefore, we present a method of lipreading in speech image sequence by using the 3-D facial shape model. The method use a feature information of the face image such as the opening-level of lip, the movement of jaw, and the projection height of lip. At first, we adjust the 3-D face model to speeching face image sequence. Then, to get a feature information we compute variance quantity from adjusted 3-D shape model of image sequence and use the variance quality of the adjusted 3-D model as recognition parameters. We use the intensity inclination values which obtaining from the variance in 3-D feature points as the separation of recognition units from the sequential image. After then, we use discrete HMM algorithm at recognition process, depending on multiple observation sequence which considers the variance of 3-D feature point fully. As a result of recognition experiment with the 8 Korean vowels and 2 Korean consonants, we have about 80% of recognition rate for the plosives and vowels.

  • PDF

Recent advances in the characterization and the treatment methods of effluent organic matter

  • Ray, Schindra Kumar;Truong, Hai Bang;Arshad, Zeshan;Shin, Hyun Sang;Hur, Jin
    • Membrane and Water Treatment
    • /
    • v.11 no.4
    • /
    • pp.257-274
    • /
    • 2020
  • There are many previous review articles are available to summarize either the characterization methods of effluent organic matter (EfOM) or the individual control treatment options. However, there has been no attempt made to compare in parallel the physicochemical treatment options that target the removal of EfOM from biological treatments. This review deals with the recent progress on the characterization of EfOM and the novel technologies developed for EfOM treatment. Based on the publications after 2010, the advantages and the limitations of several popularly used analytical tools are discussed for EfOM characterization, which include UV-visible and fluorescence spectroscopy, Fourier transform infrared spectroscopy (FTIR), size exclusion chromatography (SEC), and Fourier transform-ion cyclotron resonance-mass spectrometry (FT-ICR-MS). It is a recent trend to combine an SEC system with various types of detectors, because it can successfully track the chemical/functional composition of EfOM, which varies across a continuum of different molecular sizes. FT-ICR-MS is the most powerful tool to detect EfOM at molecular levels. However, it is noted that this method has rarely been utilized to understand the changes of EfOM in pre-treatment or post-treatment systems. Although membrane filtration is still the preferred method to treat EfOM before its discharge due to its high separation selectivity, the minimum requirements for additional chemicals, the ease of scaling up, and the continuous operation, recent advances in ion exchange and advanced oxidation processes are greatly noteworthy. Recent progress in the non-membrane technologies, which are based on novel materials, are expected to enhance the removal efficiency of EfOM and even make it feasible to selectively remove undesirable fractions/compounds from bulk EfOM.

Simultaneous Determination of Methylphenidate, Amphetamine and their Metabolites in Urine using Direct Injection Liquid Chromatography-Tandem Mass Spectrometry

  • Kwon, Woonyong;Suh, SungIll;In, Moon Kyo;Kim, Jin Young
    • Mass Spectrometry Letters
    • /
    • v.5 no.4
    • /
    • pp.104-109
    • /
    • 2014
  • Nonmedical use of prescription stimulants such as methylphenidate (MPH) and amphetamine (AP) by normal persons has been increased to improve cognitive functions. Due to high potential for their abuse, reliable analytical methods were required to detect these prescription stimulants in biological samples. A direct injection liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and implemented for simultaneous determination of MPH, AP and their metabolites ritalinic acid (RA) and 4-hydroxyamphetamine (HAP) in human urine. Urine sample was centrifuged and the upper layer ($100{\mu}L$) was mixed with $800{\mu}L$ of distilled water and $100{\mu}L$ of internal standards ($0.2{\mu}g/mL$ in methanol). The mixture was then directly injected into the LC-MS/MS system. The mobile phase was composed of 0.2% formic acid in distilled water (A) and acetonitrile (B). Chromatographic separation was performed by using a Capcell Pak MG-II C18 ($150mm{\times}2.0mm$ i.d., $5{\mu}m$, Shiseido) column and all analytes were eluted within 5 min. Linear least-squares regression with a 1/x weighting factor was used to generate a calibration curve and the assay was linear from 20 to 1500 ng/mL (HAP), 40-3000 ng/mL (AP and RA) and 2-150 ng/mL (MPH). The intra- and inter-day precisions were within 16.4%. The intra- and inter-day accuracies ranged from -15.6% to 10.8%. The limits of detection for all the analytes were less than 4.7 ng/mL. The suitability of the method was examined by analyzing urine samples from drug abusers.

Wave-Energy Extraction by a Compact Circular Array of Buoys (원형으로 배열된 다수 부이에 의한 파랑에너지 추출)

  • Cho, Il-Hyoung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.2
    • /
    • pp.103-111
    • /
    • 2014
  • The wave power, extracted from a circular array of small power buoys, is investigated under the potential theory. It is assumed that the buoy's radius, the draft, and the separation distance are much smaller than the water depth, the wave length, and the radius of a circular deployment area. The boundary value problem involving the macro-scale boundary condition on the mean surface covered by buoys is solved using the eigenfunction expansion method. The capture width, which is defined as the ratio of the extracted power to the wave power per unit length of the incident wave crest, is assessed for various combinations of packing ratio, radius of a circular array, and PTO damping coefficient. It is found that the circular array deployment is more effective in the viewpoint of efficiency than the single large buoy of the same total displaced volume.

High Performance Size Exclusion Chromatographic Analysis of Polymerization Products in Used Frying Oil (High Performance Size Exclusion Chromatography 를 이용한 튀김유의 중합체 분석)

  • Kim, In-Whan;Kim, Chul-Jin;Shin, Hyun-Kyung
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.33-37
    • /
    • 1990
  • A simple and rapid method, based on separation of a flying oil into monomeric, dimeric and oligomeric triglyceride by means of high performance size exclusion chromatography on Ultrastyragel column (500 A), is proposed for evaluation of the quality of used frying oil. The relative area of the monomeric triglyceride was decreased with frying time increase, however, the decrease rate was significantly reduced by treatment of a composited powder (porous rhyorite/citric acid 40/56/4). This measurement showed good linear relationship with change in polar component measurement. There were no significant differences between the slopes of regression lines in both treated and non-treated frying oil system for relationship between monomeric triglyceride and polar component. By this method, it was found that a frying oil habe to be discarded if the content monomeric triglyceride decreased to 71%, which was corresponed to 27% polar component.

  • PDF