• Title/Summary/Keyword: system resistance

Search Result 4,839, Processing Time 0.038 seconds

A Study on Resistance to the Adoption of ERP Systems (ERP 시스템에 대한 조직 구성원의 저항에 관한 연구)

  • 박경란;황경태;정덕훈
    • Journal of Information Technology Applications and Management
    • /
    • v.10 no.1
    • /
    • pp.47-59
    • /
    • 2003
  • This study analyses the level of resistance which workers have against the adoption of ERP systems and the factors affecting the resistance to the adoption of the new systems. The major results of the study include 1) about 40% of workers showed resistance to the adoption of ERP systems, and 2) all six factors (technical characteristics of ERP system, functional characteristics of ERP system, implementation approach, task changes caused by the adoption of ERP system, attitude toward change, and altitude toward organization) were proved to affect the resistance to the adoption of the ERP systems. In practice, adoption of ERP system brings significant changes to workers. In order for an organization to succeed, it is necessary to reduce the resistance of workers. Since this study is performed based on a case study, the results of the study may not be generalized. However, the results of the study may provide guidance which organizations can refer in the course of effective personnel management.

  • PDF

ANALYTICAL SIMULATION OF TRAVEL RESISTANCE OF THE RUBBER CRAWLER SYSTEM FOR FARM MACHINERY

  • Inaba, S.;Inoue, E.;Hashiguchi, K.;Matsuo, T.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.139-145
    • /
    • 2000
  • The mechanism of the inner resistance in a rubber crawler system has been investigated to reduce the power requirement (Kitano et al. 1994). The rolling resistance of the track roller, which is one of the major inner resistances, was measured for seven different vertical loads. The rolling resistance changed periodically and could be classified into three types. In case of the vertical load less than 500N, the rolling resistance was almost constant. For the vertical load greater than 500N, the maximum value of the rolling resistance increased. Further more in case of the vertical load greater than 1200N, negative resistance appeared. Analytical simulation of the travel resistance based on experimental results and static equilibrium equations derived from three-dimension mechanical model for the rubber crawler system. It was found that the simulation method was carried out to evaluate the travel resistance occurred by the rolling resistance of the track roller. The rolling resistance for each track roller arrangement and effects of the lug phase in the right and left rubber crawler could be estimated quantitatively.

  • PDF

Factors for the Intra-organizational Diffusion of Big Data Systems (조직 내 빅데이터 시스템 확산에 영향을 주는 요인에 대한 연구)

  • Park, Seungkwan;Kim, Cheong
    • Journal of Information Technology Services
    • /
    • v.18 no.2
    • /
    • pp.97-121
    • /
    • 2019
  • In this paper, factors affecting intra-organizational diffusion of Big Data systems from the perspective of the Big Data system vendors have been analyzed. In particular, the theory of resistance against innovation that exists in some form before the adoption or rejection of innovation has been focused on. In order to do that, the resistance has been divided into three categories : postponement, rejection and opposition. The variables affecting each type are also divided into four independent variables : perceived risk, innovation characteristics, user attributes, and organizational attributes. As a result of the survey, it was confirmed that the influences of each variable are different according to the type of resistance. As the strength of the resistance was increased, the influence of the trialability was increased as well. As the strength of the resistance was decreased, the satisfaction with the existing system became more influential on the resistance. The time risk and the satisfaction with the existing system were found to affect all types of resistance. From the vendor's point of view, strategic implications are presented in terms of marketing or system development for diffusion, depending on the degree of resistance of the adopter.

Conducted Emission of Inverter Power Sources for Resistance Welding

  • Mecke, H.;Dobbelin, R.;Winkler, T.;Fischer, W.
    • Journal of Power Electronics
    • /
    • v.2 no.2
    • /
    • pp.124-129
    • /
    • 2002
  • Invertigation electromagnetic emissione of inverter power sources resistance welding existing special aspects of EMI measurements in the field of resistance welding machines resulting from the power rating and operation mode of these machines have to be taken into account. The characteristics of the internal switching processes determined by the behavior of the applied power semiconductors, sunbber circuits and constructional aspect exert a great influence on the conducted emission welding inverters.

A Study of the Pre-Resistance Effects on the Optimization For Performance of the Ignition System with the Breaker Point Type (Breaker Point 型 점火裝置 性能 을 極大化하기 위한 Pre - Resistance 효果 에 對한 硏究)

  • 손병진;신영철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.6 no.2
    • /
    • pp.133-139
    • /
    • 1982
  • One of factors that affect combustion in the cylinder of the engine is to keep a greater energy in the ignition system to minimize pollutant emissions and to increase its performance of the low temperature. This paper reviews theoretically the state and input variables of the ignition system from the state transition equation. Effects on characteristics of the system such as primary current, secondary available voltage and spark duration by reducing the pre-resistance from 3.5 to 0 ohm in 12V system is experimentally investigated when the ignition coil has a primary resistance of 1.5 ohms ad the dwell angle of the breaker point is 43.2 degrees (0.75 radian). Advantages and limitations for using the low resistance of the primary circuit are also presented to optimize the performance of the ignition system with the breaker point.

A New Measurement Method of the Ground Resistance Using a Low-pass Filter in Energized Substations (지역필터를 이용한 수변전실 접지저항의 새로운 측정방법)

  • Lee, Bok-Hui;Eom, Ju-Hong;Lee, Seung-Chil;Kim, Seong-Won;An, Chang-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.387-393
    • /
    • 2001
  • This paper describes an advanced measuring method and precise evaluation of the ground resistance for the grounding system of energized substations and power equipments. A grounding system of substations consists of all interconnected grounding connections of grounded conductors, neutral ground wires, underground conductors of distribution lines, cable shields, grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding system of high voltage energized substations because of harmonic components caused by switched power supplies or overloads. The conventional fall-of-potential method may be subject to big error if stray ground currents and potentials are present. In this work, to improve the precision in measurements of the ground resistance by eliminating the effects of harmonic components and stray currents and potentials, the investigations of the ground resistance measurement by using a low pass filter in a model energized grounding system were conducted. The accuracy of ground resistance mesurements was evaluated as a function of the ratio of the test signal to noise (S/N). The errors due to the proposed ground resistance measurement method were decreased with increasing S/N and were less than 5[%] as S/N is 10. The proposed ground resistance measurement method appears to be considerably more accurate than the conventional fall-of -potential method. It is allows cancellation of the parasitic resistance of energized grounding systems, to employ the measurement method that allows cancellation of the parasitic effects due to other circulating ground currents and ground potential rises in practical situations.

  • PDF

Intelligent quality estimation system using primary circuit variables of RSW (저항점용접 1차 공정변수를 이용한 지능형 용접품질 판단 시스템)

  • 조용준;이세헌;신현일;배경민;권태용
    • Proceedings of the KWS Conference
    • /
    • 1999.10a
    • /
    • pp.142-145
    • /
    • 1999
  • The dynamic resistance monitoring is one of the important issues in that in-process and real time quality assurance of resistance spot weld is needed to increase the product reliability. Secondary dynamic resistance patterns, as a real manner, are hard to adapt those factors in real time and in-plant system. In the present study, a new dynamic resistance detecting method is presented as a practical manner of weld quality assurance at the primary circuit. By the correlation analysis, it is found that the primary dynamic resistance patterns are basically similar to those of the secondary. Various dynamic resistance indices are characterized with the primary curve. And quality of the weld, like the tensile shear strength, is estimated using adaptive neuro-fuzzy estimation system which is consisted of the Sugeno fuzzy algorithm. Through the fuzzy clustering and parameter optimization, real time weld quality assurance system with less efforts is proposed.

  • PDF

A measuring Method of Ground Resistance for Energized Power Systems (운전중인 전력설비의 접지저항 측정방법)

  • 이복희;김성원;엄주홍;이승칠
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.77-81
    • /
    • 2000
  • The purpose of this paper is to describe a new measuring method of ground resistance for the grounding system in energized power equipment and substations. It is very difficult to measure the accurate ground resistance in energized power equipment and substations because of the noise conducted from all external connections to the grounding system and harmonics components caused by unbalanced loads and overloads. The ground resistance that is measured with existing methods includes not only the effect of desired signals but also noise components for the measurement period in grounding system. The measured value of ground resistance can entirely be different from actual value. In this paper, to eliminate 60[Hz] power system interference and harmonic components the low-pass filter method was used in the measurement of ground resistance.

  • PDF

Behavior Characteristics of PCM Infilled Floor System at Elevated Temperature (고온에 노출된 PCM 충진형 바닥 시스템의 거동 특성)

  • Park, Min-Jae;Min, Jeong-Ki;Yoon, Sung-Won;Ju, Young K.
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.2
    • /
    • pp.33-41
    • /
    • 2017
  • Composite Floor system infilled with PCM(Phase Change Material) between upper and lower steel plates was developed to apply the steel frame. When steel frames were applied this system, it can absolutely reduce the duration of construction due to dry construction method. However to apply this system as a structural floor member without fire resistance covering, it must have 2 hours fire resistance performance. Because PCM consisted of three quarters of section with thermal insulation performance, fire resistance performance of this floor system was expected to easily have 2 hours fire resistance performance. This paper was to investigate behavior characteristics of PCM infilled floor system at elevated temperature using FEM analysis to develop the fire resistance performance of it.

System-level Analysis of a Fan-motor Assembly for Vacuum Cleaner (진공청소기용 팬-모터 어셈블리의 시스템-레벨 분석)

  • Park, Chang-Hwan;Park, Kyung-Hyun;Chang, Kyung-Sik
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.1
    • /
    • pp.5-14
    • /
    • 2017
  • A fan-motor assembly in a vacuum cleaner is analyzed through system-level analysis method. This system consisted of three components, a fan, motor, and the flow resistance of the motor, or of the vacuum cleaner. System-level analysis method is characterized by the combination of torque matching at a constant throttling condition between the fan and the motor and the pressure drop at a constant flow rate due to the flow resistance of the motor, or of the vacuum cleaner. The performance characteristics of the fan-motor assembly and the vacuum cleaner system could be predicted over the whole range of operation, based on the characteristics of each component. The predicted performance of the vacuum cleaner system through system-level analysis agreed well with the experimental results within 4.5% difference of pressure and 6% difference of the efficiency. The effect of flow resistance of a motor is investigated and it is found that the efficiency decrease of fan-motor assembly at the constant flow rate due to the flow resistance of a motor is determined by the flow resistance ratio(FRR), which is defined as a ratio of flow resistance of motor and the flow resistance of a constant throttling condition of a given point. The fan-motor assembly(S2 model) was modified to reduce the FRR from 9.0% to 2.4% and the experimental result shows that the efficiency of S2 model was improved by about 3% at best efficiency point.