• 제목/요약/키워드: system generator

검색결과 4,049건 처리시간 0.039초

풍력발전용 계통연계 DFIG의 출력 해석 (Power Analysis of Grid Connected Doubly Fed Induction Generator for Wind Power Generating System)

  • 이현채;서영택;오철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.326-329
    • /
    • 1997
  • This paper deals with the generating power analysis of wound rotor induction generator according to the rotor excitation for use of DFIG (Doubly Fed Induction Generator) system in wind power generation as a part of renewable energy development. In this way, the generating power of wound rotor induction generator can be achieved for a wide range wind speed of supersynchronous and subsynchronous speed.

  • PDF

전력변횐기를 가지는 동기발전기의 특성 (Characteristics of Synchronous Generator with Power Static Converter)

  • 이승원;권영안
    • 대한전기학회논문지
    • /
    • 제33권1호
    • /
    • pp.1-8
    • /
    • 1984
  • The system of synchronous generator with power static converter are analyzed in detail and the output characteristics of generator are computed by digital simulation. The power static converter is considered as 3-phase converter in which the interlude interval and the commutation interval repeats itself six times per cycle. The synchronous generator is considered as a direct-phase quantities model for a more exact study of the performance. As the numerical method for nonlinear differential equations of the system, the Runge -Kutta method is used.

  • PDF

수차발전기 상태진단시스템을 이용한 예지보전체계 (Predictive Maintenance System using Condition Monitoring System of Hydro-turbine Generator)

  • 김응태;고성호;김현;정용채;최성필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.453-456
    • /
    • 2007
  • The purpose of this study is to explain the importance of Vibration Monitoring Device by introducing an example of Predictive Maintenance System using Condition Monitoring System of Hydro-turbine generator. Confirming vibration of generation equipment is commissioning procedure during equipment completion for checking guaranteed items. Data from Generator output range are used to determine output band to continue the performance of equipment. The Vibration Monitoring System is not absolute method of maintenance, but if it is used well with expert, it will be visible, data-analyzed, scientific maintenance more than others. And also, Condition Monitoring System is very important for remote controlled small hydro-power plant although most of it is installed in Large hydro-power plant.

  • PDF

수차발전기 상태진단시스템을 이용한 예지보전체계 (Predictive Maintenance System using Condition Monitoring System of Hydro-turbine Generator)

  • 김응태;고성호;김현;정용채;최성필
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.57-60
    • /
    • 2006
  • The purpose of this study is to explain the importance of Vibration Monitoring Device by introducing an example of Predictive Maintenance System using Condition Monitoring System of Hydro-turbine generator. Confirming vibration of generation equipment is commissioning procedure during equipment completion for checking guaranteed items. Data from Generator output range are used to determine output band to continue the performance of equipment. The Vibration Monitoring System is not absolute method of maintenance, but if it is used well with expert, it will be visible, data-analyzed, scientific maintenance more than others. And also, Condition Monitoring System is very important for remote controlled small hydro-power plant although most of it is installed in Large hydro-power plant.

  • PDF

계통 안전성을 고려한 원자력발전의 부하추종 요건연구 (A Study on Requirement of Nuclear Power Plant Load Following Operation Condition Considering Power System Security)

  • 이현철;백영식;이근준
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1565-1570
    • /
    • 2012
  • Nuclear power generation is increasing domestic power supply ratio by lower CO2 emission and fuel prices. Currently, nuclear power generator has been operated with maximum power output. Therefore, nuclear power generator could be no effect to managing the reactive power reserve on power system. The reactive power reserve is calculated to the difference between maximum facility and operation generation capacity of the power system. This paper was proposed that load following of nuclear power is control by using 15-bus power system model. In the simulation result, power system is shown to safety state by operating load following of nuclear power generator. This method has be improved the supplied reliability through economic and efficient operation.

풍력발전용 유도발전기 시스템의 최적제어 (Optimal Power Control of Wind Induction Generator System)

  • 최선필;허태원;박지호;노태균;정재륜;우정인
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.69-72
    • /
    • 2002
  • In this study, We proposed high efficiency wind power generator system for induction generator used SVPWM swiching inverter. First, We propose Equivalient Circuit for Induction Generator, it's characteristics equation, and power equation of slip. In addition, we suggest Pick Power Traction Slip control methods, adapted variable wind power system. We study simulation result for the proposed system and output power by slip effect. and we identify SVPWM of suitable wind power system by comparison between SPWM and SVPWM Consequently, we show that the system control result from variable wind power is suitable.

  • PDF

수차발전기 상태진단시스템을 이용한 예지보전체계 사례 (Report on Predictive Maintenance System using Condition Monitoring System of Hydro-turbine Generator)

  • 고성호;정용채;최성필;곽영균;한승열
    • 한국유체기계학회 논문집
    • /
    • 제13권1호
    • /
    • pp.29-34
    • /
    • 2010
  • The purpose of this study is to explain the importance of Vibration Monitoring Device by introducing an example of Predictive Maintenance System using Condition Monitoring System of Hydro-turbine generator. Confirming vibration of generation equipment is commissioning procedure during equipment completion for checking guaranteed items. Data from Generator output range are used to determine output band to continue the performance of equipment. The Vibration Monitoring System is not absolute method of maintenance, but if it is used well with expert, it will be visible, data-analyzed, scientific maintenance more than others. And also, Condition Monitoring System is very important for remote controlled small hydro-power plant although most of it is installed in Large hydro-power plant.

실시간 시뮬레이터를 이용한 디젤발전기 여자시스템 현장시험 (A Field Test of Diesel Generator Excitation Control System Using Real Time Simulator)

  • 이주현;류호선;정태원
    • 전기학회논문지
    • /
    • 제59권7호
    • /
    • pp.1314-1319
    • /
    • 2010
  • The excitation control system of an emergency diesel generator is classified as a kind of safety-related system. Compared with other control systems in a power plant, this system is required to be more reliable and have better performance. KEPCO Research Institute successfully developed the excitation control system for a diesel generator. This paper presents its field test results by using a real time simulator on a nuclear power plant.

원전 증기발생기 수위제어계통의 고장검출 시스템 설계 (A Fault Detection System Design for Nuclear Steam Generator Level Control System)

  • 류석환;최병재
    • 한국지능시스템학회논문지
    • /
    • 제16권2호
    • /
    • pp.191-197
    • /
    • 2006
  • 본 논문에서는 원저 증기발생기 수위제어계통을 위한 고장검출 시스템을 설계한다. 이를 위하여 증기발생기 수위제어계통의 비선형 동적방정식을 미지의 매개변수를 갖는 T-S 퍼지시스템으로 모델링하고 좌 소인수 분해를 이용하여 오차발생기를 설계한다. 고장검출의 성능을 향상시키기 위하여 고장검출 필터의 설계법을 제안한다. 제시한 방법의 효용성을 컴퓨터 모의실험을 통하여 입증한다.

구분모드합성법을 이용한 증기터빈$\cdot$발전기축계의 진동해석 (Vibration Analysis of Steam Turbine-Generator Rotor System Using Component Mode Synthesis Method)

  • 양보석;김용한;최병근;이현
    • 소음진동
    • /
    • 제9권2호
    • /
    • pp.401-408
    • /
    • 1999
  • A method is presented for the vibration analysis of steam turbine-generator rotor system based on the component mode synthesis method. The motion of each component of the system is described by superposing constraint mode associated with boundary coordinates and constrained normal modes associated with internal coordinates. This method using real fixed-interface modes allows for significant reduction in system model size while retaining the essential dynamic characteristics of the lower modes. The capability of this method is demonstrated in the natural frequency and unbalance response analysis of the steam turbine-generator rotor system in which the dynamics of the pedestal is considered. The results by the present method are compared with finite element method and trnasfer matrix method in terms of the accuracy and computing time.

  • PDF