• Title/Summary/Keyword: synthetic spectra

Search Result 127, Processing Time 0.026 seconds

Removing Telluric Absorbtion lines for IGRINS spectra

  • Jeong, Gwanghui;Han, Inwoo;Lee, Byeong-Cheol
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.78.2-78.2
    • /
    • 2016
  • There are many telluric absorption lines which are laid on the science spectrum in ground based spectroscopic observations. In especial, the IR region spectra are considerably contaminated by telluric lines. Therefore, many scientists have a difficulty in removing the telluric effect. We thus tried removing telluric lines with IGRINS data by two methods. One is using the standard stellar spectrum as telluric lines. The other adopt calculated synthetic telluric spectrum. Here we present the results of test for precise removing telluric lines on IGRINS spectra.

  • PDF

Characterization of Synthetic Polyamides by MALDI-TOF Mass Spectrometry

  • Choi, Hae-Young;Choe, Eun-Kyung;Yang, Eun-Kyung;Jang, Sung-Woo;Park, Chan-Ryang
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.12
    • /
    • pp.2354-2358
    • /
    • 2007
  • MALDI-TOF-MS technique was applied to obtain structural and compositional information of synthetic polyamides, Nylon6 and Nylon66. Mass spectra of both the original and the hydrolyzed polyamide samples were analyzed using the self calibration method as well as the internal calibration method with the standard materials of known masses. The MALDI-TOF mass spectra of Nylon6 samples showed the presence of protonated, sodiated, and potassiated ions that were assigned to cyclic and NH2/COOH terminated linear oligomers. From the MALDI-TOF mass spectra of Nylon66 samples, the potassiated linear oligomers with three different end groups are identified as well as the cyclic oligomers, i.e., NH2/COOH terminated oligomers, NH2/NH2 terminated oligomers, and COOH/COOH terminated oligomers. Full characterization of the molecular species and end groups present in the polyamide samples has been achieved, and also the changes in mass spectral patterns after the hydrolysis of the samples are presented.

Spectroscopic Characteristics of Gemstones with Color Change Effect (변색 효과 보석들의 분광학적 특성)

  • Ahn, Yong-Kil;Seo, Jin-Gyo;Park, Jong-Wan
    • Journal of the Mineralogical Society of Korea
    • /
    • v.22 no.2
    • /
    • pp.81-86
    • /
    • 2009
  • The luminescence and fluorescence were investigated by photoluminescence spectroscopy for six gemstones which exhibit color change effect. The shape of luminescence peaks appears different when observed by a photoluminescence spectroscopewith a 514 nm Ar laser source. However, it was not possible to observe the difference in the spectra between the natural and synthetic origins for the same type of gemstones. It was found that the photoluminescence spectrum was related to the crystal structure of the stones. Photoluminescence spectra using a 325 nm He-Cd source reveal that fluorescence is relatively strong for synthetic alexandrite, synthetic color change sapphire and natural alexandrite comparing to the rest of gemstones examined.

Site specific ground motion simulation and seismic response analysis for microzonation of Kolkata

  • Roy, Narayan;Sahu, R.B.
    • Geomechanics and Engineering
    • /
    • v.4 no.1
    • /
    • pp.1-18
    • /
    • 2012
  • The spatial variation of ground motion in Kolkata Metropolitan District (KMD) has been estimated by generating synthetic ground motion considering the point source model coupled with site response analysis. The most vulnerable source was identified from regional seismotectonic map for an area of about 350 km radius around Kolkata. The rock level acceleration time histories at 121 borehole locations in Kolkata for the vulnerable source, Eocene Hinge Zone, due to maximum credible earthquake (MCE) moment magnitude 6.2 were generated by synthetic ground motion model. Soil investigation data of 121 boreholes were collected from the report of Soil Data Bank Project, Jadavpur University, Kolkata. Surface level ground motion parameters were determined using SHAKE2000 software. The results are presented in the form of peak ground acceleration (PGA) at rock level and ground surface, amplification factor, and the response spectra at the ground surface for frequency 1.5 Hz, 3 Hz, 5 Hz and 10 Hz and 5% damping ratio. Site response study shows higher PGA in comparison with rock level acceleration. Maximum amplification in some portion in KMD area is found to be as high as 3.0 times compared to rock level.

Comparison of Matrices for Optimal Analysis of Synthetic Polymers Using MALDI-TOF Mass Spectrometry

  • Yoo, Hee-Jin;Kim, Duck-Hyun;Choi, Yoon-Ji;Choi, Jung Hoon;Park, Moonhee;Shin, DongJin;Oh, YoonSeok;Kim, YangSun;Cho, Kun
    • Mass Spectrometry Letters
    • /
    • v.11 no.4
    • /
    • pp.77-81
    • /
    • 2020
  • Characterization of the various chemical aspects of composite polymers is important for quality control of manufactured polymers. In this study, we compared three suitable matrices (α cyano-4-hydroxycinnamic acid [CHCA], 2,5 dihydroxy benzoic acid [2,5-DHB], and dithranol), to characterize various synthetic polymers by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Although the spectra obtained with the CHCA and 2,5-DHB matrices were generally good, in certain samples ghost peaks disappeared only when dithranol was used as the matrix. Furthermore, we examined the use of sodium trifluoroacetate (NaTFA) as an additive to reduce interference by metals and copolymers in the spectra. In conclusion, appropriate selection of a matrix, according to the characteristics of the polymer, and the use of additives to improve sensitivity are important considerations for polymer analysis and development.

Structure studies of Pulmonary Surfactant Protein B(SP-B(3,4)) by NMR Spectroscopy and Molecular Modeling

  • Kim, Yangmee;Dongha Baek;Kang, Joo-Hyun;Shin, Song-Yub;Hahm, Kyung-Soo
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.5 no.1
    • /
    • pp.37-45
    • /
    • 2001
  • Synthetic pulmonary surfactants consisting of a mixture of phospholipids with synthetic peptides based on human surfactant-associated protein SP-B were prepared. These surfactants were analyzed f3r their secondary structures by circular dichroism (CD) spectroscopy and NMR spectroscopy. Two synthetic peptides (SP-B(3), SP-B(4)) combined with the phospholipid mixture displayed significant surfactant properties. The CD spectra showed that the u-helical propensities of the peptides in DPC micelles. In the NMR spectroscopy, the tertiary structures of SP-B(3) show that it has $\alpha$-helical structure from Gln5 to Arg13 in DPC micelle and SP-B(4) show that they have $\alpha$-helical structure from Gln5 to Leu12 in DPC micelle. Based on these structures, truncated peptides originated from SP-B protein, can be designed as effective synthetic surfactants for clinical use.

  • PDF

Characteristics of gem-quality synthetic diamond from New Diamond Technology in Russia (러시아의 뉴 다이아몬드 테크놀러지에서 생산된 보석용 합성 다이아몬드의 특성)

  • Choi, Hyunmin;Kim, Youngchool
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.25 no.5
    • /
    • pp.188-192
    • /
    • 2015
  • Gemological and spectroscopic properties of HPHT synthetic diamonds from New Diamond Technology (NDT) company in St. Petersburg (Russia) were examined. Their color (colorless, near-colorless with some boron and Fancy blue with high boron content) and clarity ($VVS-SI_1$) grades were comparable to those of top natural diamonds. NDT synthetic diamonds fluoresced and phosphoresced blue or orange under SWUV light. Photoluminescence spectra revealed H3 center with very small intensity and NV centers. The intensity of H3 in NDT synthetic diamond has very weak in comparison with natural one. Using a combination of gemological and spectroscopic tests, gem-quality synthetic diamonds from NDT can be distinguished from natural diamonds of similar quality.

Gas Temperature Measurement in Supersonic Flows by N2+ Emission Spectroscopy (질소 이온 발광 분광법을 이용한 초음속 유동의 기체 온도 측정)

  • Shin, Ji-Chul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.3
    • /
    • pp.245-250
    • /
    • 2010
  • The procedure for estimating the gas (rotational) temperature of an air discharge in supersonic flows is presented in detail. Since direct measurement of the temperature in a supersonic flow is difficult, a nonintrusive measurement was performed by optical emission spectroscopy based on the emission spectra of nitrogen molecular ions. A detailed explanation, including the equations for emission line intensity, is presented in order to understand the structure of the emission spectra of nitrogen molecular ions. Using the obtained representation for emission spectrum, a synthetic spectrum of the first negative system of $N_2^+$ is obtained, and it is compared with the experimentally measured spectrum. Within a relative error of approximately 6.8% for the overall band spectra, the synthetic and measured spectra agree well. In the case of a 25-mA DC air discharge in a supersonic (Mach 3) flow, the gas temperature profile shows an approximately linear variation and a peak temperature of approximately 350 K.

Hydrolytic Degradation of Synthetic Polytrimethylene Terephthalate and Characterization by MALDI-TOF Mass Spectrometry

  • Yang, Eun-Kyung;Jang, Sung-Woo;Cho, Young-Dal;Choe, Eun-Kyung;Park, Chan-Ryang
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.477-482
    • /
    • 2011
  • The structural analysis of polytrimethylene terephthalate (PTT) and characterization of the hydrolytic degradation products after acid hydrolysis were performed using MALDI-TOF mass spectrometry. Mass spectra of the PTT samples were analyzed using a self-calibration method as well as an internal calibration method with standard materials of known masses. PTT structures constituting the samples were determined from the analyses of the spectra, and their relative compositions were estimated. The MALDI-TOF mass spectra of the acid-hydrolyzed PTT sample showed three main series of oligomer products with different end groups in accordance with the hydrolysis schemes. From the spectra of both $Na^+$ and $K^+$ adducts, it was concluded that the PTT samples have higher affinity for $Na^+$ compared with $K^+$ and therefore show higher ionization efficiency with sodium ions when dithranol is used as a matrix. Two different wavelength laser beams ($\lambda$ = 337 nm and 355 nm) were tested and it was observed that the 355 nm beam was more efficient in obtaining the MALDI spectra of PTT using dithranol as a matrix under our experimental conditions.