• Title/Summary/Keyword: synthetic bone material

Search Result 53, Processing Time 0.031 seconds

New bone formation in the maxillary sinus without bone grafts:Covering of lateral window with non-resorbable membrane or bony window (골이식재를 사용하지 않은 상악동 거상술:골창의 패쇄방법에 따른 치험례)

  • Son, Dong-Seok;Lee, Ji-Su;An, Mi-Ra;Sin, Hong-In
    • The Journal of the Korean dental association
    • /
    • v.46 no.4
    • /
    • pp.222-231
    • /
    • 2008
  • Various maxillary sinus floor augmentation techniques were common performed and in the most cases, many kinds of bone graft materials were used. The graft materials are autogenous bone or other biomaterials of human, animal or synthetic origin. But these cases report describes a new surgical technique by which dental implants are inserted in a void space created by elevating the sinus membrane without additional graft material in atrophic posterior maxilla. We created lateral bony window using piezoelectric device and elevated the schneiderian membrane in five patients and was repositioned with bony window in five patients, without any bone graft. From the clinical and histological results, it is found there is potential capacity for bone formation and placement of implants in the maxillary sinus without the use of bone grafts or bone substitutes.

  • PDF

Maxillary sinus augmentation with biphasic calcium phosphate(Osteon$^{(R)}$); A clinical and radiographic study (Original Article 1 - 합성골 이식재인 Osteon$^{(R)}$을 이용한 상악동 거상술-임상적, 방사선 계측학적 연구)

  • Cha, Jae-Kook;Jung, Ui-Won;Kim, Min-Soo;Um, Yoo-Jung;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho;Chung, Sung-Min
    • The Journal of the Korean dental association
    • /
    • v.48 no.1
    • /
    • pp.45-55
    • /
    • 2010
  • Purpose: The aim of this study was to evaluate 1 year cumulative survival rate of implants placed on augmented sinus using Osteon$^{(R)}$, bone graft material and to assess height of the grafted material radiographically. Material and Methods: 10 maxillary sinuses were augmented in 10 patients and 25 implant fixtures were installed simultaneously or after 6 months healing period. The height of the sinus graft material was measured using panoramic images immediately after augmentation and up to 19 months subsequently. Changes in the height of the sinus graft material were calculated with respect to implant length and original sinus wall height. Results: The cumulative survival rate was 100% in all 25 implants. Additionally, normal healing process without any complication was observed in all patients. The mean crown/Implant ratio was 1.25. The mean marginal bone loss was 0.95mm and the mean resorption rate of Osteon$^{(R)}$ was 0.05mm/month. The fastest resorption site of Osteon$^{(R)}$ is the first molar area. The grafted material was well maintained in sinus and decreased slightly over 1 year. Conclusion: In conclusion, It can be suggested that Osteon$^{(R)}$ may have predictable result when it was used as a grafting material for sinus floor augmentation.

The Effect of $\beta$-Tricalcium Phosphate and Deproteinized Bovine Bone on Bone Formation in the Defects of Rat Calvaria (흰쥐 두개골 결손부에서 베타-트리칼슘 인산염과 탈단백우골의 골형성 효과)

  • Jung, Seung-Gon;Park, Hong-Ju;Ryu, Sun-Youl
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.4
    • /
    • pp.313-323
    • /
    • 2010
  • Purpose: This study was conducted to evaluate the effect of beta-tricalcium phosphate (Cerasorb$^{(R)}$, Germany) and deproteinized bovine bone (Bio-Oss$^{(R)}$, Switzerland) grafted to the defect of rat calvaria artificially created and the effect of use of absorbable membrane (BioMesh$^{(R)}$, Korea) on new bone formation. Materials and Methods: Transosseous circular calvarial defects with diameters of 5 mm were prepared in the both parietal bone of 30 rats. In the control group I, no specific treatment was done on the defects. In the control group II, the defects were covered with absorbable membrane. In the experimental group I, deproteinized bovine bone was grafted without absorbable membrane; in the experimental group II, deproteinized bovine bone was grafted with absorbable membrane; in the experimental group III, beta-tricalcium phosphate was grafted without absorbable membrane; in the experimental group IV, beta-tricalcium phosphate was grafted with absorbable membrane. The animals were sacrificed after 3 weeks and 6 weeks respectively, and histologic and histomorphometric evaluations were performed. Results: Compare to the control groups, the experimental groups showed more newly formed bone. Between the experimental groups, beta-tricalcium phosphate showed more resorption than deproteinized bovine bone. Stabilization of grafted material and interception of the soft tissue invasion was observed in the specimen treated with membrane. There was no statistical difference between the experimental group I, III and experimental group II, IV classified by graft material, but statistically significant increase in the amount of newly formed bone was observed in the experimental group I, II and II, IV classified by the use of membrane (P<0.05). Conclusion: Both beta-tricalcium phosphate and deproteinized bovine bone showed similar osteoconductibility, but beta-tricalcium phosphate is thought to be closer to ideal synthetic graft material because it showed higher resorption rate in vivo. Increased new bone formation can be expected in bone graft with use of membrane.

Risk Factor Analysis of Cryopreserved Autologous Bone Flap Resorption in Adult Patients Undergoing Cranioplasty with Volumetry Measurement Using Conventional Statistics and Machine-Learning Technique

  • Yohan Son;Jaewoo Chung
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.1
    • /
    • pp.103-114
    • /
    • 2024
  • Objective : Decompressive craniectomy (DC) with duroplasty is one of the common surgical treatments for life-threatening increased intracranial pressure (ICP). Once ICP is controlled, cranioplasty (CP) with reinsertion of the cryopreserved autologous bone flap or a synthetic implant is considered for protection and esthetics. Although with the risk of autologous bone flap resorption (BFR), cryopreserved autologous bone flap for CP is one of the important material due to its cost effectiveness. In this article, we performed conventional statistical analysis and the machine learning technique understand the risk factors for BFR. Methods : Patients aged >18 years who underwent autologous bone CP between January 2015 and December 2021 were reviewed. Demographic data, medical records, and volumetric measurements of the autologous bone flap volume from 94 patients were collected. BFR was defined with absolute quantitative method (BFR-A) and relative quantitative method (BFR%). Conventional statistical analysis and random forest with hyper-ensemble approach (RF with HEA) was performed. And overlapped partial dependence plots (PDP) were generated. Results : Conventional statistical analysis showed that only the initial autologous bone flap volume was statistically significant on BFR-A. RF with HEA showed that the initial autologous bone flap volume, interval between DC and CP, and bone quality were the factors with most contribution to BFR-A, while, trauma, bone quality, and initial autologous bone flap volume were the factors with most contribution to BFR%. Overlapped PDPs of the initial autologous bone flap volume on the BRF-A crossed at approximately 60 mL, and a relatively clear separation was found between the non-BFR and BFR groups. Therefore, the initial autologous bone flap of over 60 mL could be a possible risk factor for BFR. Conclusion : From the present study, BFR in patients who underwent CP with autologous bone flap might be inevitable. However, the degree of BFR may differ from one to another. Therefore, considering artificial bone flaps as implants for patients with large DC could be reasonable. Still, the risk factors for BFR are not clearly understood. Therefore, chronological analysis and pathophysiologic studies are needed.

A study of the clinical effects of various bone graft materials (다양한 골 이식재의 임상 효과에 대한 고찰)

  • Lee, Seung-Bum;Yon, Je-Young;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Lee, Yong-Geun;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.719-732
    • /
    • 2007
  • Purpose: Various bone graft materials are being used for periodontal tissue regeneration. Th materials are being developed continuously for ideal clinical effects. Therefore, it is necessary to identify the clinical characteristics of each bone graft material through comparing the various bone graft materials statistically and in doing so, proposing a more efficient bone graft material. In this study, the following results were attained through comparing the clinical effects among the bone graft materials, using the statistical method based on the clinical studies published at the department of periodontology of Yonsei hospital. Materials and Method: 6 selected studies of department of Periodontology at Yonsei University Hospital were based on clinical study of bone grafting in intrabony defects. It was compared the clinical parameters among the 6 clinical studies, using the statistical META analysis. Result: When comparing the probing depth reduction, there was a relatively great amount of decease when using the xenograft, Anorganic Bovine Derived Hydroxapatite Bone Matrix/Cell Binding Peptide(ABM/P-15: PepGen $P-15^{(R)}$) and the autogenous bone and absorbable membrane, d, 1-alctide/glycolide copolymer(GC: $Biomesh^{(R)}$). The allogfrafts showed a relatively low decrease in the probing depth and clinical attachment change. It also showed a slight decrease in the bone probing depth. The allografts showed various results according to different bone graft materials. When comparing the ABM/P-15 and bovine bone $powder(BBP^{(R)})$, ABM/P-15 showed a relatively high clinical attachment level and the bovine bone powder showed a relatively high clinical attachment level. The probing depth change and gingival recession change showed a lower value than the mean value between the two bone graft materials. The synthetic bone showed a relatively high decrease in clinical attachment level and periodontal probing depth change. There was a relatively larger amount of gingival recession when using Bioactive Glass(BG) but a relatively low bone regeneration effect was seen. Conclusion: Good restorative results of the periodontal tissue can be attained by applying the various bone graft materials being used today after identifying the accurate clinical effects.

Comparative study on the cellular activities of osteoblast-like cells and new bone formation of anorganic bone mineral coated with tetra-cell adhesion molecules and synthetic cell binding peptide

  • Yu, Hyeon-Seok;Noh, Woo-Chang;Park, Jin-Woo;Lee, Jae-Mok;Yang, Dong-Jun;Park, Kwang-Bum;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.6
    • /
    • pp.293-301
    • /
    • 2011
  • Purpose: We have previously reported that tetra-cell adhesion molecule (T-CAM) markedly enhanced the differentiation of osteoblast-like cells grown on anorganic bone mineral (ABM). T-CAM comprises recombinant peptides containing the Arg- Gly-Asp (RGD) sequence in the tenth type III domain, Pro-His-Ser-Arg-Asn (PHSRN) sequence in the ninth type III domain of fibronectin (FN), and the Glu-Pro-Asp-Ilu-Met (EPDIM) and Tyr-His (YH) sequence in the fourth fas-1 domain of ${\beta}$ig-h3. Therefore, the purpose of this study was to evaluate the cellular activity of osteoblast-like cells and the new bone formation on ABM coated with T-CAM, while comparing the results with those of synthetic cell binding peptide (PepGen P-15). Methods: To analyze the cell viability, 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay was performed, andto analyze gene expression, northernblot was performed. Mineral nodule formations were evaluated using alizarin red stain. The new bone formations of each group were evaluated using histologic observation and histomorphometrc analysis. Results: Expression of alkaline phosphatase mRNA was similar in all groups on days 10 and 20. The highest expression of osteopontin mRNA was observed in the group cultured with ABM/P-15, followed by those with ABM/T-CAM and ABM on days 20 and 30. Little difference was seen in the level of expression of collagen type I mRNA on the ABM, ABM/T-CAM, and ABM/P-15 cultured on day 20. There were similar growth and proliferation patterns for the ABM/T-CAM and ABM/P-15. The halo of red stain consistent with $Ca^{2+}$ deposition was wider and denser around ABM/T-CAM and ABM/P-15 particles than around the ABM particles. The ABM/T-CAM group seemed to have bone forming bioactivity similar to that of ABM/P-15. A complete bony bridge was seen in two thirds of the defects in the ABM/T-CAM and ABM/P-15 groups. Conclusions: ABM/T-CAM, which seemed to have bone forming bioactivity similar to ABM/P-15, was considered to serve as effective tissue-engineered bone graft material.

Skull Reconstruction with Custom Made Three-Dimensional Titanium Implant

  • Cho, Hyung Rok;Roh, Tae Suk;Shim, Kyu Won;Kim, Yong Oock;Lew, Dae Hyun;Yun, In Sik
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.1
    • /
    • pp.11-16
    • /
    • 2015
  • Background: Source material used to fill calvarial defects includes autologous bones and synthetic alternatives. While autologous bone is preferable to synthetic material, autologous reconstruction is not always feasible due to defect size, unacceptable donor-site morbidity, and other issues. Today, advanced three-dimensional (3D) printing techniques allow for fabrication of titanium implants customized to the exact need of individual patients with calvarial defects. In this report, we present three cases of calvarial reconstructions using 3D-printed porous titanium implants. Methods: From 2013 through 2014, three calvarial defects were repaired using custom-made 3D porous titanium implants. The defects were due either to traumatic subdural hematoma or to meningioma and were located in parieto-occipital, fronto-temporo-parietal, and parieto-temporal areas. The implants were prepared using individual 3D computed tomography (CT) data, Mimics software, and an electron beam melting machine. For each patient, several designs of the implant were evaluated against 3D-printed skull models. All three cases had a custom-made 3D porous titanium implant laid on the defect and rigid fixation was done with 8 mm screws. Results: The custom-made 3D implants fit each patient's skull defect precisely without any dead space. The operative site healed without any specific complications. Postoperative CTs revealed the implants to be in correct position. Conclusion: An autologous graft is not a feasible option in the reconstruction of large calvarial defects. Ideally, synthetic materials for calvarial reconstruction should be easily applicable, durable, and strong. In these aspects, a 3D titanium implant can be an optimal source material in calvarial reconstruction.

The Bone Formation Potency on the Titanium Cap According to the Pore on the Rabbit Calvarium (가토의 두개골에서 Pore의 유무에 따른 티타늄 반구에서의 골형성 능)

  • Park, Jung-Pyo;Oh, Chul-Jung;Jung, Seunggon;Park, Hong-Ju;Oh, Hee-Kyun;Ryu, Sun-Youl;Kook, Min-Suk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.1
    • /
    • pp.18-24
    • /
    • 2013
  • Purpose: This study is performed to determine the effects of titanium cap with various sizes of pores on bone formation during guided bone regeneration (GBR). Methods: Calvaria from 10 adult male rabbits were chosen as the recipient sites. A trephine bur with a diameter of 10 mm was used to form one round groove on each side of sagittal suture of the cranium, and a round bur with a diameter of 1.5 mm was used to form 6 small holes on the inner circles of round grooves to induce bleeding. In the control group, bone graft was not conducted, and closed titanium cap was fixed in the round groove. Bone graft was not performed in groups 1 and 2, but fixed on titanium caps with 0.2 mm, and 0.5 mm sized pores, respectively. For groups 3, 4, and 5, a synthetic bone graft material (${\beta}$-tricalcium phosphate, Cerasorb$^{(R)}$, Germany) was transplanted, and titanium caps without pore, with 0.2 mm and 0.5 mm sized pore were fixed, respectively. The animals were sacrificed 4 weeks after, and clinical, radiographical, and histomorphometrical evaluation of bone regeneration was performed. Results: In all groups, there were no clinical signs of infection, inflammation or wound dehiscence. Radiographic evaluation revealed well-defined semi-circular radiopacity inside the titanium cap of groups 3, 4, and 5. Histologically, the inner surface of the hemisphere was evenly lined with newly formed bone tissue, as well as grafted bone material in the group 3. In groups 4 and 5, the insertion of connective tissue was observed along the inner surface. However, the overall surface area between the grafts with different holes yielded no statistical significance in the histomorphometrical evaluation. Conclusion: Although the total area of newly formed bone showed no significant difference, excellent bone formation tendency was observed histologically when closed caps were used with bone graft was accompanied.

Effect of Keratin-Based Biocomposite Hydrogels as a RhBMP-2 Carrier in Calvarial Bone Defects Mouse Model

  • Jongjin, Lee;Jinsu, Kang;Jaewon, Seol;Namsoo, Kim;Suyoung, Heo
    • Journal of Veterinary Clinics
    • /
    • v.39 no.6
    • /
    • pp.302-310
    • /
    • 2022
  • Recently, in human medicine and veterinary medicine, interest in synthetic bone graft is increasing. Among them, bone morphogenic protein (BMP) is currently being actively researched and applied to clinical trials. However, BMP has the disadvantage of being expensive and easily absorbed into surrounding tissues. Therefore, BMP requires the use of small amounts and rhBMP (recombinant human bone morphogenetic protein)-2 carriers that can be released slowly. Hydrogel has the property of swelling a large amount of water inside when it is aqueous solution, and when it is, it consists of more than 90 percent water. Using these properties, hydrogels are often used as rhBMP-2 carrier. The scaffold used in this study is a hydrogel made from which keratin is extracted using human hair and based on it. In this study, we wanted to see the effect of bone formation in the calvarial defect model by using keratin-based hydrogel made with human hair as a scaffold. The experiment was conducted by dividing 3 groups a total of 12 mice. Calvarial bone defect is set to all 4 mm diameters. Bone formation was evaluated by using gross evaluation, micro-computed tomography (micro-CT), immunohistochemistry. Groups using keratin-based hydrogel were significantly observed compared to Group 1s, and the most bone formations were found when rhBMP-2 and hydrogel were used. This represents the superiority of the functions of the rhBMP-2 carrier by a new material, keratin-based hydrogel. Through gross evaluation, micro-CT, and immunohistochemistry, we can confirm that keratin-based hydrogel is a useful rhBMP-2 carrier.

Comparison Study of the Use of Absorbable and Nonabsorbable Materials as Internal Splints after Closed Reduction for Nasal Bone Fracture

  • Yi, Chang Ryul;Kim, Young Joon;Kim, Hoon;Nam, Sang Hyun;Choi, Young Woong
    • Archives of Plastic Surgery
    • /
    • v.41 no.4
    • /
    • pp.350-354
    • /
    • 2014
  • Background The authors sought to compare the use of the nonabsorbable polyvinyl alcohol sponge (PVA, Merocel) and absorbable synthetic polyurethane foam (SPF, Nasopore Forte plus) as intranasal splints after closed reduction of fractured nasal bones during the hospitalization period. Methods The medical records of 111 patients who underwent closed reduction for nasal bone fracture at Sanggye Paik Hospital, Inje University College of Medicine, from 2012 to 2013 were reviewed retrospectively. PVA (group A) or SPF (group B) was packed as an internal splint after closed reduction. The efficacy of the materials was compared and statistically analyzed. Results PVA was used in 82 patients, and SPF was used in 29 patients. The patients in group B complained significantly more of nasal pain on the first day after operation than the patients in group A. Headaches on the operation day were significantly more painful in group B than in group A. Bleeding on the fourth postoperative day was significantly reduced in group B as compared to group A. The patients in group B exhibited significantly more intensive nasal obstruction on the operation day and the following day than the patients in group A. However, on the third and fourth postoperative days, the nasal obstruction in group B was less than that in group A. The pain and bleeding related to the packing material was significantly reduced in group B as compared to group A. Conclusions The use of SPF as an absorbable packing material is a reasonable substitute for the traditional nonabsorbable material.