• Title/Summary/Keyword: synchronous operation

Search Result 549, Processing Time 0.025 seconds

Dynamic Characteristics Analysis on the Synchronous Motor for Propulsion System of KTX High Speed Train (KTX 고속전철 추진제어시스템의 동기전동기 구동 동작특성 분석)

  • Yoon, Cha-Jung;Park, Sang-Woon;Lee, Eun-Kyu
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3007-3018
    • /
    • 2011
  • This paper describes how to apply to commutate of thyristor efficiently. Thyristor is used for the high power system, as the research to secure domestic technology of the Current Source Inverter(CSI) for the synchronous motor operation which is used for the propulsion system of KTX. It has been composed to be available for the stable switching operation of the thyristor by supplementing problem of load commutation method, according to small Counter ElectricMotive Force(EMF) at low speed area of synchronous motor, via auxiliary commutation circuit using forced commutation method. We also have verified through the simulation using the Matlab.

  • PDF

The Characteristic Analysis of the Ag/Bi-2223 Tape and the Flux damper in GTS Synchronous Motor through 3-Dimensional Magnetic Field Analysis Using F.E.M (3차원 자계분포해석을 이용한 고온초전도동기모터에서의 Ag/Bi-2223 Tape 및 Flux Damper의 특성해석)

  • 송명곤;윤용수;이상진;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.170-172
    • /
    • 2000
  • This paper deals with the characteristic analysis of the flux damper with respect to the load, and the stability of Ag/Bi-2223 tapes in a high-Tc superconducting (HTS) synchronous motor. To find out the magnetic field distribution in a detailed model of the actual motor, the experimentally measured currents of the armature and the field windings are used as input parameters. The simulation results show that the flux damper shields the time varying field up to 10%, reduces armature reactance during the motor operation and during load changes, improving the stable motor operation. And it was observed that the flux damper generates loss by means of leakage flux, but this is not significant and it doesn't degrade the performance of the TS synchronous motor.

  • PDF

Performance of Double Fed Induction Machine at Sub- and Super-Synchronous Speed in Wind Energy Conversion System

  • Eskander, Mona N.;Saleh, Mahmoud A.;El-Hagry, Mohsen M.T.
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.575-581
    • /
    • 2009
  • In this paper two modes of operating a wound rotor induction machine as a generator at sub-and super-synchronous speeds in wind energy conversion systems are investigated. In the first mode, known as double fed induction generator (DFIG), the rotor circuit is fed from the ac mains via a controlled rectifier and a forced commutated inverter. Adjusting the applied rotor voltage magnitude and phase leads to machine operation as a generator at sub-synchronous speeds. In the second mode, the machine is operated in a slip recovery scheme where the slip energy is fed back to the ac mains via a rectifier and line commutated inverter. This mode is described as double output induction generator (DOIG) leading to increase the efficiency of the wind-to electrical energy conversion system. Simulated results of both modes are presented. Experimental verification of the simulated results are presented for the DOIG mode of operation, showing larger amount of power captured and better power factor when compared to conventional induction generators.

A study on Permanent Magnet Synchronous Servo Motor Control (영구자석 동기 서보 전동기의 제어에 관한 연구)

  • Kim, J.K.;Choi, U.D.;Jung, M.K.;Lee, H.S.;Kim, M.C.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.543-547
    • /
    • 1991
  • This paper illustrates maximum torque per ampare radio operation and efficiency operation, which are prevalently applied to the control of permanent magnet synchronous motor(PMSM). Maximum torque per ampare ratio operation minimizes the copper loss of PMSM and maximum efficiency operation minimizes the total loss of PMSM. To verify the difference of these method, simulation and experiment results applied to IPMSM(Interior type PMSM) and SPMSM(Surface mounted PMSM) are presented.

  • PDF

Maximum Torque Operation of Interior Permanent Magnet Synchronous Motor in Flux-Weakening Control

  • Kim, Jan-Mok;Rhew, Hong-Woo;Kwon, Jung-Lock;Sul, Seung-Ki
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.1
    • /
    • pp.103-109
    • /
    • 1998
  • A new flux-weakening scheme for an Interior Permanent Magnet Synchronous Motor (IPMSM) is proposed. This control scheme enables the maximum torque operation for the fast acceleration in the constant power region according to the current and voltage limit condition. Especially the dynamic performance of the braking in the flux-weakening region is improved with the compensation of the stator resistance. Also since the onset of the flux weakening operation is adjusted according to the load conditions, the machine parameters, and whether motoring or braking region, the stable and precise transition operation into or out of the flux weakening region can be achieved. The effectiveness of the proposed scheme is verified through experiments with an IPMSM drive system.

  • PDF

PMSM Sensorless Operation for High Variable Speed Compressor (고속압축기 구동 PMSM을 위한 센서리스 운전)

  • 석줄기;이동춘;황준현
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.12
    • /
    • pp.676-681
    • /
    • 2002
  • This paper presents the implementation and experimental investigation of sensorless speed control for a variable-speed PMSM(Permanent Magnet Synchronous Motor) in super-high speed compressor operation. The proposed control scheme consists of two different sensorless algorithms to guarantee the reliable starting operation in low speed region and full torque characteristics using the vector control in high speed region. An automatic switching technique between two control modes is proposed to minimize the speed and torque pulsation during the switching instant of control mode. A testing system of 3.3㎾ PMSM has been built and 90% load test results at 7000r/min are presented to examine the feasibility of proposed sensorless control scheme.

Dynamic model and simulation of microturbine generation system for islanding mode operation (마이크로터빈발전시스템 독립운전을 위한 동적 모델링 및 시뮬레이션)

  • Hong, Won-Pyo;Cho, Jea-Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.453-457
    • /
    • 2009
  • Distributed Generation (DG) is predicted to play a important role in electric power system in the near future. insertion of DG system into existing distribution network has great impact on real-time system operation and planning. It is widely accepted that micro turbine generation (MTG) systems are currently attracting lot of attention to meet customers need in the distributed power generation market. In order to investigate the performance of MT generation systems, their efficient modeling is required. This paper presents the modeling and simulation of a MT generation system suitable for isolated operation. The system comprises of a Permanent magnet synchronous generator driven by a MT. A brief description of the overall system is given, and mathematical models for the MT and permanent magnet synchronous generator are presented. Also, the use of power electronics in conditioning the power output of the generating system is demonstrated. Simulation studies with MATLAB/Simulink have been carried out in islanding operation mode of a DG system.

  • PDF

Maximum Torque Operation of a PM Synchronous Motor for HEV under Parameter Variation (HEV용 영구자석 동기전동기의 상수변동 시 최대토크 운전)

  • Cho, Kwan-Yuhl
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5128-5134
    • /
    • 2011
  • This paper investigates the dq current trajectory for maximum torque per ampere(MTPA) operation of an interior PM synchronous motor for HEV(Hybrid Electric Vehicle). Based on the dq current trajectory for the MTPA operation derived from the motor parameters, the change of the MTPA operating point for the variation of the motor parameters including the magnet flux and the dq inductances is considered. The dq current trajectory for MTPA operation is verified through the experiment.

A Study of Regeneration Breaking Control Algorithm for Wounded-field Synchronous Motor Drive (대용량 동기 발전 전동기의 회생 제동 제어 알고리즘에 관한 연구)

  • Ryu, Ho-Seon;Lee, Joo-Hyun;Lim, Ik-Hun;Park, Yo-Jip;Kang, Youn-Jong;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.104-112
    • /
    • 2006
  • SFC(Static Frequence Converter)system has come to be used as drive large synchronous machine in many industry applications. Many papers have been presented on the control algorithm of SFC system, not the acceleration and start-up but the rated speed operation with line connection and the braking operation with regeneration which is used in the industry. Among this, this paper presents the regeneration breaking control algorithm for a large synchronous machine using SFC system. The results of experiment show that the proposed algorithm is proper and effective.

A High Performance Asynchronous Interface Unit for Globally-Asynchronous Locally-Synchronous Systems (전역적 비동기 지역적 동기 시스템을 위한 고성능 비동기식 접속장치)

  • 오명훈;박석재;최호용;이동익
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.5
    • /
    • pp.321-334
    • /
    • 2003
  • Globally-Asynchronous Locally-Synchronous (GALS) systems are worthy of notice as an adequate architecture for a large scaled chip design with guaranteeing easy designs and functional confidence. In this paper, we suggest an advanced structure of the interface unit which is indispensable for GALS systems by using stoppable clocks. The proposed interface unit is composed of a sender module and a receiver module. The sender module can carry out data transmission partially without the relation to an internal clock. We have designed it with 0.25${\mu}{\textrm}{m}$ standard cell library at the gate level and simulated its operation to show performance improvement. Finally, we constructed all example circuit with the interface unit and proved the correct operation of it.