• Title/Summary/Keyword: synchronous operation

Search Result 550, Processing Time 0.026 seconds

Characteristic Comparison of Brushless Motor Type for EPS System (전동식 조향장치용 영구자석형 브러시리스 모터의 타입별 특성 비교)

  • Lee, Min-Hwan;Kim, Il-Yong;Lee, Choong-Sung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.1
    • /
    • pp.53-60
    • /
    • 2012
  • As enforced by the regulation on the improving fuel efficiency and increased the demand on green technology, many interests are focused on electric vehicles and hybrid vehicles. Thus the technology development in electrification of vehicle operation system, including steering and braking field, is actively progressive. Especially electric power steering substitutes for hydraulic power steering rapidly in the market, which is more complex and bigger in packaging volume compared with electric power steering system. The core component in electric power steering system is a motor, which is required to be silent and powerful to guarantee required system performance. Brushless synchronous motors are widely used and many variations of the motors are introduced in the market, while the performance of each type is not well defined or studied for electric power steering system. In this paper, recent developments in brushless synchronous motor are reviewed and compared applying finite element analysis in electromagnetic field. As results, each characteristic of different types of brushless synchronous motors is compared and summarized for optimized selection in electric power steering system.

Parallel Sensorless Speed Control using Power Angle for Dual SPMSMs Fed by a Single Inverter (단일 인버터 기반 두 대의 영구자석 동기전동기 병렬운전에서 전력각을 이용한 속도제어기법)

  • Kim, Kyung-Hoon;Yun, Chul;Kwon, Woo-Hyen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.10
    • /
    • pp.1481-1487
    • /
    • 2017
  • This paper proposes a sensorless speed control algorithm for parallel-connected dual Surface-mounted Permanent Magnet Synchronous Motors fed by a single inverter. For stable parallel operation of synchronous motors with a single inverter, each motor has to be constantly kept in the synchronization state regardless of load torque. If the master motor with the larger load is controlled, the synchronous state will be maintained. Therefore, detection of the master motor is essential. Conventionally, the master motor is determined by comparing the rotor position error from the relation between the back-EMF for torque angle and the flux position. consequently, the position sensor is deemed essential for finding the rotor position. In this paper, we proposed a method that decides the magnitude of the load from the power angle of two motors due to the load variation and selects the motor to control through the sign function for the sensorless speed control without the position sensor. The results of simulation and experiment conducted verify the efficacy of the proposed method.

Space Mission Design For Reconnaissance Micro-Satellite Constellation Using Sun Synchronous-Ground Repeating Orbit (태양동기-지상반복 궤도를 활용한 군 정찰용 초소형 위성군 설계)

  • Cho, Sungmin;Cho, Namsuk
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.125-138
    • /
    • 2020
  • One of the most important steps to consider in utilizing micro-satellites for surveillance or reconnaissance operations is the design of the satellite constellation. The Walker-Delta constellation which is commonly used in designing satellite constellations is not ideal for this operation in which military satellites are required to monitor specific regions continuously in a stable manner. This study aims to discuss the methodology for designing a satellite constellation that is capable of monitoring the fixed region at the fixed time each day by using the Sun synchronous Orbit. The BB(Beach Ball) constellation that we propose outperforms the Walker-Delta constellation in terms of robustness and it holds the merit of being simple in its design, thereby making future expansions more convenient. We expect the BB constellation will have a high applicability as the operational concept of military surveillance satellites is established in the near future.

Research on the Influence of Inter-turn Short Circuit Fault on the Temperature Field of Permanent Magnet Synchronous Motor

  • Qiu, Hongbo;Yu, Wenfei;Tang, Bingxia;Yang, Cunxiang;Zhao, Haiyang
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1566-1574
    • /
    • 2017
  • When the inter-turn short circuit (ITSC) fault occurs, the distortion of the magnetic field is serious. The motor loss variations of each part are obvious, and the motor temperature field is also affected. In order to obtain the influence of the ITSC fault on the motor temperature distribution, firstly, the normal and the fault finite element models of the permanent magnet synchronous motor (PMSM) were established. The magnetic density distribution and the eddy current density distribution were analyzed, and the mechanism of loss change was revealed. The effects of different forms and degrees of the fault on the loss were obtained. Based on the loss analysis, the motor temperature field calculation model was established, and the motor temperature change considering the loop current was analyzed. The influence of the fault on the motor temperature distribution was revealed. The sensitivity factors that limit the motor continuous operation were obtained. Finally, the correctness of the simulation was verified by experiments. The conclusions obtained are of great significance for the fault and high temperature demagnetization of the permanent magnet analysis.

Torque Ripple Reduction of Interior Permanent-Magnet Synchronous Motors Driven by Torque Predictive Control (토크예측제어를 이용한 매입형 영구자석 동기전동기의 토크리플저감기법)

  • Kim, Hyunseob;Han, Jungho;Song, Joong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.102-109
    • /
    • 2013
  • In this paper, a new torque predictive control method of interior permanent magnet synchronous motor is developed based on an extended rotor flux. Also, a duty ratio prediction method is proposed and allows the duty ratio of the active stator voltage vector to be continuously calculated. The proposed method makes it possible to relatively reduce the torque ripple under the steady state as well as to remain the good dynamic response in the transient state. With the duty ratio prediction method, the magnitude and time interval of the active stator voltage vector applied can be continuously controlled against the varying operation conditions. This paper shows a comparative study among the switching table direct torque control(DTC), the SVM-DTC, conventional torque predictive control, and the proposed torque predictive control. Simulation results show validity and effectiveness of this work.

Microcomputer-Based Maximum Efficiency Control of a Synchronous Motor. (마이크로 컴퓨터를 이용한 동기 전동기의 최대 효율제)

  • Hyun, Dong-Seok;Park, Min-Ho
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.12
    • /
    • pp.874-887
    • /
    • 1987
  • The efficiency of a synchronous motor can be substantially improved by controlling armature voltage, field excitation, and load angle on optimum values which yield minimum input power at any specified torque and speed. This improvement is particularly noticeable in the case of light loads. In addition, the control of armature input voltage improves the power factor at which the motor operates. Employed in the analysis is a new equivalent circuit model of the motor which incorporates the frequency dependent nature of the motor parameters and the effects of iron loss. The stability of synchronous motor operation is studied by applying the Nyquist stability criterion to the linearized equations which describe the behavior of the motor as the motor loads perturb about a steady-state operating point. This investigation reveals that, in some cases, the stable region of the motor is delineated from the results of a computer simulation. With a view to reducing harmonic loss and improving torque pulsation from harmonic components, a very poweful pulse amplitude modulation (PAM) method using an 16-bit microcomputer has been developed. This method has the advantages of simplicity of control algorithms and requires small memory space for storing thyristor trigger angles for a three-phase PAM inverter. The method can be used for smooth control of both modulation depth and frequency over a wide range.

  • PDF

Concurrent Robot-Assisted Distal Gastrectomy and Partial Nephrectomy for Synchronous Early Gastric Cancer and Renal Cell Carcinoma: An Initial Experience

  • Kim, Jieun;Kim, Su Mi;Seo, Jeong Eun;Choi, Min Gew;Lee, Jun Ho;Sohn, Tae Sung;Kim, Sung;Bae, Jae Moon;Seo, Seong Il
    • Journal of Gastric Cancer
    • /
    • v.14 no.3
    • /
    • pp.211-214
    • /
    • 2014
  • We report our experience of a concurrent robot assisted distal gastrectomy and partial nephrectomy for synchronous early gastric cancer and renal cell carcinoma. A 55-year-old female patient was diagnosed with early gastric cancer on screening endoscopy. Abdominal computed tomography showed an incidental right renal cell carcinoma. Robot assisted distal gastrectomy was performed, followed by partial nephrectomy. The final pathological examination showed signet ring cell carcinoma within the lamina propria and renal cell carcinoma with negative resection margins. The patient showed no evidence of recurrence at 6-months. A robot-assisted combined operation could be a treatment option for early stages of synchronous malignancies.

Flicker Mitigation in a Wind Farm by Controlling a Permanent Magnet Synchronous Generator (영구자석형 동기발전기를 이용한 풍력단지의 플리커 저감)

  • Hoan, Pham Van;Kim, Dae-Hyun;Ahn, Jin-Hong;Kim, Eel-Hwan;Oh, Seong-Bo;Kim, Ho-Chan;Kim, Se-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.12
    • /
    • pp.1163-1168
    • /
    • 2009
  • The power quality of wind energy becomes more and more important in connecting wind-farms to the grid, especially weak grid. This paper presents the simulation of a wind farm of a permanent magnet synchronous generator (PMSG) and a doubly fed induction generator (DFIG). Flicker mitigation is performed by using PMSG as a static synchronous compensator (STATCOM) to regulate the voltage at the point of common coupling (PCC). A benefit of the measure is that integrating two function of to control the active power flow and to reduce the voltage flicker in a wind farm. Simulation results show that controlling PMSG is an effective and economic measure in reducing the flicker during continuous operation of grid connected wind turbines regardless of short circuit capacity ratio, turbulence intensity and grid impedance angle.

RVOTO Caused by Pulmonary Artery Sarcoma Originating from Pulmonary Valve -Two case report- (식도와 폐의 동시성 중복암 -2예 보고 -)

  • 김대현;이인호;윤효철;김수철;김범식;조규석;박주철
    • Journal of Chest Surgery
    • /
    • v.37 no.2
    • /
    • pp.184-187
    • /
    • 2004
  • The synchronous double cancer of the esophagus and lung is rare. Right lower lobectomy and Ivor Lewis procedure were performed simultaneously in a 75 year-old male patient who had synchronous double primary squamous cell carcinoma of the thoracic esophagus and right lower lobe of the lung, Left upper lobectomy was performed in a 69 year-old male patient who had squamous cell carcinoma of the left upper lobe of the lung, and four months later we performed Ivor Lewis procedure for the squamous cell carcinoma that occurred in the thoracic esophagus. The above two patients were doing well 10 months and 24 months after the operation respectively without recurrence. We treated the two cases of synchronous double cancer of the esophagus and lung with complete resection, and report this with review of literature.

Parallel Sensorless Speed Control using Flux-axis Current for Dual SPMSMs Fed by a Single Inverter

  • Kim, Chang-Bum;Yun, Chul;Yoon, Byung-Keun;Cho, Nae-Soo;Kwon, Woo-Hyen
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1048-1057
    • /
    • 2015
  • This paper proposes a sensorless speed control algorithm for parallel-connected dual Surface-mounted Permanent Magnet Synchronous Motors (SPMSMs) fed by a single inverter. For stable parallel operation of synchronous motors with a single inverter, each motor has to be constantly kept in the synchronization state regardless of load torque. If the master motor with the larger load is controlled, the synchronous state will be maintained. Therefore, detection of the master motor is essential. Conventionally, the master motor is determined by comparing the rotor position error from the relation between the back-EMF for torque angle and the flux position; consequently, the position sensor is deemed essential for finding the rotor position. The parallel sensorless speed control method proposed in this paper uses no position sensor, instead it compares the flux-axis current from the connection between the back-EMF for torque angle and current in unbalanced load conditions. The results of simulation and experiment conducted verify the efficacy of the proposed method.