• Title/Summary/Keyword: switching vector table

Search Result 25, Processing Time 0.024 seconds

Direct Torque Control Method of Induction Machine with Constant Average Torque (일정한 토크 평균치를 가지는 유도전동기 직접토크제어기법)

  • Kim, Jeong-Ok;Jo, Nae-Su;Choe, Byeong-Tae;Kim, U-Hyeon;Im, Seong-Un;Gwon, U-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.31-34
    • /
    • 2003
  • There are several types of switching table for selection voltage vector in direct torque control of induction motor. In general, two-quadrant and four-quadrant operation switching table are used mostly. Two-quadrant operation has an advantage that reduced the torque ripples in comparison with four-quadrant operation, but it has the defect that is not constant average torque. Because the torque increasing slope size by non-zero voltage vector is different from the torque decreasing slope size by zero voltage vector as speed region. The main objective of this study is to maintain constant average torque using two-quadrant operation switching table. In proposed method, the torque increasing slope or decreasing slope are calculated before selected voltage vector is applied. Then, it is applied to zero voltage vector or non-zero voltage vector until the torque increasing slope and decreasing slope are equal. In total magnitude. Therefore it becomes to maintain average torque at whole operation speed. The validity of the proposed method is proven by simulated and experimental results.

  • PDF

A Novel Space Vector modulation Scheme and Direct Torque Control for Four-switch BLDCM Using Flux Observer

  • Pan, Lei;Wang, Beibei;Su, Gang;Cheng, Baohua;Peng, Guili
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.251-260
    • /
    • 2015
  • The main purpose of this paper is to describe a DTC (direct torque control) method for four-switch brushless dc motor (BLDCM) drive. In the method, a novel voltage space vector modulation scheme, an optimal switching table, and a flux observation method are proposed. Eight voltage vectors are summarized, which are selected to control BLDCM in SVPWM pattern, and an optimal switching table is proposed to improve the torque distortion caused by midpoint current of the split capacitors. Unlike conventional flux observers, this observer does not require speed adaptation and is not susceptible to speed estimation errors, especially, at low speed. Global asymptotic stability of the flux observer is guaranteed by the Lyapunov stability analysis. DC-offset effects are mitigated by introducing a PI component in the observer gains. This method alleviates the undesired current and torque distortion which is caused by uncontrollable phase. The correctness and feasibility of the method are proved by simulation and experimental results.

Problems of Stator Flux Estimation in DTC of PMSM Drives

  • Kadjoudj, M.;Golea, N.;Benbouzid, M.E.H
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.468-477
    • /
    • 2007
  • The DTC of voltage source inverter-fed PMSMs is based on hysteresis controllers of torque and flux. It has several advantages, namely, elimination of the mandatory rotor position sensor, less computation time, and rapid torque response. In addition, the stator resistance is the only parameter, which should be known, and no reference frame transformation is required. The DTC theory has achieved great success in the control of induction motors. However, for the control of PMSM drives proposed a few years ago, there are many basic theoretical problems that must be clarified. This paper describes an investigation into the effect of the zero voltage space vectors in the DTC system and points out that if using it rationally, not only can the DTC of the PMSM drive be driven successfully, but torque and flux ripples are reduced and overall performance of the system is improved. The implementation of DTC in PMSM drives is described and the switching tables specific for an interior PMSM are derived. The conventional eight voltage-vector switching table, which is namely used in the DTC of induction motors does not seem to regulate the torque and stator flux in a PMSM well when the motor operates at low speed. Modelling and simulation studies have both revealed that a six voltage-vector switching table is more appropriate for PMSM drives at low speed. In addition, the sources of difficulties, namely, the error in the detection of the initial rotor position, the variation of stator resistance, and the offsets in measurements are analysed and discussed.

A New Simplified Vector Control For A High Performance Common-Arm IHCML Inverter (고성능 공통암 IHCML 인버터를 위한 새로운 벡터 제어 방식)

  • Song, Sung-Geun;Park, Sung-Jun;Nam, Hae-Kon;Kim, Kwang-Heon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1071-1079
    • /
    • 2007
  • In this paper, a novel space vector control method for isolated multi-level inverter using 3-phase low frequency transformers is proposed. This method is based on the simplification of the space-vector diagram of a five-level inverter using calculated table into fully programming method. The execution time of the proposed method is about same as that of the method using calculated table. Also, the proposed method is easily applied to other case level inverter. We applied this method into the 3-phase IHCML inverter using common arm. It makes possible to use a single DC power source due to employing low frequency transformers. In this inverter, the number of transformers could be reduced compare with an exiting 3-phase multi-level inverter using single phase transformer. In addition, this method generates very low harmonic distortion operation with nearly fundamental switching frequency. Finally, We tested multi-level inverter to clarify electric circuit and reasonableness through Matlab simulation and experiment by using prototype inverter.

A study on the Novel Current Control method in vector controlled inverter drive system (벡터제어 인버터의 새로운 전류제어에 관한 연구)

  • Lee, Y.J.;Yim, N.H.;Oh, W.S.;Son, Y.D.;Min, K.K.
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.346-350
    • /
    • 1990
  • This paper proposes a novel current control strategy for current regulated VSI-PWM transistor inverter. The conventional hysteresis control method has good dynamic responses. But the switching frequencies are high because it does not optimize switching patterns. Proposed current control strategy can optimize switching patterns. As regulator, three level comparators are used. The outputs of the comparators select appropriate inverter output voltage vectors via switching table stored in EPROM. The simulation and exparimental results in comparison to contentional hysteresis strategy are presented and discussed.

  • PDF

Direct Torque Control according to Flux and Torque of Hysterisis Band (자속 및 토오크 히스테리시스 밴드폭에 따른 직접토오크 제어)

  • Choi, Youn-Ok;Jeong, Sam-Yong;Kim, Dae-Gon;Kim, Pyung-Ho;Cho, Geum-Bae;Baek, Hyung-Lae
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1206-1208
    • /
    • 2001
  • Direct torque control(DTC) of AC motor has the fast torque and flux dynamic responses even though it has very simple scheme to implement. DTC is also very simple in its implementation because it needs only two hysteresis comparators and switching vector table for both flux and torque control. The amplitude of hysteresis band greatly influences on the drive performance such as flux and torque ripple, switching frequency and current harmonics. Therefore, authors analysis flux and torque hysteresis bands is suggested considering switching frequency and harmonic distortion of currents.

  • PDF

Torque Ripple Reduction in Three-Level Inverter-Fed Permanent Magnet Synchronous Motor Drives by Duty-Cycle Direct Torque Control Using an Evaluation Table

  • Chen, Wei;Zhao, Ying-Ying;Zhou, Zhan-Qing;Yan, Yan;Xia, Chang-Liang
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.368-379
    • /
    • 2017
  • In this paper, a direct torque control algorithm with novel duty cycle-based modulation is proposed for permanent magnet synchronous motor drives fed by neutral-point clamped three-level inverters. Compared with the standard DTC, the proposed algorithm can suppress steady-state torque ripples as well as ensure neutral-point potential balance and smooth vector switching. A unified torque/flux evaluation table with multiple voltage vectors and precise control levels is established and used in this method. This table can be used to evaluate the effects of duty-cycle vectors on torque and flux directly, and the elements of the table are independent of the motor parameters. Consequently, a high number of appropriate voltage vectors and their corresponding duty cycles can be selected as candidate vectors to reduce torque ripples by looking up the table. Furthermore, small vectors are incorporated into the table to ensure the neutral-point potential balance with the numerous candidate vectors. The feasibility and effectiveness of the proposed algorithm are verified by both simulations and experiments.

A Study of Using Optimal Hysteresis Band Amplitude for Direct Torque Control of Induction Motor (유도전동기 직접토크제어의 히스테리시스 밴드 크기의 최적화에 관한 연구)

  • Jeong B.H.;Kim S.K.;Park J.K.;Oh G.K.;Cho G.B.;Baek H.L.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.812-815
    • /
    • 2003
  • Most of all, DTC drive is very simple in its implementation because it needs only two hysteresis comparator and switching vector table for both flux and torque control. The switching strategy of a conventional direct torque control scheme which is based on hysteresis comparator results in a variable switching frequency which depends on the speed, flux, stator voltage and the hysteresis of the comparator. The amplitude of hysteresis band greatly influences on the drive performance such as flux and torque ripple and inverter switching frequency. In this paper the influence of the amplitudes of flux and torque hysteresis bands and sampling time of control program on the torque and flux ripples are investigated. Simulation results confirm the superiority of the DTC under the proposed method over the conventional DTC.

  • PDF

A Study of Using Optimal Hysteresis Band Amplitude Tuning for Direct Torque Control of Induction Motor (최적의 히스테리시스 대역폭을 이용한 유도전동기 직접토크제어에 관한 연구)

  • Jeong, B.H.;Cho, G.B.;Choi, C.J.;Baek, H.L.;Hwang, J.S.;Kim, Y.M.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.598-601
    • /
    • 2003
  • Most of all, DTC drive is very simple in its implementation because it needs only two hysteresis comparator and switching vector table for both flux and torque control. The switching strategy of a conventional direct torque control scheme which is based on hysteresis comparator results in a variable switching frequency which depends on the speed, flux, stator voltage and the hysteresis of the comparator. The amplitude of hysteresis band greatly influences on the drive performance such as flux and torque ripple and inverter switching frequency. In this paper the influence of the amplitudes of flux and torque hysteresis bands and sampling time of control program on the torque and flux ripples are investigated. Simulation results confirm the superiority of the DTC under the proposed method over the conventional DTC.

  • PDF

Direct Torque Control of Induction Motor Using Optimal Hysteresis Band Amplitude (최적의 히스테리시스 밴드 크기를 이용한 유도전동기의 직접토크제어)

  • Jeong, Byeong-Ho;Shin, Sa-Hyun;Lim, Byung-Ok;Lee, Kang-Youn;Cho, Geum-Bae;Baek, Hyung-Lae
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1208-1210
    • /
    • 2003
  • Most of all, DTC drive is very simple in its implementation because it needs only two hysteresis comparator and switching vector table for both flux and torque control. The amplitude of hysteresis band greatly influences on the drive performance such as flux and torque ripple and inverter switching frequency. In this paper the influence of the amplitudes of flux and torque hysteresis bands and sampling time of control program on the torque and flux ripples are investigated. Simulation results confirm the superiority of the DTC under the proposed method over the conventional DTC.

  • PDF