• Title/Summary/Keyword: switching losses

Search Result 533, Processing Time 0.026 seconds

A Bidirectional Dual Buck-Boost Voltage Balancer with Direct Coupling Based on a Burst-Mode Control Scheme for Low-Voltage Bipolar-Type DC Microgrids

  • Liu, Chuang;Zhu, Dawei;Zhang, Jia;Liu, Haiyang;Cai, Guowei
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1609-1618
    • /
    • 2015
  • DC microgrids are considered as prospective systems because of their easy connection of distributed energy resources (DERs) and electric vehicles (EVs), reduction of conversion loss between dc output sources and loads, lack of reactive power issues, etc. These features make them very suitable for future industrial and commercial buildings' power systems. In addition, the bipolar-type dc system structure is more popular, because it provides two voltage levels for different power converters and loads. To keep voltage balanced in such a dc system, a bidirectional dual buck-boost voltage balancer with direct coupling is introduced based on P-cell and N-cell concepts. This results in greatly enhanced system reliability thanks to no shoot-through problems and lower switching losses with the help of power MOSFETs. In order to increase system efficiency and reliability, a novel burst-mode control strategy is proposed for the dual buck-boost voltage balancer. The basic operating principle, the current relations, and a small-signal model of the voltage balancer are analyzed under the burst-mode control scheme in detail. Finally, simulation experiments are performed and a laboratory unit with a 5kW unbalanced ability is constructed to verify the viability of the bidirectional dual buck-boost voltage balancer under the proposed burst-mode control scheme in low-voltage bipolar-type dc microgrids.

Predictive Traffic Control Scheme of ABR Service (ABR 서비스를 위한 예측 트래픽 제어모델)

  • 오창윤;임동주;배상현
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.2
    • /
    • pp.307-312
    • /
    • 2000
  • Asynchronous transfer mode(ATM) is flexible to support the various multimedia communication services such as data, voice, and image by applying asynchronous time-sharing and statistical multiplexing techniques to the existing data communication. ATM service is categorized to CBR, VBR, UBR, and ABR according to characteristics of the traffic and a required service qualities. Among them, ABR service guarantees a minimal bandwidth and can transmit cells at a maximum transmission rate within the available bandwidth. To minimize the cell losses in transmission and switching, a feedback information in ATM network is used to control the traffic. In this paper, predictive control algorithms are proposed for the feedback information. When the feedback information takes a long propagation delay to the backward nodes, ATM switch can experience a congestion situation from the queue length increases, and a high queue length fluctuations in time. The control algorithms proposed in this paper provides predictive control model using slop changes of the queue length function and previous data of the queue lengths. Simulation shows the effectiveness result of the proposed control algorithms.

  • PDF

Input-Series-Output-Parallel Connected DC/DC Converter for a Photovoltaic PCS with High Efficiency under a Wide Load Range

  • Lee, Jong-Pil;Min, Byung-Duk;Kim, Tae-Jin;Yoo, Dong-Wook;Yoo, Ji-Yoon
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.9-13
    • /
    • 2010
  • This paper proposes an input-series-output-parallel connected ZVS full bridge converter with interleaved control for photovoltaic power conditioning systems (PV PCS). The input-series connection enables a fully modular power-system architecture, where low voltage and standard power modules can be connected in any combination at the input and/or at the output, to realize any given specifications. Further, the input-series connection enables the use of low-voltage MOSFETs that are optimized for a very low RDSON, thus, resulting in lower conduction losses. The system costs decrease due to the reduced current, and the volumes of the output filters due to the interleaving technique. A topology for a photovoltaic (PV) dc/dc converter that can dramatically reduce the power rating and increase the efficiency of a PV system by analyzing the PV module characteristics is proposed. The control scheme, consisting of an output voltage loop, a current loop and input voltage balancing loops, is proposed to achieve input voltage sharing and output current sharing. The total PV system is implemented for a 10-kW PV power conditioning system (PCS). This system has a dc/dc converter with a 3.6-kW power rating. It is only one-third of the total PV PCS power. A 3.6-kW prototype PV dc/dc converter is introduced to experimentally verify the proposed topology. In addition, experimental results show that the proposed topology exhibits good performance.

High-Efficiency & Cost-Effective Multi-Output LLC Resonant Converter using Single Transformer (단일 변압기를 이용한 고효율.저가격형 다중출력 LLC 공진형 컨버터)

  • Cho, Sang-Ho;Yoon, Jong-Kyu;Roh, Chung-Wook;Hong, Sung-Soo;Kim, Jong-Hae;Lee, Hyo-Bum;Han, Sang-Kyu
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.439-446
    • /
    • 2008
  • The medium power system for the recent electronic products that can perform the multi-function requires various multi-output, high-efficiency and low cost characteristics. To cope with these critical issues, a new high-efficiency and cost-effective multi-output LLC resonant converter is proposed in this paper. The proposed converter requires only 1 power switch instead of the bulky and expensive non-isolated DC/DC converter. Therefore, it features a simple structure, lower cost and high-efficiency. Especially, since the proposed converter can ensure the ZVS or ZCS of all power switches, it has very desirable advantages such as more improved EMI characteristics and reduced switching losses. Finally, to confirm the operation, validity, and features of the proposed circuit, experimental results from a SMPS prototype for 42" FHD PDP TV are presented.

The Influence of Changing PV Array Interconnections under a Non-uniform Irradiance

  • Ding, Kun;Feng, Li;Qin, Si-Yu;Mao, Jing;Zhang, Jing-Wei;Wang, Xiang;Peng, Tao;Zhai, Quan-Xin
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.631-642
    • /
    • 2016
  • Usually, the output characteristics of a photovoltaic (PV) array are significantly affected by non-uniform irradiance which is caused by ambient obstacles, clouds, orientations, tilts, etc. Some local maximum power points (LMPP) in the current-voltage (I-V) curves of a PV array can result in power losses of the array. However, the output power at the global maximum power point (GMPP) is different in different interconnection schemes in a PV array. Therefore, based on the theoretical analysis and mathematical derivation of different topological structures of a PV array, this paper investigated the output characteristics of dual series PV arrays with different interconnections. The proposed mathematical models were also validated by experimental results. Finally, this paper also concluded that in terms of performance, the total cross tied (TCT) interconnection was not always the optimal structure, especially in a dual series PV array. When one of the PV modules was severely mismatched, the TCT worked worse than the series parallel (SP) structure. This research can provide guidance for switching the interconnection to gain the greatest energy yield in a changeable- structure PV system.

End-to-End Congestion Control of High-Speed Gigabit-Ethernet Networks based on Smith's Principle

  • Lee, Seung-Hyub;Cho, Kwang-Hyun
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.101-104
    • /
    • 2000
  • Nowadays, the issue of congestion control in high-speed communication networks becomes critical in view of the bandwidth-delay products for efficient data flow. In particular, the fact that the congestion is often accompanied by the data flow from the high-speed link to low-speed link is important with respect to the stability of closed-loop congestion control. The Virtual-Connection Network (VCN) in Gigabit Ethernet networks is a packet-switching based network capable of implementing cell- based connection, link-by-link flow-controlled connection, and single- or multi-destination virtual connections. VCN described herein differ from the virtual channel in ATM literature in that VCN have link-by-link flow control and can be of multi-destination. VCNs support both connection-oriented and connectionless data link layer traffic. Therefore, the worst collision scenario in Ethernet CSMA/CD with virtual collision brings about end-to-end delay. Gigabit Ethernet networks based on CSMA/CD results in non-deterministic behavior because its media access rules are based on random probability. Hence, it is difficult to obtain any sound mathematical formulation for congestion control without employing random processes or fluid-flow models. In this paper, an analytical method for the design of a congestion control scheme is proposed based on Smith's principle to overcome instability accompanied with the increase of end-to-end delays as well as to avoid cell losses. To this end, mathematical analysis is provided such that the proposed control scheme guarantees the performance improvement with respect to bandwidth and latency for selected network links with different propagation delays. In addition, guaranteed bandwidth is to be implemented by allowing individual stations to burst several frames at a time without intervening round-trip idle time.

  • PDF

A Soft-Switching Totem-pole Bridgeless Boost Power Factor Correction Rectifier Having Minimized Conduction Losses (소프트 스위칭이 가능한 토템폴 브리지리스 역률보상회로)

  • Lee, Young-Dal;Kim, Chong-Eun;Baek, Jae-Il;Kim, Dong-Kwan;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.213-215
    • /
    • 2018
  • 본 논문에서는, 경부하 조건에서 저감된 스위칭 손실과 중부하 이상 조건에서 영전압 스위칭을 통해 높은 효율을 가지는 토템폴 브리지리스 역률보상회로를 제안한다. 토템폴 브리지리스 역률보상회로는 기존 브리지 다이오드를 포함한 역률보상회로의 단점인 도통패스 구간의 비교적 많은 소자 수를 통한 도통손실이 다소 큰 단점을 보완한 회로이다. 하지만, 토템폴 브리지리스 역률보상회로는 여전히 하드 스위칭을 통한 손실과 주 파워링 다이오드의 역회복 손실로 인한 단점을 지니고 있게 되며, 그로 인해 현재로써는 높은 효율과 안정적인 동작을 위해서는 부득이 GaN FET를 적용한 개발이 대부분이다. Full 부하 조건의 전류 용량을 고려하여 높은 전류 정격을 가지는 GaN FET를 주 스위치로 활용할 경우, 전류용량과 비례하여 기생 커패시턴스에 의한 손실이 커지기 때문에 경부하 조건에서 높은 효율을 확보하기가 다소 어렵다. 또한 구조상 물리적으로 여전히 하드 스위칭 동작을 할 수 밖에 없기 때문에 서버용 전원장치에서 요구하는 높은 효율을 달성하는데 한계를 지니며 높은 비용이 요구되는 단점을 지니게 된다. 이를 해결하기 위해, 제안하는 회로는 간단한 회로를 통해 경부하 조건에서 저감된 스위칭 손실과 중부하 이상 조건에서 소프트 스위칭을 만족하여 전체 부하 조건에서 기존의 GaN FET을 활용한 토템폴 구조 대비 높은 효율을 가지게 된다. 또한, 토템폴 구조임에도 불구하고 중부하 이상 영역에서 소프트 스위칭 동작을 통해 주 스위치를 비교적 저렴하고 신뢰성이 검증된 Si-MOSFET을 적용할 수 있다는 장점을 지닌다. 제안하는 회로의 효용성을 증명하기 위해, 하이라인 입력 전압과 750W 출력 조건에서 실험을 진행하였다.

  • PDF

A Study on the Power Factor Improvement of DC Power Regenerating Systems (직류전력 회생시스템의 역률개선에 관한 연구)

  • 김경원;윤인식;서영민;윤덕용;홍순찬
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.410-415
    • /
    • 2001
  • This paper proposes a new control scheme for the power factor improvement of DC power regenerating systems, which can regenerate the excessive DC power from DC bus line to AC supply in substations for traction systems. From the viewpoint of both power capacity and switching losses, the system is designed on the basis of three-phase square-wave inverters and composed of two inverters, zig-zag connected output transformers, and an AC filter. The output voltages of the regenerating system are not sinusoidal. However, regenerated complex power is analyzed on the basis of fundamental components and thus the reactive power produced by harmonics is not considered. Therefore, it is needed a new control scheme capable of controlling the reactive power nearly to zero even for nonsinusoidal cases. To verify the validity of the proposed control scheme, computer simulations are carried out. And the results show that the power factor is theoretically higher than 0.99.

  • PDF

Optimization of Ar Reshape Process for 4H-SiC Trench MOSFET (4H-SiC Trench MOSFET 응용을 위한 Ar Reshape 공정 최적화)

  • Sung, Min-Je;Kang, Min-Jae;Kim, Hong-Ki;Kim, Seong-jun;Lee, Jung-Yoon;Lee, Wonbeom;Lee, Nam-suk;Shin, Hoon-Kyu
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1234-1237
    • /
    • 2018
  • For 4H-SiC trench MOSFET which can reduce on-resistance and switching losses compared to 4H-SiC planar MOSFET, the optimization study for decrease of sub-trench was carried out. In order to decrease sub-trench, Ar reshape process was used and trench shapes were observed as a function of temperature and process time. As a result, it was confirmed that the process conditions for $1500^{\circ}C$ and 20 min were most effective for the suitable trench profiles. In addition, dry/wet oxidation was performed at the Ar reshaped-samples to observe the oxidation thickness with different crystal orientations.

Influence of the implant-abutment connection design and diameter on the screw joint stability

  • Shin, Hyon-Mo;Huh, Jung-Bo;Yun, Mi-Jeong;Jeon, Young-Chan;Chang, Brian Myung;Jeong, Chang-Mo
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.126-132
    • /
    • 2014
  • PURPOSE. This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. MATERIALS AND METHODS. Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (${\alpha}$=0.05). RESULTS. The postload removal torque value was high in the following order with regard to magnitude: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). CONCLUSION. The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate.