• Title/Summary/Keyword: switch utilization

Search Result 88, Processing Time 0.023 seconds

A Study on Rate-Based Congestion Control Using EWMA for Multicast Services in IP Based Networks (IP 기반 통신망의 멀티캐스팅 서비스를 위한 지수이동 가중평판을 이용한 전송률기반 폭주제어에 관한 연구)

  • Choi, Jae-Ha;Lee, Seng-Hyup;Chu, Hyung-Suk;An, Chong-Koo;Shin, Soung-Wook
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.1
    • /
    • pp.39-43
    • /
    • 2007
  • In high speed communication networks, the determination of a transmission rate is critical for the stability of a closed-loop network system with the congestion control scheme. In ATM networks, the available bit rate (ABR) service is based on a feedback mechanism, i.e., the network status is transferred to the ABR source by a resource management (RM) cell. RM cells contain the traffic information of the downstream nodes for the traffic rate control. However, the traffic status of the downstream nodes can not be directly transferred to the source node in the IP based networks. In this paper, a new rate-based congestion control scheme using an exponential weighted moving average algorithm is proposed to build an efficient feedback control law for congestion avoidance in high speed communication networks. The proposed congestion control scheme assures the stability of switch buffers and higher link utilization of the network. Moreover, we note that the proposed congestion scheme can flexibly work along with the increasing number of input sources in the network, which results in an improved scalability.

  • PDF

ABR Congestion Control for Signal Transmissions in ATM Networks (신호 전송을 위한 ATM 망에서의 ABR 체증제어)

  • 정준영;양현석;계영철;고인선
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.5B
    • /
    • pp.448-456
    • /
    • 2003
  • In this parer, an ABR (Available Bit Rate) congestion control algorithm for voice transmission in ATM networks was proposed. To deal with the network congestion problem, not only the buffer level of a switch but also the variation of the buffer level were considered. Also, to resolve the unfairness among sources where the bit transfer rates vary, a loading factor that is used to adjust the bit rate was introduced. To show the superiority of this paper over others, simulation was done with a network of 7 voice sources and 4 switches, which was represented by Petri net model. ExSpect was used for simulation. The simulation results showed that there was improvement in network utilization and that unfairness among sources were resolved a lot.

Integrating Resilient Tier N+1 Networks with Distributed Non-Recursive Cloud Model for Cyber-Physical Applications

  • Okafor, Kennedy Chinedu;Longe, Omowunmi Mary
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.7
    • /
    • pp.2257-2285
    • /
    • 2022
  • Cyber-physical systems (CPS) have been growing exponentially due to improved cloud-datacenter infrastructure-as-a-service (CDIaaS). Incremental expandability (scalability), Quality of Service (QoS) performance, and reliability are currently the automation focus on healthy Tier 4 CDIaaS. However, stable QoS is yet to be fully addressed in Cyber-physical data centers (CP-DCS). Also, balanced agility and flexibility for the application workloads need urgent attention. There is a need for a resilient and fault-tolerance scheme in terms of CPS routing service including Pod cluster reliability analytics that meets QoS requirements. Motivated by these concerns, our contributions are fourfold. First, a Distributed Non-Recursive Cloud Model (DNRCM) is proposed to support cyber-physical workloads for remote lab activities. Second, an efficient QoS stability model with Routh-Hurwitz criteria is established. Third, an evaluation of the CDIaaS DCN topology is validated for handling large-scale, traffic workloads. Network Function Virtualization (NFV) with Floodlight SDN controllers was adopted for the implementation of DNRCM with embedded rule-base in Open vSwitch engines. Fourth, QoS evaluation is carried out experimentally. Considering the non-recursive queuing delays with SDN isolation (logical), a lower queuing delay (19.65%) is observed. Without logical isolation, the average queuing delay is 80.34%. Without logical resource isolation, the fault tolerance yields 33.55%, while with logical isolation, it yields 66.44%. In terms of throughput, DNRCM, recursive BCube, and DCell offered 38.30%, 36.37%, and 25.53% respectively. Similarly, the DNRCM had an improved incremental scalability profile of 40.00%, while BCube and Recursive DCell had 33.33%, and 26.67% respectively. In terms of service availability, the DNRCM offered 52.10% compared with recursive BCube and DCell which yielded 34.72% and 13.18% respectively. The average delays obtained for DNRCM, recursive BCube, and DCell are 32.81%, 33.44%, and 33.75% respectively. Finally, workload utilization for DNRCM, recursive BCube, and DCell yielded 50.28%, 27.93%, and 21.79% respectively.

Design and Analysis of a Novel Methanol SOFC Combined System for Marine Applications Toward Future Green Shipping Goals

  • Duong Phan Anh;Ryu Bo Rim;Hokeun Kang
    • Journal of Navigation and Port Research
    • /
    • v.47 no.2
    • /
    • pp.106-119
    • /
    • 2023
  • Due to global decarbonization movement and tightening of maritime emissions restrictions, the shipping industry is going to switch to alternative fuels. Among candidates of alternative fuel, methanol is promising for decreasing SOx and CO2 emissions, resulting in minimum climate change and meeting the goal of green shipping. In this study, a novel combined system of direct methanol solid oxide fuel cells (SOFC), proton exchange membrane fuel cells (PEMFC), gas turbine (GT), and organic Rankine cycle (ORC) targeted for marine vessels was proposed. The SOFC is the main power generator of the system, whereas the GT and PEMFC could recover waste heat from the SOFC to generate useful power and increase waste heat utilizing efficiency of the system. Thermodynamics model of the combined system and each component were established and analyzed. Energy and exergy efficiencies of subsystems and the entire system were estimated with participation of the first and second laws of thermodynamics. The energy and exergy efficiencies of the overall multigeneration system were estimated to be 76.2% and 30.3%, respectively. The combination of GT and PEMFC increased the energy efficiency by 18.91% compared to the SOFC stand-alone system. By changing the methanol distribution ratio from 0.05 to 0.4, energy and exergy efficiencies decreased by 15.49% and 5.41%, respectively. During the starting up and maneuvering period of vessels, a quick response from the power supply system and propulsion plant is necessary. Utilization of PEMFC coupled with SOFC has remarkable meaning and benefits.

A Maximum Mechanism of Data Transfer Rate using Parallel Transmission Technology on High Performance Network (고성능 네트워크에서 병렬 전송 기술을 이용한 전송률 극대화 메커니즘)

  • Kim, Young-Shin;Huh, Eui-Nam
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.34 no.9
    • /
    • pp.425-434
    • /
    • 2007
  • Even though Internet backbone speeds have increased in the last few years due to projects like Internet 2 and NGI, many high performance distributed applications are able to achieve only a small fraction of the available bandwidth. The cause of such problem is due to a character of TCP/IP. The primary goal of this protocol is reliable data transmission. Therefore high speed data transmission didn't be considered when TCP/IP is designed. Hence several researchers have been studied in order to solve the problem of TCP/IP. One of these research results, parallel transfer technique, solves this problem to use parallel TCP connections on application level. Additionally, this technique is compatibility. Recently, these researchers have been studied a mechanism to decide the number of parallel TCP connections. However, some researchers reported the number of parallel TCP connection base on only empirical results. Although hardware performance of host affects transmission rate, the hardware performance didn't be considered in their works. Hence, we collect all data related to transmission rate, such as hardware state information (cpu utilization, interrupt, context switch). Then, we analyzed collected data. And, we suggest a new mechanism determining number of parallel TCP connections for maximization of performance based on our analysis.

A Study on Terrestrial UHDTV Broadcasting and Construction of Direct Reception Environment by DVB-T2 (DVB-T2기반으로 지상파 UHDTV방송과 직접수신환경 구축 연구)

  • Park, Sung-Kyu;Jo, Young-Joon;Kim, Dong-Woo;Park, Goo-Man
    • Journal of Broadcast Engineering
    • /
    • v.18 no.4
    • /
    • pp.572-588
    • /
    • 2013
  • In this paper, 4K-UHDTV or 8K-UHDTV and UHD-3DTV that the next generation broadcasting implementation and the possibility of direct receiving environment construction is analyzed on the terrestrial broadcasting. Particularly, we investigated the possibility by analyzing the previous and related works with regard to UHDTV transmission by DVB-T2 that is one of the best commercialized transmission mode. In order that the UHDTV broadcasting succeeds once again after completion of digital terrestrial switch over at the end of 2012, the ultra high resolution image transfer is important. However, the direct, the indoor and ubiquitous receiving environment is important in not only TV but also the personal type multimedia terminal in the sense of UHDTV service penetration. Therefore, in this paper, by using SFN and high error-correcting mode in DVB-T2 standard, the efficient frequency utilization and effective reception environment construction is illustrated. Particularly, SFN network constitution by 2 mutually different frequencies including the VHF bandwidth and UHF band, and etc. is shown. And the method that builds the free wireless receive environment by using SFN low power radio repeater and for home use gap filler is proposed. And the effect and frequency amount required are presented, when UHDTV broadcasting use 10MHz bandwidth.

A Study on Efficient Cell Queueing and Scheduling Algorithms for Multimedia Support in ATM Switches (ATM 교환기에서 멀티미디어 트래픽 지원을 위한 효율적인 셀 큐잉 및 스케줄링 알고리즘에 관한 연구)

  • Park, Jin-Su;Lee, Sung-Won;Kim, Young-Beom
    • Journal of IKEEE
    • /
    • v.5 no.1 s.8
    • /
    • pp.100-110
    • /
    • 2001
  • In this paper, we investigated several buffer management schemes for the design of shared-memory type ATM switches, which can enhance the utilization of switch resources and can support quality-of-service (QoS) functionalities. Our results show that dynamic threshold (DT) scheme demonstrate a moderate degree of robustness close to pushout(PO) scheme, which is known to be impractical in the perspective of hardware implementation, under various traffic conditions such as traffic loads, burstyness of incoming traffic, and load non-uniformity across output ports. Next, we considered buffer management strategies to support QoS functions, which utilize parameter values obtained via connection admission control (CAC) procedures to set tile threshold values. Through simulations, we showed that the buffer management schemes adopted behave well in the sense that they can protect regulated traffic from unregulated cell traffic in allocating buffer space. In particular, it was observed that dynamic partitioning is superior in terms of QoS support than virtual partitioning.

  • PDF

A Study on the Utilization and Control Method of Hybrid Switching Tap Based Automatic Voltage Regulator on Smart Grid (스마트그리드의 탭 전환 자동 전압 조정기의 다중 스위칭 제어 방법 및 활용 방안에 관한 연구)

  • Park, Gwang-Yun;Kim, Jung-Ryul;Kim, Byung-Gi
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.12
    • /
    • pp.31-39
    • /
    • 2012
  • In this paper, we propose a microprocessor-based automatic voltage regulator(AVR) to reduce consumers' electric energy consumption and to help controlling peak demanding power. Hybrid Switching Automatic Voltage Regulator (HS-AVR) consist of a toroidal core, several tap control switches, display and command control parts. The coil forms an autotransformer which has a serial main winding and four parallel auxiliary windings. It controls the output voltage by changing the combination of the coils and the switches. Relays are adopted as the link switches of the coils to minimize the loss. To make connecting and disconnecting time accurate, relays of the circuit have parallel TRIACs. A software phase locked loop(PLL) has been used to synchronize the timings of the switches to the voltage waveform. The software PLL informs the input voltage zero-crossing and positive/negative peak timing. The traditional voltage transformers and AVRs have a disadvantage of having a large mandatory capacity to accommodate maximum inrush current to avoid the switch contact damage. But we propose a suitable AVR for every purpose in smart grid with reduced size and increased efficiency.