• Title/Summary/Keyword: switch open circuit

Search Result 30, Processing Time 0.027 seconds

A Fault Diagnosis Method in Cascaded H-bridge Multilevel Inverter Using Output Current Analysis

  • Lee, June-Hee;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2278-2288
    • /
    • 2017
  • Multilevel converter topologies are widely used in many applications. The cascaded H-bridge multilevel inverter (CHBMI), which is one of many multilevel converter topologies, has been introduced as a useful topology in high and medium power. However, it has a drawback to require a lot of switches. Therefore, the reliability of CHBMI is important factor for analyzing the performance. This paper presents a simple switch fault diagnosis method for single-phase CHBMI. There are two types of switch faults: open-fault and short-fault. In the open-fault, the body diode of faulty switch provides a freewheeling current path. However, when the short-fault occurs, the distortion of output current is different from that of the open-fault because it has an unavailable freewheeling current flow path due to a disconnection of fuse. The fault diagnosis method is based on the zero current time analysis according to zero-voltage switching states. Using the proposed method, it is possible to detect the location of faulty switch accurately. The PSIM simulation and experimental results show the effectiveness of proposed switch fault diagnosis method.

Switch Open Circuit Fault Detection for Power Conversion System of Hybrid Electric Vehicles (전기자동차용 전력변환시스템의 스위치 개방형 고장 검출)

  • Park, Tae-Sik
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.199-204
    • /
    • 2013
  • Recently, the demand for fuel efficient electric vehicles (EVs) and hybrid electric vehicles (HEVs) has been growing globally. Due to the increased number of switching devices in the electrified vehicles, the probability of the semiconductor device failure is much higher than in other application areas. A sudden failure in one of the power switches and insufficient power management ability in the systems not only decreases system performance, but also leads to critical safety problems. In this paper, novel switch open circuit fault detection method is proposed, and the proposed approach is verified by experiments.

Investigation of Fault-Mode Behaviors of Matrix Converters

  • Kwak, Sang-Shin
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.949-959
    • /
    • 2009
  • This paper presents a systematic investigation of the fault-mode behaviors of matrix converter systems. Knowledge about converter behaviors after fault occurrence is important from the standpoint of reliable system design, protection and fault-tolerant control. Converter behaviors have been, in detail, examined with both qualitative and quantitative approaches for key fault types, such as switch open-circuited faults and switch short-circuited faults. Investigating the fault-mode behaviors of matrix converters reveals that converter operation with switch short-circuited faults leads to overvoltage stresses as well as overcurrent stresses on other healthy switching components. On the other hand, switch open-circuited faults only result in overvoltage to other switching components. This study can be used to predict fault-mode converter behaviors and determine additional stresses on remaining power circuit components under fault-mode operations.

Open Fault Diagnosis Method for Five-Phase Induction Motor Driving System (5상 유도전동기 구동 시스템을 위한 인버터의 개방고장진단 방법)

  • Baek, Seung-Koo;Shin, Hye-Ung;Kang, Seong-Yun;Park, Choon-Soo;Lee, Kyo-Beum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.304-310
    • /
    • 2016
  • This paper proposes a fault diagnosis method for an open-fault in inverter driving five-phase induction motor. The five-phase induction motor has a high output torque and small torque ripple in comparison to three-phase. The best advantage of the five-phase induction motor is fault diagnosis and tolerant control using redundancy of phases. This paper uses an inverter as a power converter for driving a five-phase induction motor. If a switch of inverter occurs to the open-fault, this problem is the influence on the output current and output torque. To solve this problem, there is need of an accurate diagnosis and fault switch distinction. Therefore, this paper propose a fault detection method of the open-fault switches for the fault diagnosis. First, analyzing the pattern for the open-circuit fault of one phase. next, analyzing the pattern for the open-circuit fault of each inverter switches. Through the pattern analysis, It defines the scope of each of the failure switch. Thereafter, By using an algorithm that proposes to perform a fault diagnosis method. The proposed algorithm is verified from the experiment with the 1.5 kW five-phase induction motor.

Low-Cost Fault Diagnosis Algorithm for Switch Open-Damage in BLDC Motor Drives

  • Park, Byoung-Gun;Lee, Kui-Jun;Kim, Rae-Young;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.702-708
    • /
    • 2010
  • In this paper, a fault diagnosis algorithm for brushless DC (BLDC) motor drives is proposed to maintain control performance under switch open-damage. The proposed fault diagnosis algorithm consists of a simple algorithm using measured phase current information and it detects open-circuit faults based on the operating characteristic of BLDC motors. The proposed algorithm quickly recovers control performance due to its short detection time and its reconfiguration of the system topology. It can be embedded into existing BLDC drive software as a subroutine without additional sensors. The feasibility of the proposed fault diagnosis algorithm is proven by simulation and experimental results.

Electrically-induced actuation for open-loop control to cancel self-excitation vibration

  • Makihara, Kanjuro;Ecker, Horst
    • Smart Structures and Systems
    • /
    • v.9 no.2
    • /
    • pp.189-206
    • /
    • 2012
  • This paper focuses on the actuation system combined with a piezoelectric transducer and an electric circuit, which leads to a new insight; the electric actuation system is equivalent to mechanical variable-stiffness actuation systems. By controlling the switch in the circuit, the electric status of the piezoelectric transducer is changed, and consequently a variable-stiffness mechanism is achieved on the electric actuator. This proposed actuator features a shift in the equilibrium point of force, while conventional electrically-induced variable-stiffness actuators feature the variation of the stiffness value. We intensively focus on the equilibrium shift in the actuation system, which has been neglected. The stiffness of the variable-stiffness actuator is periodically modulated by controlling the switch, to suppress the vibration of the system in an open-loop way. It is proved that this electric actuator is equivalent to its mechanical counterpart, and that the electrical version has some practical advantages over the mechanical one. Furthermore, another kind of electrically-induced variable-stiffness actuator, using an energy-recycling mechanism is also discussed from the viewpoint of open-loop vibration control. Extensive numerical simulations provide comprehensive assessment on both electrically-induced variable-stiffness actuators employed for open-loop vibration control.

A Simple Open-Circuit Fault Detection Method for a Sparse Matrix Converter (스파스 매트릭스 컨버터의 간단한 개방 사고 검출 기법)

  • Lee, Eunsil;Lee, Kyo-Beum;Joung, Gyu-Bum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.217-224
    • /
    • 2013
  • This paper presents a diagnostic method for a sparse matrix converter that detects faults in any single switch or a pair of switches. The sparse matrix converter is functionally equivalent to the standard matrix converter but has a reduced number of switches. The proposed diagnostic method is based in the measurement of input and output currents. The currents have respective characteristic according to the location of faulty switches. This method not only detects the switches of open-circuit fault but identifies the location of the faulty switching devices without complicated calculations. The simulation and experimental results verify that, based on the proposed method, the fault of sparse matrix converter can be easily and fast detected.

Implementation of the high efficiency buck converter using the resonant circuit (공진회로를 이용한 고효율 Buc 컨버터의 구현)

  • 임승하;사공석진
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.11
    • /
    • pp.167-174
    • /
    • 1996
  • For the decreasing of switching loss, this paper designs the improved buck converter circuit and then compare with the conventional buck converter and finally analyzes the performance. When the switch is turn-off, in the buck converter using the smoothing capacitor, the flow of transient current and peak voltage having the high frequency components was generated because of the instantaneous open-state in the teminals of the switch. However, the buck converter presented in this paper eliminated this disadvantage by using the L-C circuit. Therefore, the higher PF in 0.85 is achieved than that of the buck converter using the smoothing capacitor. Also, due to the decreasing of the harmonic contain rate, the current usage rate is to be higher than that of the conventional buck converter by 4.48dB and the output voltage varient rate for the step response is to be lower 1.32 times than that of the conventional buck converter.

  • PDF

An Implementation of the Fault Simulator for Switch Level Faults (스위치 레벨 결함 모델을 사용한 결함시뮬레이터 구현)

  • Yeon, Yun-Mo;Min, Hyeong-Bok
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.2
    • /
    • pp.628-638
    • /
    • 1997
  • This paper describes an implementation of fault simulator that can switch level fault models such as transistor stuck-open and stuck-closed faults as well as stuck-at faults. It overcomes the limitation when only stuck-at faults are used in VLSI circuits. Signal flow of a transistor switch is bidirectional in its nature, but most of signal flows in a switch level circuits, about 95%, are in one direction. This fault simulator focuses on the way which changes a switch level circuit into a graph model with two directed edges. Two paths from Vdd to ground and from ground to directions. Logic simulation is performed along dominant signal flows. The switch level fault simulation estimates the dominant path by injecting switch-level fualts, and pattern vectors are used for faults simulation. Experimental results are shown to demonstrate correctness of the fault simulator.

  • PDF

Managed Object and Distributed Network Management Model in Open Interface of OBS Network (개방형 인터페이스가 적용된 OBS 망의 관리객체 및 분산 망 관리 모델)

  • Kwon TaeHyun;Kim ChoonHee;Cha YoungWook
    • The KIPS Transactions:PartC
    • /
    • v.12C no.3 s.99
    • /
    • pp.449-456
    • /
    • 2005
  • Optical burst switching (OBS) overcomes the inefficient resource usage of optical circuit switching and minimizes the optical buffering requirement of optical packet switching. General switch management protocol (GSMP) is an open interface between a label switch and a controller, and it provides connection, configuration, performance, event management and synchronization. GSMP open interface in the OBS network allows the implementation of OBS switch to be simple by separating the data forward plane from the control plane. We defined managed objects to support connection, configuration, performance, and fault management for the management of OBS network in the GSMP open interface. We proposed the network management model, in which the above managed objects are distributed in a controller and an OBS switch according to network management functions. We verified the possibility of connection management using distributed network management model in the GSMP open interface of OBS network by implementing GSMP and network management functions with managed objects of OBS.