• Title/Summary/Keyword: swing phase

Search Result 255, Processing Time 0.023 seconds

Effects of the Patellar Tendon Strap on Kinematics, Kinetic Data and Muscle Activity During Gait in Patients With Chronic Knee Osteoarthritis

  • Eun-Ji Lee;Ki-Song Kim;Young-In Hwang
    • Physical Therapy Korea
    • /
    • v.30 no.2
    • /
    • pp.110-119
    • /
    • 2023
  • Background: Osteoarthritis is a common condition with an increasing prevalence and is a common cause of disability. Osteoarthritic pain decreases the quality of life, and simple gait training is used to alleviate it. Knee osteoarthritis limits joint motion in the sagittal and lateral directions. Although many recent studies have activated orthotic research to increase knee joint stabilization, no study has used patellar tendon straps to treat knee osteoarthritis. Objects: This study aimed to determine the effects of patellar tendon straps on kinematic, mechanical, and electromyographic activation in patients with knee osteoarthritis. Methods: Patients with knee osteoarthritis were selected. After creating the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), leg length difference, Q-angle, and thumb side flexion angle of the foot were measured. Kinematic, kinetic, and muscle activation data during walking before and after wearing the orthosis were viewed. Results: After wearing the patellar tendon straps, hip adduction from the terminal stance phase, knee flexion from the terminal swing phase, and ankle plantar flexion angle increased during the pre-swing and initial swing phases. The cadence of spatiotemporal parameters and velocity increased, and step time, stride time, and foot force duration decreased. Conclusion: Based on the results of this study, the increase in plantar flexion after strap wearing is inferred by an increase due to neurological mechanisms, and adduction at the hip joint is inferred by an increase in adduction due to increased velocity. The increase in cadence and velocity and the decrease in gait speed and foot pressure duration may be due to joint stabilization. It can be inferred that joint stabilization is increased by wearing knee straps. Thus, wearing a patellar tendon strap during gait in patients with knee osteoarthritis influences kinematic changes in the sagittal plane of the joint.

Performance Evaluation of Swing-Nose Crossing Turnout on Slab Track (2) (콘크리트궤도용 고속분기기 성능평가 (2))

  • Kim, Si-Chul;Kim, Man-Cheol;Hwang, Kwang-Ha;Lee, Dong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.717-724
    • /
    • 2011
  • In order to commercialize the track systems including the turnouts developed in Korea, the guideline of technical and systematic performance evaluation considering local environment was established on Aug. 2010. It consists of a technical compatibility, laboratory test and in-service test. Technical compatibility and laboratory test of the domestically-developed swing-nose crossing turnout on slab track(F18.5) were evaluated according to the guideline. And then in-service test was performed for the turnout installed at the 2nd phase site of Kyung-Bu HSR. In-service test is comprised of monitoring, and field and on-board test during KTX operation, where monitoring is to check the maintainability, and field and on-board test is to confirm structural and running safety. This paper is intended to explain the requirements for the in-serve test and analyze the results of monitoring and the data measured at field and on-board. Based on the in-service test, it is proven that performance of the domestically-developed swing-nose crossing turnout on slab track(F18.5) well satisfies the requirements of the guideline.

  • PDF

The Effectiveness of Backward Gait Training on the Treadmill in Children With Spastic Diplegic Cerebral Palsy: A Pilot Study (트레드밀에서 뒤로걷기 훈련이 경직성 양하지 뇌성마비 아동의 보행에 미치는 영향: 사전 연구)

  • Kim, Sung-Gyung;Ryu, Young-Uk;Kim, Won-Ho
    • Physical Therapy Korea
    • /
    • v.19 no.3
    • /
    • pp.81-90
    • /
    • 2012
  • The aim of the current study was to assess the effectiveness of backward gait training on the treadmill in patients with spastic diplegic cerebral palsy (CP). Twelve patients with spastic diplegic CP participated in the study. An 8-week course of backward gait training was administered to the subjects for 3 days per week. Pre-intervention and post-intervention assessments of temporal-spatial gait parameters, the symmetry of the bilateral lower extremity weight bearing, and gross motor function were analyzed using motion analysis system, force plate, and Gross Motor Function Measurement (GMFM). There were significant improvements (p<.05) in the measures of both step length and right stance phase time. Joint kinematics showed increase in right hip abduction in initial contact and terminal swing, right hip external rotation and knee flexion in mid-swing, left ankle dorsiflexion in initial contact and terminal swing (p<.05). The symmetry of the bilateral lower extremity weight bearing and GMFM also significantly increased (p<.05). These findings indicate that backward gait training using a treadmill is beneficial for patients with spastic diplegic CP.

Kinetic Analysis of the Lower Body Joints on Golf Swing (골프 스윙시 하지의 운동역학적 분석)

  • Chang, Jae-Kwan;Ryu, Jae-Kyun
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.4
    • /
    • pp.339-347
    • /
    • 2014
  • The purpose of this study was to investigate joint torques of lower body segments on professional golfers. Three dimensional swing analysis was conducted on the seven subjects. Each subject was asked to swing with 45 inches of Callaway driver, where two force plates (9286AA, Kistler, Switzerland) were built, with his normal speed and tempo. The resultant joint moments of the lower extremities were computed using the kinematic variables of the segments, anthropometric measures and the ground reaction force data by inverse dynamics method. Based on the results of this study, the following conclusions were drawn; It was found that the left ankle joint torque at 3rd phase was increased toward extension on the X-axis and abduction on the Y-axis. The left knee joint torque was alternated from flexion to extension direction in order to lower down the body weight at the beginning of the downswing. The lumbar joint torque was alternated from flexion to extension in order to speed up the upper body rotation which could increase the club head speed ultimately.

On the Design of Novel Hybrid Wave Generator (신형식 다기능 조파기 설계)

  • Kim, Hyochul;Oh, Jungkeun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.2
    • /
    • pp.112-120
    • /
    • 2021
  • The novel wave generating system of a wave flume has been devised by utilizing the analytic solution of wave board motion in idealized two dimensional space. The arbitrary oscillation motion of submerged wave board segment has been defined by sinusoidal motion of upper and lower end of the wave board. The analytic solution of the wave board motion has been represented by the solution of board motion due to flap motion and swing motion. Arbitrary oscillation of the board could be specified by determining amplitude, frequency, and the phase lag. A novel hybrid wave generator could be operated not only in piston motion but also in flap or swing motion by selection of control parameter. The wave generator has unique motion enhancing ability by appending flap motion or swing motion to piston motion in wave generation. In addition the hybrid wave generator has advantages in generating high quality wave spectrum of irregular wave in simulating real sea condition.

Effect of Weight Loads Applied to the Ankle on Walking Factors of a Stroke Patient (발목에 적용한 무게 부하가 뇌졸중 환자의 보행요소에 미치는 영향)

  • Lee, Su-Kyoung
    • PNF and Movement
    • /
    • v.16 no.2
    • /
    • pp.179-185
    • /
    • 2018
  • Purpose: This study aimed to analyze the visual and spatial elements of the gait of a stroke patient who had diverse ankle weight loads applied, according to weight changes. Methods: The subject was a 57-year-old stroke patient diagnosed and hospitalized with a left intracerebral hemorrhage. A weight equivalent to 0%, 1%, and 2% of his body weight was applied to the area 5cm upward from the ankle using a Velcro strap. He was then trained on a treadmill, receiving a six-minute walk test to evaluate his gait ability. A gait analyzer was used to collect visual and spatial elements, such as gait distance, gait velocity, cadence, step length, stride length, and swing phase, according to a weight load equivalent to 0%, 1%, and 2% of his body weight. Results: According to the results of applying 0%, 1%, and 2% of his body weight on the ankle, except for gait velocity, his gait distance, cadence, step length, stride length, and swing phase were higher when 1% of his body weight was applied compared to 0% or 2% of his body weight. Conclusion: Applying a weight equivalent to 1% of the body weight to the ankle positively affected the visual and spatial element of the gait and heightened the efficiency of exercise during treadmill training, a gait-training tool generally used for stroke patients. However, the result is difficult to generalize because the number of subjects was small with only one subject.

Design of Clutch Mechanism for Increased Actuator Energy Efficiency of Electrically Actuated Lower Extremity Exoskeleton (전기식 하지 외골격 로봇의 구동기 에너지 효율 향상을 위한 클러치 메커니즘 설계)

  • Kim, Ho Jun;Kim, Wan Soo;Lim, Dong Hwan;Han, Chang Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.3
    • /
    • pp.173-181
    • /
    • 2016
  • This paper reports on the development of a roller-cam clutch mechanism. This mechanism can transfer bidirectional torque with high backdrivability, as well as increase actuation energy efficiency, in electrical exoskeleton robots. The developed mechanism was installed at the robot knee joint and unclutched during the swing phase which uses less metabolic energy, thereby functioning as a passive joint. The roller-cam clutch aimed to increase actuation energy efficiency while also producing high backdrivability by generating zero impedance for users during the swing phase. To develop the mechanism, mathematical modeling of the roller-cam clutch was conducted, with the design having more than three safety factors following optimization. Titanium (Ti-6AL-4V) material was used. Finally, modeling verification was done using ANSYS software.

Kinematical Analysis of Tichonkich Motion in Parallel Bars (평행봉 Tichonkich 동작의 운동학적 분석)

  • Park, Jong-Hoon;Back, Jin-Ho
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.3
    • /
    • pp.21-30
    • /
    • 2005
  • The purpose of this study is helps to make full use for perfect performance by grasping the defects of Tichonkich motion performed by athlete CSM For this, the study analyzed kinematical variables through Tichonkich motions performed at the first selection competition(1st trial) and final selection competition(2nd trial) for the dispatch to the 28th Athens Olympic Games using the three-dimensional cinematographical method with a high-speed video camera, and obtained the following results. 1. During Tichonkich motion, the execution time of up swing and the right hand moving to the left bar was shorter in the 2nd trial than the 1st one, while the execution time of down swing, the support of the left bar and the right hand moving to the right bar was longer in the 2nd trial than the 1st trial. 2. The horizontal position of COG in the 2nd trial was -35cm in the 1st stage, 42cm in the 3rd stage and 29cm in the 4th stage, that is, it showed a great swing focused on the circular movement compared to the 1st trial, while the vertical position of COG was -59cm in the 2nd stage, that is, it showed a small swing focused on a up and down movement. Also the 5th stage vertical position was 98cm, and the 6th stage vertical position was 95cm in the 2nd trial which were higher than those of the 1st trial, so it has provided magnificence required in the modern gymnastics. 3. And it was indicated that the horizontal velocity at the down swing phase proceeded forward more rapidly in the 2nd trial than that in the 1st trial, and the reverse ascent made a rapid vertical rise lessening left and right velocity change. And in the 5th stage, the 2nd trial was kept very slower in horizontal, vertical and left and right velocity that in the 1st trial, so it reached a handstand with leisurely movement. 4. In the 2nd trial, shoulder joint of the 1st, 2nd, 3rd stages kept a larger angle than that in the 1st trial, that is, it made a great swing while in the 1st trial, it showed a swing movement dependent on kick movement by the flexion and extension of hip joint. Also in the 2nd trial, the body formed a vertical posture with both hands supporting the left bar and hip joint was kept larger as $198^{\circ}$ and $190^{\circ}$ in the 5th and 6th stage than that in the 1st trial, so it made a handstand with the body uprightly stretched out, and magnificent and stable movement.

Robotic-assisted gait training applied with guidance force for balance and gait performance in persons with subacute hemiparetic stroke

  • Son, Dong-Wook;Hwang, Sujin
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.3
    • /
    • pp.106-112
    • /
    • 2017
  • Objective: Robot assisted gait training is implemented as part of therapy for the recovery of gait patterns in recent clinical fields, and the scope of implications are continuously increasing. However clear therapy protocols of robot assisted gait training are insufficent. The purpose of this study was to investigate the effects of robot-assisted gait training applied with guidance force on balance and gait performance in persons with hemiparetic stroke. Design: Two group pre-test post-test design. Methods: Nineteen persons were diagnosed with hemiparesis following stroke participated in this study. The participants were randomly assigned to the unilateral guidance group or bilateral guidance group to conduct robot-assisted gait training. All participants underwent robot-assisted gait training for twelve sessions (30 min/d, 3 d/wk for 4 weeks). They were assessed with gait parameters (gait velocity, cadence, step length, stance phase, and swing phase) using Optogait. This study also measured the dynamic gait index (DGI), the Berg balance scale (BBS) score, and timed up and go (TUG). Results: After training, BBS scores were was significantly increased in the bilateral training group than in the unilateral guidance group (p<0.05). Spatiotemporal parameters were significantly changed in the bilateral training group (gait speed, swing phase ratio, and stance phase ratio) compared to the unilateral training group (p<0.05). Conclusions: The results of this study suggest that robot-assisted gait training show feasibility in facilitating improvements in balance and gait performance for subacute hemiparetic stroke patients.

Development of Knee Ankle Foot Orthosis for Gait Rehabilitation Training using Plantaflexion and Knee Extension Torque (족저굴곡과 무릎 신전 토크를 이용한 보행 재활 훈련용 장하지 보조기 개발)

  • Kim, Kyung;Kim, Jae-Jun;Heo, Min;Jeong, Gu-Young;Ko, Myoung-Hwan;Kwon, Tae-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.10
    • /
    • pp.948-956
    • /
    • 2010
  • The purpose of this study was to test the effectiveness of a prototype KAFO (Knee-Ankle-Foot Orthosis) powered by two artificial pneumatic muscles during walking. We had previously built powered AFO (Ankle-Foot Orthosis) and KO (Knee Orthosis) and used it effectively in studies on assistance of plantaflexion and knee extension motion. Extending the previous study to a KAFO presented additional challenges related to the assistance of gait motion for rehabilitation training. Five healthy males were performed gait motion on treadmill wearing KAFO equipped with artificial pneumatic muscles to power ankle plantaflexion and knee extension. Subjects walked on treadmill at 1.5 km/h under four conditions without extensive practice: 1) without wearing KAFO, 2) wearing KAFO with artificial muscles turned off, 3) wearing KAFO powered only in plantaflexion under feedforward control, and 4) wearing KAFO powered both in plantaflexion and knee extension under feedforward control. We collected surface electromyography, foot pressure and kinematics of ankle and knee joint. The experimental result showed that a muscular strength of wearing KAFO powered plnatarfexion and knee extension under feedforward control was measured to be lower due to pneumatic assistance and foot pressure of wearing KAFO powered plnatarfexion and knee extension under feedforward control was measured to be greater due to power assistance. In the result of motion analysis, the ankle angle of powered KAFO in terminal stance phase was found a peak value toward plantaflexion and there were difference of maximum knee flexion range among condition 2, 3 and 4 in mid-swing phase. The current orthosis design provided plantaflexion torque of ankle jonit in terminal stance phase and knee extension torque of knee joint in mid-swing phase.