• Title/Summary/Keyword: suture hook

Search Result 18, Processing Time 0.021 seconds

Modified Inside-Out Suture Technique for Meniscus Repair (변형된Inside-Out 술식을 이용한 반월상 연골 봉합술)

  • Ahn Jin-Hwan;Wang Joon-Ho;Yoo Jae-Chul;Kim Hyung-Gun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.2
    • /
    • pp.118-123
    • /
    • 2002
  • Purpose: To report modified technique of inside-out suture in repair of tear of postero medial corner of medial meniscus. Operative technique: Arthroscope is placed through anterolateral portal. Suture hook is delivered through anteromedial portal. By rotating the suture hook, it penetrates the inner portion of the torn meniscus from femoral surface to tibial surface of the meniscus for vertically oriented suture. A PDS suture is delivered through the lumen of suture hook, and the suture hook is withdrawn. The both ends of the suture are retrieved through anteromedial portal by a retriever, either grasper or crochet hook.A Zone-specific cannula is positioned below the inferior surface of the meniscus through anterolateral portal. The Looped Needle designed by the authors is delivered through the lumen of the Zone-specific cannula. The suture end of the tibial surface is placed in the loop of the Looped Needle and pulled out to the surface of posteromedial joint line. The suture end of the femoral surface is pulled out in same manner. A transverse skin incision of 1cm size is made adjacent to pulled out suture and the suture is tied. Discussion: Even though modified inside-out suture technique requires longer operation time than conventional inside-out technique, it provides vertically oriented suture and good tissue coaptation. The authors recommend this modified inside-out suture technique to be good alternative in repairing tear of the posteromedial corner of medial meniscus.

  • PDF

Arthroscopic Treatment of Tibial Spine Fracture using Suture Hook and pull-out PDS (Suture Hook과 pull-out PDS를 이용한 경골극 골절의 관절경적 치료)

  • Lee, Young Kuk;Kim, Joon Seok;Sohn, Sung Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.132-137
    • /
    • 1999
  • Displaced tibial spine fractures need the anatomical reduction of the displaced bone fragment to achieve normal range of motion and anterior stability of the knee joint. The purpose of this paper is to describe details of arthroscopic technique using suture hook and pull-out PDS and to evaluate the clinical results. We report 7 cases who underwent arthroscopic reduction and internal fixation using suture hook and pull-out PDS. All cases had fresh fractures generated within 3 weeks. The follow up period was at average 16.6 months. The fracture union was achieved at average 7.4 weeks. Knee exercise was started 2 weeks after the operation. One of the patients, who had combined injury of posterior cruciate ligament and lateral meniscus, showed limitation of knee movement. But he was underwent the arthroscopic fibrolysis at one year later, he returned to normal range of motion. Arthroscopic treatment of displaced tibial spine fracture using suture hook and pull-out PDS showed good results including rigid fixation and early mobilization. Therefore it is thought to be one of the effective operative techniques in treatment of the tibial spine fractures.

  • PDF

Single -portal Subscapualrs tendon repair

  • Choe, Chang-Hyeok;Kim, Sin-Geun;Jang, Ho-Jin;Chae, Seong-Beom
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2008.03a
    • /
    • pp.179-179
    • /
    • 2008
  • For a partial tear of the subscapularis tendon, the presenting technique requires only the anterior portal for preparing the footprint and suture management, as well as the subclavian portal for placing the suture anchor and suture hook without inserting a cannula. It provides both a good angle for anchor placement and sufficient space for managing the upper portion of a subscapularis tendon tear. A spinal needle was inserted through the subclavian portal in order to identify the appropriate angle for placing the suture anchor. A 3-mm incision was made for the subclavian portal and a biosuture anchor was placed on the footprint portion of the subscapularis tendon. In order to avoid crowding, each limb of both strands of the biosuture anchor were passed through the tendon- posteromedial side first, and anterolateral side second, using a switching technique with suture hook embedded with no.1 PDS. A suture tie was applied in a reverse sequence (the lateral strand first and the medial strand second) through the anterior cannula using a sliding technique.

  • PDF

Advantages of Scorpion Suture Passer and 70 Degrees Arthroscope in Arthroscopic Bankart Repair: Usefulness for Inferior Labral Repair

  • Hyun, Yoon-Suk;Shin, Woo-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.201-207
    • /
    • 2017
  • Background: The blunted tip of a reusable with multiple uses can cause problems with the passing procedure in arthroscopic Bankart repair. This study assessed the advantage of Scorpion with a $70^{\circ}$ arthroscope in arthroscopic Bankart repair compared to hook typed suture passer. Methods: Scorpion in 19 patients, the hook type suture passer (conventional group) in 18 patients were used. All patients underwent the same procedure except for the type of suture passer used. Another different point of the procedure were telescopes and the number of portals used; three arthroscopic portals (posterior, anterorsuperiorlateral, and mid-anterior) and a $30^{\circ}$ arthroscope in the conventional group, but two portals and a $70^{\circ}$ arthroscope as well as the $30^{\circ}$ one in the Scorpion group. The surgery time and the surgical complications including an iatrogenic axillary nerve injury were recorded. Results: The Scorpion group showed a significant decrease in surgery time compared to the conventional group. In contrast to the conventional group, Scorpion provided an easy estimation of the exit of suture passing, no iatrogenic labral injury during the passing procedure with straight movement and the sharp tip of the knife installed. Iatrogenic supraspinatus injuries could be avoided when making an accessory anteosuperiorlateral portal due to the $70^{\circ}$ arthroscope. Conclusions: In arthroscopic Bankart repair, the use of the Scorpion suture passer and a $70^{\circ}$ arthroscope can reduce the surgery time, avoid unnecessary supraspinatus injury, and avoid iatrogenic axillary nerve damage through the relatively easy and precise suture passing and saving of the anterosuperior portal.

Hook Plate Fixation for Isolated Greater Tuberosity Fractures of the Humerus

  • Lee, Kyoung-Rak;Bae, Ki-Cheor;Yon, Chang-Jin;Cho, Chul-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.222-229
    • /
    • 2017
  • Background: The purpose of this study was to investigate the outcomes after fixation using a 3.5-mm locking compression plate (LCP) hook plate for isolated greater tuberosity (GT) fractures of the proximal humerus. Methods: We evaluated the postoperative radiological and clinical outcomes in nine patients who were followed up at least 1 year with isolated GT fractures. Using the deltopectoral approach, we fixed the displaced GT fragments with a 3.5-mm LCP hook plate (Synthes, West Chester, PA, USA). Depending on the fracture patterns, the hook plate was fixed with or without augmentation using either tension suture or suture anchor fixation. Results: All the patient showed successful bone union. The mean time-to-union was 11 weeks. The radiological and clinical outcomes at the final follow-up were generally satisfactory. The mean visual analogue scale for pain, the University of California at Los Angeles score, the American Shoulder and Elbow Surgeons score, and the subjective shoulder value were 1.4, 30.3, 84.3, and 82.2%, respectively. The mean active forward flexion, abduction, external rotation, and internal rotation of the shoulder were $156.7^{\circ}$, $152.2^{\circ}$, $61.1^{\circ}$, and the 10th thoracic vertebral level, respectively. Only one patient presented with a postoperative complication of shoulder stiffness. The patient was treated through arthroscopic capsular release on the 5th postoperative month. Conclusions: We conclude that fixation using 3.5-mm LCP hook plates for isolated GT fractures of the proximal humerus is a useful treatment method that provides satisfactory clinical and radiological outcomes.

Anteroinferior Capsulolabral Complex Repair Using Antegrade Suture Passer - Technical Note - (Antegrade Suture Passer를 이용한 전하방 관절낭-관절와순 복합체의 복원술 - 수술 술기 -)

  • Seo, Hyuk-Jun;Cho, Chul-Hyun;Lee, Si-Wook
    • Journal of the Korean Arthroscopy Society
    • /
    • v.17 no.1
    • /
    • pp.95-99
    • /
    • 2013
  • We introduce arthroscopic Bankart repair technique using antegrade suture passer that can effectively restore detached anteroinferior capsulolabral complex for shoulder anterior instability. After diagnostic arthroscopy is performed using posterior, anteroinferior and anterosuperior portals, we confirm Bankart lesion and perform debridement and decortications of anteroinferior glenoid edge and neck. Suture anchor is inserted through anteroinferior portal at 2 mm medial side of glenoid edge (4:30 direction). Scorpion$^{TM}$ loaded suture is directly advanced to detached and retracted anteroinferior capsulolabral complex and the suture is passed at 10~15 mm medial side of detached anteroinferior capsulolabral complex (5:30 direction). The suture is retrieved by Scorpion's hook and then is tied using samsung medical center (SMC) sliding knot technique. Then suture anchors are serially inserted (2:30, 3:30) and capsulolabral complex repair is performed using suture hook and suttle-relay technique. This technique that can obtain anatomical restoration of anteroinferior glenohumeral ligament with proper tension is useful technique to reduce postoperative recurrence and makes it possible for less experienced surgeons.

  • PDF

Arthroscopic All Inside Repair of Lateral Meniscus Root Tear -Technical note- (외측 반월상 연골 경골 후방 부착부 파열의 관절경적 All-Inside 봉합술 - 수술술기 -)

  • Ahn, Jin-Hwan;Lee, Dong-Hoon;Chang, Moon-Jong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.1
    • /
    • pp.63-68
    • /
    • 2007
  • Purpose: The authors introduce a new technique of arthroscopic all inside repair using anterolateral and anteromedial portals for lateral meniscus root complete radial tear in patients who underwent concurrent anterior cruciate ligament (ACL) reconstruction. Operative technique: Arthroscope is placed through anteromedial portal and suture hook ($Linvatec^{TM}$, Largo, Florida, USA) is delivered through anterolateral portal. By rotating the suture hook, it penetrates posterior horn of the torn meniscus from femoral to tibial surface for vertical orientation. PDS No. 1 ($Ethicon^{TM}$, Somerville, NJ, USA) is delivered through the suture hook, and then it is withdrawn. Both end of PDS No. 1 are taken out through the anterolateral portal. MAXON 2-0 ($Syneture^{TM}$, Norwalk, Connecticut, USA) is used to penetrates remnant of tibial attachment of the torn meniscus from tibial to femoral surface in a same manner. MAXON 2-0 is changed for PDS No. 1 from tibial to femoral surface by shuttle relay technique. PDS No. 1 is tied using SMC (Samsung Medical Center) knot. Conclusion: All inside repair is a useful technique to achieve anatomical repair and to restore the hoop tension in lateral meniscus root complete radial tear.

  • PDF

The suture bridge transosseous equivalent technique for Bony Bankart lesion

  • Choe, Chang-Hyeok;Kim, Sin-Geun;Baek, Seung-Hun;Sin, Dong-Yeong
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2008.03a
    • /
    • pp.178-178
    • /
    • 2008
  • In order to improve static stability and healing of reattached labrum, we combined the advantages of suture bridge and transosseous technique. Using the conventional 3 portal for anterior instability, check stability of bony Bankart and preparation of glenoid bed in 3 way including removal, reshaping or mobilization of bony fragment. Two anchors were inserted to the superior and inferior portion and medial edge of bony Bankart lesion. It usually corresponded to the area of IGHL. Medial mattress sutures were applied around IGHL complex to get enough depth of glenoid coverage using suture hook. Make 3.5mm pushlock anchor hole to the articular edge of glenoid cartilage. Proximal suture bridge was applied at first and then distal suture bridge was inserted to mobilize the labrum in proximal direction. These construction can provide more stable labral repair with wide contact and compression in case of deficient bony stability. It not only avoids technical disadvantage of point contact with anchor fixation, but also decreasing gap formation through cross compression of labrum that couldn't gain even with the transosseous fixation which affords linear compression effect. Additional bony stability could be gained if the the bony fragment was mobilized to the glenoid margin with potential healing bed or reshaped for the good contact with reattached labrum.

  • PDF

Arthroscopic Capsular Repair without Relaying Sutures: 'Simple Sewing Technique'

  • Kim, Hyungsuk;Song, Hyun Seok;Kang, Seung Gu;Han, Sung Bin
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.3
    • /
    • pp.146-148
    • /
    • 2019
  • We report a simple technique for repairing capsular tear, using only a hook-like, cannulated instrument and braided sutures without relaying steps. A No. 2 braided suture is passed through the lumen of the instrument. Under direct arthroscopic view, the tip of the instrument is passed through the side of the capsule that has previously been separated with the probe. One end of the suture is retrieved with a grasper through a separate portal. The tip is moved back without withdrawing through the skin, and reinserted into the other side of the capsule. Holding the end retrieved earlier, the other end of the suture is retrieved with a suture retriever. After complete removal of the instrument, the suture is tied through a cannula using the standard knot tying techniques. The same procedures are repeated for other required knots.

Arthroscopic Reduction of Subluxed Medial Meniscus using Suture Anchor for Restoration of Hoop Stress - Technical Note - (버팀테응력 회복을 위한 아탈구된 내측 반월상 연골의 Suture anchor를 이용한 정복술 - 술기 보고 -)

  • Kim, Jaw-Hwa;Lee, Yoon-Seok;Kim, Chul;Han, Seung-Chul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.3
    • /
    • pp.280-284
    • /
    • 2009
  • Purpose: The authors introduce a new technique of arthroscopic reduction of subluxed medial meniscus using suture anchor for the restoration of hoop stress. Operative Technique: Anterolateral, anteromedial, and medial midpatellar arthroscopic portal are used. Arthroscope was inserted through anterolateral portal. Through the scope, we confirmed subluxation of medial meniscus. Transection of menisci including radial and root tear were excluded. We released the anterior horn of medial meniscus through anteromedial and burred the future insertion site of suture anchor. After inserting suture anchor through medial midpatellar portal, we used 90 degree suture hook and no.2 Nylon to retrieve the suture of inserted anchor. We tied the suture by sliding knot-tying method. Weight bearing was limited for 6 weeks postoperatively. Conclusion: Arthroscopic retightening of medial meniscus is less invasive, conserving and progressed method for subluxed meniscus.

  • PDF