• Title/Summary/Keyword: suspended particulate matter

Search Result 142, Processing Time 0.025 seconds

Trace Metals of Ambient TSP in Daegu Area (대구지역 총 부유분진중 중금속)

  • 이찬형
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.67-73
    • /
    • 2003
  • This study was carried out to characterize the behavior and sources of particulate trace metal in Daegu city. TSP (Total Suspended Particulate matter) was collected by filters on High Volume Air Sampler from the four areal (reference, residential, commercial, industrial area). The moult were analyzed by AAS after preliminary treatment. The average centration trend of trace metals contained in TSP was shown as follows : Fe > Cu > Pb > Mn > Ni > Cr > Cd. The trace metals showed the highest concentration in the industrial area. This study showed the seasonal variation of trace metals. Fe and Mn showed high concentration in spring, whereas Cr, Ni, Cd and Pb showed high concentration in winter. Also this study showed the regional variation of trace metals. The order of the average concentration of trace metals was : industrial > commercial > residential > reference area. Using Mn as a reference element, the enrichment factor analysis were used for identifying the trace element contributors. The enrichment factors of Cr, Fe < 10 were considered to have a significant dust and soil source and termed nonenriched. Pb, Cd, Cu >>10 were enriched and had a significant fraction which was contributed by anthropogenic sources.

간척지, 해안가 근처의 농업용수 공급을 위한 기수담수 시스템 연구

  • Hong, Min
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.57 no.4
    • /
    • pp.16-24
    • /
    • 2015
  • Desalination technology is a process to remove salt from water. There are three classified In accordance with the concentration of salt The concentration of sea water 15,000~50,000mg/l, brackish water 1,500~15,000mg/l, desalination less than 500mg/l.. In general, salt to remove for using a pre-treatment UF filter, but this study is new pre-treatment technology RO Membrane process technology Suspended particulate matter is said most were treated at the pre-treatment equipment, wheat affluent particulate material was removed from the MF filter. Influent SS 16.2mg /l The treatment was effective in treatment 0.05mg /l of 99% is removed. COD is reduced to 60% in the pre-treatment device, after treatment was reduced to 30% RO membrane. Influent COD 10.2mg/l treatment was removed 1.9mg/l. The removal rate is 81.9%. Desalination removes the ionic substances in the RO Membrane. Influent EC $978.8{\mu}s/cm$ and treatment showed a result of $18.7{\mu}s/cm$.

Source Characterization of Suspended Particulate Matter in Taegu Area, Using Principal Component Analysis Coupled with Multiple Regression (주성분/중회귀분석을 이용한 대구지역 대기중 부유분진의 발생원별 특성평가)

  • 백성옥;황승만
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.3
    • /
    • pp.179-190
    • /
    • 1992
  • This study was carried out to characterize sources of atmospheric total suspended particulates (TSP) in urban and sub--urban areas of metropolitan taegu. The sources were tentatively identified by a multivariate technique, i.e. principal component analysis (PCA), and the source contributions to the atmospheric concentrations of TSP were further estimated by stepwise multiple regression analysis. A total of 5 sources was identified in the urban area of Taegu (soil dust resuspension, fuel combustion, secondary aerosol, traffic related aerosol, and refuge burning), while 4 sources were found to be significant in the sub--urban area as following: fuel combustion/secondary aerosol, soil dust resuspension, traffic related aerosol, and wood/agricultural burning. The largest contributor to the atmospheric TSP appeared to be the soil dust resuspension in both areas. The source apportionment of the extractable organic matter (EOM) was also carried out for the Taegu data. The EOM was determined with respect to the solvent polarity, i.e. cyclohexane (non-polar), dichloromethane (semi--polar), and acetone (polar). In addition, the source profiles for the TSP in Taegu area were estimated using a PCA-based algorithm, and the validity was evaluated tentatively by comparing the data in the literature.

  • PDF

Effect of Anion Generating Air Cleaner on the Components of ETS in a Closed Room (음이온 발생 공기청정기에 의한 밀폐된 실내공간에서의 ETS성분 변화)

  • Hwang, Keon-Joong;Rhee, Moon-Soo;Ra, Do-Young
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.20 no.1
    • /
    • pp.124-130
    • /
    • 1998
  • This study was conducted to evaluate the ability of anion generating air cleaner to remove gases, vapor and particles from closed room contaminated with environmental tobacco smoke (ETS). The measurements covered particle sizes of 13.8-542.5nm, particle concentration, surface area, volumes UVPM, FPM, solanesol, and the following gases and vapor; carbon dioxide, carbon monoxide, nicotine, and 3-ethenylpyridine. Tobacco smoke was generated and mixed in a closed room in which the airflow rates were in the range of 0.00-0.04 m/s. The anion generating air cleaner was startedl and the decay rates for the gases, vapor and particles were measured, When the use of anion generating air cleaner, solid components of ETS, such as respirable suspended particle (RSP), utraviolet particulate matter (UVPM, fluorescent particulate matter (FPM) and solanesol was sharply decreased, and vapor phase components of ETS, such as nicotines 3-ethenylpyidine were modelately decreased by time elapse. Even the use of anion generation air cleaner, the decreasing rate of carbon dioxide concentration was similar with control, and the decreasing rate of carbon monoxide was slower than that of control. Our results indicated that the use of anion generting air cleaner had an effect on reduction of solid and vapor components from ETs, but it had no effect on gaseous components of ETS.

  • PDF

Exposure to Fine Particle along Different Commuting Routes in Urban Area of Fukuoka, Japan

  • Ma, Chang-Jin
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.205-213
    • /
    • 2015
  • The objective of the current study was to assess the comparative risk associated with exposure to particulate matter (PM) while commuting via different public transport modes in Fukuoka, Japan. For the given routes and measuring days, a trip-maker carried a lightweight portable bag loaded the real-time measurement devices which take simultaneous measurement for size-fractioned particle number concentration, $PM_{2.5}$ mass concentration, and total suspended particle (TSP) collection. The results of the present study have shown significant differences between public transports as commuting modes in Fukuoka. The PM exposure levels on subway platform and inside subway train were overwhelmingly higher than those of other points on commuting route. The relative ratio between modes (i.e., the ratio of $PM_{2.5}$ inside subway to that inside bus) provides an idea for choosing a right commuting mode for our health. This study clearly provided evidence of the extremely high levels of iron exposure by subway uses compared to bus uses. The result of theoretically reconstructed mass concentration of $PM_{2.0-0.3}$ collected on subway platform suggests that the PM of underground subway will be associated with PM both generated in subway system and inleakaged from outdoor environment.

Recycling of Suspended Particulates by Atmospheric Boundary Depth and Coastal Circulation

  • Choi, Hyo
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.19-26
    • /
    • 2003
  • The dispersion of recycled particulates in the complex coastal terrain containing Kangnung city, Korea was investigated using a three-dimensional non-hydrostatic numerical model and lagrangian particle model (or random walk model). The results show that particulates at the surface of the city that float to the top of thermal internal boundary layer (TIBL) are then transported along the eastern slope of the mountains with the passage of sea breeze and nearly reach the top of the mountains. Those particulates then disperse eastward at this upper level over the coastal sea and finally spread out over the open sea. Total suspended particulate (TSP) concentration near the surface of Kangnung city is very low. At night, synoptic scale westerly winds intensify due to the combined effect of the synoptic scale wind and land breeze descending the eastern slope of the mountains toward the coast and further seaward. This increase in speed causes development of internal gravity waves and a hydraulic jump up to a height of about 1km above the surface over the city. Particulate matter near the top of the mountains also descends the eastern slope of the mountains during the day, reaching the central city area and merges near the surface inside the nocturnal surface inversion layer (NSIL) with a maximum ground level concentration of TSP occurring at 0300 LST. Some particulates were dispersed following the propagation area of internal gravity waves and others in the NSIL are transported eastward to the coastal sea surface, aided by the land breeze. The following morning, particulates dispersed over the coastal sea from the previous night, tend to return to the coastal city of Kangnung with the sea breeze, developing a recycling process and combine with emitted surface particulates during the morning. These processes result in much higher TSP concentration. In the late morning, those particulates float to the top of the TIBL by the intrusion of the sea breeze and the ground level TSP concentration in the city subsequently decreases.

  • PDF

Seasonal Variation of the Quantity and Quality of Seston as Diet Available to Suspension-Feeders in Gosung and Kangjin Bays of Korea (고성만과 강진만에서 현탁물 섭식자에 유용한 입자물질 양과 질의 계절 변동)

  • LEE Pil-Yong;KANG Chang-Keun;CHOI Woo-Jeung;YANG Han-Seob
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.4
    • /
    • pp.340-347
    • /
    • 2001
  • Seasonal variation of the elemental and biochemical composition of the suspended particulate matter (SPM) was investigated in terms of quantity and quality of diets for suspension feeders from July 1999 to August 2000 in two coastal bay systems of Gosung and Kangjin Bays in Korea. No clear patterns in the seasonal variations of SPM concentration were found in these two bay systems. The results indicated that the seasonal variation of SPM could not be considered the variation of food available to suspension-feeders. The simultaneous peaks in chlorophyll a and biochemical components in summer indicated that the quantity of the particulate organic matter primarily depended on phytoplankton productivity. However, no correlation between chlorophyll a and biochemical components [particulate protein (PPr), carbohydrate (PCHO) and lipid] were found, indicating that other processes might also contribute to the particulate organic matter in the period when the phytoplankton biomass was low. High C: Chl a and C:N, and carbohydrate peaks during the autumn to spring period suggested that resuspension of surface sediments was a probable process to supply the particulate organic matter. The food material, represented by summing up the total quantity of three biochemical components, was highest in spring with minor peaks during the period from autumn to the next spring, The food index, calculated as the ratio of food material to total SPM, did not generally exceed $6\%$ with short peaks during the year. Therefore, nutritional quality of SPM in the bays are relatively poor than in other more productive coastal waters in the world. Our results confirm that the measurement of a single chemical variable cannot describe fully the nutritive value of the seston available to suspension-feeders as previously proposed, and the biochemical composition of SPM can provide effective information on its origin and nutritive Quality.

  • PDF

Characterization of Fine Dust Collection Using a Filter Ventilation (환기장치와 필터를 활용한 미세먼지 제거특성 조사)

  • Jeon, Tae-Yeong;Kim, Jae-Yong
    • Applied Chemistry for Engineering
    • /
    • v.26 no.2
    • /
    • pp.229-233
    • /
    • 2015
  • In this study, we examined the removal characteristics of suspended particulate matters which are one of carcinogens to cause lung cancer. The fine dust capture by a pilot scale filtration system depends on several important variables such as humidity, initial fine dust injection volume, and flow rate. The average concentration of particulate matters in the test chamber decreased, but the ultimate collection efficiency did not change during the filtration under high humidity, compared to those of using ambient conditions The initial injection amount of fine dust did not influence the particle capturing efficiency. When the flow rate reduced from 0.6 m/s to 0.3 m/s, the dust collection time increased approximately 1.4 times. Among all variables tested, the flow rate showed the most significant effect on the removal efficiency of fine particulate matter.

An Application of $^{13}C$ Tracer for the Determination of Primary Productivity and Fatty Acid Production Rate in Shingu Reservoir (신구저수지의 1차 생산 및 지방산 생성속도 결정을 위한 $^{13}C$ 추적자 활용 연구)

  • Lee, Yeon-Jung;Kim, Min-Seob;Shin, Kyung-Hoon;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.spc
    • /
    • pp.21-26
    • /
    • 2008
  • The in situ incubation experiment was carried out using $^{13}C$ tracer to determine primary productivity and fatty acid production rate in the shallow, eutrophic Shingu reservoir on 4th July. Particulate organic matter (POM) accounted for 76% in suspended particulate matter (SPM), and average concentration of chlorophyll-${\alpha}$ was $89{\mu}g\;L^{-1}$ in the euphotic layer. Total amount of chlorophyll-${\alpha}$ (Chl-${alpha}$), primary productivity and Chl-${alpha}$ specific productivity in euphotic layer were 112 mg Chl-${alpha}m^{-2}$, 3.53 g C $m^{-2}\;d^{-1}$, 32mg C mg Chl-${\alpha}^{-1}\;d^{-1}$, respectively. The fatty acid composition in newly produced organic matter and suspended organic matter didn't show any significant difference, demonstrating that autochthonous organic matter should be a major source of POM pool. In addition, the fatty acids of bacterial origin were increased through extracellular release of newly photosynthesized DOC, and closely coupled with bacterial assimilation. This result suggests that organic carbon should be actively cycled through the microbial loop in Shingu reservoir in summer.

Spatiotemporal Variations and Possible Sources of Ambient PM10 from 2003 to 2012 in Luzhou, China

  • Ren, Dong;Li, Youping;Zhou, Hong;Yang, Xiaoxia;Li, Xiaoman;Pan, Xuejun;Huang, Bin
    • Environmental Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.331-338
    • /
    • 2014
  • Descriptive statistics methods were used to study the spatiotemporal variations and sources of ambient particulate matter ($PM_{10}$) in Luzhou, China. The analyzed datasets were collected from four national air quality monitoring stations: Jiushi (S1), Xiaoshi (S2), Zhongshan (S3), Lantian (S4) over the period of 2003-2012. This city was subjected serious $PM_{10}$ pollution, and the long-term annual average $PM_{10}$ concentrations varied from 76 to $136{\mu}g/m^3$. The maximum concentration was more than 3-fold of the annual average ($40{\mu}g/m^3$) issued by EPA-China for the ambient air quality. General temporal pattern was characterized by high concentrations in winter and low concentrations in summer, and general spatial gradient was in the reduction order of S2 > S4 > S3 > S1, which were both due to different particulate contributors and special meteorological conditions. The source apportionment indicated that vehicular emissions, road dusts, coal burning and chemical dusts were the major contributors of the identified $PM_{10}$ pollution, and the vehicular emissions and the road wear re-suspended particles dominated the heavy $PM_{10}$ pollution in recent years. Two other potential sources, agricultural and celebration activities could decrease the air quality in a short term. Finally, some corresponding suggestions and measures were provided to improve the air quality.