• Title/Summary/Keyword: susceptibility test

Search Result 872, Processing Time 0.027 seconds

HEMP Effect Analysis for Equipment Using Comparison of Norms between HEMP Filter Residual Current and Conducted Susceptibility Criteria (HEMP 필터 잔류 전류와 전도 내성 기준의 특성인자 비교를 통한 장비의 HEMP 영향성 분석)

  • Kwon, Joon-Hyuck;Song, Ki-Hwan;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.2
    • /
    • pp.199-207
    • /
    • 2014
  • Although High-altitude electromagnetic pulse(HEMP) protection filter meets the requirements of pulsed current injection(PCI) acceptance test, the equipment under test which has low electromagnetic susceptibility level can be damaged during PCI verification test that is performed on operating condition of equipment. This paper proposed the HEMP effect analysis method using comparison of norms between residual current of HEMP filter and transient electromagnetic conducted susceptibility criteria of equipment, as an alternative method under the condition that performing PCI verification test is limited in HEMP hardened facilities. PCI acceptance test of HEMP filter, transient electromagnetic conducted susceptibility test, and PCI verification test are performed and test results are analyzed.

Research of the EMI Test Methods for a Surveillance Radar Subsystem Against the Intermodulation and Undesired Signals (상호 변조 및 불요 신호에 대한 탐색레이더 부 체계의 EMI 시험 기법)

  • Lee, Jin-Ho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.84-89
    • /
    • 2007
  • MIL-STD-461E, EMI military standard for the equipment and subsystems, requires reception characteristic tests to verify the susceptibility of a receiver against the jntermodulation and spurious signals. Because the CS103 and CS104 of MIL-STD-461E show the test configuration of the equipment unit like a traditional receiver, it is possible to verify the susceptibility only for the reception signal through analog filters. However, at present when software programming techniques make a progress, the CS103 and CS104 tests need to evaluate the reception signal of the subsystem which includes both the digital filtering effects and analog filter characteristics. These test and evaluation techniques applied to a surveillance radar subsystem. This paper researched the EMI test methods in order to confirm feasibility of these test and evaluation techniques. Also the test results are compared and analyzed.

A Study on Stress Corrosion Cracking Evaluation with Material Degradation of High Temperature Components (고온부재의 재질열화에 따른 응력부식균열 평가에 관한 연구)

  • Park, Jong-Jin;Yu, Ho-Seon;Jeong, Se-Hui
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1123-1132
    • /
    • 1996
  • It has been reported that high temperature structural components represent the phenomenon of material degradation according to a long term service under high temperature and pressure. Especially, fossile power plant components using the fossil fuel and heavy oil are affected by dewpoint corrosion of $H_2SO_4$produced during a combustion. Therefore, the service materials subjected to high temperature and pressure may occur the stress corrosion cracking. The object of this paper is to investigate SCC susceptibility according to the material degradation of the high temperature structural materials in dewpoint corrosive environment-$H_2SO_4$.The obtained results are summarized as follows : 1) In case of secondary superheater tube, the fractograph of dimple is observed at the concentration of $H_2SO_4$-5%. When the concentration of $H_2SO_4$ is above 10%, the fracture mode is shifted from a transgranular fracture to an quasi-intergranular fracture according to the increment of concentration. 2) In the relationship between [$\Delta$DBTT]$_sp$ and SCC susceptibility, it is confirmed that the greater material degradation degree is, the higher SCC susceptibility is. In addition, it can be known that SP test is useful test method to evaluate SCC susceptibility for high temperature structural components. 3) When [$\Delta$DBTT]$_sp$ is above 17$17^{\circ}C$ the SCC fracture behavior is definitely observed with SCC susceptibility of above 0.4.

Results of Secondary Antibiotics Susceptibility Test for Gram Negative Bacilli Resistant to Primary Susceptibility Test in Yeungnam University Hospital (기본 항생제에 내성을 보인 그람 음성 간균에 대한 2차적 항생제 감수성 검사 결과)

  • Kim, Chung-Sook;Kim, Kyung-Dong;Lee, Chae-Hoon
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.28-36
    • /
    • 1993
  • Major pathogenic Gram-negative organisms such as P. aeruginosa, Serratia species, E. coli, Enterobacter species which are isolated from the specimens in large medical centers are greatly resistant to the commonly used antibiotics. Gram-negative bacilli, which had been isolated in Yeungnam University Hospital during the period from December 1992 to April 1993 and turned out to be resistant to the primary antibiotics susceptibility test for chloramphenicol, ampicillin, cephalothin, gentamicin, tetracyclin, amikin and tobramycin, were subjected to the secondary antibiotics susceptibility test for aztreonam, ceftazidime, ciprofioxacine, cefotaxime, cefamandole, piperacillin, ticarcillin and sulfamethoxazole trimethopime. Out of 315 tested organisms, 167 organisms(53%) were resistant to all secondary antibiotics in vitro. Antimicrobial activity of ceftazidime(37.1%), aztreonam(11.%), ciprofioxacine(7.9%) against Gram negative bacilli were slightly more active than other antibiotics tested, while cefamandole was not active to all the Gram-negative bacilli tested. According to the specimens, E. coli was the most frequently resistant organisms to the primary antibiotics from urine, A. baumanii, from respiratory system and wounds, and P. aeruginosa from various specimens. In summary, Gram negative bacilli resistant to the primarily applied antibiotics also were resistant to the secondary antibiotics. Rearrangement of the antibiotics disks for the antibiotic susceptibility test should be considered.

  • PDF

Antifungal Susceptibility Testing for the Dermatophytes Isolated from Dogs and Cats (개와 고양이에서 분리한 피부사상균에 대한 항진균제의 감수성시험)

  • Shin, Jae-Eun;Sung, Choong-Hyun;Kim, Doo
    • Journal of Veterinary Clinics
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2001
  • The aim of this study was to determine optimal therapeutic dose of antifungal agents for dermatophytes. Forty nine dermatophytes were isolated form dogs and cats showing skin lesions and were tested for their in vitro susceptibility to nystatin, griseofulvin, terbinafine, ketoconazole and fluconazole by broth microdilution test. Terbinafine showed the lowest MIC value among the antifungal agents tested, and MIC values ranged from 0.002 to 0.016 $\mu\textrm{g}$/ml. Fluconazole showed the highest MIC values among the antifungal agents tested, and MIC values ranged from 32 to 512 $\mu\textrm{g}$/ml. MIC values of nystatin, griseofulvin and ketoconazole ranged from 1.12 to 4.48 $\mu\textrm{g}$/ml, 0.5 to 4.0 $\mu\textrm{g}$/ml, and 1.6 to 12.8 $\mu\textrm{g}$/ml, resistant to griseofulvin, and that antifungal susceptibility test was needed to determine optimal therapeutic dose of antifungal agents for each dermatophyte.

  • PDF

EMC Test of Deimos-2 satellite (Deimos-2 위성 EMC 시험)

  • Park, In-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.10
    • /
    • pp.878-883
    • /
    • 2014
  • This paper presents the test result of system level EMC of LEO satellite Deimos-2 FM that has been launched in June 20, 2014. The Deimos-2 satellite was designed considering the EMC of unit modules level in addition to the structure aspects. The Auto-Compatibility, Radiated Emission and Radiated Susceptibility test was conducted. The test result has meet the standard of system EMC of Deimos-2 program.

Module level EMC verification method for replacement items in nuclear power plant

  • Hee-Taek Lim;Moon-Gi Min;Hyun-Ki Kim;Gwang-Hyun Lee;Chae-Hyun Yang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2407-2418
    • /
    • 2023
  • Internal replaceable electronic module substitutions can impact EMC (ElectroMagnetic Compatibility) qualification testing and results if EMC testing is conducted at the cabinet level. The impact of component substitutions on EMC qualification results therefore should be evaluated. If a qualitative evaluation is not adequate to ensure that the modified product will not impact the cabinet level EMC qualification results, a new qualification testing should be conducted. Component level retesting should be conducted under electromagnetically equivalent conditions with the cabinet level test. This paper analyzes the propagation of conducted susceptibility test waveforms in a representative cabinet and evaluates the impact of component substitutions on cabinet level EMC qualification results according to the location of the replacement items. A guideline for a qualitative evaluation of the impact of component substitutions is described based on the propagation of the conducted susceptibility test waveforms. A module level test method is also described based on an analysis of the shielding effectiveness of the cabinet.

Efficient Experimental Design for Measuring Magnetic Susceptibility of Arbitrarily Shaped Materials by MRI

  • Hwang, Seon-ha;Lee, Seung-Kyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.3
    • /
    • pp.141-149
    • /
    • 2018
  • Purpose: The purpose of this study is to develop a simple method to measure magnetic susceptibility of arbitrarily shaped materials through MR imaging and numerical modeling. Materials and Methods: Our 3D printed phantom consists of a lower compartment filled with a gel (gel part) and an upper compartment for placing a susceptibility object (object part). The $B_0$ maps of the gel with and without the object were reconstructed from phase images obtained in a 3T MRI scanner. Then, their difference was compared with a numerically modeled $B_0$ map based on the geometry of the object, obtained by a separate MRI scan of the object possibly immersed in an MR-visible liquid. The susceptibility of the object was determined by a least-squares fit. Results: A total of 18 solid and liquid samples were tested, with measured susceptibility values in the range of -12.6 to 28.28 ppm. To confirm accuracy of the method, independently obtained reference values were compared with measured susceptibility when possible. The comparison revealed that our method can determine susceptibility within approximately 5%, likely limited by the object shape modeling error. Conclusion: The proposed gel-phantom-based susceptibility measurement may be used to effectively measure magnetic susceptibility of MR-compatible samples with an arbitrary shape, and can enable development of various MR engineering parts as well as test biological tissue specimens.

Phenotypic characteristics and antimicrobial susceptibility of verotoxin -producing E coli from slaughtered cattle

  • Byun Jae-Won;Kim Kyoung-Ho;Lee Sung-Mo;Hwang Hyun-Soon;Kim Yong-Hee
    • Korean Journal of Veterinary Service
    • /
    • v.28 no.4
    • /
    • pp.407-412
    • /
    • 2005
  • Ten isolates of Verotoxin-producing Escherichia coli (VTEC) were detected in slaughtered cattle and investigated their phenotypic characteristics and antimicrobial susceptibility. None of the isolates was positive for eae gene. Only one isolate was positive for uidA gene. Eight out of ten isolates of VTEC were originated from broker's cattle. Thus microbiological monitoring for broker farms should be performed to minimize VTEC contamination. In the antimicrobial susceptibility test, all the isolates were highly resistant to bacitracin and lincomycin whilst they are susceptible to apramycin and neomycin.

Susceptibility Testing of Helicobacter pylori to Metronidazole and DNA Fingerprints of Resistant Strains in Singapore

  • HUA, JIESONG;KHAY-GUAN YEOH;PENGYUAN ZHENG;HAN CHONG NG;BOW HO
    • Journal of Microbiology and Biotechnology
    • /
    • v.9 no.3
    • /
    • pp.328-333
    • /
    • 1999
  • Susceptibility of 61 strains of Helicobacter pylori to metronidazole was examined by both the disk diffusion method using a cut-off of 15㎜ for resistance and the E test with a cut-off of 8㎎/l. The MIC/sub 50/ and MIC/sub 90/ by the E test were 2 ㎎/l and 256㎎/l, respectively. Metronidazole resistance was found in 22 (36%) out of the 61 H. pylori strains by the E test and in three additional strains by the disk diffusion method. Amongst the latter three isolates, the MICs by the E test were 4 ㎎/l, 6㎎/l, and 6㎎/l, respectively. These figures are one log₂ or half log₂ dilution lower than the cut-off of 8㎎/l recommended as resistance for the E test. All 22 metronidazole resistant H. pylori isolates by the E test that were subjected to random amplified polymorphic DNA (RAPD) fingerprinting showed different DNA fingerprints. Interestingly, >90% of resistant isolates possess two common DNA bands of 0.4 and 0.9 kb. This study demonstrates that the results of the disk diffusion method for testing H. pylori susceptibility to metronidazole correlates well with that of the E test. The criteria for interpretation need to be internationally standardized so that the results from different centers can be compared.

  • PDF