• 제목/요약/키워드: surgical incision

검색결과 505건 처리시간 0.032초

액와 단일절개 접근법을 이용한 내시경적 갑상선 절제술 (Gasless Endoscopic Thyroidectomy Via Single Incision Axillary Approach)

  • 김소영;유윤종;정우진;안순현
    • 대한두경부종양학회지
    • /
    • 제28권2호
    • /
    • pp.114-117
    • /
    • 2012
  • Background and Objectives : To assure the surgical completeness of the gasless endoscopic thyroidectomy via single incision axillary approach using flexible videoscope which provide wide angle and working space, we compared single incision axillary approach and axillo-areolar approach by means of clinical, surgical outcomes. Materials and Methods : From March 2011 to July 2012, 24 patients who had underwent endoscopic thyroidectomy via transaxillary approach were enrolled. Of total, 17 patients underwent single incision axillary approach(group I) and the other 7 underwent axillo-areolar approach(group II). Results : Patient demographics, surgical indications were similar between the two groups. The operating time(group I 144.6min, group II 153.6 min ; p=.29), blood loss(group I : 55.4cc, group II : 35.7cc : p=.64), hospital stay(group I : 4.2days, group II : 4.4 days ; p=.65) were similar in the two groups. Overall, two patients in group I(2/17, 11.8%) experienced postoperative complications, including one hematoma and one seroma. Due to narrow working space, one patient was change to axillo-areolar approach during single incision axillary approach with $30^{\circ}$ rigid endoscope. Conclusion:Single incision axillary approach is safe and effective similar to other endoscopic thyroidectomy methods using flexible videoscope. Different with $30^{\circ}$ rigid endoscope, 10-mm flexible videoscope can put inside the axillary inicision site in different axis with endoscopic instruments. This difference in endoscopic axis help to prevent crash with endoscopic instrument.

Supraorbital Keyhole Approach for Intracranial Aneurysms : Transitioning from Concerns to Confidence

  • Park, Jaechan
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권1호
    • /
    • pp.4-13
    • /
    • 2020
  • For surgical minimalism to reduce iatrogenic traumatization, a supraorbital keyhole approach has already been successfully applied to treat many unruptured anterior circulation aneurysms. However, using this minimal approach also raises several technical concerns due to the small cranial opening and cosmetic impact of a facial incision. Yet, such technical limitations can be overcome by using favorable surgical indications, slender surgical instruments, and optimized surgical techniques, while excellent cosmetic outcomes can be achieved using a short skin incision located <1 cm from the supraorbital margin, reconstruction of any bone defects around the bone flap, and meticulous wound closure. Thus, given such reassuring surgical results, in terms of the clipping status, neurological effects, and cosmetic outcomes, any concerns can be transitioned into confidence.

후두 및 하인두암 수술에 있어서 피부절개의 선택 (Choice of Skin Incision for Surgery of Laryngeal and Hypopharyngeal Cancer)

  • 최은창;공석철;김영호;김은서;홍원표
    • 대한두경부종양학회지
    • /
    • 제11권2호
    • /
    • pp.158-166
    • /
    • 1995
  • Planning of the skin incision is one of the most important point for safe removal of the head and neck cancer. The fact that so many types of incisions exist is strong testimony that there is hardly one incision that fits all situation. Factors that influence the choice are adequate exposure, changeability to other types of neck dissection, optimal exposure of the primary site and/or opposite side of the neck, and safety of the neck flap and cosmesis. Laryngeal and hypopharyngeal carcinomas are the most common tumor of the head and neck, even though there are so many diverse situation exist, there must be an optimal approach to each case. From 1992 to 1994 surgical approaches used for laryngeal and hypopharyngeal carcinoma at the Severance Hospital were reviewed. Types of surgical approaches, its pitfall, advantage and disadvantages were reviewed.

  • PDF

누두흉의 외과적 치료Metal bar 를 이용한 수술 1례 치험 (Surgical Correction of Funnel Chest by using Sulamaa`s metal strut)

  • 손동섭
    • Journal of Chest Surgery
    • /
    • 제18권3호
    • /
    • pp.492-496
    • /
    • 1985
  • Two cases of surgical correction of funnel chest using metal struts were presented. The main procedures of the method were transverse submammary incision, subperichondrial resection of the deformed costal cartilages, division of the xiphisternal joint, wedge osteotomy of the sternum, freeing of the posterior surface of the sternum and stabilization by means of 2 metal struts. The struts were removed postoperative 3 and 6 months by a small incision under the local anesthesia. The results in both patients were satisfactory. This method of correction is simple, easy to perform and free of any operative risks.

  • PDF

기관협착증 치험 3례 (Surgical Treatment of Tracheal Stenosis -Report of 3 Cases-)

  • 박철호;우종수;조광현
    • Journal of Chest Surgery
    • /
    • 제21권2호
    • /
    • pp.395-402
    • /
    • 1988
  • Increasing success in the management of patients with severe respiratory failure by mechanical respirators has produced iatrogenic tracheal stenosis. And the surgical management of these lesions have provided a major field for tracheal reconstructive surgery. Recently we have experienced three cases of postintubation tracheal stenosis between December, 1985 and October, 1987 and successfully performed circumferential resection and end to end anastomosis of the trachea. The lesion of the first case which was located in the subcricoid level was resected about 2cm length with cervical incision. And the lesion of the second case located at the cuff site was also resected about 2.5cm length with cervical and median sternotomy incision. Also the lesion of the third case located at the stoma site was resected about 1.8cm length with cervical incision. The postoperative courses were uneventful but there was extubation difficulty in the third case because of stupor mentality and problem of secretion excretion. So we have observed the postoperative course after T-tube insertion.

  • PDF

Robot-assisted submandibular gland excision via modified facelift incision

  • Jung, Seung Wook;Kim, Young Kwan;Cha, Yong Hoon;Koh, Yoon Woo;Nam, Woong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제39권
    • /
    • pp.25.1-25.6
    • /
    • 2017
  • Background: The conventional transcervical resection for submandibular gland disease has some risks and an unsatisfactory cosmetic result. Recently, robot-assisted surgery has been developed as a plausible substitute for conventional surgery which provides an excellent cosmetic outcome. Case presentation: The authors performed robot-assisted sialadenectomy via modified facelift incision using the da Vinci Xi surgical system (Intuitive Surgical Inc., CA, USA) with two endowrist arms (monopolar curved scissors and Maryland bipolar forceps) successfully in a 44-year-old female patient who suffered from sialolith and severe atrophic submandibular gland. Conclusions: If similar studies are done in the future, this robot-assisted sialadenectomy may become established as an alternative to existing disadvantageous surgical methods.

DBA/2 계열 마우스의 절개통증에서의 행동양상 (Incision-induced Pain Behaviors in the DBA/2 Mouse)

  • 배다현;박수석;우영철
    • The Korean Journal of Pain
    • /
    • 제21권1호
    • /
    • pp.18-26
    • /
    • 2008
  • Background: Because genetic manipulation is commonly accomplished in mice, mouse models for pain have advanced our understanding of the mechanisms of persistent pain. The purpose of this experimental study is to develop a mouse model for understanding incision induced postoperative pain. Methods: A longitudinal incision was made at the hindpaw of male DBA/2 mice. The withdrawal frequency(WF) from applications of von Frey filaments and the response frequency (RF) to blunt mechanical stimulation were examined in an incision group and a control grouP. The withdrawal latency (WL) to radiant heat and a pain score based on weight bearing were also measured. Tests were performed 1 day before incision, and 2 hours, 1-3 days, 5 days and 7 days after incision. Results: The WF for the strongest filament was $35.0{\pm}9.1%$ before incision and this increased to $100.0{\pm}0%$ at 2 hours and to $65.0{\pm}9.1%$ at 7 days after incision. The RF to the blunt stimulus was $4.1{\pm}4.1%$ before incision and $100.0{\pm}0.0%$ at 2 hours and $42.8{\pm}10.8%$ at 7 days after incision. The WL was $6.6{\pm}0.5sec$ before incision and $2.4{\pm}0.3sec$ at 2 hours and $5.9{\pm}0.6sec$ at 7 days after incision. The pain score increased from $1.1{\pm}0.8$ to $7.4{\pm}1.5$ at 2 days after incision. Conclusions: A mouse model of acute postoperative pain was developing by making a surgical incision in the mouse hindpaw. Mechanical hyperalgesia and allodynia lasting for several days demonstrate that this model has similarities to the human post-operative pain state. Future studies will allow us to further investigate the genetic and molecular mechanisms of incisional pain.

경결막 접근법과 비강을 통한 정복술을 이용한 안와골절의 수술 (Transnasal Reduction of Blow Out Fracture with Transconjunctival Approach)

  • 이원;강동희;오상아;이성환
    • 대한두개안면성형외과학회지
    • /
    • 제11권1호
    • /
    • pp.1-6
    • /
    • 2010
  • Purpose: Many surgical approaches for reconstruction of blow out fracture have been introduced, which include subciliary incision, transconjunctival incision and transcaruncular incision. Recently endoscopic approach has been attempted. This study was intended to show the effectiveness of the approach through transconjunctival incision combined with transnasal reduction in reconstructing blow out fracture to its original position. Methods: Medical recoreds of 43 patients from March 2008 to March 2009 who underwent surgery for orbital fracture were reviewed, retrospectively. All fractures were operated through transconjuctival incision approach combined with transnasal reduction. The average follow-up period was 10.1 months. To evaluate the surgical outcomes of orbital fracture, we performed CT of the facial bone before and after the surgery. In addition, preoperative and postoperative data of enophthalmos, diplopia and the limitation of extraocular motion was assessed with physical examination. Results: Post-operative CT scan of 43 patients assured that the bone fragments of the orbital fractures were restored to their original positions. Although a few patients developed postoperative transient diplopia or impairment of ocular movement, most of the patients recovered during the follow-up period without complication. Conclusion: From this study, we were able to demonstrate the effectiveness of the transnsasal reduction technique combined with the approach through transconjunctival incision. This technique can be considered as very useful means of repairing orbital fracture. It is not only easy to perform but also it can minimize the damage to the orbital bone. Furthermore, it can restore the fracture to its original position as much as possible.

경중도 안와 내벽 골절의 수술 시 흉터 최소화를 위한 변형된 직접 W-절개법과 실리콘판을 이용한 재건 (Modified Direct W-incision with Silicone Sheet to Minimize Operation Scar in Reconstruction of Mild to Moderate Symptomatic Medial Orbital Wall Fracture)

  • 정재아;공정식;김양우;강소라
    • 대한두개안면성형외과학회지
    • /
    • 제14권1호
    • /
    • pp.30-35
    • /
    • 2013
  • Background: For reconstruction of the mild to moderate medial orbital wall fractures, various surgical approaches have been used. Prior existing W-shaped incision was a direct local approach through a 3 cm incision on the superior medial orbital area with a titanium mesh implant. In this study, the authors modified W-shaped incision and reconstructed the defect with silastic sheet to improve the result and the postoperative scar. Methods: This study included 20 patients who had mild to moderate size of medial wall defect and therefore relatively suitable for reconstruction with silastic sheets from July, 2009 to December, 2011. A modified W-shaped skin incision approximately 1.2 to 1.5 cm in length was made along the superior medial orbital rim from approximately 1 cm medial to the medial canthus to the lower border of the medial eyebrow. The angles of the limbs of the W ranged from 150 to 160 degrees. Results: By using soft flexible silastic sheet, the authors reduced the incision from 3 to 1.5 cm, and by widening the angle of the W limbs, scars were more effectively hided in the relaxed skin tension line. Scar assessment was done with modified patient and observer scar assessment scale and mean score from patients was 2.08 and mean score from observers was 2.12. Conclusion: Although this method will not be suitable for every case, it can be a consistent method to obtain the surgical goal in treatment of mild to moderate blowout fractures of the medial orbital wall.

New Technique of Intracorporeal Anastomosis and Transvaginal Specimen Extraction for Laparoscopic Sigmoid Colectomy

  • Wang, Zheng;Zhang, Xing-Mao;Zhou, Hai-Tao;Liang, Jian-Wei;Zhou, Zhi-Xiang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권16호
    • /
    • pp.6733-6736
    • /
    • 2014
  • Background: Despite the growing acceptance of laparoscopic colon surgery, an abdominal incision is needed to remove the specimen and perform an anastomosis. Recently, natural orifice specimen extraction (NOSE) and intracorporeal anastomosis have been proposed to minimize abdominal wall trauma and improve the quality of laparoscopic colon resections Objective: To evaluate the feasibility and safety of a new approach combining intracorporeal delta-shaped anastomosis and transvaginal specimen extraction for totally laparoscopic sigmoid colectomy. Materials and Methods: Mobilization of bowel and dissection of lymph nodes were performed laparoscopically. After both proximal and distal incisal edges about 10.0 cm distance from sigmoid neoplasm were transected with an Endoscopic Linear Cutter-Straight, a small incision about 1.0 cm was created on the each colon wall of the contralateral side of the mesentery. Then anvils of an Endoscopic Linear Cutter-Straight were inserted into each colon through the small incisions, and incision and anastomosis between the walls of each colon were performed with a linear stapler. A V-shaped anastomosis was made on the wall and the remnant openings was reclosed with the Endoscopic Linear Cutter-Straight. The culdotomy was enlarged with laparoscopic ultrasound dissector. Transvaginal extraction of specimens was accomplished through a wound protector. Results: Surgery was performed for 11 patients with sigmoid cancer. No intraoperative complications or conversions occurred. The mean operating time was 132 min. All the patients were treated laparoscopically without any postoperative complications. Conclusions: The procedures of intracorporeal delta-shaped anastomosis and transvaginal specimen extraction are safe and oncologically acceptable for selected colon cancer cases.