• Title/Summary/Keyword: surgeon

Search Result 974, Processing Time 0.027 seconds

Generation and Detection of Cranial Landmark

  • Heo, Suwoong;Kang, Jiwoo;Kim, Yong Oock;Lee, Sanghoon
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.26-32
    • /
    • 2015
  • Purpose When a surgeon examines the morphology of skull of patient, locations of craniometric landmarks of 3D computed tomography(CT) volume are one of the most important information for surgical purpose. The locations of craniometric landmarks can be found manually by surgeon from the 3D rendered volume or 2D sagittal, axial, and coronal slices which are taken by CT. Since there are many landmarks on the skull, finding these manually is time-consuming, exhaustive, and occasionally inexact. These inefficiencies raise a demand for a automatic localization technique for craniometric landmark points. So in this paper, we propose a novel method through which we can automatically find these landmark points, which are useful for surgical purpose. Materials and Methods At first, we align the experimental data (CT volumes) using Frankfurt Horizontal Plane (FHP) and Mid Sagittal Plane(MSP) which are defined by 3 and 2 cranial landmark points each. The target landmark of our experiment is the anterior nasal spine. Prior to constructing a statistical cubic model which would be used for detecting the location of the landmark from a given CT volume, reference points for the anterior nasal spine were manually chosen by a surgeon from several CT volume sets. The statistical cubic model is constructed by calculating weighted intensity means of these CT sets around the reference points. By finding the location where similarity function (squared difference function) has the minimal value with this model, the location of the landmark can be found from any given CT volume. Results In this paper, we used 5 CT volumes to construct the statistical cubic model. The 20 CT volumes including the volumes, which were used to construct the model, were used for testing. The range of age of subjects is up to 2 years (24 months) old. The found points of each data are almost close to the reference point which were manually chosen by surgeon. Also it has been seen that the similarity function always has the global minimum at the detection point. Conclusion Through the experiment, we have seen the proposed method shows the outstanding performance in searching the landmark point. This algorithm would make surgeons efficiently work with morphological informations of skull. We also expect the potential of our algorithm for searching the anatomic landmarks not only cranial landmarks.

Clinical Outcomes of Reduced-Port Laparoscopic Surgery for Patients With Sigmoid Colon Cancer: Surgery With 1 Surgeon and 1 Camera Operator

  • Oh, Jung Ryul;Park, Sung Chan;Park, Sung Sil;Sohn, Beonghoon;Oh, Hyoung Min;Kim, Bun;Kim, Min Jung;Hong, Chang Won;Han, Kyung Su;Sohn, Dae Kyung;Oh, Jae Hwan
    • Annals of Coloproctology
    • /
    • v.34 no.6
    • /
    • pp.292-298
    • /
    • 2018
  • Purpose: This study compared the perioperative clinical outcomes of reduced-port laparoscopic surgery (RPLS) with those of conventional multiport laparoscopic surgery (MPLS) for patients with sigmoid colon cancer and investigated the safety and feasibility of RPLS performed by 1 surgeon and 1 camera operator. Methods: From the beginning of 2010 until the end of 2014, 605 patients underwent a colectomy for sigmoid colon cancer. We compared the characteristics, postoperative outcomes, and pathologic results for the patients who underwent RPLS and for the patients who underwent MPLS. We also compared the clinical outcomes of single-incision laparoscopic surgery (SILS) and 3-port laparoscopic surgery. Results: Of the 115 patients in the RPLS group, 59 underwent SILS and 56 underwent 3-port laparoscopic surgery. The MPLS group included 490 patients. The RPLS group had shorter operating time ($137.4{\pm}43.2minutes$ vs. $155.5{\pm}47.9minutes$, P < 0.001) and shorter incision length ($5.3{\pm}2.2cm$ vs. $7.8{\pm}1.2cm$, P < 0.001) than the MPLS group. In analyses of SILS and 3-port laparoscopic surgery, the SILS group showed younger age, longer operating time, and shorter incision length than the 3-port surgery group and exhibited a more advanced T stage, more lymphatic invasion, and larger tumor size. Conclusion: RPLS performed by 1 surgeon and 1 camera operator appears to be a feasible and safe surgical option for the treatment of patients with sigmoid colon cancer, showing comparable clinical outcomes with shorter operation time and shorter incision length than MPLS. SILS can be applied to patients with favorable tumor characteristics.

Comparison of Single-Incision Robotic Cholecystectomy, Single-Incision Laparoscopic Cholecystectomy and 3-Port Laparoscopic Cholecystectomy - Postoperative Pain, Cosmetic Outcome and Surgeon's Workload

  • Kim, Hyeong Seok;Han, Youngmin;Kang, Jae Seung;Lee, Doo-ho;Kim, Jae Ri;Kwon, Wooil;Kim, Sun-Whe;Jang, Jin-Young
    • Journal of Minimally Invasive Surgery
    • /
    • v.21 no.4
    • /
    • pp.168-176
    • /
    • 2018
  • Purpose: Robotic-associated minimally invasive surgery is a novel method for overcoming some limitations of laparoscopic surgery. This study aimed to evaluate the outcomes (postoperative pain, cosmesis, surgeon's workload) of single-incision robotic cholecystectomy (SIRC) vs. single-incision laparoscopic cholecystectomy (SILC) vs. conventional three-port laparoscopic cholecystectomy (3PLC). Methods: 134 patients who underwent laparoscopic or robotic cholecystectomy at a single center during 2016~2017 were enrolled. Prospectively collected data included demographics, operative outcomes, questionnaire regarding pain and cosmesis, and NASA-Task Load Index (NASA-TLX) scores for surgeon's workload. Results: 55 patients underwent SIRC, 29 SILC, and 50 3PLC during the same period. 3PLC patient group was older than the others (SIRC vs. SILC vs. 3PLC: 48.1 vs. 42.2 vs. 54.1 years, p<0.001). Operative time was shortest with 3PLC (44.1 vs. 38.8 vs. 25.4 min, p<0.001). Estimated blood loss, postoperative complications, and postoperative stay were similar among the groups. Pain control was lowest in the 3PLC group (98.2% vs. 100% vs. 84.0%, p=0.004), however, at 2 weeks postoperatively there were no differences among the groups (p=0.374). Cosmesis scores were also worst after 3PLC (17.5 vs. 18.4 vs. 13.3, p<0.001). NASA-TLX score was highest in the SILC group (21.9 vs. 44.3 vs. 25.2, p<0.001). Conclusion: Although SIRC and SILC take longer than 3PLC, they produce superior cosmetic outcomes. Compared with SILC, SIRC is more ergonomic, lowering the surgeon's workload. Despite of higher cost, SIRC could be an alternative for treating gallbladder disease in selected patients.

Angioembolization performed by trauma surgeons for trauma patients: is it feasible in Korea? A retrospective study

  • Soonseong Kwon;Kyounghwan Kim;Soon Tak Jeong;Joongsuck Kim;Kwanghee Yeo;Ohsang Kwon;Sung Jin Park;Jihun Gwak;Wu Seong Kang
    • Journal of Trauma and Injury
    • /
    • v.37 no.1
    • /
    • pp.28-36
    • /
    • 2024
  • Purpose: Recent advancements in interventional radiology have made angioembolization an invaluable modality in trauma care. Angioembolization is typically performed by interventional radiologists. In this study, we aimed to investigate the safety and efficacy of emergency angioembolization performed by trauma surgeons. Methods: We identified trauma patients who underwent emergency angiography due to significant trauma-related hemorrhage between January 2020 and June 2023 at Jeju Regional Trauma Center. Until May 2022, two dedicated interventional radiologists performed emergency angiography at our center. However, since June 2022, a trauma surgeon with a background and experience in vascular surgery has performed emergency angiography for trauma-related bleeding. The indications for trauma surgeon-performed angiography included significant hemorrhage from liver injury, pelvic injury, splenic injury, or kidney injury. We assessed the angiography results according to the operator of the initial angiographic procedure. The term "failure of the first angioembolization" was defined as rebleeding from any cause, encompassing patients who underwent either re-embolization due to rebleeding or surgery due to rebleeding. Results: No significant differences were found between the interventional radiologists and the trauma surgeon in terms of re-embolization due to rebleeding, surgery due to rebleeding, or the overall failure rate of the first angioembolization. Mortality and morbidity rates were also similar between the two groups. In a multivariable logistic regression analysis evaluating failure after the first angioembolization, pelvic embolization emerged as the sole significant risk factor (adjusted odds ratio, 3.29; 95% confidence interval, 1.05-10.33; P=0.041). Trauma surgeon-performed angioembolization was not deemed a significant risk factor in the multivariable logistic regression model. Conclusions: Trauma surgeons, when equipped with the necessary endovascular skills and experience, can safely perform angioembolization. To further improve quality control, an enhanced training curriculum for trauma surgeons is warranted.

Deviated nose: Physiological and pathological changes of the nasal cavity

  • Kim, Taek Kyun;Jeong, Jae Yong
    • Archives of Plastic Surgery
    • /
    • v.47 no.6
    • /
    • pp.505-515
    • /
    • 2020
  • Deviated nose is highly challenging in rhinoplasty since the surgeon should consider both aesthetic and functional aspects of the nose. Deviated nose correction is surgically complex, and a thorough understanding of the mechanical and physiological changes of intranasal structures, including the septum and turbinates, is necessary for functional improvement.

Preparation of harvested skin using the Versajet Hydrosurgery System in full-thickness skin grafts

  • Choi, Seo Gil;Shin, Hyun Woo;Yoon, Kun Chul
    • Archives of Plastic Surgery
    • /
    • v.46 no.6
    • /
    • pp.603-607
    • /
    • 2019
  • During a full-thickness skin graft procedure, the thickness of the harvested donor skin is adjusted based on the location of the recipient site and the judgment of the surgeon. Conventionally, the thickness of the harvested skin is roughly adjusted using surgical instruments such as scalpels and scissors. However, this method is not only time-consuming, but also requires effort to obtain both the desired thickness of the harvested skin and a smooth surface of that skin. Moreover, there is a possibility of skin perforation. Hence, the authors devised a method of adjusting harvested skin thickness using the Versajet Hydrosurgery System. The Versajet device is a handheld hydrosurgical tool that delivers a high-speed jet stream of saline solution, which enables the precise debridement of tissue. This method makes it easier and faster for the surgeon to obtain the desired thickness of harvested skin. In addition, by obtaining a smooth surface and an even thickness of harvested donor skin, this technique may lead to improved graft viability.

Complications of impacted third molar extraction: retrospective study (매복지치 발치 시 발생한 합병증 양상에 대한 후향적 연구)

  • Hwang, Jung-Kook;Kim, Kyung-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.2
    • /
    • pp.119-124
    • /
    • 2010
  • Introduction: Surgical extraction of third molar is one of the most frequently performed procedures in oral and maxillofacial surgery unit as the impacted wisdom teeth could cause various complications. Even though, however, extraction of the impacted wisdom teeth is an obligation for the reason of possible complication even for general practitioners, it has been avoided. Various factors concerning surgical extraction of impacted third molar are considered: general condition of patients, relationship with relative anatomies, aspects of impaction, surgeon's skill. Materials and Methods: The consideration and crossing analysis of these factors with 2,463 patients who visit Dankook University dental hospital to extract those impacted third molar. Results: 1. Gender doesn't affect. 2. Medical problems have more complications. 3. There are more complications in high difficulty index (DI) impacted teeth. 4. When inferior alveolar canal overlap mandibular third molar, complication rate is 26.92%. 5. The most common complication was swelling and pain. 6. There is no statistical difference between the incidence of complication and surgeon's experience. Conclusion: In regard to these results, it seems that clinical or radiological examination can predict potential complications of wisdom teeth, and it is helpful to bear in mind the fact.

Simultaneous Paraspinal and Midline Approach for Upper Lumbar Disc Herniation : Technique to Prevent Lamina Fracture

  • Kim, Seok-Won;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.2
    • /
    • pp.111-115
    • /
    • 2005
  • Objective : Upper lumbar disc herniation is rare disease, compared with lower. The lamina of this high level lumbar vertebra is narrower than that of low level, and this have taken surgeon into important consideration for surgical methods because partial removal of lamina for discectomy weakens the base of the articular process and may result in fracture. The authors an accurate preoperative diagnosis that enables the surgeon to operative approach for preserving the facet joint. Methods : Thirteen patients with upper lumbar disc herniation have underone surgical procedure by midline approach for removal of ruptured disc fragment and paraspinal approach for removal of residual disc materials simultaneously without instrumentation. All patients who underwent surgery were analyzed and long-term follow-up was conducted. Results : At a mean follow-up of 24months, there were complete resolution of presenting radiating leg pain in 85% of the patients, 7.5% were left with minimal residual discomfort, and 7.5% derived little or no benefit from surgery. The follow-up radiologic findings of all patients shows that lamina and facet joint have preserved safely and no instability. Conclusion : Simultaneously, paraspinal with midline approach provides highly satisfactory operating methods by simplifying exposure and greatly limiting the risk of complications. This provides the basis for a planned surgical approach in which destruction of the facet joint can be avoided.