• 제목/요약/키워드: surge condition

검색결과 166건 처리시간 0.027초

조위변동을 고려한 폭풍해일시의 해안침식에 관한 연구 (Beach Erosion during Storm Surge Overlapped with Tide)

  • 손창배
    • 해양환경안전학회지
    • /
    • 제6권2호
    • /
    • pp.47-56
    • /
    • 2000
  • This paper describes a simple prediction method of beach recession induced by storm surge. In order to evaluate the severest beach erosion, it is assumed that maximum beach recession occurs at the coming of storm surge overlapped with spring tide. Consequently, total surge lev디 becomes the sum of storm surge level and tidal range. Generally, storm surge level around Korea is small compared with tidal range. Therefore total surge can be expressed as the series of surges, which have same duration as tide. Through the case studies, the author Investigates correlation between tidal range, duration, wave condition, beach slope and beach recession.

  • PDF

차량 드로틀 보디 전장부품의 품질관리 성능시험 알고리즘 개발 (Development of Algorithm of Surge Test for Quality Control on Electrical Parts of Throttle Body in Automobiles)

  • 손재환;김태한
    • 한국산업융합학회 논문집
    • /
    • 제9권1호
    • /
    • pp.67-72
    • /
    • 2006
  • This study is on the development of algorithm of surge test for quality control on electrical parts of throttle body in automobiles with internal combustion engine, not only to know its condition to be good or not, but also jugding its condition to be classified into six types. To know whether its condition to be good or not, comparing and analyzing between two waveforms generated from master and test coil of throttle body. If test net area is below 20% of master area, the condition of test coil is good. By analyzing test coil waveform to master coil waveform, the condition of test coil into winding badness, insulation badness, layer and corona discharge, short badness should known. Therefore quality control system on electrical parts of throttle body should be developed.

  • PDF

국내 배전계통의 가공지선 접지조건에 따른 뇌서지 영향 분석 (Analysis of Effect on Lightning Surge according to the Grounding Condition of Overhead Ground Wire in Distribution System)

  • 한준;김철환;서훈철;최선규;이병성
    • 전기학회논문지
    • /
    • 제63권3호
    • /
    • pp.331-337
    • /
    • 2014
  • The Korean distribution system consists of overhead ground wire (OHGW), phase conductors and neutral wire. Especially, OHGW is installed over the phase conductors to protect distribution system from the lightning surge. The flashover rate and the magnitude of lightning overvoltage on distribution system can be affected by grounding condition of OHGW such as grounding resistance and grounding interval. In this paper, we conduct an analysis of lightning overvoltage and flashover rate according to the grounding condition of OHGW. The distribution system and lightning surge are modeled by using ElectroMagnetic Transient Program (EMTP). Also, the Monte Carlo method is applied to consider random characteristics of lightning, and the flashover rate is calculated based on IEEE std. 1410. The simulations are performed by changing the grounding resistance and interval of OHGW and the simulation results are analyzed.

과도서지에 의한 견인전동기 고정자 코일의 상태진단 연구 (A Study on the Condition Diagnosis for the Stator Coil of Traction Motor by Transient Surge)

  • 박현준;장동욱;김길동;최종선;김정수
    • 전력전자학회논문지
    • /
    • 제8권3호
    • /
    • pp.247-252
    • /
    • 2003
  • 전동기 절연열화와 파괴는 전동기에 가해지는 스트레스에 영향을 받는다. 즉 절연물의 수명은 주어지는 스트레스의 심한 정도에 따라서 좌우된다. 전동차용 견인전동기에서도 과도서지에 의한 전기적인 열화를 검토하는 것은 매우 중요한 요소이다. 본 논문에서는 인버터에서 발생되는 과도서지에 의한 고정자 코일의 절연특성을 고찰해 보았다. 전동기의 절연상태, 열화진전도, 열화발생 범위 등을 측정하는 유용한 비파괴시험 방법에는 여러 가지가 이용되고 있다. 누설전류, 유전손실(tan$\delta$), 정전용량, 성극지수(PI), 부분방전 등의 방법들을 통하여 고정자 코일의 절연상태를 분석하였다. 이러한 진단 방법들은 전동차의 견인전동기에 대한 열화상태와 수명예측에 유용한 방법이 될 것으로 여겨진다.

댐 안전관리를 위한 조압수조의 규모 결정 (Determination of Surge Tank Scale for Dam Safety Management)

  • 이호진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권2호
    • /
    • pp.164-174
    • /
    • 2007
  • 댐에서 관로 시스템을 효과적으로 설계하기 위해서는 수격작용과 같은 과도수리현상을 해석해야 만 한다. 일반적으로 조압수조는 터빈의 부하변화에 의한 과도수리현상에 의해 발생되는 압력의 변화를 감소시키기 위해서 사용된다. 본 연구에서는 댐 안전관리를 위한 조압수조의 적정규모를 조사하였다. 지배방정식을 이용하여 조압수조 내 수위변동을 계산하였다. Thoma-Jaeger의 안정조건을 사용하여 홍수위, 상시만수위, 정격수위, 저수위인 경우에 정적안정조건과 동적안정조건을 검토하였다. 끝으로 조압수조의 수직갱과 수실의 적정 지름을 결정하였다.

Analytical Surge Behaviors in Systems of a Single-stage Axial Flow Compressor and Flow-paths

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권1호
    • /
    • pp.1-16
    • /
    • 2016
  • Behaviors of surges appearing near the stall stagnation boundaries in various fashions in systems of a single-stage compressor and flow-path systems were studied analytically and were tried to put to order. Deep surges, which enclose the stall point in the pressure-mass flow plane, tend to have either near-resonant surge frequencies or subharmonic ones. The subharmonic surge is a multiple-loop one containing, for example, in a (1/2) subharmonic one, a deep surge loop and a mild surge loop, the latter of which does not enclose the stall point, staying only within the stalled zone. Both loops have nearly equal time periods, respectively, resulting in a (1/2) subharmonic surge frequency as a whole. The subharmonic surges are found to appear in a narrow zone neighboring the stall stagnation boundary. In other words, they tend to appear in the final stage of the stall stagnation process. It should be emphasized further that the stall stagnation initiates fundamentally at the situation where a volume-modified reduced resonant-surge frequency becomes coincident with that for the stagnation boundary conditions, where the reduced frequency is defined by the acoustical resonance frequency in the flow-path system, the delivery flow-path length and the compressor tip speed, modified by the sectional area ratio and the effect of the stalling pressure ratio. The real surge frequency turns from the resonant frequency to either near-resonant one or subharmonic one, and finally to stagnation condition, for the large-amplitude conditions, caused by the non-linear self-excitation mechanism of the surge.

펌프 기동 및 정지에 따른 배관 압력상승과 수격작용 영향 고찰 (Consideration of Pressure-Rise and Water Hammer for Pipe System in Relation to Start-Up and Sudden Stop of the Pump)

  • 허민웅;민지호
    • 한국압력기기공학회 논문집
    • /
    • 제13권1호
    • /
    • pp.69-74
    • /
    • 2017
  • In the fire protection system or fire fighting water supply system, the jockey pump is generally installed for the prevention of the pressure decrease of pipes, the frequent driving of the fire pump and protection the pipes from the water hammer. In this paper, the pressure-rise in fire fighting water distribution pipes in condition of pipe pressurization by the surge tank at the start-up and the sudden-stop of the fire pump without additional installation of jockey pump is considered by using simple formula calculations and the evaluation of water hammer occurrence in condition of pipe pressurization by the surge tank is included. As a result, the pressure-rise of pipes is less than the pipe design pressure at the condition of pump's start-up and sudden stop, and the possibility of water hammer occurrence is remarkably low due to pressurization of the pipes by the surge tank.

서지보호기의 상태 감시를 위한 MOV의 고장률 예측 (Failure Rate Estimation of MOV for Condition Monitoring of Surge Protective Devices)

  • 김동진;김영선;박재준;이기식
    • 전기학회논문지
    • /
    • 제62권9호
    • /
    • pp.1302-1307
    • /
    • 2013
  • MOV(Metal Oxide Varistor) is the most important part of SPD(Surge Protective Device) which can protect electric facilities from an impulse current such as a lightning. So far, the fault of MOVs have decided only by surge count without considering magnitude of surge current and an amount of input energy. This paper proposed the fault prediction algorithm for the MOV using look up table made by surge count and input current data which have non-linear characteristics for input current and are estimated by high voltage experimental results. Proposed algorithm was proved by experiment on verification at a high voltage laboratory.

Analysis of the fluid-solid-thermal coupling of a pressurizer surge line under ocean conditions

  • Yu, Hang;Zhao, Xinwen;Fu, Shengwei;Zhu, Kang
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3732-3744
    • /
    • 2022
  • To investigate the effects of ocean conditions on the thermal stress and deformation caused by thermal stratification of a pressurizer surge line in a floating nuclear power plant (FNPP), the finite element simulation platform ANSYS Workbench is utilized to conduct the fluid-solid-thermal coupling transient analysis of the surge line under normal "wave-out" condition (no motion) and under ocean conditions (rolling and pitching), generating the transient response characteristics of temperature distribution, thermal stress and thermal deformation inside the surge line. By comparing the calculated results for the three motion conditions, it is found that ocean conditions can significantly improve the thermal stratification phenomenon within the surge line, but may also result in periodic oscillations in the temperature, thermal stress, and thermal deformation of the surge line. Parts of the surge line that are more susceptible to thermal fatigue damage or failure are determined. According to calculation results, the improvements are recommended for pipeline structure to reduce the effects of thermal oscillation caused by ocean conditions. The analysis method used in this study is beneficial for designing and optimizing the pipeline structure of a floating nuclear power plant, as well as for increasing its safety.

커플링/디커플링 네트워크 내장 서지발생장치의 설계 및 제작 (Design and Fabrication of a Surge Generator with Coupling/Decoupling Networks)

  • 김남훈;강태호;신한신;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제33권2호
    • /
    • pp.130-134
    • /
    • 2020
  • Metal oxide varistors (MOVs) protect circuits and devices from transient overvoltages in electric power systems. However, a MOV continuously deteriorates owing to manufacturing defects or repetitive protective operations from transient overvoltages. A deteriorated MOV may result in a short circuit or a line-ground accident. Previous studies focused on the analysis of deterioration mechanisms and condition diagnosis techniques for MOVs owing to their recent growth of use. An accelerated deterioration experiment under the same conditions in which a MOV operates is essential. In this study, we designed and fabricated a surge generator that can apply a surge current to a MOV connected to AC mains. The coupling network operates at a low impedance against the surge current from the surge generator and transfers the surge current to the MOV under test. It also acts as a high impedance against AC mains for the AC voltage not to be applied to the surge generator. The decoupling network operates at a high impedance against the surge current and blocks the surge current from AC mains. It also acts as a low impedance against AC mains for the AC voltage to be applied to the MOV under test. The prototype surge generator can apply the 8/20 us up to 15 kA on AC voltages in the approximate range of 110~450 V, and it fully operates on a LabVIEW-based program.