• 제목/요약/키워드: surface treatment system

검색결과 1,233건 처리시간 0.029초

폭기식 잠수여상을 이용한 고밀도 양식장의 순환수 처리 -1. 해수중의 암모니아 제거 특성- (The Recycling Water Treatment of High Density Fish Culture System Using the Aerated Submerged Filter -1. Ammonia Removal Characteristics in Sea Water-)

  • 이헌모;이재관;정병곤;양병수
    • 한국수산과학회지
    • /
    • 제26권5호
    • /
    • pp.502-509
    • /
    • 1993
  • Submerged filter process was used to evaluate the nitrifying efficiency of ammonia in the recycling water of marine aquatic culture system. The ammonia removal efficiency was achieved as high as $99\%$ at the hydraulic surface loading rate of up to $4.3{\ell}/m^2-day$. And the nitrite accumulation did not occur in the reactor even when the hydraulic surface loading rate of up to $36.8{\ell}/m^2day$ was applied. In the present study, the relationship between the effluent ammonia concentration and ammonia surface loading rate was formulated as an equation. The attachment rate of biofilm on the filter media at the ammonia surface loading rate of 62.3 and $311.7mg/m^2day$ was 15 and $55mg/m^2-day$, respectively, showing the linear relationship between the attachment rate and ammonia loading rates. Biofilm thickness and density of the filter media were found to be the function of the ammonia loading rate.

  • PDF

고초균 포자를 이용한 Zymomonas mobilis 유래의 levansucrase 표면 발현 (Bacterial Surface Display of Levansucrase of Zymomonas mobilis Using Bacillus Subtilis Spore Display System)

  • 김준형;최수근;정흥채;반재구;김병기
    • KSBB Journal
    • /
    • 제26권3호
    • /
    • pp.243-247
    • /
    • 2011
  • Using Bacillus subtilis spore display system, with cotG as an anchoring motif, levansucrase from Zymomonas mobilis, was displayed on the outer surface of Bacillus subtilis spore. Flow cytometry of DB104 (pSDJH-cotG-levU) spore, proved the surface localization of CotG-LevU fusion protein on the spore compared to that of DB104. Enzymatic activity of DB104 (pSDJH-cotG-levU) spore showed more than 1.5 times higher levansucrase specific activity compared to that of the host spore, which is a remarkable increase of enzymatic activity considering the existence of sacA (sucrase) and sacB (levansucrase) in the Bacillus subtilis chromosome. The spore integrity, revealed by sporulation frequency test after heat and lysozyme treatment of spore, did not changed at all in spite of the CotG-LevU fusion protein incorporation into the spore coat layer during spore formation process. These data prove again that Bacillus subtilis spore could be considered as good live immobilization vehicle for efficient bioconversion process.

SDB와 etch-back 기술에 의한 MEMS용 SiCOI 구조 제조 (Fabrication of SiCOI Structures Using SDB and Etch-back Technology for MEMS Applications)

  • 정수용;우형순;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.830-833
    • /
    • 2003
  • This paper describes the fabrication and characteristics of 3C-SiCOI sotctures by SDB and etch-back technology for high-temperature MEMS applications. In this work, insulator layers were formed on a heteroepitaxial 3C-SiC film grown on a Si(001) wafer by thermal wet oxidation and PECVD process, successively. The pre-bonding of two polished PECVD oxide layers made the surface activation in HF and bonded under applied pressure. The wafer bonding characteristics were evaluated by the effect of HF concentration used in the surface treatment on the roughness of the oxide and pre-bonding strength. Hydrophilic character of the oxidized 3C-SiC film surface was investigated by ATR-FTIR. The strength of the bond was measured by tensile strengthmeter. The bonded interface was also analyzed by SEM. The properties of fabricated 3C-SiCOI structures using etch-back technology in TMAH solution were analyzed by XRD and SEM. These results indicate that the 3C-SiCOI structure will offers significant advantages in the high-temperature MEMS applications.

  • PDF

Soroban grid 기반 CIP법을 이용한 자유표면 유동해석 (FREE SURFACE FLOW ANALYSIS BY SOROBAN GRID BASED CIP MEHTOD)

  • 임효남
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.326-334
    • /
    • 2010
  • In this study, we provide a comprehensive review of the CIP(Constrained Interpolation Pro file/Cubic Interpolated Propagation) method with a pressure-based algorithm that is known as a general numerical solver for soled liquid, gas and plasmas. And also we introduce a body-fitted grid system(Soroban grid) for computation of strongly nonlinear marine hydrodynamic problems such as slamming water on deck, wave impact by green water. This grid system can keep the third-order accuracy in time and space with the help of the CIP method. The grid system consists of the straight lines and grid points. In the 2-dimensional grid case, each grid points moving in these lines like abacus - Soroban in Japanese. The length of each line can be different and the number of grid points in each line can be different. Mesh generation and searching of upstream departure point are very simple and possible to mesh-free treatment. To optimize computation of free-surface and multi-fluid flows, We adopt the C-CUP method. In most of the earlier computations, the C-CUP method was used with a staggered-grid approach. Here, because of the mesh free nature of the Soroban grid, we use the C-CUP method with a collocated-grid approach.

  • PDF

치료 장비 별 표면 선량 비교평가 (Evaluation of surface dose comparison by treatment equipment)

  • 최은하;윤보름;박병석;안예찬;박명환;박용철
    • 대한방사선치료학회지
    • /
    • 제34권
    • /
    • pp.31-42
    • /
    • 2022
  • 목 적: 본 연구는 6MV-FFF(Flattening Filter Free) 에너지를 사용하는 Tomotherapy, Halcyon, True-Beam 장비를 이용하여 가상의 표적 용적에 대한 표면 선량 값을 측정, 비교평가하고자 한다. 대상 및 방법: IMRT 팬텀(IBA, Germany)을 이용하였으며 표면 선량 측정의 정확도를 높이기 위해 without bolus, 0.5 cm bolus, 1 cm bolus 총 세 가지 조건으로 전산화 단층촬영을 시행하였다. 가상의 표적 깊이에 치료 계획 용적(Planning Target Volume, PTV)을 설정하고 1회, 200 cGy로 치료 계획을 각각 수립하였다. 표면 선량 측정은 Gafchromic EBT3 필름을 전산화 치료 계획과 동일한 구간에 위치시켜 10회 반복 측정한 뒤 분석하였다. 결 과: 각 장비 별 실험 결과 without bolus, 0.5 cm bolus, 1 cm bolus 순서로 표면 선량 측정값의 평균은 Tomotherapy에서 115.2±2.0 cGy, 194.4±3.3 cGy, 200.7±2.9 cGy로 확인되었고, Halcyon에서 104.7±3.0 cGy, 180.1±10.8 cGy, 187.0±10.1 cGy로 확인되었으며, TrueBeam에서 92.4±3.2 cGy, 148.6±5.7 cGy, 155.8±6.1 cGy로 확인되었다. 세 가지 조건에서 모두 치료 계획 시스템과 동일하게 Tomotherapy, Halcyon, TrueBeam 순으로 높게 측정되었다. 결 론: Tomotherapy와 Halcyon에서 TrueBeam 장비에 비해 표면 선량이 높게 측정되었다. 치료 부위와 치료 목적에 맞춰 장비 별 특성이 고려된다면 치료 효율성의 증가뿐 아니라 환자의 치료 만족도도 높아질 것으로 사료된다.

TiN 및 DLC 코팅된 척추경나사못시스템 수술기구의 기계적 안정성 분석 (Mechanical Stability of TiN and DLC Coated Instrument of Pedicle Screw System)

  • 강관수;정태곤;양재웅;우수헌;박태현;정용훈
    • 한국표면공학회지
    • /
    • 제52권3호
    • /
    • pp.163-170
    • /
    • 2019
  • Durability of instrument is one of the most important factor to ensure accurate treatment and decrease failure for the orthopedic surgical operation. Normally, a set-screw driver tip has been processed with hard coating for their higher durability and wear resistance. And several surface modification methods were obtained such as titanium nitride (TiN) coating, diamond like carbon coating, other nitriding, and etc. In this study, we have surface modified on set-screw driver tip with TiN and DLC, investigated whether the TiN and DLC coatings affect the mechanical properties and durability of the set-screw driver tip in the pedicle screw system. The surface morphologies were observed with scanning-electron microscopy (SEM), and the static/dynamic torsional properties were investigated with universal testing machine based on ASTM F543. Coating thickness of each coatings were commonly around $1^{\circ}C$. Static torsional stiffness, and ultimate torque values for DLC and TiN coated samples were significantly higher than those of non-coated sample by the pared T-test. Surface morphology of after the dynamic torsional test was more clean with less scratch or friction traces from DLC coating than that of TiN coating and non-coated sample.

The Effects of CF4 Partial Pressure on the Hydrophobic Thin Film Formation on Carbon Steel by Surface Treatment and Coating Method with Linear Microwave Ar/CH4/CF4 Plasma

  • Han, Moon-Ki;Cha, Ju-Hong;Lee, Ho-Jun;Chang, Cheol Jong;Jeon, Chang Yeop
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.2007-2013
    • /
    • 2017
  • In order to give hydrophobic surface properties on carbon steel, the fluorinated amorphous carbon films were prepared by using linear 2.45GHz microwave PECVD device. Two different process approaches have been tested. One is direct deposition of a-C:H:F films using admixture of $Ar/CH_4/CF_4$ working gases and the other is surface treatment using $CF_4$ plasma after deposition of a-C:H film with $Ar/CH_4$ binary gas system. $Ar/CF_4$ plasma treated surface with high $CF_4$ gas ratio shows best hydrophobicity and durability of hydrophobicity. Nanometer scale surface roughness seems one of the most important factors for hydrophobicity within our experimental conditions. The properties of a-C:H:F films and $CF_4$ plasma treated a-C:H films were investigated in terms of surface roughness, hardness, microstructure, chemical bonding, atomic bonding structure between carbon and fluorine, adhesion and water contact angle by using atomic force microscopy (AFM), nano-indentation, Raman analysis and X-ray photoelectron spectroscopy (XPS).

표면 처리에 따른 Inconel 617 합금의 고온 특성 (Thermal properties of the surface-modified Inconel 617)

  • 조현;방광현;이병우
    • 한국결정성장학회지
    • /
    • 제19권6호
    • /
    • pp.298-304
    • /
    • 2009
  • 고온 열수송시스템용 구조재료인 Inconel 617의 표면 처리에 따른 고온물성 개선에 대한 연구를 수행하였다. 표면처리 방법으로는 Inconel 617 기판 상에 급속가열(RTP) 및 수열처리를 통한 균질산화물 형성과 물리적 기상증착법(Arc discharge)법에 의한 TiAlN(두께 약 $2{\mu}m$ 박막 코팅을 적용하였다. 불균질 산화물($Cr_2O_3$) 형성 억제에 미치는 표면처리의 효과 및 표면 미세구조가 물성에 미치는 영향에 대해 알아보기 위해 표면처리된 Inconel 617 시편들을 $1000^{\circ}C$, 대기중에서 열처리 하였으며, 열처리된 시편들에 대해 고온 상형성 및 미세구조를 비교 분석하였다. RTP와 수열처리를 통한 표면산화물 형성보다는 TiAlN 박막 증착을 통한 보호피막의 형성이 Inconel 617 표면에서 생성되는 불균일 $Cr_2O_3$ 막의 성장을 효과적으로 억제할 수 있어서 더 균질한 미세구조와 가장 우수한 내마모 특성을 나타내었다.

Ti-6Al-4V 재의 UNSM 처리에 의한 피로특성변화 - 회전굽힘 피로시험과 축하중 인장압축 피로시험 비교 - (Variation of Fatigue Properties in Nanoskinned Ti-6Al-4V - Rotating Bending and Axial Loading Tension-Compression Cycle -)

  • 서민수;편영식;서창민
    • 대한기계학회논문집A
    • /
    • 제36권4호
    • /
    • pp.443-449
    • /
    • 2012
  • Ti-6Al-4V 재에 다양한 표면처리방법을 통하여 나노스킨화된 피로시험편을 제작하고 회전굽힘피로 시험과 축하중 인장압축피로시험을 수행하였다. 특히 S-N 곡선에서 초음파나노표면개질(UNSM)법은 국내특허기술로 다른 처리법들보다 우수한 결과를 보였고, UNSM 처리된 직경 5 mm 재는 6 mm 티타늄재를 대치 가능할 성능을 얻었다. UNSM 처리된 $10^6$ 사이클 이상의 장수명영역에서 피로강도가 크게 향상되는 시험결과를 얻었다. 균열발생 패턴의 분석을 통하여 Ti-6Al-4V 재는 응력의 작용형태에 따라 표면균열발생형(surface originating crack type)과 내부균열발생형(interior originating crack type)인 어안균열(fish eye crack)이 발생하는 메커니즘을 분석하였다.

초음파나노표면개질 기술을 적용한 초경의 기계적특성 및 마모 연구 (Improvement in Mechanical and Wear Properties of WC-Co by Ultrasonic Nanocrystal Surface Modification Technique)

  • 이승철;김준형;최갑수;장영도;아마노프아웨즈한;편영식
    • Tribology and Lubricants
    • /
    • 제31권2호
    • /
    • pp.56-61
    • /
    • 2015
  • In this study, we investigated the effectiveness of an ultrasonic nanocrystal surface modification (UNSM) technique on the mechanical and wear properties of tungsten carbide (WC). The UNSM technique is a newly developed surface modification technique that increases the mechanical properties of materials by severe plastic deformation. The objective of this study was to improve the wear resistance of press die made of WC by applying the UNSM technique. We observed the microstructures of the untreated and UNSM-treated specimens using a scanning electron microscope (SEM), and energy-dispersive X-ray spectroscopy (EDX) was used to investigate the chemical composition. The SEM observations showed the pore size and the number of pores decreased after the UNSM treatment. We assessed the wear behavior of both the untreated and UNSM-treated specimens using a scratch test. The test results showed that the wear resistance of the UNSM-treated specimens increased by about 46% compared with the untreated specimens. This may be attributed to increased hardness, reduced surface roughness, induced compressive residual stress, and refined grain size following the application of the UNSM technique. In addition, we found that the UNSM treatment increased the carbon concentration to 63% from 33%. We expect that implementing the findings of this study will lead to an increase in the life of press dies.