• Title/Summary/Keyword: surface spalling

Search Result 105, Processing Time 0.027 seconds

Analysis of Decontamination from Concrete by Microwave Power

  • 지광습
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.603-608
    • /
    • 2004
  • The paper analyzes a scheme of decontamination of radionuclides from concrete structures, in which rapid microwave heating is used to spall off a thin contaminated surface layer. The analysis is split in two parts: (1) The hygrothermal part of the problem, which consists in calculating the evolution of the temperature and pore pressure fields, and (2) the fracturing part, which consists in predicting the stresses, deformations and fracturing. The rate of the distributed source of heat due to microwaves in concrete is calculated on the basis of the standing wave normally incident to the concrete wall with averaging over both the time period and the wavelength because of the very short time period of microwaves compared to the period of temperature waves and the heterogeneity of concrete. The reinforcing bars parallel to the surface arc treated as a smeared steel layer. The microplane model M4 is used as the constitutive model for nonlinear deformation and distributed fracturing of concrete. The aim of this study is to determine the required microwave power and predict whether and when the contaminated surface layer of concrete spalls off. The effects of wall thickness, reinforcing bars, microwave frequencies and power are studied numerically. As a byproduct of this analysis, the mechanism of spalling of rapidly heated concrete is clarified.

  • PDF

알루미늄 확산코팅재료의 주기산화 특성에 관한 연구 (A Study on the Cyclic Oxidation Properties of Aluminum Diffusion Coated Materials)

  • 강석철;민경만;김길무
    • 한국표면공학회지
    • /
    • 제32권1호
    • /
    • pp.49-60
    • /
    • 1999
  • The protective oxide scales and coatings formed on high temperature materials must be preserved in high temperature atmosphere. And the thermal stresses induced by thermal cycling and the growth stresses by the formation of oxide scales can cause the loss of adherence and spalling of the oxide scales and coated layers. Among the coating processes Al diffusion coating is favored due to thermochemical stability and superior adherence in an hostile atmosphere. In this study, protective oxide forming element, Al was coated on Ni, Inconel 600 and 690 by diffusion coating process varying coating temperature and time. And the surface stability and adherence of oxide scales formed on those Al diffusion coated materials were evaluated by thermal cycling test. Al diffusion coated specimens showed superior cyclic oxidation resistance compared to bare ones and specimens coated for longer period had better cyclic oxidation resistance, due to the abundant amount of Al in the coated layer. Meanwhile Al diffusion coated Inconel 600 and 690 showed improved cyclic oxidation resistance by the effect of Al in the coated layer and Cr in the substrate. Comparing both Al diffusion coated Inconel 600 and 690, Al diffusion coated Inconel 690 maintained better adhesion between coated layer and substrate by virtue of the bridging effect resulting from the segregation of Cr in the interdiffusion zone.

  • PDF

ECC로 피복된 고강도콘크리트 부재의 폭렬억제성능에 관한 연구 (A Study on the Anti-Spalling Performance of High-Strength Concrete Members by covered Engineered Cementitious Composite)

  • 이재영;김재환;한병찬;박선규;권영진
    • 한국화재소방학회논문지
    • /
    • 제22권4호
    • /
    • pp.85-94
    • /
    • 2008
  • 본 연구는 HSC의 폭렬제어 및 내화성능 확보 방안 중 하나인, HSC에 내화성능을 갖는 피복층을 형성하는 방안에 대하여, 피복층을 ECC로 이용하는 경우 이에 대한 화재성상 및 내화특성을 실험적으로 검토하고, 수열온도 예측 등과 같은 내화설계를 위한 기초자료를 제시하기 위한 것이다. 이를 위하여 HSC 부재에 대한 내화시험을 실시하였다. 실험변수는 ECC의 피복층 두께(20, 30, 40 mm), 시공방식(라이닝, 보수)으로 하였으며, 비교 및 검증을 위하여 피복층이 없는 HSC 및 FRCC 2종류의 충전두께의 변화에 따른 실험을 실시하였다. 도입 화재하중은 ISO 834 기준 3시간 가열곡선으로 하였으며, 각 깊이별 수열온도, 폭렬 및 균열성상, 중성화깊이를 측정 평가하였다. 실험결과 ECC는 HSC 보다 높은 차열성능을 가지고 있으며, 폭렬저감성능을 확인 할 수 있었다. 또한 회귀분석을 통하여 ECC를 HSC의 피복층으로 사용하는 경우에 대한 수열온도 간편 예측식을 제시하였으며, 이에 대한 검증을 실험결과를 통해 수행하였고 HSC를 이용한 부재에 대한 본 예측식의 적용 방법을 제시하였다.

섬유혼입 고강도 콘크리트의 열전달 및 역학적 거동 해석모델에 대한 연구 (Study on The Heat Transfer and Mechanical Modeling of Fiber-Mixed High Strength Concrete)

  • 신영섭;한동석;염광수;전현규
    • 한국방재학회 논문집
    • /
    • 제11권2호
    • /
    • pp.45-52
    • /
    • 2011
  • 고강도 콘크리트의 폭렬현상을 억제하여 내화 성능을 개선하기 위한 방법으로 고온에서 수증기가 콘크리트 표면으로 이동할 수 있도록 경로를 제공하여 주는 섬유를 혼입하는 방안이 있다. 본 연구에서는 섬유혼입 고강도 콘크리트 기둥에 대한 재하 내화 실험을 수행하였고, 내부 철근의 온도분포 예측을 위한 열전달 모델과 고온에서 콘크리트 기둥의 역학적 거동에 대한 재료모델을 제시하였다. 화재 시 콘크리트 내부의 물리적인 현상과 콘크리트의 열적 특성을 고려하여 선행 연구의 재료모델을 수정하였다. 수정한 모델을 이용한 섬유혼입 고강도 콘크리트의 유한요소 해석을 실행하였고, 재하 내화실험과의 비교를 통하여 재료모델을 제안하였다.

섬유혼입공법을 적용한 고강도콘크리트 기둥의 비재하 내화시험 (Fire Test of Fiber Cocktail Reinforced High Strength Concrete Columns without Loading)

  • 염광수;전현규;김흥열
    • 콘크리트학회논문집
    • /
    • 제21권4호
    • /
    • pp.465-471
    • /
    • 2009
  • 화재시 고강도콘크리트의 폭렬현상을 막고 내부철근 온도의 상승을 억제하기 위하여 폴리프로필렌섬유와 강 섬유를 동시에 사용하는 섬유혼입공법을 제안하였다. 섬유혼입공법을 40~100 MPa 고강도콘크리트 배합에 적용하여 가 열재하방법으로 열적특성을 평가한 후 내화성능을 평가하기 위하여 구조부재에 내화시험을 실시하였다. 2기의 기둥시 험체를 제작하여 ISO 834 표준내화곡선에 따라 180분 비재하 내화시험을 실시하였다. 폭렬은 발생하지 않았으며, 표면 부의 색은 분홍색을 띤 회색으로 변했다. 깊이 60 mm부터 내부 콘크리트의 온도가 급감하였으며, 60분 가열 후 온도구 배는 보통콘크리트보다 5배 적은 2.2oC/mm로 측정되었다. 180분 내화시험 후의 최종온도는 모서리철근이 488.0oC, 중앙 철근이 350.9oC이며, 철근의 총 평균온도는 419.5oC이다. 모서리철근과 중앙철근의 평균온도차는 137.1oC였다. 가열 후 100~150oC부근에서 콘크리트와 철근의 온도상승추세가 변하는데 이는 강섬유와 폴리프로필렌섬유를 혼입한 콘크리트의 온도구배가 낮고, 철근으로의 수분이동과 내부 수분의 막힘현상, 그리고 수분의 기화열 때문이다.

폭렬 현상을 고려한 RC 구조물의 PBD기반 구조내화설계 기술개발에 관한 연구(III) -일본의 내화안전성평가기법을 활용한 사례조사 연구- (A Study on the Structural Fire Resistance Performance Design of RC Structural according to the Explosive Spalling - A Case Study on the Evaluation Method of Structural Fire Resistance in Japan -)

  • 김세종;이재영;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.310-315
    • /
    • 2008
  • The objective of design for a post flash-over fire is contain the fire and prevent structural collapse, as necessary to meet the performance requirements. In the post flash-over phase of a fire all of the combustible objects in the compartment are burning and the heat release rate is limited either by the fuel surface area or the available air supply. So for the PBD situations, the process of evaluation method for fire phenomena is very important. It is the aim of this study to investigate and analyze the evaluation method of structural fire resistance in Japan.

  • PDF

PP섬유 혼입 및 메탈라스 횡구속에 의한 고성능 콘크리트의 폭열방지에 관한 실험적 연구 (An Experimental Study on the Spatting Resistance of High Performance Concrete with PP Fiber Contents and Lateral Confinement by Metal-Lath)

  • 황인성;이백수;이병열;양성환;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.557-562
    • /
    • 2002
  • This paper describes the results of spalling by fire prevention of high performance concrete confining with metal-lath and containing PP fiber. According to test results, all the specimens without PP fiber shows entire failure after exposed to fire, while the other specimens confined with metal-lath has somewhat better spatting prevention performance than plain concrete specimens, which only show surface scale spatting combination of PP fiber with confinement of metal-lath leads to favorable spatting resistance. As PP fiber contents and thickness of metal-lath which is confined at concrete specimens increase, residual strength after exposed to fire shows to be increased.

  • PDF

시간-주파수 분석을 이용한 파이프 부식감시 (Application of Time Frequency Analysis to On Line Monitoring of Pipe Corrosion)

  • 박기용;이철권;이상정
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.2616-2618
    • /
    • 2005
  • Time-frequency analysis (TFA) method was applied to identify the integrity of the internal local surface of a pipe where some chemical corrosions are likely to occur by acid mixed in the coolant of nuclear power plants. The spalling out of internal material pieces by corrosion induces some transient signals and the change of structural vibration of a local point in the pipe. It is therefore possible to detect the corrosion detachment through the measurement of the transient acoustic signals or the vibration signals. In this presentation, the TFA was configured on the vibrational signal data of the pipe and it is identified that the TFA can Provide an important information, i.e., the amplitude fluctuations in the instantaneous frequency of each characteristic frequency.

  • PDF

조강시멘트를 이용한 도로포장 박층 덧씌우기 공법의 실용화 연구 (Application of Thin Bonded Concrete Overlay for Concrete Pavement Rehabilitation using Type III Cement)

  • 박정준;백상현;정재헌;엄주용;윤경구;엄태선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.493-498
    • /
    • 1999
  • Many concrete pavements closed to the end of service life in out country need to repair. We investigated material and mix designs for thin bonded concrete overlay and applied it to concrete pavement rehabilitation. The concrete with Type III cement showed earlier strength and better durability than the concrete with Type I cement. Designed concrete mixture with TypeIII cement made it possible to open the road earlier against heavy vehicles, increased traffic despite of cold weather in winter. In the field examination after four month, there was no defects like as shrinkage crack, spalling, surface abrasion and scaling, and good traffic condition has been maintained.

  • PDF

동결융해 작용을 받는 콘크리트 구조물의 내구성능 저하 예측 방법에 관한 연구 (A Study on the Deterioration Prediction Method of Concrete Structures Subjected to Cyclic Freezing and Thawing)

  • 고경택;김도겸;조명석;송영철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권1호
    • /
    • pp.131-140
    • /
    • 2001
  • In general, the deterioration induced by the freezing and thawing cyclic in concrete structures often leads to the reduction in concrete durability by the cracking or surface spalling. If it can prediction of concrete deterioration subjected to cyclic freezing and thawing, we can rationally do the design of mix proportion in view of concrete durability and the maintenance management of concrete structures. Therefore in this study a prediction method of deterioration for concrete structures subjected to the irregular freezing and thawing is proposed from the results of accelerated laboratory freezing and thawing test using the constant temperature condition and the in-situ weathering data. Furthermore, to accurately predict the concrete deterioration, a method of modification for the effect of hydration increasing during rapid freezing and thawing test is investigated.

  • PDF