Investigation of Natural Convective Heat Flow Characteristics of Heat Sink (히트싱크의 자연대류 열유동 특성 분석)

  • Jung, Tae Sung;Kang, Hwan Kook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.27-33
    • /
    • 2013
  • To ensure proper functioning of electrical and mechanical systems, cooling devices are of great importance. A heat sink is the most common cooling device used in many industries such as the semiconductor, electronic instrument, LED lighting, and automotive industries. To design an optimal heat sink, the required surface area for heat radiation should be calculated based on an accurate expectation of the heat flow rate in the target environment. In this study, the convective heat flow characteristics were numerically investigated for a vertically installed typical heat sink and a horizontally installed one in free convection using ANSYS CFX. Comparative experiments were carried out to reveal the quantitative effect of the installation direction on the cooling performance. Moreover, the result was analyzed using the dimensionless correlation with the Nusselt number and Rayleigh number and compared with well-known theories. Finally, it was observed that the cooling performance of the vertically installed heat sink is approximately 10~15% better than that of the one in natural convection.

Dispersion Characteristics of Cylindrical Shells Submerged in the Fluid (유체에 잠긴 원통형 실린더의 파동 분산 특성)

  • Jung, Byung-Kyoo;Hong, Chinsuk;Ryue, Jungsoo;Jeong, Weui-Bong;Shin, Ku-Kyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.8
    • /
    • pp.575-582
    • /
    • 2015
  • This paper deals with the dispersion relation of the waves sustained in a cylindrical shell submerged in the fluid. The waveguide finite method and the boundary element method are used to predict the dispersion characteristic of the cylindrical shell. The dispersion diagram of the cylinder is estimated from the eigenvalue problem and the forced vibration response. It follows that the water-loading leads to the decrease of the cut-on frequencies and the phase speeds of the bending waves. On the contrary, the longitudinal waves and the torsional waves are hardly affected by the fluid, and therefore the order of the cut-on frequencies of the waves is changed. The acoustic dispersion diagram is also estimated from the forced acoustic response to identify the characteristics of the wave radiated to the fluid. It follows that the acoustic waves on and near the surface of the cylinder are the same as those in the structure. But at the far field the acoustic waves caused by subsonic waves e.g., the bending waves disappear as the increase of the distance. Conclusively, the characteristics of waves in cylindrical shells are significantly affected by water-loading in terms of the cut-on frequency, the wave speed, the order of the cut-on and radiation.

Different Analysis of b2 Peaks in SERS Spectra of 4-aminobenzenethiol

  • Choe, Han-Gyu;Son, Hyeon-Gyeong;Yu, Hyeon-Ung;Lee, Tae-Geol;Kim, Ji-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.257-258
    • /
    • 2012
  • The SERS spectra of 4-aminobenzenethiol (ABT) have served as the "probe" molecule, which have helped spectroscopists to build up the electromagnetic (EM) and chemical (CHEM) enhancement mechanisms. In particular, the b2-peaks (9b, 3, and 19b) of the SERS spectra of ABT have been attributed to arise from the vibronic charge-transfer (CT) between Au or Ag surface and the ABT. Quite recently, however, Tian and co-workers [1] claimed that the b2-peaks are not the CT-enhanced spectra of ABT. Instead, these peaks arise from the 4,4'-dimercaptoazobenzenes (DMABs) that are produced by the oxidative coupling of two ABTs. Their claim is under intense debate currently. Herein, we studied spatially and temporally resolved SERS spectra of ABTs on Ag thin film (thickness of 10 nm), to investigate such claim. Herein, we present a series of additional evidences that strongly support that the b2 intensities of ABTs do not arise from the CT-enhancement: (1) the b2-peaks can be locally "activated" (i. e. turned on) irreversibly with focused laser radiation; (2) the TOF-SIM spectrometry on the activated region show depletion of ABT-Ag+ ions; and finally (3) the spatially resolved FT-IR spectra of the activated region show two pronounced peaks at 1377 cm-1 and 1460 cm-1, both of which can be assigned to the stretching mode of N=N bond. While the result does not disprove the existence of CT or CHEM enhancement in general, the results do show that previous interpretations of the spectra of ABTs should be re-interpreted.

  • PDF

Measurement of EUV Emission and its Plasma Parameters Generated from the Coaxial Plasma Focus of Mather and Hypocycloidal Pinched Electrodes

  • Lee, Sung-Hee;Lee, Kyung-Ae;Hong, Young-June;Uhm, Han-Sup;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.332-332
    • /
    • 2011
  • The extreme ultraviolet (EUV) radiation, whose wavelength is from 120 nm down to 10 nm, and the energy from 10 eV up to 124 eV, is widely utilized such as in photoelectron spectroscopy, solar imaging, especially in lithography and soft x-ray microscopy. In this study, we have investigated the plasma diagnostics as well as the debris characteristics between the two types of dense plasma focusing devices with coaxial electrodes of Mather and hypocycloidal pinch (HCP), respectively. The EUV emission intensity, electron temperature and plasma density have been investigated in these cylindrical focused plasma along with the debris characteristics. An input voltage of 5 kV has been applied to the capacitor bank of 1.53 uF and the diode chamber has been filled with Ar gas at pressure ranged from 1 mTorr and 180 mTorr. The inner surface of the cathode was covered by polyacetal insulator. The central anode electrode has been made of tin. The wavelength of the EUV emission has been measured to be in the range of 6~16 nm by a photo-detector (AXUV-100 Zr/C, IRD). The visible emission has also been measured by the spectrometer with the wavelength range of 200~1,100 nm. The electron temperature and plasma density have been measured by the Boltzmann plot and Stark broadening methods, respectively, under the assumption of local thermodynamic equilibrium (LTE).

  • PDF

A Study on the Process Conditions of ACA( Anisotropic Conductance Adhesives) for COG ( Chip On Glass) (COG(Chip On Glass)를 위한 ACA (Anisotropic Conductive Adhesives) 공정 조건에 관한 연구)

  • Han, Jeong-In
    • Korean Journal of Materials Research
    • /
    • v.5 no.8
    • /
    • pp.929-935
    • /
    • 1995
  • In order to develop COG (Chip On Glass) technology for LCD module interconnecting the driver IC to Al pad electrode on the glass substrate, Anisotropic Conductive Adhesive(ACA) process, the most promising one among COG technologies, was investigated. ACA process was carried out by two steps, dispensing of ACA resin in the bonding area and curing by W radiation. Load on the chip was ranged from 2.0 to 15kg and the chip was heated at about 12$0^{\circ}C$. In resin, the density of conductive particles coated with Au or Ni at the surface were 500, 1000, 2000 and 4000 particles/$\textrm{mm}^2$, and the diameter of particles were 5, 7 and 12${\mu}{\textrm}{m}$. As a result of the experiments, ACA process using ACA particle of diameter and density of 5${\mu}{\textrm}{m}$ and 4000 particles/$\textrm{mm}^2$ respectively shows optimum characteristic with the stabilzed bonding properties and contact resistance.

  • PDF

Radiation Shielding Analysis for Conceptual Design of HIC Transport Package (HIC 전용 운반용기 개념설계를 위한 방사선 차례해석)

  • Cho Chun-Hyung;Lee Kang-Wook;Lee Yun-Do;Choi Byung-Il;Lee Heung-Young
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.457-463
    • /
    • 2005
  • KHNP(Korea Hydro and Nuclear Power Ltd., Co.) is developing a HIC transport package which is satisfying domestic and IAEA regulations and NETEC(Nuclear Environment Technology Institute) is conducting a conceptual design. In this study, the shielding thickness was calculated using the data from radionuclide assay program which is currently using in nuclear sites and Micro Shield code. Considering the structural safety, carbon steel was chosen as shielding material and the shielding thickness was calculated for 500 R/hr and 100 R/hr at HIC surface, respectively. Through the shielding analysis, it was evaluated that the regulation limit is satisfied when the shielding thickness is 22 cm for 500 R/hr and 17 cm for 100/hr.

  • PDF

Environment Corresponding Package by Quantitative Mixing System with Functional Inorganic Material and Polyolefin Resin (기능성 무기물과 폴리올레핀계 수지의 정량적 혼합시스템에 의한 환경대응형 포장소재 개발)

  • Kim, Hi-Sam;Lim, Hyun-Ju;Park, Young-Mi
    • Textile Coloration and Finishing
    • /
    • v.21 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • A lot of research has been made over the recent decade to develop testing packages with antimicrobial properties to improve food safety. In this study, a new method, experimental device and technology for environmental corresponding packages of polypropylene (PP) film has been developed to provide effective temperature buffering during the transport/long-term storage of grains or foodstuffs from the supplier to the market. This quantitatively optimized mixing system enabled to produce PP films with the 700$\sim$1,400d (width;1.5$\sim$3mm, thickness;0.01$\sim$0.5mm). In the whole mixing systems, the finely-granulated inorganic illite and PP virgin chip for master batch (M/B) chip was calculated by digital measurement methods, and then the M/B chip for PP film was adapted through a air jet and PP grinding method. The prepared PP film was characterized with tensile strength and elongation, far infrared radiation (FIR) emissivity, antimicrobial activity and deodorization properties. The results revealed that the two differently grain-sized illite could be show homogeneously dispersed on PP chip surface, and as the increasing of illite content, the FIR emissivity and the anion emission rate of film was increasingly improved. In both of 325 and 1,500 mesh-sized illite contained PP chip, of course the antimicrobial activity was good. But the ultimate deodorization rate for ammonia gas of PP film were found to be approximately the same.

Correlation of Reflection Coefficient and Extracted Efficiency of an Oscillating Water Column Device in Front of a Seawall (안벽 앞에 설치된 진동수주형 파력발전장치의 반사율과 추출효율과의 상관관계)

  • Cho, Il Hyoung;Kim, Jeongrok
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.4
    • /
    • pp.242-251
    • /
    • 2020
  • In this study, the extraction efficiency and reflection coefficient by a two-dimensional OWC (Oscillating Water Column) WEC (wave energy converter) installed in front of a seawall was investigated for regular/irregular waves. The matched eigenfunction expansion method (MEEM) based on the linear potential theory was applied as an analytical tool. The diffraction problem by the incident wave in the open-chamber and the radiation problem by the oscillating pressure in the closed-chamber were solved to obtain the volume fluxes at the internal free-surface. Applying the volume fluxes into the continuity equation for the airflow in a chamber, we got the oscillating air pressure. The maximum extracted power and corresponding reflection coefficient were determined at the optimal turbine coefficient that maximizes the extracted power. OWC device designed for a high extracted efficiency simultaneously contributes to reduce reflected waves.

A glucose biosensor based on deposition of glucose oxidase onto Au nanoparticles poly(maleic anhydride)-grafted multiwalled carbon nanotube electrode (금 나노입자/폴리(maleic anhydride) 그래프트 탄소나노튜브에 글루코스 옥시다아제 담지를 기반으로 한 글루코스 바이오센서)

  • Piao, Ming-Hua;Son, Pyeong-Soo;Chang, Choo-Hwan;Choi, Seong-Ho
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.165-171
    • /
    • 2010
  • Glucose oxidase ($GOD_{ox}$) immobilized biosensor was fabricated by two methods. In one of the methods, gold nanoparticles (Au-NPs) prepared by ${\gamma}$-irradiation were loaded into the poly(maleic anhydride)-grafted multi-walled carbon nanotube, PMAn-g-MWCNT electrode via physical entrapment. In the other method, the Au-NPs were prepared by electrochemical reduction of Au ions on the surface of PMAn-g-MWCNT electrode and then GODox was immobilized into the Au-NPs. The $GOD_{ox}$ immobilized biosensors were tested for electrocatalytic activities to sense glucose. The sensing range of the biosensor based on the Au-NPs physically modified PMAn-g-MWCNT electrode was from $30\;{\mu}M$ to $100\;{\mu}M$ for the glucose concentration, and the detection limit was $15\;{\mu}M$. Interferences of ascorbic acid and uric acid were below 7.6%. The physically Au deposited PMAn-g-MWCNT paste electrodes appear to be good sensor in detecting glucose.

Fabrication and Performance Evaluation of a Scintillating Film-based Gamma Imaging Detector to Measure Gamma-ray Distribution (감마선 분포 측정을 위한 섬광필름 기반의 감마 영상 검출기 제작 및 성능평가)

  • Shin, Sang Hun;Yoo, Wook Jae;Jang, Kyoung Won;Cho, Seunghyun;Lee, Bongsoo
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.202-207
    • /
    • 2015
  • As a feasibility study on development of a gamma imaging probe, we developed a scintillating film-based gamma imaging detector that can obtain scintillation images with information of gamma-ray distribution. The scintillating film-based gamma imaging detector was composed of a sensing probe, an image intensifier, and a beam profiler. To detect and transmit scintillation image, the sensing probe was fabricated by coupling a scintillating film, a fiber-optic image conduit, and a fiber-optic taper, consecutively. First, the optical images of USAF 1951 resolution target were obtained and then, modulation transfer function values were calculated to test the image quality of the sensing probe. Second, we measured the scintillation images according to the activity of the 137Cs and the distance between the surface of 137Cs and the distal-end of sensing probe. Finally, the intensities of scintillating light as functions of the activity and the distance were evaluated from the region of interest in the scintillation image. From the results of this study, it is expected that a fiber-optic gamma imaging detector can be developed to detect gamma-rays emitted from radiopharmaceuticals during radioimmunoguided surgery.