• Title/Summary/Keyword: surface microhardness

Search Result 320, Processing Time 0.02 seconds

A Study of Structure & Composition Characteristics of the(Ti, Al) N Coating on the STS 304 by D.C. Magnetron Sputtering (D.C. Magnetron Sputter를 이용한 (Ti, Al) N 피막의 조성 및 조직특성연구)

  • 최장현;이상래
    • Journal of the Korean institute of surface engineering
    • /
    • v.25 no.5
    • /
    • pp.223-233
    • /
    • 1992
  • (Ti, Al)N films were deposited on 304 stainless steel by D.C. magnetron sputtering using Al target and Ti plate. The properties of (Ti, Al)N films such as composition, microhardness, grain size, crystal structure were investigated. The chemical composition of (Ti, Al)N films was similar to the sputter area ratio of titanium to aluminum target by means of EDS and AES survey. The higher bias voltage to substrate and the smaller input of N2 gas showedthe increased microhardness and the finer grain size of the films. The results obtained from this study show, it is belived, that the (Ti, Al)N film by D.C.magne-tron sputtering is promising in the wear resistance use.

  • PDF

Influence on EDM Surface with the Copper and Graphite Electrode According to the Discharge Energy (방전에너지에 따라 동전극과 흑연전극이 방전가공면에 미치는 영향)

  • Choi, Jae-Yong;Jeon, Eon-Chan;Jeong, Jae-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.5
    • /
    • pp.53-59
    • /
    • 1997
  • This study has been performed to inmvestigate MRR(metal removal rate), REW(relative electrode wear), surface roughness, heat transumutation layer and microhardness distribution in cross-section of the machined surface with various pulse-on duration and peak pulse current, using the copper and graphite electrode on the heat treated STD11 which is extensively used for metallic molding steel with the EDM. The results obtained are as follows; a) There exists critical pulse-on duration(If Ip equals 5A, .tau. on is 50 .mu. s) which shows the the maximum MRR in accordance with peak oulse current and the MRR decreases when the pulse-on duration exceeds the critical pulse-on during because of the abnormal electric discharge. b) Safe discharge is needed to make maximum of MRR and the metalic organization must be complicated for discharge induction. c) Graphite has much more benefits than copper electrode when rapid machining is done without electrode wear. d) The most external surface has the highest microhardness because of car- burizing from heat analysis of the dielectric fluid and the lower layar of the white covered layer has lower microhar dness than base matal because of softening.

  • PDF

THE COLOR STABILITY OF AESTHETIC RESTORATIVE MATERIALS RESULTING FROM ACCELERATED AGING

  • Lee, Jeong-Seon;Suh, Kyu-Won;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.577-585
    • /
    • 2008
  • STATEMENT OF PROBLEM: The discoloration of anterior teeth restoration is one of the material problems demanding retreatment. OBJECTIVES: To evaluate the color stability and affecting factors on esthetic restorative materials when subjected to accelerated aging. MATERIAL AND METHODS: This study was conducted using porcelain disks (IPS Empress 2-glazed, IPS Empress 2-polished), direct restorative resin disks (SYNERGY Duo) and indirect restorative resin disks (Sinfony, TESCERA ATL). Accelerated aging was done by precipitating the specimens in 38.C distilled water and irradiating with xenon light, and the total irradiation was 397.98 KJ/mm. Color and microhardness change of the specimens were measured before accelerated aging and after 100 hours, 200 hours and 300 hours of accelerated aging, and Surface of the specimens were examined with SEM before and after 300 hours of accelerated aging. RESULTS: 1. After 300 hours' accelerated aging, a ${\Delta}E$ value was 3.3 or lower in IPS Empress 2-glazed, IPS Empress 2-polished and Sinfony. 2. After 300 hours' accelerated aging, gloss was lost and surface changes including microcracks were observed in TESCERA ATL and SYNERGY Duo, and color changes of them ranged between 3.58 and 6.40 ${\Delta}E$ units. 3. During 300 hours' accelerated aging, the microhardness of surface was increased by 3.21 - 19.64% in all kinds of composites resin. CONCLUSION: After 300 hours' accelerated aging, SEM images IPS Empress 2-glazed, IPS Empress 2-polished and Sinfony showed little morphological change and their color changes were considered to be clinically acceptable. And there was significant correlation between microhardness changes and color changes of composites (P < .05).

Impact of combined at-home bleaching and whitening toothpaste use on the surface and color of a composite resin

  • Carolina Meneghin Barbosa;Renata Siqueira Scatolin;Waldemir Francisco Vieira-Junior;Marcia Hiromi Tanaka;Laura Nobre Ferraz
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.3
    • /
    • pp.26.1-26.12
    • /
    • 2023
  • Objective: This in vitro study aimed to evaluate the effects of different whitening toothpastes on a composite resin during at-home bleaching with 10% carbamide peroxide. Materials and Methods: Sixty samples (7 mm × 2 mm) were used for color and roughness analyses, while another 60 samples (3 mm × 2 mm) were utilized to assess microhardness. The factors analyzed included toothpaste, for which 5 options with varying active agents were tested (distilled water; conventional toothpaste; whitening toothpaste with abrasive agents; whitening toothpaste with abrasive and chemical agents; and whitening toothpaste with abrasive, chemical, and bleaching agents). Brushing and application of whitening gel were performed for 14 days. Surface microhardness (SMH), surface roughness (Ra), and color (ΔL*, Δa*, Δb, ΔE*ab, and ΔE00) were analyzed. The Ra and SMH data were analyzed using mixed generalized linear models for repeated measures, while the color results were assessed using the Kruskal-Wallis and Dunn tests. Results: Between the initial and final time points, all groups demonstrated significant increases in Ra and reductions in SMH. No significant differences were found between groups for SMH at the final time point, at which all groups differed from the distilled water group. Conventional toothpaste exhibited the lowest Ra, while whitening toothpaste with abrasive agent had the highest value. No significant differences were observed in ΔL*, Δa*, and Δb. Conclusions: While toothpaste composition did not affect the color stability and microhardness of resin composite, combining toothbrushing with whitening toothpaste and at-home bleaching enhanced the change in Ra.

THE CHANGE IN SURFACE CONVERSION AND DISCOLORATION IN DENTAL RESTORATIVE COMPOSITE RESIN UNDER DIFFERENT POLISHING METHODS; THE CORRELATION BETWEEN SURFACE CONVERSION AND SURFACE DISCOLORATION (수복용복합레진의 표면처리방법에 따른 표면중합률 및 변색정도의 변화와 그 상관관계에 대한 연구)

  • Park, Sung-Ho;Noh, Byung-Duk;Kim, Mo-Ran;Ahn, Hyun-Jung
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.482-486
    • /
    • 2000
  • The purpose of the present study was first, to evaluate the relationship between composite surface conversion and surface discoloration, second, to know if there was difference in surface discoloration between celluloid-strip-finished composite surface and polished surface. In addition, the discoloration of composite surface was also evaluated with visual inspection or digital camera with high resolution monitor, Z100, Tetric Ceram, Spectrum, and Aelitfil were used. The composite surfaces were celluloid-strip finished (group 1), polished (group 2), celluloid-strip finished under nitrogen gas purging (group 3) or only light cured without finishing or polishing under nitrogen gas purging (group 4). The microhardness of each samples were also measured in each group. The samples of each group were also divided into 4 subgroup whether they were immediately placed in disclosing solution (0.2% Elythrosin, pH 7.0) (subgroup1), 1 day after light curing(subgroup 2), 3day after light curing(subgroup 3) or 7 day after light curing(subgroup 4). The computer controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$, $b^*$). The amounts of color difference were compared. The results were as follows; 1. There was no difference in discoloration between celluloid strip finished composite surface and polished surface. 2. The samples discolored more when they were placed in disclosing solution immediately after polymerization than other groups. 3. When the samples were light cured under nitrogen gas purging and without polishing process, they discolored more than other groups even though they showed higher micro hardness. 4. With visual inspection or digital camera, only a limited information was available in detecting composite surface discoloration.

  • PDF

THERMAL CHANGE AND MICROHARDNESS IN CURING COMPOSITE RESIN ACCORDING TO VARIOUS CURING LIGHT SYSTEM (광중합기에 따른 복합레진 중합시 온도 변화와 미세경도에 관한 연구)

  • Lee, Dong-Jin;Kim, Dae-Eop;Yang, Yong-Sook;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.391-399
    • /
    • 2004
  • The purpose of this study was to compare curing efficiency of newly developed curing units to traditional halogen curing unit by measuring thermal change and surface microhardness according to curing light system. Materials and mathods : The types of curing units were traditional low intensity halogen light(Optilux 360), plasma arc light(Flipo), low heat plasma arc light(Aurys), low intensity LED(Starlight), and high intensity LED(Freelight2). Temperature at the tip of light guide was measured by a digital thermometer using K-type thermocouple. And after resin was filled to 2, 3, 4mm teflon mold, bottom temperature measured during curing. After 24 hours, microhardness of top surface and bottom surface of each resin specimen were measured. Results : The result of this study can be summarized as follows, 1. As measuring temperature of curing unit tips, Flipo is the highest as $52.4^{\circ}C,\;Freelight2(37.86^{\circ}C),\;Optilux360(32.68^{\circ}C),\;Aurys(32.34^{\circ}C),\;and\;Starlight(26.14^{\circ}C)$ were followed. 2. Flipo and Freelight2 were the highest similarly and Optilux360 and Aurys were similarly next and Starlight was lowest in temperature of bottom surface of resin mold. 3. Microhardness of top surface were generally similar, and Aurys was relatively low. 4. Optilux 360 and Freelight2 were the highest, and Flipo, Starlight, and Aurys were followed in microhardness of bottom surface. Conclusions : The results suggest that careful use of Flipo and Freelight2 might be able to cure greater depth of resin composite and do not cause thermal problems than other curing units.

  • PDF

In vitro Measurement of the Mechanical Properties of Resin Infiltrant: Viscosity, Penetration Pattern, Surface Roughness, Microhardness (초기 법랑질 우식 병소에 대한 Resin infiltrant의 점도, 침투 양상, 표면 조도 및 미세경도)

  • Hong, Seung-Hyun;Kim, Min-Jeong;Cho, Hye-Jin;Yu, Mi-Kyung;Lee, Kwang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.81-90
    • /
    • 2011
  • In this study, we observed the penetration of the resin infiltrant into natural initial caries by SEM and CLSM, evaluated the pH and viscosity of resin infiltrant and several adhesives(All-bond 2, Scotchbond Multi-purpose, Clearfil SE bond), and measured the surface roughness and the microhardness on permanent teeth before and after applied resin infiltrant into initial enamel caries. The viscosity(Pa.s) was observed for resin infiltrant($0.173{\pm}0.012$), All-bond 2($0.754{\pm}0.030$), Scotchbond Multi-purpose($1.46{\pm}0.137$), and Clearfil SE bond($1.28{\pm}0.125$). The pH was measured for resin infiltrant (4.7), All-bond 2(7.5), Scotchbond Multi-purpose(8.2), and Clearfil SE bond(4.67). An application procedure of resin infiltrant increased the surface roughness and the microhardness insignificantly(p>0.05), when compared to non-applied specimens.

Effect of Sodium Fluoride Varnish and Potassium Iodide on Remineralization Efficacy of Silver Diamine Fluoride (불화나트륨 바니쉬와 요오드화 칼륨이 Silver Diamine Fluoride의 재광화 효과에 미치는 영향)

  • Lee, Kunho;Ahn, Junyong;Kim, Jong Soo;Han, Miran;Lee, Joonhaeng;Shin Jisun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.4
    • /
    • pp.467-475
    • /
    • 2021
  • The purpose of this study was to compare the effect of sodium fluoride(NaF) varnish and potassium iodide(KI) on remineralization efficacy of silver diamine fluoride(SDF) by measuring microhardness and evaluating surface morphology by scanning electron microscope(SEM). Artificial caries lesions were induced on extracted primary molars and vickers microhardness was measured. Specimens were randomly separated into 4 groups for treatment. The specimens in group I were treated with SDF, group II with NaF varnish after SDF, group III with KI after SDF and group IV with distilled water. After 8 days of pH cycling, vickers microhardness was measured and difference before and after treatment was calculated. For SEM, 2 samples were evaluated respectively after enamel polishing, lesion formation and after pH cycling. Group III showed highest increase in microhardness. Group I showed higher increase in microhardness than Group II but without statistical difference. Group IV showed lowest increase in microhardness value among 4 groups. On SEM image, group I, II and III showed smoother and less irregular surface compared to group IV. Amorphous crystal pellicles were observed in group III. In conclusion, SDF, SDF and NaF, SDF and KI groups showed smoother surface and increase in microhardness suggesting the possibility that remineralization effect might take place in oral conditions. In addition, in limited conditions of this study, applying NaF varnish after SDF did not increase the remineralization efficacy of SDF while KI significantly increased the remineralization efficacy of SDF. However, additional study considering various conditions that might affect demineralization and remineralization in clinical situations need to be conducted.

A STUDY ON THE CHANGES IN POLYMERIZATION OF LIGHT-ACTIVATED COMPOSITE RESIN WITH VARIOUS EXPOSURE TIME AND DISTANCE (광중합형 복합레진의 중합시간과 거리에 따른 중합도의 변화)

  • Ahn, Myung-Ki;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.2
    • /
    • pp.293-299
    • /
    • 2001
  • The aim of this study was to evaluate the effect of the distance of the light tip to the surface of restoration and exposure time on the polymerization of surface and 2mm below the surface of light-activated composite resins. Two light-activated composite resins were used. From the experiment, the following results were obtained. 1. Relative light intensity rapidly decreased when distance of the light tip to the surface of material is more than 2mm(p<0.05). 2. In all groups, microhardness was increased according to the increase of relative light intensity and exposure time(p<0.05). 3. The distance of the light tip to the surface of restoration and exposure time more affected 2mm below the surface rather than the surface(p<0.05). 4. Although exposure time was increased, difference of microhardness of the 2mm below the surface with the distance of the light tip to the surface of restoration was relatively high in Z100 between below 4mm and other groups and Z250 between below 2mm and other groups(p<0.05).

  • PDF

Effects of Process Parameters on the Coating Properties of APS TiO2 ioceramic Coatings

  • Kim, Hak-Kwak;Jang, Ju-Woong;Kim, Byoung-Soo;Moon, Ji-Woong;Lee, Deuk-Yong;Lee, Chang-Hee
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.2
    • /
    • pp.123-127
    • /
    • 2003
  • The effects of process parameters on coating formation and coating properties were investigated using a fused and crushed Ti $O_2$powder by the Taguchi method and L$_{9}$(3$^4$) orthogonal array. The Taguchi analysis was conducted through the results of the coating properties affected strongly by plasma spraying parameters and Ti $O_2$powder was sprayed on Ti-6Al-4V alloy substrate. The coating properties were characterized by thickness, microhardness, porosity and surface roughness using optical microscopy, image analyzer and surface roughness tester respectively. An observed optimum condition of plasma spraying process could be found for potential use as a bioceramic coating.