• Title/Summary/Keyword: surface localization

Search Result 194, Processing Time 0.022 seconds

Investigating the Spatial Focusing Performance of Time Reversal Lamb waves for Impact Localization on a Plate (판의 충격위치 추정을 위한 시간반전 램파의 공간모임성능 규명)

  • Park, Hyun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.418-429
    • /
    • 2011
  • Researches using time reversal acoustics (TRA) for impact localization have been paid attention to recently. Dispersion characteristics of Lamb waves, which restrict the utility of classical nondestructive evaluation based on time-of-flight information, can be compensated through the application of TRA to Lamb waves on a plate. This study investigates the spatial focusing performance of time reversal Lamb waves on a plate using finite element analysis. In particular, the virtual sensor effect caused by multiple wave reflections at the boundaries of the plate is shown to enable the spatial focusing of Lamb waves though a very small number of surface-bonded piezoelectric (PZT) sensors are available. The time window size of forward response signals, are normalized with respect to the number of virtual active sensors. Then their effects on the spatial focusing performance of Lamb waves are investigated.

  • PDF

Effect of Annealing Temperature with Silver Nanoparticles Incorporation on the Electronic Structure of Poly (3, 4-ethylenedioxythiphene) : poly (styrenesulfonate) Film (은 나노입자가 함침된 Poly (3, 4-ethylenedioxythiphene) : poly (styrenesulfonate)필름의 전자 구조상태에 미치는 열처리효과 연구)

  • Wang, Seok-Joo;Lee, Cho-Young;Park, Hyung-Ho
    • Korean Journal of Materials Research
    • /
    • v.18 no.9
    • /
    • pp.503-506
    • /
    • 2008
  • The effect of silver nanoparticles (NPs) incorporation on the electronic properties of poly (3, 4-ethylenedioxythiphene) : poly(styrenesulfonate) (PEDOT : PSS) films was investigated. The surface of silver NPs was stabilized with trisodium citrate to control the size of silver NPs and prevent their aggregation. We obtained ca. 5 nm sized silver NPs and dispersed NPs in PEDOT : PSS solution. Sheet resistance, surface morphology, bonding state, and work function values of the PEDOT : PSS films were modified by silver NPs incorporation as well as annealing temperature. Sodium in silver NPs solution could lead to a decrease of work function of PEDOT : PSS; however, large content of silver NPs have an effect on the increase in work function, resulting from charge localization on the silver NPs and a decrease in the number of charge-trapping-related defects by chemical bond formation.

A New Spatial Localization Technique Using High-Order Surface Gradient Coils (SGC) (고차표면 경사자계코일을 이용한 새로운 공간 선택 방법)

  • Lee, J.K.;Yang, Y.J.;Jeong, S.T.;Yi, Y.;Cho, Z.H.;Oh, C.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.43-46
    • /
    • 1994
  • A new spatial localization technique using high-order surface gradient coil (SGC) is proposed. Although the Spatial Selection with High-Order gradient (SHOT) can provide a 2-D selection with only one selective RF pulse, the high-order gradient produced by cylindrical-shape coils has not been clinically useful for clinical systems due to the large minimum selection size caused by the limited radial gradient intensity. However, by using the proposed high-order SGCs located near the imaging region, the size of volume selection can be reduced to a clinically useful 1-4 cm in diameter by applying stronger radial gradient with much less gradient driving power. A 40 cm-by-40 cm $r^{2}$ SGC has been designed and constructed, and phantom and volunteer studies have been performed. Experimental results using spatially localized MRI show good agreement to the theoretically predicted behavior.

  • PDF

Immunoelectron Microscopic Localization and Analysis of Herpes simplex Virus Type 2 Antigens (전자현미경 기법을 이용한 Herpes simplex 2형 바이러스 항원의 면역학적 분석)

  • 김천식;오명환
    • Korean Journal of Microbiology
    • /
    • v.40 no.1
    • /
    • pp.23-28
    • /
    • 2004
  • Antigenic analysis of Herpes simplex type 2 virus was performed and its major antigen was localized using an immunoelectron microscopy. Antigens of 32, 43, 59 and 69 kDa were constantly expressed during the course of infection for 48 hr in the infected Vero cell. An antigen of 51 kDa was turned out to be the major one in inducing a immune response in Western-blot analysis. The 51 kDa antigen was localized on the surface of HSV-2 by immunoelectron microscopy using colloidal golds and anti-HSV 2 polyc1onal antibody. Immunofluorescence assay indicated that viral antigens were found throughout the infected cell and, especially, on the surface of the cell.

High speed milling titanium alloy (Ti 합금의 고속가공시 밀링특성에 관한 연구)

  • Ming CHEN;Youngmoon LEE;Seunghan YANG;Seungil CHANG
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.454-459
    • /
    • 2003
  • The paper will present chip formation mechanism and surface integrity generation mechanism based on the systematical experimental tests. Some basic factors such as the end milling cutter tooth number, cutting forces, cutting temperature, cutting vibration, the chip status, the surface roughness, the hardness distribution and the metallographic texture of the machined surface layer are involved. the chip formation mechanism is typical thermal plastic shear localization at high cutting speed with less number og shear ribbons and bigger shear angle than at low speed, which means lack of chip deformation. The high cutting speed with much more cutting teeth will be beneficial to the reduction of cutting forces, enlarge machining stability region, depression of temperature increment, auti-fatigability as well as surface roughness. The burrs always exists both at low cutting speed and at high cutting speed. So the deburr process should be arranged for milling titanium alloy in any case.

  • PDF

Micropatterning of Peptides to Solid Surface by Deep-UV Lithography using N-hydroxysuccinimidyl phenol azide (N-hydroxysuccinimidyl phenyl azide와 광반응을 이용한 펩타이드의 마이크로형태 고정화)

  • 김진희;김현정;김종원;장준근;민병구;최태부
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.441-448
    • /
    • 1998
  • Defined spatial localization of biomolecules on the polymer surface Is potentially powerful method to generate biocompatible surface. Photolithography and photochemistry can be used to immobilize peptides only al a given region of the surface. In this study, peptide RGDS, one of the endothelial cells recognition sites of fibronectin, was covalently immobilized on the polystyrene coated surface with micropattern. It was performed by photochemical reactivity of a synthesized N-hydroxysuccinimidyl phenyl azide. The micropatterning was confirmed by staining with fluorescent dye, aminoacetamido fluorescein. Endothelial cell adhesion was observed only on the RGDS immobilized areas.

  • PDF

Immunochemical Localization of Tetrahydrocannabinol (THC) in Chemically Fixed Glandular Thrichomes of Cannabis (Cannabaceae)

  • Eun Soo Kim;Paul G. Mahlberg
    • Animal cells and systems
    • /
    • v.3 no.2
    • /
    • pp.215-219
    • /
    • 1999
  • Monoclonal antibody for delta-9-tetrahydrocannabiol (THC Ab), conjugated with protein A-gold, was employed as a probe to detect THC localization in the gland and subjacent cells of chemically fixed bracts of Cannabis. THC was detected in the outer wall of the disc cells, fibrillar matrix, the surface feature of secretory vesicles, and sheath throughout development of the secretory cavity. The probe was absent from vesicles. Label was also present in anticlinal walls of disc cells and walls of dermal and mesophyll cells. Little or no THC Ab was present in disc cells and none were detected in control tissues. This distribution pattern of THC Ab was similar to that in tissues prepared by high pressure cryofixation-cryosubstitution. Consistent association of THC with wall and wall-derived materials suggests that cannnabinoids are synthesized outside the plasma membrane and bound to a wall component, where-upon they are transported to the cavity with wall materials released from the disc cell wall during development of the secretory cavity.

  • PDF

Experiments for the Acoustic Source Localization in 2D Cavity Flow (2차원 공동 유동에서의 소음원 위치 판별을 위한 실험적 연구)

  • Lee, Jaehyung;Park, Kyu-Chol;Choi, Jong-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1241-1248
    • /
    • 2004
  • This paper presents an acoustic source localization technique on 2D cavity model in flow using a phased microphone array. Investigation was performed on cavity flows of open and closed types. The source distributions on 2D cavity flow were investigated in an anechoic open-jet wind tunnel. The array of microphones was placed outside the flow to measure the far field acoustic signals. The optimum sensor placement was decided by varying the relative location of the microphones to improve the spatial resolution. Pressure transducers were flush-mounted on the cavity surface to measure the near-filed pressures. It is shown that the propagated far field acoustic pressures are closely correlated to the near-field pressures and their spectral contents are affected by the cavity parameter L/D.

Behaviour of interfacial layer along granular soil-structure interfaces

  • Huang, Wenxiong;Bauer, Erich;Sloan, Scott W.
    • Structural Engineering and Mechanics
    • /
    • v.15 no.3
    • /
    • pp.315-329
    • /
    • 2003
  • As shear occurs along a soil-structure interface, a localized zone with a thickness of several grain diameters will develop in soil along the interface, forming an interfacial layer. In this paper, the behaviour of a soil-structure interface is studied numerically by modelling the plane shear of a granular layer bounded by rigid plates. The mechanical behaviour of the granular material is described with a micro-polar hypoplastic continuum model. Numerical results are presented to show the development of shear localization along the interface for shearing under conditions of constant normal pressure and constant volume, respectively. Evolution of the resistance on the surface of the bounding plate is considered with respect to the influences of grain rotation.

Acoustic Source Localization in 2D Cavity Flow using a Phased Microphone Array (마이크로폰 어레이를 이용한 2차원 공동 유동에 대한 소음원 규명)

  • 이재형;최종수;박규철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.701-708
    • /
    • 2003
  • This paper presents an acoustic source localization technique on 2D cavity model in flow using a phased microphone way. Investigation was performed on cavity flows of open and closed types. The source distributions on 2D cavity flow were investigated in anechoic open-jet wind tunnel. The array of microphones was placed outside the flow to measure the far field acoustic signals. The optimum sensor placement was decided by varying the relative location of the microphones to improve the spatial resolution. Pressure transducers were flush-mounted on the cavity surface to measure the near-filed pressures. It is shown that the propagated far field acoustic pressures are closely correlated to the near-field pressures. It is also shown that their spectral contents are affected by the cavity parameter L/D.

  • PDF