• 제목/요약/키워드: surface insolation

검색결과 66건 처리시간 0.024초

다단이차원(多段二次元) 집광식(集光式) 태양열(太陽熱) 집열기(集熱器) 개발(開發)에 관(關)한 연구(硏究) - I. 다단이차원(多段二次元) 집광식(集光式) 태양열(太陽熱) 집열기(集熱器)의 열적(熱的) 성능분석(性能分析) (Development of Multistage Concentrating Solar Collector - I. Thermal performance of multistage cylindrical parabolique concentrating solar collector)

  • 송현갑
    • 태양에너지
    • /
    • 제6권2호
    • /
    • pp.3-14
    • /
    • 1986
  • It is desirable to collect the solar thermal energy at relatively high temperature in order to minimize the size of thermal storage system and to enlarge the scope of solar thermal energy utilization. In this study, to develop a solar collector that has both advantages of collecting solar thermal energy at high temperature and fixing conveniently the collector system for long term period, a cylindrical parabolique concentrating solar collector (M.C.P.C.S.C) was designed, which has several rows of parabolique reflectors and thin thickness such as the flat-plate solar collector, maintaining the optical form of concentrating solar collector. The thermal performance of the M.C.P.C.S.C. newly designed in this study was analysed theoretically and experimentally. The results are summarized as follows: 1) prediction equation for outlet temperature, $T_o$, of heat transfer fluid and for the thermal efficiency, ${\eta}$, of the collector were derived as; o $$T_o=[C+B1_n(\frac{I_c(t)}{pv^3})]T_i$$ o $${\eta}=\frac{A}{A_c}\dot{m}[(C-1)+B1_n(E{\cdot}di^6\frac{I_c(t)}{\dot{m}^3})]\frac{T_i}{I_c(t)}$$ 2) When the insolation on the tilted solar collector surface, $I_c$, was $900-950W/m^2$ and the heat transfer fluid was not circulated in tubular absorber, the maximum temperature on the absorber surface was $100-118^{\circ}C$, this result suggested that the heat transfer fluid could be heated up to $98-116^{\circ}C$. The maximum temperature on the absorber surface was decreased with the increase of the collector shape factor, $L_p/L_w$ 3) There was a good agreement between the experimental and theoretical value of solar collector efficiency, ${\eta}$, which was proportional to the collector shape factor, $L_p/L_w$ 4) It is desirable to continue the study on the relationship between the collector shape factor, $L_p/L_w$, and the thermal efficiency of solar collector.

  • PDF

하절기 도심과 외곽지의 열특성 비교 관측 (Study on Field Observations of the Thermal Environment in the Downtown Location and the Outskirt Site)

  • 정임수;최동호;이부용
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.21-25
    • /
    • 2009
  • This study is about heat island as one of the urban climate variation factors in urbanized modern society, which compared and observed the thermal characteristics both the downtown location and the outskirt site in summer. The diurnal air temperature range at each point is $12.6^{\circ}C$ in the downtown location and $14.3^{\circ}C$ in the outskirt site, so, it was found that the diurnal air temperature range in the outskirt site was $1.7^{\circ}C$ higher than in the downtown location. There was 20 minutes difference to reach the highest temperature between globe temperature and air temperature in the downtown location, however, the time spent to reach the highest temperature between globe temperature and air temperature in the outskirt site was the same. When we compared the globe temperature between the downtown location and outskirt site, we found that the temperature in the outskirt site was lower than in the downtown location after sunset due to the sudden temperature drops, although the exposed time to insolation in the outskirt site is longer. The average of globe temperature difference on the sample days was $1.1^{\circ}C$, the average of surface temperature difference on the sample days was $1.0^{\circ}C$, and the average of air temperature difference on the sample days was $2.0^{\circ}C$ Thus, it was found that the average of air temperature difference was higher than the average of globe temperature and the average of surface temperature. The result of this study is that the urban environment factors have more effect on the air temperature difference than globe temperature and surface temperature.

  • PDF

Simple Forecasting of Surface Ozone through a Statistical Approach

  • Ma, Chang-Jin;Kang, Gong-Unn
    • 한국환경보건학회지
    • /
    • 제44권6호
    • /
    • pp.539-547
    • /
    • 2018
  • Objectives: Ozone ($O_3$) advisories are issued by provincial/prefectural and city governments in Korea and Japan when oxidant concentrations exceed the criteria of the related country. Advisories issued only after exposure to high $O_3$ concentrations cannot be considered ideal measures. Forecasts of $O_3$ would be more beneficial to citizens' health and daily life than real-time advisories. The present study was undertaken to present a simplified forecasting model that can predict surface $O_3$ concentrations for the afternoon of the day of the forecast. Methods: For the construction of a simple and practical model, a multivariate regression model was applied. The monitored data on gases and climate variables from Japan's air quality networks that were recorded over nearly one year starting from April 2016 were applied as the subject for our model. Results: A well-known inverse correlation between $NO_2$ and $O_3$ was confirmed by the monitored data for Iksan, Korea and Fukuoka, Japan. Typical time fluctuations for $O_3$ and $NO_x$ were also found. Our model suggests that insolation is the most influential factor in determining the concentration of $O_3$. $CH_4$ also plays a major role in our model. It was possible to visually check for the fit of a theoretical distribution to the observed data by examining the probability-probability (P-P) scatter plot. The goodness of fit of the model in this study was also successfully validated through a comparison (r=0.8, p<0.05) of the measured and predicted $O_3$ concentrations. Conclusions: The advantage of our model is that it is capable of immediate forecasting of surface $O_3$ for the afternoon of the day from the routinely measured values of the precursor and meteorological parameters. Although a comparison to other approaches for $O_3$ forecasting was not carried out, the model suggested in this study would be very helpful for the citizens of Korea and Japan, especially during the $O_3$ season from May to June.

대기안정도 분류방법의 평가 및 실용화에 관한 연구 (Evaluation of Atmospheric Stability Classification Methods for Practical Use)

  • 김정수;최덕일;최기덕;박일수
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.369-376
    • /
    • 1996
  • Major atmospheric stability classification methods were evaluated with meteorological data obtained by scoustic sounding profiler (SODAR/RASS) in Seoul. The Psequill classificatio method, the method most widely used because of its good agreement in respect of synoptic scope under the steady state, fails to describe the time lag, the response time on stability by heating or cooling caused by daily insolation or noctrunal surface radiation. Horizontal and vertical standard deviation of wind fluctuation $(\sigma_A and \sigma_E)$ method tend to classify night-time stable condition (E, F class) into unstable condition (A, B class). The classification matrix tables for Vogt's vertical temperature difference and wind speed using method ($\Delta$T $\cdot$ U) and bulk Richardson number (Rb) were amended for practical use over Seoul. The modified tables for $\Delta$T $\cdot$ U and Rb method were made by using comprehensive frequency distribution from Pasquill's method and other existing results, and the correlation coefficient(r) was equal to 0.829. It was confirmed that atmospheric stability could be changed with monitoring site characteristics, height and vertical difference between sensors of monitoring station, and classification method itself.

  • PDF

고지대 일사량 특성분석에 관한 연구 (A Study on the Analysis of Solar Radiation Characteristics on a High Elevated Area)

  • 조덕기;강용혁;오정무
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.23-28
    • /
    • 2003
  • The purpose of this study is to procure basic data to be used for solar power plant and concentrating collector designs. Site elevation is one of the major factors which influences the incoming insolation to the earth surface. Because the nonpermanent gases such as ozone, water vapor are unmixed components of the atmosphere and their concentrations are the function of height, the site elevation effects the relative proportion of the atmospheric constituents. We have measured solar radiation on Jiri Mt. (1,400m) and in Gurye area(115m) at the near same latitude. These values were then compared to obtain their characteristics and to investigate the potential for the solar utilization for both high and low elevated areas. From the experimental results, we concluded that 1) Daily mean horizontal global radiation and normal beam radiation on Mt. Jiri are 9.5%, and 35.3% higher than Gurye area respectively for a clear day. 2) A significant difference in atmospheric clearness index is observed between Mt. Jiri and Gurye areas.

Cochlodinium polykrikoides 적조의 최초발생해역인 나로도 주변 해역의 해양환경 (Marine Environments in the Neighborhood of the Narodo as the First Outbreak Region of Cochlodinium polykrikoides Blooms)

  • 이문옥;문진한
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제11권3호
    • /
    • pp.113-123
    • /
    • 2008
  • 유독성 Cochlodinium polykrikoides 적조의 최초발생해역으로 알려져 있는 나로도 주변 해역의 해양환경적 특징을 조사하기 위해서 1992년부터 2007년까지 국립수산과학원이 실시한 해양환경측정망 자료 및 적조정보자료와 고흥지방의 기후자료 등을 분석하였다. Cochlodinium polykrikoides 적조는 8월에 나로도 주변 해역에서 최초로 발생한 경우가 가장 많았고, 그 발생시기는 해마다 빨라지고 있는 경향을 보였다. 또한 나로도 주변 해역에서의 표층 염분도 계속 증가하는 추세를 보여, Cochlodinium polykrikoides 적조 발생시기의 빨라짐과의 어떤 관련성을 시사하였다. 한편 나로도 주변 해역에서 Cochlodinium polykrikoides 적조가 최초로 발생할 때는 동일한 시기의 가막만 또는 진해만 해역에 비해 상대적으로 일사량은 많았고 강수량은 적었다. 8월의 나로도 주변 해역의 평균 수온 및 염분은 동일한 시기의 가막만 및 진해만에 비하여 평균 수온은 $0.2{\sim}0.6^{\circ}C$, 염분은 $1.84{\sim}3.91psu$ 각각 더 높았으며, 두 해역에 비해 상대적으로 고온, 고염을 나타내었다. 또한 나로도 주변 해역은 부영양화 해역으로 알려진 진해만에 비해서는 영양염이나 식물플랑크톤의 농도가 현저히 낮았으나, 전체적인 수질환경은 가막만과 크게 다르지 않은 것으로 판단되었다. 주성분 분석결과, 나로도 주변 해역에서 최초로 발생하는 Cochlodinium polykrikoides 적조 요인으로서는 기상인자와 물리적 환경인자인 일사량과 수온이 가장 중요하며, 부차적으로 수질요소인 COD와 용존산소의 농도가 여기에 관여하고 있음을 보여주었다. 태풍 또한 Cochlodinium polykrikoides 적조 발생에 있어 중요한 요인 중의 하나로 생각되었다.

  • PDF

한반도주위 해양에서 의 해면 열수지와 응력의 계절변화 (Seasonal Variation of Surface heat budget and Wind Stress Over the Seas Around the Korean Peninsula)

  • 강인식;김맹기
    • 한국해양학회지
    • /
    • 제29권4호
    • /
    • pp.325-337
    • /
    • 1994
  • 한반도 주변해역에서 의 해면 열속과 응력의 분포를 김과 강(1994)의 지표층 flux 모델을 사용하여 구하였고 이들의 계절변화를 조사하였다. 모델의 입력자료는 유럽중 기기상예보소 (ECMWF)의 1000mb 온도, 비습, 지오포텐샬고도와 미국기상청(NMC)의 해 수면온도 자료를 사용하였다. 자료의 공간해상도는 위도, 경도 2도이며 기간은 1984년 부터 87년까지의 3년이다. 한편, 해면의 단파복사량은 미국항공우주국 (NASA)의 인공 위성 자료를 사용하였고 잔파복사량은 경험식을 사용하여 구하였다. 모든 열속을 합한 순열속을 한반도 주변해역에서 보면, 1월과 10월에 각각 200∼400 Wm/SUP -2/와 100 Wm/SUP -2/로 해양이 냉각되고 4월과 7월에는 약 100 Wm/SUP -2/로 가열되고 있음을 알 수 있다. 한편, 연평균 순열속은 황해 북부를 제외한 전해역에서 음의 값이 나타나 고 있다. 가장 큰 냉각이 일어나는 해역은 쿠로시오 해역으로 이 지역의 연평균 값은 약 120 Wm/SUP -2/이다. 동해에서는 북부와 남부해역에서 60∼80 Wm/SUP -2/의 냉각이 일어나며 중부해역에서는 비교적 적은 30 Wm/SUP -2/ 정도의 냉각이 일어나고 있다. 한편, 1월의 응력 크기는 다른 달에 대하여 3∼5배 정도 크게 나타나고 이에 따라 연 평균응력의 분포는 1월의 형태와 유사하다. 연평균 응력컬은 동지나해와 남해에서 음 의 값이 나타나지만 황해 북부에서는 양의 값을 보인다. 동해의 응력컬은 북부와 남동 해역에서 양의 값이 그리고 북서해역에서는 음의 값이 나타나고 있다.

  • PDF

사용후핵연료 운반용기 덮개 내부 열전달 해석 (Heat Transfer Analysis around Transport Cask under Transport Hood)

  • 이동규;박제호;정인수;김태만;윤정현
    • 방사성폐기물학회지
    • /
    • 제9권3호
    • /
    • pp.161-167
    • /
    • 2011
  • 사용후핵연료 운반용기 표면온도가 $85^{\circ}C$를 초과할 경우, 대인용 보호막(Personnel Barrier) 또는 운반용 덮개(Transport Hood)를 설치하여 운반 중 운반용기 표면에 사람이 직접 접근할 수 없도록 하여야 한다. 운반용 덮개가 설치된 경우, 열적 안전성 평가의 한 가지 경우인 정상조건 열해석 시, 외부환경 경계조건(환경온도 및 외부복사온도)으로 적용하기 위해서 운반용 덮개 내부 열 환경 조건(내부 공기온도 및 운반용 덮개 표면온도)을 계산해야 한다. 따라서 본 연구에서는 운반용 덮개 내부 공기온도 및 표면온도를 계산하기 위한 해석적 방법 및 열전달 특성에 대한 분석을 수행하였고 CFD 해석 결과와 비교를 통해 타당성을 검증하였다.

태양광 시스템의 계절별 일사량과 전력량 (Irradiation and Power Analysis According to Seasons)

  • 이영;정종철;최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.220-220
    • /
    • 2009
  • In case of favourable irradiation conditions, the ratio of irradiation to the total irradiation went up and then the irradiation increased in the area with high angle of inclination. The study showed that on a clear day with the irradiation of more than $800[W/m^2]$, the pattern of alternating current power change in the fixed system was similar with that in the single-axis tracker. On the contrary, in case of unfavourable irradiation conditions, the ratio of diffuse irradiation to the total irradiation went up and then the horizontal irradiation increased. In the demo system, the fixed system, the single-axis tracker and the dual-axis tracker all had low generation power and similar generation pattern with each other. The study showed the generation power varied with the irradiation in the fixed system, while in the single-axis tracker and the dual-axis tracker, the amount of the generation power variation was much more than the irradiation variation. The demo system was operated from 11:00 AM to 2:00 PM for generating power, during which time, 46[%] to 56[%] of the total generation power was produced. In this study. the generation power was increased by 147[%] in the fixed system, by 136[%] in the single-axis tracker, and by 164[%] in the dual-axis tracker, and the pattern of generation power was similar with the generation power variation in the situation where the irradiation increased by 140[%] in the spring with plenty of insolation. The alternating current power was more sensitive to variation of the irradiation than to that of the surface temperature of a module. The variation of the irradiation had a more positive effect on the generation power than the type of array.

  • PDF

공동주택의 태양광시스템 적용성 평가를 위한 전기부하 매칭 해석연구 (A Study on the Electrical Load Matching Analisys for the optimal utilization of grid-conntected PV system in Apartment Complex)

  • 윤종호;박재성;신우철;박재완
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.49-54
    • /
    • 2008
  • This study is to investigate an optimal size and position of PV system for apartment complex enough the electrical load matching analysis. The 4 types of arrangements of apartment buildings are considered as follows; ㅡtype, alternative ㅡtype, ㄱtype and ㅁtype. We assume that the studied site is composed of 9 buildings. Firstly, solar access evaluation of roof and facade in apartment buildings was performing with the hourly simulations of total received insolation on each surface considering the hading effect of buildings. Electrical load profile of typical Korean apartments was investigated for the lad matching analysis. To calculate an annual total PV output, we used MERIT program which is a sourly based load matching tool developed by ESRU. TRY weather data of Daejeon are applied for this analysis. Result shows that approximately 11% of total electric load of the site can be supplied by the PV system in the case of full installation of PV system at the whole south-face roof area of 9 buildings in this stuided apartment complex. Depending of a various installation option of roof and facade area, the possible ratio of PV supply in total electrical load varies from 9% to 42%. Among the 4 arrangement types, the ㅡ type revealed the best option for the maximum output of PV system.

  • PDF